AQUATIC DIVER

AQUATIC DIVER is a 1996 passenger vessel (inspected). The Coast Guard has recorded 52 inspections since 1996, most recently in September 2025, along with 83 deficiencies — 1 with no resolution recorded —, 3 operational controls and 5 casualty investigations between 2006 and 2022.

Records from 1996 to 2025. Most recent: inspection, 19 September 2025.

Built
1996
Last inspected
19 September 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

441869
Flag
UNITED STATES
367772660
Maury page id
psix-441869

Inspections, by type

…with no type recorded4
Years with a record 25 calendar years (1996–2025)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)29.0 ft × 12.0 ft × 5.4 ft
Registered tonnagegross 12 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderISLAND HOPPER INTERNATL · FT PIERCE, FL, UNITED STATES · built 1996
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portTAVERNIER, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ3921MMSI 367772660 · active · compulsorily equipped · granted 11 February 2017, expires 11 February 2027
WCW8409MMSI not assigned · expired · compulsorily equipped · granted 6 September 1996, cancelled 13 November 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 52

19 September 2025 Plan Review "T" Boat · Internal Structural Exam · Drydock Exam · Administrative Inspection · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8254081
27 March 2025 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8100473
24 April 2024 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7900761
31 October 2023 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7817894
18 January 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7689874
21 September 2022 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7563811
11 April 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7429258
3 February 2022 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7390126
3 January 2022 Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7375058
3 January 2022 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7385898
6 January 2021 In-Service Inspection · COI Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7121120
3 February 2020 Administrative Inspection · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6901754
20 August 2019 DAPI Audit · Annual Inspection · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6808443
29 June 2018 DAPI Audit · Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6557695
8 January 2018 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6465174
16 September 2016 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6004075
2 May 2016 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5807558
13 January 2016 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5799140
9 September 2015 Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5233974
6 June 2012 Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4335848
20 January 2012 Deficiency Check · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4278070
14 September 2011 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4145064
22 July 2008 Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3275575
24 June 2008 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3246596
10 July 2007 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2990670
10 July 2007 Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2990744
25 June 2007 COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2973155
14 March 2007 Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2887728
12 August 2006 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2747501
21 July 2006 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2720000
13 July 2005 Simplified Stability Test · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2447695
1 July 2005 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2410189
23 June 2005 Deficiency Check · Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2323195
19 July 2004 Annual Inspection · Deficiency Check · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2137872
10 June 2003 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1813739
29 July 2002 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1653440
16 July 2002 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1646878
24 June 2002 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1635360
28 September 2001 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1074053
30 July 2001 Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1069386
28 June 2001 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1068690
7 June 2001 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1439227
21 July 2000 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1410362
21 June 2000 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1395477
8 July 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1091748
24 June 1999 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1420155
22 October 1998 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 804154
4 August 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1424625
20 July 1998 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 794996
12 August 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 782043
19 July 1996 Initial Certification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1086914
31 May 1996 Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1090635

