MAURY USCG vessel records Sign in
← All vessels

NEPTUNE II

NEPTUNE II is a 1959 passenger vessel (inspected). The Coast Guard has recorded 54 inspections since 1985, most recently in May 2021, along with 79 deficiencies and 2 operational controls.

Records from 1985 to 2021. Most recent: inspection, 24 May 2021.

Built
1959
Last inspected
24 May 2021
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC3843
Flag
UNITED STATES
367015140 (licence lapsed)
Maury page id
psix-44183

Inspections, by type

…with no type recorded4
Years with a record 32 calendar years (1985–2021)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)43.7 ft × 16.1 ft × 6.4 ft
Registered tonnagegross 35 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCRUIZON BOAT WORKS · SURFSIDE, CA, UNITED STATES · built 1959
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLOS ANGELES, CA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it35 - Regulatory (Subpart C or D), Gross Ton
25 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC3843MMSI 367015140 · expired · compulsorily equipped · granted 27 January 2015, cancelled 5 April 2025
WCY7863MMSI not assigned · expired · compulsorily equipped · granted 3 December 1998, cancelled 7 February 2009
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 54

24 May 2021 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7205491
14 January 2020 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6889589
30 October 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6567443
11 October 2018 Hull Examination · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6559417
1 November 2017 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6297877
3 October 2016 DAPI Audit · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6000174
28 September 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6000171
6 August 2015 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5202305
23 October 2014 Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5005911
20 September 2011 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4150158
8 December 2009 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3646939
30 September 2008 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3221321
30 July 2008 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3221318
12 September 2006 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2735451
6 July 2006 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2633984
22 August 2005 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2471266
13 September 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2177796
13 August 2004 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2165078
22 June 2004 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2106928
30 September 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1916335
30 September 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1680203
26 March 2002 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1597398
10 September 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1384891
1 September 2000 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1408588
23 March 2000 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1395390
30 August 1999 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1365349
1 March 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 803710
12 February 1999 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1128524
8 September 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1372352
11 February 1998 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1368587
2 September 1997 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1368371
10 September 1996 Hull Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1385809
30 July 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1090682
5 September 1995 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1358899
20 April 1995 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 857255
24 March 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 828425
9 September 1994 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1178095
13 October 1993 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1142285
30 September 1993 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1154454
30 September 1993 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1155616
30 September 1992 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1268718
22 September 1992 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 936833
23 September 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1310414
17 September 1991 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 936847
28 September 1990 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1230423
3 January 1990 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 923588
29 September 1989 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1016404
30 September 1988 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1195167
7 June 1988 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1199298
8 October 1987 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1321236
19 December 1986 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1335448
15 October 1986 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1009185
16 October 1985 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1302217
10 July 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1299179

