Inspection history · 88
11 September 2025
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8229243
17 October 2024
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8008936
28 August 2023
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7771430
21 September 2022
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7559388
22 September 2021
Internal Structural Exam · COI Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7317173
8 October 2020
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7069362
6 September 2019
Administrative Inspection · Periodic Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6805564
16 August 2019
Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6785377
17 October 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6561340
27 September 2017
Administrative Inspection · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6275989
6 March 2017
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6220120
8 September 2016
Internal Structural Exam · Administrative Inspection · Hull Examination · Cargo Tank Internal · COI Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5995640
9 September 2015
COI Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5733292
30 September 2014
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4995821
25 July 2014
Damage Survey
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4933568
25 July 2014
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4939445
17 September 2013
Administrative Inspection · Periodic Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4716118
28 September 2012
Deficiency Check · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4452498
20 September 2012
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4437373
24 January 2012
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4230755
26 August 2011
Annual Inspection · MTSA Verification · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4132877
23 August 2011
VRP Drill
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4131650
9 September 2010
MTSA Verification · COI Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3828434
15 September 2009
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3594166
10 June 2009
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3500892
5 June 2009
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3498380
29 October 2008
Periodic Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3358243
20 November 2007
Re-Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3103011
28 August 2006
Hull Examination · MTSA Verification · Annual Inspection · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2789713
28 October 2005
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2523812
9 September 2005
COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2523080
15 March 2005
MTSA Verification
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2310553
27 August 2004
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2178318
27 August 2004
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2178347
16 August 2004
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2167807
8 June 2004
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2093322
21 July 2003
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1852895
6 August 2002
Periodic Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1657562
23 August 2001
Re-Inspection · Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1463700
24 January 2001
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 287341
24 August 2000
Deficiency Check · COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1389170
1 September 1999
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1432198
2 September 1998
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1461087
15 April 1998
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 130807
23 December 1997
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 480212
9 October 1997
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1460121
7 June 1997
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 447772
2 October 1996
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 835801
9 September 1996
Hull Examination · COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1388117
23 April 1996
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1080586
17 February 1996
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 443253
3 May 1995
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 909313
28 March 1995
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 833020
2 December 1994
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 8173
19 May 1994
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 859683
12 April 1994
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 860108
2 April 1993
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1457089
11 February 1992
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1266807
6 February 1992
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 473253
6 February 1992
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 950771
26 July 1991
Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 931871
15 May 1991
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1215640
2 April 1991
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 929191
5 November 1990
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1213557
9 July 1990
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 932046
1 May 1990
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1240083
30 August 1989
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1037678
8 June 1989
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 888254
11 April 1989
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 891446
8 June 1988
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 890968
10 May 1988
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 538336
18 November 1987
Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1333785
2 October 1987
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 509781
12 May 1987
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1023468
30 May 1986
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1300634
1 August 1985
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 452037
14 June 1985
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 983819
17 May 1985
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 500619
10 May 1985
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 465069
10 March 1985
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 491342
22 January 1985
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 458318
22 January 1985
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 492629
12 December 1984
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 538564
5 December 1984
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 438192
19 October 1984
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 531113
27 September 1984
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 520698
5 May 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271221
28 May 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969991
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 August 2019
Resolved
No extensive alterations involving the safety of a tank vessel shall be made without approval. Before such alterations are carried out, copies of plans and specifications for the work involved shall be forwarded to the Officer in Charge, Marine Inspection, in whose zone the repairs will be made; Vessel is authorized offload current cargo and not authorized to load cargo until a hull and internal structural exam has been carried out on #1 port void and repairs have been made on damaged section to the satisfaction of an attending CG Marine Inspector.
Company must notify OCMI prior to departure from Wooten's River Service and must notify local OCMI upon arrival to the drydock, current planned location at 5M Transportation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2019
Resolution: The repair was inspected and approved.
Construction/Loadline › Structures › Rake
Issued 25 July 2014
Resolved
Val shall not load cargo. Vsl shall proceed to marine builders shipyard for permanent repairs to the stbd bow rake.
Action required: 705 - Other - as specified
Due 30 July 2014
Resolved 31 July 2014
Resolution: Conducted visual and NDT inspection of a 3''x4'' insert on the stbd head long. Used 2 psi air by monometer and soap test with satisfactory results.