Deficiency record · 83

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 September 2025 No resolution recorded
The Owner/Operator of the vessel must consult with the cognizant OCMI zone in which the vessel intends to operate and conduct a new to zone inspection prior to carrying passengers. 46 CFR 176.404
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 January 2023 Resolved
Drydock inspection was stopped halfway through as vessel was not completely ready for inspection. Must finish drydock inspection and make all repairs prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 July 2024
Resolved 2 July 2024
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 April 2022 Resolved
Eye wash in first aid kit was expired. Replace eye wash.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2022
Resolved 13 April 2022
Resolution: New eye wash onboard
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 April 2022 Resolved
CG approved NAV chart has a print date of 1995 with no chart corrections. GPS is not updated with latest charts. Must either buy new CG approve NAV chart, make all chart corrections on current chart on board since print date, or update GPS with latest NAV Chart software.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2022
Resolved 13 April 2022
Resolution: Latest NAV Chart update was downloaded onto GPS
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 January 2022 Resolved
MDE shutdown while transiting to reef with passengers onboard. Must conduct repairs and test to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2022
Resolution: Replaced connection on ground wire for fireboy system. Test MDE and fireboy system, test SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 January 2021 Resolved
Vessel Failed to have annual inspection completed for 2020. Vessel must have COI inspection prior to carrying passengers
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 6 January 2021
Resolved 22 January 2021
Resolution: completed COI inspection
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 January 2021 Resolved
Fireboy system not operating as it should. It will shut down the engine and prevent starting without hitting override switch. However, it wont re start the engine after hitting override. Make repairs and test to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2021
Resolved 18 February 2021
Resolution: Installed new fireboy system. Tested SAT
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 January 2021 Resolved
Vessel only has 3 orange flares which expired last yr. Must have 6 orange hand held flares prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 January 2021
Resolved 26 January 2021
Resolution: Bought all new orange flares
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 January 2021 Resolved
Vessel is missing 1 of 3 fire buckets required. Replace missing fire bucket and label as required.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2021
Resolved 18 February 2021
Resolution: Bought new fire bucket, 3 total onboard
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 6 January 2021 Resolved
Life Floast is faded pretty bad. Need to repaint with approved international orange paint.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2021
Resolved 18 February 2021
Resolution: Painted and labeled life float with vessel name and passenger count
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 January 2021 Resolved
Vessel has no paper chart and Garmin GPS is not updated with the latest software. Must have current updated approved paper chart or update GPS to lasted software version.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2021
Resolved 18 February 2021
Resolution: Updated Garmin to latest software
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 January 2021 Resolved
Make new logs to properly log Crew Training, MOB and Fire drills as required. 46 CFR 185.420 46 CFR 185.520 46 CFR 185.524
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2021
Resolved 11 February 2021
Resolution: Added more info to log as required
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 January 2021 Resolved
6 Adult life jackets needs retro tape replaced. Must replace with SOLAS retro tape
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2021
Resolved 18 February 2021
Resolution: replaced retro tape to all life jackets
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 6 January 2021 Resolved
Alcohol swaps were expired. Must replace with enough to test entire crew at once.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2021
Resolved 18 February 2021
Resolution: New alcohol swabs expire 8-2021
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 20 August 2019 Resolved
Vessel is missing 1 orange smoke flare. Renew with 1 orange or 1 red.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 September 2019
Resolution: New flares were purchased.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 August 2019 Resolved
Anchor light is extinguished. Renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 September 2019
Resolution: Anchor light was renewed.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 20 August 2019 Resolved
VHF does not have GPS input. Provide proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 September 2019
Resolution: GPS has been linked to VHF radio.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 20 August 2019 Resolved
Renew life-ring lanyard to the strobe.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 September 2019
Resolution: Life-ring lanyard has been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 20 August 2019 Resolved
Both paddles in life float must have vessel name.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 September 2019
Resolution: Vessel name has been written on life float paddles.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 August 2019 Resolved
STBD stantion of Bimini top is cracked. Clean and weld. Allow further inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 September 2019
Resolution: Crack on STBD bimini top stantion has been welded and corrected.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 6 June 2012 Resolved
Renew retroreflective material on all life jackets as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2012
Resolved 20 July 2012
Resolution: All retro replaced as needed. All sat.
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 June 2012 Resolved
Label bilge alarm indicators on console.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2012
Resolved 20 July 2012
Resolution: Bilge alarms properly labeled. All sat.
Construction/Loadline › Penetrations › Valve Flange
Issued 6 June 2012 Resolved
Remove old sewage discharge valve and properly cap.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2012