Deficiency record · 79

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 January 2020 Resolved
Vessel must complete a satisfactory Annual Inspection prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2020
Resolved 7 October 2020
Resolution: Vessel does not have a valid COI.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 30 October 2018 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2018
Resolved 9 November 2018
Resolution: New sticker was attached.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 30 October 2018 Resolved
During the inspection it was discovered that the vessel was equipped with the required 2 life floats however one of the life floats was missing a paddle. Provide a paddle.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2018
Resolved 9 November 2018
Resolution: A new paddle was placed in service.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 30 October 2018 Resolved
During the inspection it was discovered that the vessels Coast Pilot and Light List were out of date (2017). Provide updates to the Coast Pilot and Light List.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2018
Resolved 9 November 2018
Resolution: Updates the Coast Pilot and Light List were placed in service.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 October 2018 Resolved
Conduct a satisfactory credit for DryDock/Hull examination.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 October 2018
Resolved 24 October 2018
Resolution: Conducted satisfactory credit drydock/hull examination this date, 24OCT2018.
Lifesaving › Lifebuoys › Serviceable
Issued 1 November 2017 Resolved
Replace damaged and worn lifering buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2017
Resolved 7 November 2017
Resolution: Life ring bouy was replaced in kind and the vessels name was permanently affixed.
Engineering › Steering Gear System › Piping
Issued 1 November 2017 Resolved
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2017
Resolved 7 November 2017
Resolution: Steering cable was securly affixed to the overhead.
Communications › Radio Communications › VHF Radiotelephone
Issued 3 October 2016 Resolved
Provide Class D DSC Radio
Action required: 705 - Other - as specified
Due 3 November 2016
Resolved 18 October 2016
Resolution: Installed Class D DSC radio.
Engineering › Bilge Water Management System › Not Operational
Issued 6 August 2015 Resolved
Prove proper operation of fwd and lazerette bilge suction. Correct prior to carrying pax for hire.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 August 2015
Resolution: Crewmembers cleared clogged pipe in fwd compartment, and cleared stuck check valve at manifold for laz compartment.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 6 August 2015 Resolved
Make aft 2 bilge high level alarms audible at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 September 2015
Resolved 18 August 2015
Resolution: Operator made alarms audible at bridge.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 6 August 2015 Resolved
Provide PFD Stowage placard for seat in galley.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 August 2015
Resolution: Crewmembers provided stowage placard for seat.
Construction/Loadline › Penetrations › Valve Flange
Issued 20 September 2011 Resolved
Provide shut-off valve at through hull fittings on starboard side drain pipes.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 20 October 2011
Resolved 12 October 2011
Resolution: Ball valve installed.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 20 September 2011 Resolved
Provide emergency fuel shut-off valve for generator fuel supply.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 20 October 2011
Resolved 30 September 2011
Resolution: Emergency fuel shut-ff installed.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 20 September 2011 Resolved
Provide a means of locking sewage overboard discharge pipe.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 20 October 2011
Resolved 12 October 2011
Resolution: Unlocked overboard pipe was cut and capped off.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 September 2011 Resolved
Post COI and stability letter under glass.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2011
Resolved 12 October 2011
Resolution: CIO installed under glass in accommodation space.
Electrical › Lighting (service) › Lighting Fixture
