A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 May 2024
Resolved
Batteries must be mounted in trays lined with, or constructed of, a material that is resistant to damage by electrolyte. Vessel battery found on the the deck near drivers seat without a tray/battery box. Owner shall place batteries in a appropriate tray/ box meeting the requirements with in 14 days of the inspection date.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 May 2024
Resolution: Vessel rep sent photo of the batteries in a approved box.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2024
Resolved
A vessel not required to have a power driven fire pump must have at least three 9.5 liter (2 1/2 gallon) buckets. The words FIRE BUCKET must be stenciled in a contrasting color on each bucket. Vessel was found with three 4 1/2 gallon buckets. Owner shall replace with the 2 1/2 gallon buckets and stencil FIRE BUCKET on each one.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 May 2024
Resolution: Vessel rep sent photo of the fire buckets which meet the regulation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 May 2024
Resolved
Engine exhaust pipe installation must be suitably insulated or shielded from combustible material. Vessels dry engine exhaust pipping from a gasoline powered engine found without out proper insulation. Owner shall properly insulate the engine exhaust system within 30 days of the inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 December 2024
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 15 May 2024
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Fuel shutoff's on vessel were found painted over and the direction of operation not visible. Owner shall mark fuel shutoffs in accordance with the regulation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 May 2024
Resolution: Vessel rep sent photo of the marking for the shut off.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2024
Resolved
The Vessel is required to process sistering information to Marine Safety Center(MSC) and get a stability letter prior to operating with full COI passenger count. The vessel is restricted to the carriage of 26 passengers and 1 crew member until the stability test process is completed and approved. Complete prior to August 30th 2024.
Action required: 705 - Other - as specified
Due 30 April 2024
Resolved 10 October 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 January 2024
Resolved
Vessel is under going the modifications required by 46CFR175.124. Vessel will not be able to carry passengers in accordance with the COI until the requirements of the regulations are met.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2024
Resolution: Owner [name withheld] modifications and waiting on MSC stabilty letter
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 26 April 2023
Resolved
Fixed Fire Extinguishing system servicing is out of date. Fire Extinguishing systems shall be serviced on an annual basis.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2023
Resolved 10 May 2023
Resolution: Fire extingishers arhave been inspected and are in compliance.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 April 2023
Resolved
Vessel did not have the required amount of fire buckets on board during the inspection. Vessel shall have three Fire buckets on board. Vessel owner is required to have fire buckets on board prior to embarking passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2023
Resolved 10 May 2023
Resolution: Owner has the required amount of fire buckets on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 April 2023
Resolved
Vessel was missing 06 adult PFD's out of the 30 required to be on board. Vessel owner shall keep the required PFD's according to the Certificate of inspection prior to embarking passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2023
Resolved 10 May 2023
Resolution: Owner placed the 6 PFD's on board the vessel that were missing during inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 April 2023
Resolved
Fist aid Kit was expired. Vessel shall keep First aid kits in compliance. Replace within 7 days.
Action required: 705 - Other - as specified
Due 3 May 2023
Resolved 10 May 2023
Resolution: Owner replaced the first aid kit with one that meets the requirements.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 March 2022
Resolved
Vessel does not have shut off valves at the hull penetrations on the port side for the radiator hoses. Install valves in this location with in 30 days.
Action required: 705 - Other - as specified
Due 15 April 2022
Resolved 28 April 2022
Resolution: Vessel Owner installed ball valves at the hull penetration's connection for the hose.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 March 2022
Resolved
Vessel does not have shut off valves at the hull penetrations on the front of the engine compartment for the hoses going to the deferential of the axle. Install valves in this location with in 30 days.
Action required: 705 - Other - as specified
Due 15 April 2022
Resolved 28 April 2022
Resolution: Vessel Owner installed ball valves at the hull penetration's connection for the hose.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 March 2022
Resolved
Properly mark and stow PFD's in the correct vessel. Adult PFD's and Child PFD's shall be stowed and marked in the proper locations.