Resolved 20 July 2012
Resolution: Valve flange properly capped off. All sat.
Stability › Watertight Integrity › General
Issued 20 January 2012 Resolved
Repair forward main deck hatch latches and renew gasket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 February 2012
Resolved 20 February 2012
Resolution: Hatch properly repaired.
Stability › Watertight Integrity › General
Issued 20 January 2012 Resolved
Provide backing plates on engine hatch hinges.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 20 February 2012
Resolved 20 February 2012
Resolution: Backing plates installed.
Stability › Watertight Integrity › General
Issued 20 January 2012 Resolved
Provide indicator on hatch latches to indicate when in closed position.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 20 February 2012
Resolved 20 February 2012
Resolution: Latches marked to indicate closed position.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 20 January 2012 Resolved
Stow life jackets in readily accessible location on main deck, may not stow in forward cabin.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 February 2012
Resolved 20 February 2012
Resolution: Life jackets properly stowed.
Engineering › Fuel Oil Service System › Hose
Issued 20 January 2012 Resolved
Fuel hose is not CG approved for commercial vessel use, replace with approved type fuel hose or metal piping in accordance with 46 CFR 182.455.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 March 2012
Resolved 30 March 2012
Resolution: New CG approved fuel hose installed.
Lifesaving › Lifefloat › Serviceable
Issued 14 September 2011 Resolved
Lifefloat is unserviceable repair or replace as needed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2011
Resolved 15 September 2011
Resolution: New Lifefloat properly installed on vessel.
Lifesaving › Lifefloat › Float-free Link
Issued 14 September 2011 Resolved
Install weak link on Lifefloat painter line, vessel is restricted to operations in less than 80 feet of water until weak link is installed.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 October 2011
Resolved 15 September 2011
Resolution: New weak link and painter line properly installed on Lifefloat.
Stability › Watertight Integrity › General
Issued 14 September 2011 Resolved
Renew hatch gasket on forward deck hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 October 2011
Resolved 21 October 2011
Resolution: New hatch gasket installed.
Stability › Freeing Ports › General
Issued 14 September 2011 Resolved
Install transom door and non-return devices on all freeing ports in transom of vessel. Vessels deck is less than 10 inches above the LWL.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 October 2011
Resolved 21 October 2011
Resolution: New transom door fabricated and installed, all scuppers have non-return devices installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 September 2011 Resolved
All nav lights are inop. Vessel is restricted from operation during restricted visibility.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 October 2011
Resolved 21 October 2011
Resolution: All new nav lights installed and working properly.
Engineering › Fuel Oil Service System › Filter
Issued 14 September 2011 Resolved
Provide flame shield on fuel filter assembly, may use solid metal filter bowl.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 October 2011
Resolved 21 October 2011
Resolution: New metal filter bowl installed. All sat.
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 July 2007 Resolved
Replace metal hose clamps on raw water/exhaust hose.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 August 2007
Resolved 11 July 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 July 2007 Resolved
Prove servicing or replacement of starting bateries.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 August 2007
Resolved 11 July 2007
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 25 June 2007 Resolved
Provide (01) adult type I PFD; passenger count restricted to 23.
Action required: 705 - Other - as specified
Due 25 July 2007
Resolved 25 June 2008
Lifesaving › Lifebuoys › Serviceable
Issued 25 June 2007 Resolved
Replace ring lifebouy.
Action required: 705 - Other - as specified
Due 25 July 2007
Resolved 25 June 2008
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 25 June 2007 Resolved
Provide Hydro-static release for EPIRP.
Action required: 705 - Other - as specified
Due 29 June 2007
Resolved 28 June 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 July 2006 Resolved
Replace lanyard on life buoy water light, 3-6 ft length.
Action required: 705 - Other - as specified
Due 21 August 2006
Resolved 14 March 2007
Fire Fighting › Fire Bucket › Quantity
Issued 21 July 2006 Resolved
Provide three 2.5 gallon fire buckets with attached lanyard and labled "FIRE BUCKET" IAW 46 CFR 181.610
Action required: 705 - Other - as specified
Due 21 August 2006
Resolved 14 March 2007
Stability › Incline Test › General
Issued 22 July 2005 Resolved
Vessel is limited to 12 passengers with dive equipment and 2 crew members until stability calculations are approved by MSC.
Action required: 705 - Other - as specified
Due 22 August 2005
Resolved 17 October 2005
Resolution: MSC reviewed stability calculations and issued new stability letter.
Stability › Incline Test › General
Issued 13 July 2005 Resolved
Vessel is limited to six passengers until stability of vessel is proved.
Action required: 705 - Other - as specified
Due 13 August 2005
Resolved 22 July 2005
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 23 June 2005 Resolved
Renew one adult size PFD.
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 13 July 2005
Operations/Management › Drills/Instruction › Flooding Mitigation
Issued 23 June 2005 Resolved
Renew Emergency Instruction List.
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 13 July 2005
Documentation › Markings/Placards › Lifejacket Placard
Issued 23 June 2005 Resolved
Renew PFD Donning Placard.
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 13 July 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 June 2005 Resolved
Repair waterlight for ringbuoy.
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 13 July 2005
Lifesaving › Lifefloat › Float-free Link
Issued 23 June 2005 Resolved
Properly attach Painter and weak link to Lifefloat.
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 13 July 2005
Lifesaving › Lifefloat › Markings
Issued 23 June 2005 Resolved
Properly stencil vessel's name and capacity on Lifefloat.
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 13 July 2005
Lifesaving › Lifefloat › Paddle
Issued 23 June 2005 Resolved
Stencil vessel's name on paddles for Lifefloat and properly lash paddles to Lifefloat.
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 23 June 2005