Issued 20 September 2011 Resolved
Repair or replace light covers in accomodation spaces.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2011
Resolved 30 September 2011
Resolution: New lights installed in accommodation spaces.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 September 2011 Resolved
Replace waterlight for ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2011
Resolved 12 October 2011
Resolution: New water light installed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 20 September 2011 Resolved
Attach waterlight to ring buoy with 3-6' line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2011
Resolved 12 October 2011
Resolution: New line installed.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 20 September 2011 Resolved
Provide retro-reflective tape for life ring. Fixed on the spot.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2011
Resolved 20 September 2011
Resolution: Corrected on the spot
Fire Fighting › Fire Bucket › Availability
Issued 20 September 2011 Resolved
Provide appropriate fire buckets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2011
Resolved 12 October 2011
Resolution: Fire buckets installed.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 20 September 2011 Resolved
Provide hydrostatic release for EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2011
Resolved 12 October 2011
Resolution: New hydro release installed.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 25 August 2005 Resolved
Provide fixed fire fighting report prior to taking passengers.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 September 2005
Resolved 26 August 2005
Resolution: Received fixed fire fighting report.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 August 2005 Resolved
Repair stern navigation light
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2005
Resolved 25 August 2005
Resolution: Stern navigation light bulb replaced-SAT.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 25 August 2005 Resolved
Provide emergency escape hatch placarding on the inside and outside the berthing space hatch.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 August 2005
Resolved 25 August 2005
Resolution: New placard installed.
Deck/Cargo
Issued 21 June 2002 Resolved
Vessel was replacing old rail that did not comply with height requirements of subchapter T. Vessel is installing new rail and courses. At the time of check-ride, rail was incomplete and unsafe. LEGACY COMPONENT DESC: Rails
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 June 2002
Resolution: Vessel called to state rail was completed per discussed plans.
Engineering › Bilge Water Management System
Issued 26 March 2002 Resolved
Worklist Item: Install high level alarm forward of collision bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2002
Resolution: Vessel installed high level alarm, and was satisfactorily tested this date.
Construction/Loadline
Issued 26 March 2002 Resolved
Section's of vessel's deck was rotten, most notably surrounding the pilot house along the port and starboard side. Vessel needs to repair rot prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2002
Resolution: Vessel satisfactorily completed repairs.
Construction/Loadline › Hull
Issued 26 March 2002 Resolved
Repair as necessary the weep in the starboard hull down at the kel, about 10ft at of the bow.
Action required: 705 - Other - as specified
Resolved 5 April 2002
Resolution: Worklist item cleared by [name withheld].
Construction/Loadline › Hull
Issued 26 March 2002 Resolved
Repair delaminating fiberglass on the hull, starboard side amidships, approximately 6 inches up from the keel
Action required: 705 - Other - as specified
Resolved 5 April 2002
Resolution: Cleared by [name withheld].
Construction/Loadline
Issued 26 March 2002 Resolved
Remove and treat rot surrounding old hatch in the overhead starboard side of the lazarette.
Action required: 705 - Other - as specified
Resolved 5 April 2002
Resolution: Cleared by [name withheld].
Construction/Loadline › Hull
Issued 26 March 2002 Resolved
Replace as original, the rotten deck beam in the lazarette overhead; the 4th beam aft of the bulkhead.
Action required: 705 - Other - as specified
Resolved 5 April 2002
Resolution: Cleared by [name withheld].
Construction/Loadline › Hull › Longitudinal Frame
Issued 26 March 2002 Resolved