Electrical › Lighting (service) › Lighting Fixture
Issued 20 September 2012
Resolved
Found over head light fixture bracket to be broken, repair/replace broken bracket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 September 2012
Resolved 28 September 2012
Resolution: Light and conduit properly supported by bracket.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 20 September 2012
Resolved
Found exhaust pipe on pump engine to be leaking, determine source and properly repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 September 2012
Resolved 28 September 2012
Resolution: Exhaust pipe coupling replaced and secured
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 20 September 2012
Resolved
Found wires leading to Emergency shutdown solenoid to have cracked insulation and exposed wire, replace wire.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 September 2012
Resolved 28 September 2012
Resolution: Installed new wire run.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 29 October 2008
Resolved
Replace closed gaging sounding sticks, 02 total.
Due 29 November 2008
Resolved 4 November 2008
Resolution: Replaced with new.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 19 September 2005
Resolved
Prove to local OCMI compliance with 46 CFR 111.105-31(l).
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 19 March 2006
Resolved 27 October 2005
Resolution: Per discussion with CID following receipt of letter from operator regarding requirement, vessel cargo authority was reduced to Grade E Cargo with the only exception being #2 diesel fuel oil with a flashpoint above 140 degrees.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 September 2005
Resolved
Repaint navigation light screens with a flat black coating.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2005
Resolved 27 October 2005
Resolution: Observed flat black background on nav light screens.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 9 September 2005
Resolved
Replace overfill dipstick in both slop tank high level gauges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2005
Resolved 27 October 2005
Resolution: Observed new dipsticks in place.
Documentation › Logs/Records › Declaration of Inspection
Issued 9 September 2005
Resolved
Rewrite Declaration Of Inspection used by tankerman so copies are readable.
Action required: 705 - Other - as specified
Due 9 October 2005
Resolved 27 October 2005
Resolution: Observed readable copy of DOI in use.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 16 August 2004
Resolved
Provide Valid Certificate of Financial Responsibility, Barge operations is suspended until proof of a valid certificate is provided.
Condition: Unknown
Due 16 September 2004
Resolved 27 August 2004
Resolution: Received copy of new COFR certificate.
Engineering
Issued 24 January 2001
Resolved
TEST PRESSURE MARKED ON HOSE DURING TRANSFER.
Condition: Unknown
Due 8 February 2001
Resolved 15 March 2001
Lifesaving
Issued 24 August 2000
Resolved
PROPERLY MOUNT POTABLE WATER TRANSFER PUMP TO PUMP SUPPORT.
Condition: Unknown
Due 21 September 2000
Resolved 21 September 2000
Deck/Cargo
Issued 24 August 2000
Resolved
PROPERLY ATTACH AIR SEPARATOR VENT LINE USING APPROPRIATE PIPING SUPPORTS.
Condition: Unknown
Due 21 September 2000
Resolved 21 September 2000
Deck/Cargo
Issued 24 August 2000
Resolved
REPLACE PLASTIC BUCKETS BEING USED AS PORTABLE CONTAINMENT WITH STEEL.
Condition: Unknown
Due 21 September 2000
Resolved 21 September 2000
Deck/Cargo
Issued 9 September 1996
Resolved
CARGO PUMP MOTORS WERE NOT ON BOARD VESSEL DUE TO MOTORS BEING OVERHAULED. MOTORS WILL BE REPLACED WHEN VESSEL RETURNS TO LOUISVILLE, KY.
Condition: Unknown
Due 9 September 1996
Resolved 9 September 1996
Deck/Cargo
Issued 9 September 1996
Resolved
EMERGENCY SHUTDOWNS WERE NOT TESTED DUE TO CARGO PUMP MOTORS NOT BEING ON BOARD AT THE TIME OF THE INSPECTION.
Condition: Unknown
Due 9 September 1996
Resolved 9 September 1996
Construction/Loadline
Issued 28 March 1995
Resolved
MAKE ALL FLUSH DECK VOID HATCHES WATER TIGHT.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Electrical
Issued 12 April 1994
Resolved
SECURE THE STARTING BATTERY BOX ON THE CARGO PUMP ENGINE.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Engineering
Issued 12 April 1994
Resolved
REPLACE FLAME SCREEN ON THE CARGO ENGINE FUEL TANK.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Deck/Cargo
Issued 12 April 1994
Resolved
REPLACE CAMLOCK GASKET ON THE PORT FORWARD CARGO TRANSFER HOSE.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Deck/Cargo
Issued 12 April 1994
Resolved
INSTALL BLANK FLANGE ON 3" SLOP OIL PIPING IN WAY OF MISSING METER ASSEMBLY.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Engineering
Issued 12 April 1994
Resolved
REPLACE FUEL OIL SUPPLY HOSE FEEDING THE CARGO PUMP.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Deck/Cargo
Issued 12 April 1994
Resolved
INSTALL BOLTS ON CENTER DECK SLOP TANK MANHOLE COVER.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Deck/Cargo
Issued 2 April 1993
Resolved
REPLACE ALL FLAME SCREENS IN THE PV VALVES AND ULLAGE HOLES WITH FLAME SCREEN OF 30x30 MESH._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Engineering
Issued 2 April 1993
Resolved
INSTALL APPROVED FUEL OIL LINES FROM THE FUEL OIL TANK TO THE DIESEL PUMP ENGINE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Deck/Cargo
Issued 6 February 1992
Resolved
Clean flame screens inside the PV vents of all cargo tanks as required by 46CFR32.55-20(d) and 46CFR32.20-5 prior to compliance date.
