Records from 2006 to 2025. Most recent: inspection, 19 September 2025.
Documentation record
Registered dimensions (L × B × D)29.0 ft × 12.0 ft × 5.4 ft
Registered tonnagegross 12 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderISLAND HOPPER INTERNATL · FT PIERCE, FL, UNITED STATES · built 1996
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portTAVERNIER, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
19 September 2025
Plan Review "T" Boat · Internal Structural Exam · Drydock Exam · Administrative Inspection · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8254081
27 March 2025
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8100473
24 April 2024
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7900761
31 October 2023
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7817894
18 January 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7689874
21 September 2022
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7563811
11 April 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7429258
3 February 2022
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7390126
3 January 2022
Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7375058
3 January 2022
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7385898
6 January 2021
In-Service Inspection · COI Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7121120
3 February 2020
Administrative Inspection · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6901754
20 August 2019
DAPI Audit · Annual Inspection · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6808443
29 June 2018
DAPI Audit · Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6557695
8 January 2018
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6465174
16 September 2016
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6004075
2 May 2016
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5807558
13 January 2016
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5799140
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 September 2025
No resolution recorded
The Owner/Operator of the vessel must consult with the cognizant OCMI zone in which the vessel intends to operate and conduct a new to zone inspection prior to carrying passengers.
46 CFR 176.404
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 January 2023
Resolved
Drydock inspection was stopped halfway through as vessel was not completely ready for inspection. Must finish drydock inspection and make all repairs prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 July 2024
Resolved 2 July 2024
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 April 2022
Resolved
Eye wash in first aid kit was expired. Replace eye wash.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2022
Resolved 13 April 2022
Resolution: New eye wash onboard
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 April 2022
Resolved
CG approved NAV chart has a print date of 1995 with no chart corrections. GPS is not updated with latest charts. Must either buy new CG approve NAV chart, make all chart corrections on current chart on board since print date, or update GPS with latest NAV Chart software.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2022
Resolved 13 April 2022
Resolution: Latest NAV Chart update was downloaded onto GPS
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 January 2022
Resolved
MDE shutdown while transiting to reef with passengers onboard. Must conduct repairs and test to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2022
Resolution: Replaced connection on ground wire for fireboy system. Test MDE and fireboy system, test SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 January 2021
Resolved
Vessel Failed to have annual inspection completed for 2020. Vessel must have COI inspection prior to carrying passengers
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 6 January 2021
Resolved 22 January 2021
Resolution: completed COI inspection
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 January 2021
Resolved
Fireboy system not operating as it should. It will shut down the engine and prevent starting without hitting override switch. However, it wont re start the engine after hitting override. Make repairs and test to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2021
Resolved 18 February 2021
Resolution: Installed new fireboy system. Tested SAT
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 January 2021
Resolved
Vessel only has 3 orange flares which expired last yr. Must have 6 orange hand held flares prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 January 2021
Resolved 26 January 2021
Resolution: Bought all new orange flares
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 January 2021
Resolved
Vessel is missing 1 of 3 fire buckets required. Replace missing fire bucket and label as required.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2021
Resolved 18 February 2021
Resolution: Bought new fire bucket, 3 total onboard
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 6 January 2021
Resolved
Life Floast is faded pretty bad. Need to repaint with approved international orange paint.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2021
Resolved 18 February 2021
Resolution: Painted and labeled life float with vessel name and passenger count
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 January 2021
Resolved
Vessel has no paper chart and Garmin GPS is not updated with the latest software. Must have current updated approved paper chart or update GPS to lasted software version.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2021
Resolved 18 February 2021
Resolution: Updated Garmin to latest software
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 January 2021
Resolved
Make new logs to properly log Crew Training, MOB and Fire drills as required.
46 CFR 185.420
46 CFR 185.520
46 CFR 185.524
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2021
Resolved 11 February 2021
Resolution: Added more info to log as required
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 January 2021
Resolved
6 Adult life jackets needs retro tape replaced. Must replace with SOLAS retro tape
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2021
Resolved 18 February 2021
Resolution: replaced retro tape to all life jackets
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 6 January 2021
Resolved
Alcohol swaps were expired. Must replace with enough to test entire crew at once.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2021
Resolved 18 February 2021
Resolution: New alcohol swabs expire 8-2021
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 20 August 2019
Resolved
Vessel is missing 1 orange smoke flare. Renew with 1 orange or 1 red.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 September 2019
Resolution: New flares were purchased.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 August 2019
Resolved
Anchor light is extinguished. Renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 September 2019
Resolution: Anchor light was renewed.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 20 August 2019
Resolved
VHF does not have GPS input. Provide proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 September 2019
Resolution: GPS has been linked to VHF radio.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 20 August 2019
Resolved
Renew life-ring lanyard to the strobe.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 September 2019
Resolution: Life-ring lanyard has been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 20 August 2019
Resolved
Both paddles in life float must have vessel name.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 September 2019
Resolution: Vessel name has been written on life float paddles.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 August 2019
Resolved
STBD stantion of Bimini top is cracked. Clean and weld. Allow further inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 September 2019
Resolution: Crack on STBD bimini top stantion has been welded and corrected.