Replace as original, with marine grade plywood, the delaminating longitudinal in the valve room; it is the 2nd longitudinal outboard of the keel.
Action required: 705 - Other - as specified
Resolved 5 April 2002
Resolution: Cleared by [name withheld]
Construction/Loadline › Penetrations
Issued 26 March 2002 Resolved
Remove and plug th copper pipe/weep hole located in the starboard side of the lazarette, near the shear line.
Action required: 705 - Other - as specified
Resolved 5 April 2002
Resolution: Cleared by [name withheld].
Engineering › Bilge Water Management System › Valve
Issued 26 March 2002 Resolved
Install valve at the hull penetration for all electric bilge pump discharge lines, per 46 CFR 182.520(e)(7).
Action required: 705 - Other - as specified
Resolved 5 April 2002
Resolution: Cleared by [name withheld].
Lifesaving
Issued 10 September 2001 Resolved
ASPIRIN AND AMMONIA INHALANT EXPIRED.
Condition: Unknown
Due 3 October 2001
Resolved 3 October 2001
Engineering
Issued 10 September 2001 Resolved
Provide double-banding on raw water coolant system for starboard main diesel engine, forward of the filter.
Condition: Unknown
Due 3 October 2001
Resolved 3 October 2001
Lifesaving
Issued 10 September 2001 Resolved
Vessel replaced marker lights on two PFDs during the inspection.
Condition: Unknown
Due 3 October 2001
Resolved 3 October 2001
Construction/Loadline
Issued 30 August 1999 Resolved
Install bilge high level alarm with audio and visual alarm at the operatingstation and make available for testing by a marine inspector.
Condition: Unknown
Due 30 August 1999
Resolved 30 August 1999
Engineering
Issued 8 September 1998 Resolved
Provide bonding strap for generator fuel tank deck fitting.
Condition: Unknown
Due 19 September 1998
Resolved 29 September 1998
Engineering
Issued 8 September 1998 Resolved
Repair or renew main fuel tank vent screens.
Condition: Unknown
Due 19 September 1998
Resolved 29 September 1998
Fire Fighting
Issued 8 September 1998 Resolved
Provide required portable fire extinguisher seriviceing prior to carrying passengers for hire.
Condition: Unknown
Due 19 September 1998
Resolved 29 September 1998
Construction/Loadline
Issued 10 September 1996 Resolved
CONDUCT UNDERWAY CHECKRIDE WITH CG INSPECTOR TO EXAMINE STRUCTURAL INTEGRITY.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Engineering
Issued 5 September 1995 Resolved
Replace degraded hoses on electric fuel pumps.
Condition: Unknown
Due 6 September 1995
Resolved 6 September 1995
Lifesaving
Issued 5 September 1995 Resolved
Provide proof of random drug testing program for crew. This item must be completed before passengers are boarded.
Condition: Unknown
Due 6 September 1995
Resolved 6 September 1995
Fire Fighting
Issued 5 September 1995 Resolved
Provide B-I fire extinguisher for pilothouse.
Condition: Unknown
Due 6 September 1995
Resolved 6 September 1995
Construction/Loadline
Issued 24 March 1995 Resolved
PERFORM UNDERWAY DRILL TO OBSERVE INTERNAL SPACES WHILE BOAT IS UNDERWAY ASREQUIRED BY CID POLICY MEMO 2-94.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Navigation
Issued 9 September 1994 Resolved
UPDATE CHARTS, LIGHT LIST, AND COAST PILOT.
Condition: Unknown
Due 9 September 1994
Resolved 9 September 1994
Lifesaving
Issued 9 September 1994 Resolved
PROVIDE FOUR ADULT PFD'S. UNTIL SUCH TIME, PASSENGERS ARE LIMITED TO 16.
Condition: Unknown
Due 9 October 1994
Resolved 9 September 1994
Deck/Cargo
Issued 30 September 1993 Resolved
PROVE THE PROPER OPERATION OF THE ANCHOR WINDLASS.
Condition: Unknown
Due 30 September 1993
Resolved 30 September 1993
Navigation
Issued 30 September 1993 Resolved
PROVIDE AN UP TO DATE COAST PILOT AND COLREGS.
Condition: Unknown
Due 30 September 1993
Resolved 30 September 1993
Navigation
Issued 30 September 1993 Resolved
PROVIDE AN UP TO DATE VERSION OF CHART #18749.
Condition: Unknown
Due 30 September 1993
Resolved 30 September 1993
Accommodation/Occupational Safety
Issued 30 September 1993 Resolved
PROVIDE A LOCKING DEVICE ON THE OVERBOARD DISCHARGE VALVE TO THE MSD.
Condition: Unknown
Due 30 September 1993
Resolved 30 September 1993
Engineering
Issued 22 September 1992 Resolved
PROVIDE PLACARD OR DIAGRAM SHOWING DIRECTIONS TO OPEN/CLOSE FUEL LINE SHUTDOWN VALVES.
Condition: Unknown
Due 22 September 1992
Resolved 22 September 1992
Lifesaving
Issued 22 September 1992 Resolved
PROVIDE EVIDENCE OF PARTICIPATION IN A RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 22 September 1992