Condition: Unknown
Due 6 February 1992
Resolved 6 February 1992
Fire Fighting
Issued 2 April 1991
Resolved
Provide "Marine Approval" label on all portable fire extinguishers as required by 46CFR162.028-4; prior to compliance date.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Engineering
Issued 2 April 1991
Resolved
Install a vent pipe and flame screen on fuel oil tank for cargo pump engineas required by 46CFR56.50-85(a)(2)(7); prior to compliance date.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Deck/Cargo
Issued 2 April 1991
Resolved
Hydrostatically test all oil transfer hoses to 1 1/2 times the maximum allowable working pressure (MAWP) as required by 33CFR156.170(c)(1)(iii); prior to compliance date.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Deck/Cargo
Issued 2 April 1991
Resolved
Mark all hoses used for oil transfer operations with the maximum allowable working pressure (MAWP) and the words "Oil Service" as described in 33CFR154.500(e)(1)(2) and as required by 33CFR155.800; prior to compliance date.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Deck/Cargo
Issued 2 April 1991
Resolved
Provide records for each oil transfer hose showing hydrostatic test date and test pressure, manufacturing date, and burst pressure as described in 33CFR154.500(e)(g) and as required by 33CFR155.820(c); prior to compliance date.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Deck/Cargo
Issued 2 April 1991
Resolved
Provide fixed containment under cargo transfer manifold on stbd bow as required by 33CFR155.310(a)(1)(ii); prior to compliance date.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Construction/Loadline
Issued 2 April 1991
Resolved
Replace missing gaskets on hatch covers to #2 stbd, #4 stbd, #4 port, #3 port, and #2 port wing voids and the stern void as required by 46CFR172.050(b); prior to compliance date.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Construction/Loadline
Issued 2 April 1991
Resolved
Reattach captive chains to hatch covers on #3 stbd, #4 stbd, #4 port, and #2 port wing voids and the stern void prior to compliance date.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Construction/Loadline
Issued 2 April 1991
Resolved
Make permanent repairs to a fourteen (14) inch crack on the sideshell at corner on the stbd bow, and intersected by a ten (10) inch crack prior to compliance date.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Deck/Cargo
Issued 2 April 1991
Resolved
Replace holed flame screen in the #3 stbd cargo tank PV vent as required by46CFR30.10-25 and 46CFR162.017-3(n); prior to compliance date.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Deck/Cargo
Issued 2 April 1991
Resolved
Clean flame screens in gooseneck vents on all deck lube oil tanks and on the #2 stbd cargo tank PV vent as required by 46CFR32.55-20(d) and 46CFR32.20-5; prior to compliance date.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Deck/Cargo
Issued 2 April 1991
Resolved
Replace missing gaskets on PV vents to all cargo tanks as required by 46CFR32.20-5 and 46CFR162.017-3(f); prior to compliance date.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Construction/Loadline
Issued 2 April 1991
Resolved
Make permanent repairs to a four (4) inch crack in deck on port bow prior to compliance date.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Deck/Cargo
Issued 2 April 1991
Resolved
Replace weights in #1 stbd cargo tank PV Vent as required by 46CFR32.20-5 and 46CFR162.017-3(i); prior to compliance date.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Electrical
Issued 11 April 1989
Resolved
PROVE ELECTRIC SWITCHES AND LIGHT FIXTURES WITHIN HAZARDOUS LOCATIONS EXPLOSION PROOF AS REQUIRED BY 46 CFR 32.45.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Documentation
Issued 11 April 1989
Resolved
OBTAIN NEW CERTIFICATE OF FINANCIAL RESPONSIBILITY.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Documentation
Issued 11 April 1989
Resolved
REWRITE OIL TRANSFER PROCEDURES TO COMPLY WITH 33 CFR 155.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989