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 23 June 2005 Resolved
Provide and post Emergency Radio Broadcast Placard.
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 13 July 2005
Engineering › Bilge Water Management System › Pump
Issued 23 June 2005 Resolved
Repair bilge pump located in forward section of engine compartment.
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 13 July 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 June 2005 Resolved
Provide a USCG Approved First Aid Kit Approval #160.041.
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 23 June 2005
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 23 June 2005 Resolved
Provide a logbook with proper entries for conducting emergency drills and testing EPIRB.
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 13 July 2005
Documentation › Certificates/Documents › FCC SSL
Issued 12 August 2004 Resolved
Provide an FCC Safety Radio Certificate onboard.
Due 12 September 2004
Resolved 23 June 2005
Resolution: Completed.
Personnel › Training › Familiarization Training
Issued 12 August 2004 Resolved
Provide documentation of drills and training for each crew person.
Due 12 September 2004
Resolved 23 June 2005
Resolution: Cleared and re-written as a requirement.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 August 2004 Resolved
Provide a complete first aid kit.
Due 12 September 2004
Resolved 23 June 2005
Resolution: Cleared and re-written as a requirement.
Engineering › Steering Gear System › Pump
Issued 12 August 2004 Resolved
Found upper steering station helm hydraulic steering wheel with slight leak. Repaired same day by replacing o-ring.
Due 12 August 2004
Resolved 12 August 2004
Construction/Loadline › Structures › Scuttle
Issued 19 July 2004 Resolved
Prove water tight aft deck hatch.
Due 19 August 2004
Resolved 12 August 2004
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 19 July 2004 Resolved
Clean fittings at fuel tank, prepare for close up inspection.
Due 19 August 2004
Resolved 12 August 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 19 July 2004 Resolved
Tighten engine mount bolts.
Due 19 August 2004
Resolved 12 August 2004
Engineering › Bilge Water Management System › Piping
Issued 19 July 2004 Resolved
Prove bilge de-watering system in all compartments.
Due 19 August 2004
Resolved 12 August 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 July 2004 Resolved
Repair or remove dead ended cables and wasted wiring.
Due 19 August 2004
Resolved 12 August 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 19 July 2004 Resolved
Repair broken hand rail at starboard side.
Due 19 August 2004
Resolved 12 August 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 10 June 2003 Resolved
Install/Replace BII fire extinguisher near lower helm station.
Condition: Unknown
Due 13 June 2003
Resolved 19 July 2004
Engineering › Sea-water System (primary cooling)
Issued 16 July 2002 Resolved
Renew main engine raw water valve handle. LEGACY COMPONENT DESC: Valve Handle
Condition: Improper Installation
Due 25 July 2002
Resolved 23 July 2002
Engineering › Shafting/Propeller Arrangements
Issued 16 July 2002 Resolved
Renew shaft cutlass bearing. LEGACY COMPONENT DESC: Strut Bearing
Condition: Improper/Lack of Maintenance
Due 25 July 2002
Resolved 23 July 2002
Engineering
Issued 30 July 2001 Resolved
Make proper repairs and conduct satisfactory test of MDE in prescence of USCG Marine Inspector prior to carry passengers.
Condition: Unknown
Due 30 July 2001
Resolved 30 July 2001
Accommodation/Occupational Safety
Issued 7 June 2001 Resolved
Provide bull horn or speaker for public address system.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Navigation
Issued 7 June 2001 Resolved
Provide all up to date navigational publications.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Documentation
Issued 7 June 2001 Resolved
Provide current training log with proper/required entries.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Lifesaving
Issued 7 June 2001 Resolved
Provide PFD donning placard.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Construction/Loadline
Issued 7 June 2001 Resolved
Provide high level bilge alarm and visual indicator at upper operating station.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Lifesaving
Issued 7 June 2001 Resolved
Repair tears in life float & replace retro-reflective tape.
Condition: Unknown
Due 7 June 2001
Resolved 7 June 2001
Construction/Loadline
Issued 21 June 2000 Resolved
Provide high level alarm for aft steering bilge, IAW T regs._x001C_ To be completed by 28JUN00
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Fire Fighting
Issued 24 June 1999 Resolved
Prior to 08Jul99, provide means of closing off ventilation to the engine room to prevent the escape of fire extinguishing agent, if need be.
Condition: Unknown
Due 8 July 1999
Resolved 12 July 1999
Fire Fighting
Issued 24 June 1999 Resolved
Prior to 08Jul99, provide a manual pull station for the fixed fire fightingextinguishing system IAW 46CFR181.420(a)(2).
Condition: Unknown
Due 8 July 1999
Resolved 12 July 1999
Navigation
Issued 4 August 1998 Resolved
Prior to 18AUG98, provide a quick disconnect for steering actuator to rudder post.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Engineering
Issued 4 August 1998 Resolved
Prior to 18AUG98, provide quick disconnect linkage on engine speed and direction of shaft rotation.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Accommodation/Occupational Safety
Issued 4 August 1998 Resolved
Prior to 18AUG98, Provide a Drill Log for man overboard and fire drills.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Accommodation/Occupational Safety
Issued 4 August 1998 Resolved
Prior to 18AUG98, provide a rewritten man overboard drill procedure to match vessels construction.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Accommodation/Occupational Safety
Issued 4 August 1998 Resolved
Prior to 18AUG98, provide proper proof of required documents for a Drug Testing Program.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Fire Fighting
Issued 4 August 1998 Resolved
Prior to 18AUG98, provide one B-I portable fire extinguisher at upper operating station.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998

Casualty record · 5

12 August 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2747501
10 July 2007Routine · role: Involved in a Marine Casualty · activity 2990670
23 May 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3916915
21 May 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4019768
3 January 2022Routine · role: Involved in a Marine Casualty · activity 7385898
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

AQUATICDIVER (2006–2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.