Records from 1996 to 2008. Most recent: inspection, 6 February 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 20
6 February 2008
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3142673
14 March 2007
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2887622
22 March 2006
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2607234
4 January 2006
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2560569
22 March 2005
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2316270
8 November 2004
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2241829
18 March 2004
Hull Examination · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2031682
13 March 2003
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1756399
20 March 2002
COI Inspection · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1495332
26 April 2001
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1395723
23 May 2000
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1384450
22 March 2000
Hull Examination · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1466112
5 August 1999
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 775338
23 March 1999
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1126591
2 July 1998
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 147434
6 May 1998
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 790368
19 March 1998
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 783552
13 May 1997
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1092586
22 May 1996
Initial Certification
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 875929
22 May 1996
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1186802
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 March 2005
Resolved
Properly secure loose wiring hanging on the drive shaft.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2005
Resolved 24 March 2005
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 22 March 2005
Resolved
Adjust the starboard side ventilation damper in the engine space to close properly.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 March 2005
Resolved 24 March 2005
Lifesaving › Lifebuoys
Issued 18 March 2004
Resolved
Renew water light for ring buoy due to cracked housing. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2004
Resolved 25 March 2004
Resolution: [name withheld] witnessed satisfactory test of new water light.
Communications › Alarms/Indicators
Issued 18 March 2004
Resolved
Prove proper operation of flammable vapor detection sensors.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2004
Resolved 25 March 2004
Resolution: [name withheld] examined new sensor and base unit and witnessed satisfactory test of same.
Construction/Loadline › Hull › Hull Plating
Issued 18 March 2004
Resolved
Make permanent repairs to pinhole leak in bottom hull plating in way of rear drive shaft penetration at stbd aft corner of pan.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 March 2004
Resolved 26 March 2004
Resolution: Witnessed satisfactory float test of vessel with no laekage noted.
Lifesaving › Lifejacket/PFD (Type I)
Issued 13 March 2003
Resolved
Provide additional adult Type 1 PFD for a total of 34. Until cleared vessel is restricted to carrying 33 total persons. LEGACY COMPONENT DESC: Quantity
Action required: 705 - Other - as specified
Due 13 April 2003
Resolved 19 March 2003
Resolution: Examined and found satisfactory 34 total adult PFDs.
Engineering › Bilge Water Management System
Issued 13 March 2003
Resolved
Prove proper operation of bilge pumps, bilge high water alarms and flammable vapor detection systems. LEGACY COMPONENT DESC: Pump
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2003
Resolved 19 March 2003
Resolution: Witnessed satisfactory test of bilge pumps, high water alarms and flammable vapor detectors.
Accommodation/Occupational Safety › Medical/First Aid
Issued 20 March 2002
Resolved
Renew Expired Items in first aid kit NLT 01APR02
Action required: 705 - Other - as specified
Due 1 April 2002
Resolved 26 March 2002
Engineering
Issued 20 March 2002
Resolved
Test bilge pumps and high level alarms prior to carrying passengers.
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 26 March 2002
Engineering
Issued 20 March 2002
Resolved
Test vapor detection system prior to carrying passengers.
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 26 March 2002
Construction/Loadline
Issued 22 March 2000
Resolved
PROVE PROPER OPERATION OF ALL BILGE PUMPS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Navigation
Issued 22 March 2000
Resolved
HORN FAILED TO OPERATE. PROVE PROPER OPERATION OF HORN.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Fire Fighting
Issued 22 March 2000
Resolved
PROVIDE MEANS FOR CLOSING ALL COWLS OR SCOPES FOR SPACES PROVIDED WITH FIXED GAS FIRE SYSTEMS. in accordance with 46CFR 182-15-45.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Navigation
Issued 22 March 2000
Resolved
FORWARD COMBINATION RUNNING LIGHT WIRING LOOSE, LIGHT OPERATION INTERMITENT. PROVE PROPER OPERATION OF RUNNING LIGHT.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Lifesaving
Issued 22 March 2000
Resolved
RETRO REFLECTIVE TAPE PULLED OFF LIFE PRESERVERS. RENEW WORN REFLECTIVE TAPE.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000