Resolved 22 September 1992
Lifesaving
Issued 22 September 1992 Resolved
PROVIDE PARTITION TO SEPARATE ADULT AND CHILD PFD'S IN SHARED LOCKER.
Condition: Unknown
Due 22 September 1992
Resolved 22 September 1992
Accommodation/Occupational Safety
Issued 22 September 1992 Resolved
LABEL MARINE SANITATION DEVICE MACERATOR PUMP SWITCH IN MAIN DECK CONTROL PANEL "DO NOT USE WITHIN THREE MILES OF SHORE".
Condition: Unknown
Due 22 September 1992
Resolved 22 September 1992
Navigation
Issued 22 September 1992 Resolved
PROVIDE COMPASS DEVIATION TABLE, OR ADDITIONAL BACKUP METHOD OTHER THAN MAGNETIC COMPASS NOW ON BOARD TO DETERMINE SHIP'S COURSE.
Condition: Unknown
Due 22 September 1992
Resolved 22 September 1992
Electrical
Issued 22 September 1992 Resolved
DRILL VENTILATION HOLES IN BATTERY BOXES.
Condition: Unknown
Due 22 September 1992
Resolved 22 September 1992
Electrical
Issued 22 September 1992 Resolved
INSTALL METALLIC ELECTRICAL WIRE RUN SUPPORT CLAMPS IN ENGINE ROOM.
Condition: Unknown
Due 22 September 1992
Resolved 22 September 1992
Fire Fighting
Issued 22 September 1992 Resolved
REMOUNT THE B-II PORTABLE FIRE EXTINGUISHER IN THE GALLEY.
Condition: Unknown
Due 22 September 1992
Resolved 22 September 1992
Documentation
Issued 22 September 1992 Resolved
PROVIDE A WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 22 September 1992
Resolved 22 September 1992
Construction/Loadline
Issued 17 September 1991 Resolved
MAKE PERMANENT REPAIRS TO AREAS AS MARKED ON HULL.
Condition: Unknown
Due 17 September 1991
Resolved 17 September 1991
Construction/Loadline
Issued 3 January 1990 Resolved
CROP AND RENEW WORM SHOE IN WAY OF WORM DAMAGE APPROXIMATELY 12 FEET AFT OFSTEM.
Condition: Unknown
Due 3 January 1990
Resolved 3 January 1990
Construction/Loadline
Issued 3 January 1990 Resolved
CLEAN AND TREAT ROT ON UNDERSIDE OF MAIN DECK, OUTBOARD OF AFT ENGINEROOM HATCHES, PORT AND STARBOARD SIDES.
Condition: Unknown
Due 3 January 1990
Resolved 3 January 1990
Documentation
Issued 29 September 1989 Resolved
PROVIDE A VALID RADIOTELEPHONY AND EPIRB CERTIFICATE.
Condition: Unknown
Due 29 September 1989
Resolved 29 September 1989
Engineering
Issued 29 September 1989 Resolved
LABEL BILGE MANIFOLD VALVES.
Condition: Unknown
Due 29 September 1989
Resolved 29 September 1989
Fire Fighting
Issued 29 September 1989 Resolved
PROVIDE A HAND FIRE/BILGE PUMP THAT PUMPS 5 GPM.
Condition: Unknown
Due 29 September 1989
Resolved 29 September 1989
Electrical
Issued 29 September 1989 Resolved
PROVIDE A COVER FOR ELECTRICAL OUTLET ON BRIDGE.
Condition: Unknown
Due 29 September 1989
Resolved 29 September 1989
Construction/Loadline
Issued 30 September 1988 Resolved
REPLACE WINDOW IN PILOT HOUSE DOOR.
Condition: Unknown
Due 30 September 1988
Resolved 30 September 1988
Lifesaving
Issued 30 September 1988 Resolved
STENCIL CAPACITY ON LIFEFLOATS.
Condition: Unknown
Due 30 September 1988
Resolved 30 September 1988
Lifesaving
Issued 30 September 1988 Resolved
ATTACH LIFEFLOAT WATERLIGHT IAW 46 CFR 180.15-5.
Condition: Unknown
Due 30 September 1988
Resolved 30 September 1988
Electrical
Issued 30 September 1988 Resolved
INSTALL BLOCK-OUT IN MAIN CKT BKR PANEL.
Condition: Unknown
Due 30 September 1988
Resolved 30 September 1988
Navigation
Issued 30 September 1988 Resolved
REPAIR AND PROVE PROPER OPERATION OF ANCHOR LIGHT.
Condition: Unknown
Due 30 September 1988
Resolved 30 September 1988
Deck/Cargo
Issued 16 October 1985 Resolved
PROVE THE PROPER OPERATION OF THE ANCHOR NINE-H- BY LIFTING THE ANCHOR.
Condition: Unknown
Due 16 October 1985
Resolved 16 October 1985
Construction/Loadline
Issued 16 October 1985 Resolved
INSTALL A BILGE SYSTEM IN COMPLIANCE WITH 46 CFR 182.25
Condition: Unknown
Due 16 October 1985
Resolved 16 October 1985
Navigation
Issued 10 July 1985 Resolved
REPLACE PORT AND STARBOARD RUNNING LIGHT LENSES.
Condition: Unknown
Due 10 July 1985
Resolved 10 July 1985
Lifesaving
Issued 10 July 1985 Resolved
PROVIDE 3 ADULT PFD'S.
Condition: Unknown
Due 10 July 1985
Resolved 10 July 1985
Unknown
Issued 10 July 1985 Resolved
PROVIDE DOUBLE CLAMP FOR APPROXIMATELY 8 SALT WATER LINES.
Condition: Unknown
Due 10 July 1985
Resolved 10 July 1985
Electrical
Issued 10 July 1985 Resolved
REMOVE LIGHT FIXTURE AND ASSOCIATED WIRING IN LAZERETTE.
Condition: Unknown
Due 10 July 1985
Resolved 10 July 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.