Records from 2001 to 2025. Most recent: inspection, 24 July 2025.
Inspection history · 17
24 July 2025
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8193534
30 May 2024
Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7916434
9 November 2023
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7822680
23 October 2023
In-Service Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7813130
16 May 2023
Deficiency Check · In-Service Inspection · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7692171
2 June 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7465697
27 May 2021
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7208228
29 April 2021
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7184949
28 July 2020
Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6998309
24 January 2020
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6895584
10 June 2019
MTSA Verification · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6706612
26 February 2019
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6653635
29 October 2018
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6571314
14 June 2018
Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6444309
25 May 2018
Plan Review (Other than "T")
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6431187
13 June 2017
Annual Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6174789
16 June 2016
Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5913476
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 29 July 2025
Resolved
Visual and audible alarms must be provided at the operating station to indicate a high water level. Two spaces did not have operable visual or audible alarms.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2025
Resolved 19 August 2025
Resolution: All sat.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 July 2025
Resolved
At each inspection, the bilges and other spaces may be examined to see that there is no excessive oil. The bilges in the engine room had excessive oil in the bilges.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2025
Resolved 19 August 2025
Resolution: All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 May 2024
Resolved
All vessels of 26 feet in length and over shall be
provided with individual bilge lines and bilge suctions
for each watertight compartment. The forepeak tank could
not be dewatered through the fixed bilge suction line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2024
Resolved 28 June 2024
Resolution: Observed sat. bilge pumping from forepeak tank.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 30 May 2024
Resolved
During each certification inspection, verification of
watertight hull and decks is conducted. An approximate
1/2 inch hole was found to fully penetrate the main
deck, just forward of the forepeak hatch. Submit
proposal for temporary and/or permanent repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2024
Resolved 28 June 2024
Resolution: Conducted NDT of cropped and renewed repair, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 May 2024
Resolved
During each certification inspection, verification of
watertight closures in the hull is conducted. The
starboard shaft stuffing box had an excessive leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2024
Resolved 28 June 2024
Resolution: Stuffing box no longer leaking.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 May 2024
Resolved
Each lifering must be approved IAW 160.050, 02 liferings
had grablines that were in poor condition.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2024
Resolved 28 June 2024
Resolution: Life rings were replaced, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 May 2023
Resolved
Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock. Two fuel filters in the generator space were missing flame impingement bowls.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 6 June 2023
Resolution: Impingement bowls were installed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 May 2023
Resolved
At each inspection, the bilges may be examined to see that there is no excessive accumulation of oil, trash or debris. Oily absorbent pads and excess oil were found under both engines.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 6 June 2023
Resolution: Pads and oil were cleaned up.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 June 2022
Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessel's name. (07) life jackets found without proper marking.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 August 2022
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 June 2022
Resolved
Vessel must carry (03) red flares and (03) hand orange smoke signals. Vessel found to have (04) red flares and (03) expired smoke signals.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 August 2022
Resolution: done
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 June 2022
Resolved
Conductors in power and lighting circuits must be No. 14 American Wire Gauge or larger. Decorative lights installed on (02) and (01) decks w/o correct conductor (20 AWG).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 July 2022
Resolution: completed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 June 2022
Resolved
Non-metallic flexible fuel host must be in accordance with SAE J1942. Fuel lines IVO generators wree not SAE J1942.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 July 2022
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 April 2021
Resolved
The vessel is required to have three orange hand flares and three red hand flares OR six red hand flares. Red hand flares onboard are expired. Outfit vessel with at least three hand red flares. Vessel restricted to day time operations until deficiency cleared
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 27 May 2021
Resolution: Cleared onscene
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 April 2021
Resolved
Each child size life jacket must be stored in a location appropriately marked and separated from adult life jackets. Child life jackets are not separated from adult life jackets. Stow child lifejackets so that they are separated from adult life jackets.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 27 May 2021
Resolution: Cleared onscene
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 April 2021
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet but not more than 6 feet. Ring life buoy at operating station had deteriorated lanyard. Replace with appropriate lanyard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 27 May 2021
Resolution: Cleared onscene
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 April 2021
Resolved
Each ring life buoy must be approved in accordnace with Subchapter Q of 46 CFR and be fitted with a grabline around the perimeter. Grabline is deteriorated. Replace in accordance with the requirements of Subchapter Q of 46 CFR.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 27 May 2021
Resolution: Cleared onscene
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 April 2021
Resolved
Gauges for jacket water temperature and engine oil pressure must be readily visible at the operating station. Installed gauges are inoperable. Repair inoperable gauges.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 27 May 2021
Resolution: Cleared onscene
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 29 April 2021
Resolved
Electrical equipment must be installed to protect passengers and crew from electrical shock. Lighting over bar has exposed ligthing sockets. Replace or alter ligting so that risk of electrical shock is eliminated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 27 May 2021
Resolution: Cleared onscene
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 July 2020
Resolved
Collison bulkhead bilge suction is not adequate dewatering due to hole in piping. Vessel needs to make a permanent repair on the piping.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 24 August 2020
Resolution: Vessel had fixed steel piping installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 July 2020
Resolved
Lifejackets amount not correctly identified in containers. All placards and containers must have the correct size and amount of lifejackets stated.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2020
Resolved 11 August 2020
Resolution: All containers have correct size, amount and type of lifejackets stored.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 July 2020
Resolved
Bilge alarms have a cutoff switches that can disable visual/audible alarms. Make the alarms have fixed power without the ability to isolate the alarm at the local panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2020
Resolved 11 August 2020
Resolution: Vessel removed all cutoff switches with no way of disabling the audible and visual alarm.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 July 2020
Resolved
Rudder space alarm is not separated with void 7. Rubber thru hull fittings not below the waterline. Not required to have a bilge alarm in the space. Vessel can remove or separate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2020
Resolved 11 August 2020
Resolution: The bilge alarms was disabled as not required. Void 7 alarm is on its own alarm circuit with no confusion.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 14 June 2018
Resolved
Provide 37 adult and 5 child PFDs. Vessel is restricted to the carriage of 191 adults and 18 child passengers.
Action required: 705 - Other - as specified
Resolved 15 June 2018
Resolution: 37 adult and 5 child PFDs installed.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 14 June 2018
Resolved
Provide FCC Safety Radiotelephony Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2018
Resolved 31 July 2018
Resolution: Received a safety radio certificate.
Engineering › Bilge Water Management System › Interface Detector
Issued 14 June 2018
Resolved
Install highwater alarm in steering void.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2018
Resolved 11 July 2018
Resolution: High water alarm installed.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 16 June 2016
Resolved
Remove/replace FWD Gen cooling hose.
Due 16 July 2016
Resolved 23 June 2016
Resolution: Hose replaced.