Action required: 705 - Other - as specified
Due 15 April 2022
Resolved 28 April 2022
Resolution: Vessel Owner properly stowed and Marked PFD's on board the Vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 March 2022
Resolved
Vessel operator is unable to show the fuel is shut off after operating the emergency fuel shut off. Owner shall provide an indicator for the fuel shut off.
Action required: 705 - Other - as specified
Due 15 April 2022
Resolved 28 April 2022
Resolution: Vessel Owner installed a Fuel Shut off that indicates when the fuel is on or off.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 March 2021
Resolved
The COI shall be kept on board the vessel under glass or suitable transparent material, if impracticable, the certificates must be kept on board in a weather tight container readily available for use by the crew and display to passengers and others on request.
The vessel does not maintain a valid COI on board the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 June 2021
Resolution: Installed COI
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 5 March 2021
Resolved
The stability letter shall be kept on board the vessel under glass or suitable transparent material, if impracticable, the stability letter must be kept on board in a weather tight container readily available for use by the crew and display to passengers and others on request.
The vessel does not maintain a valid stability letter on
board the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 June 2021
Resolution: Installed Stability Letter
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2021
Resolved
Each child sized life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets.
Child size life jackets are not stowed separately.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2021
Resolution: New stowage location.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 5 March 2021
Resolved
Inspection and operation of all weathertight closures above the weather deck and the provisions for drainage
of sea water from the exposed decks;
Forward hatch opening gasket needs replacement so that hatch will shut to prevent ingress of weather.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2021
Resolution: Replaced gasket.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 5 March 2021
Resolved
All electrical equipment and circuits must be clearly marked and identified.
The Navigation lights at the operating station are not marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2021
Resolution: Labeled Nav lights at operating station.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 March 2021
Resolved
A vessel must carry a first aid kit approved under 160.041 or an equivalent kit, must be easily visible and readily available to the crew.
The kit on board was expired.
Action required: 10 - Deficiency Rectified
Resolved 5 March 2021
Resolution: Replaced first aid kits
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 March 2021
Resolved
Each life ring on a vessel must be approved under 160.050, be readily accessible, be stowed in a way that it can be rapidly cast loose, and not permanently secured in anyway.
The life ring w/ line was not stowed in a fashion that allowed for it to be rapidly cast loose.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 March 2021
Resolution: Installed new lifebuoy arrangement.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 July 2020
Resolved
Remove/repair dead end wire in engine compartment beside manifold.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 January 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 16 July 2020
Resolved
Permanent plug vent at bottom of gunwale on port side below operators seat.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 January 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 16 July 2020
Resolved
Replace seals around engine compartment hatch, front ventilation hatch and rear door.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 January 2022
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 16 July 2020
Resolved
Clean bilge of all debris and oil.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 July 2020
Resolved
Replace RPM gauge
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 March 2019
Resolved
Outer cover of fuel line found rotting and cracked.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 March 2019
Resolved
Install lagging on exhaust piping crossover in engine compartment due to close proximity of fuel lines.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 May 2019
Electrical › Electric Supply System (service) › Cable
Issued 2 February 2017
Resolved
Found cables not properly mounted near the rotating shaft. Properly mount cables to satisfaction of attending CG Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 March 2017
Resolved 2 March 2017
Resolution: Cables were properly mounted.
Operations/Management › Drills/Instruction › Not Conducted
Issued 24 January 2017
Resolved
Crew training has not been conducted since last summer (AUG 16). Training for emergency procedures shall be conducted once every three months. Conduct training prior to getting underway with passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2017
Resolved 2 February 2017
Resolution: Crew training was completed.
Engineering › Fuel Oil Service System › Hose
Issued 24 January 2017
Resolved
Found fuel hose was "Sierra Silverado 2000." Manufacturer stated hose is rated for recreational use only and designed to be a fuel vent hose. Replace hose with one that meets SAE J-1942 with factory-assembled fittings meeting SAE J-1475.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 2 March 2017
Resolution: Fuel hose was replaced with one that was compliant with J 1942 standards.
Construction/Loadline › Hull › Side Shell
Issued 24 January 2017
Resolved
Found that the starboard rear fender well was missing a weld from installation. Complete weld.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 2 February 2017
Resolution: Fender well was welded.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 24 January 2017
Resolved
Vessel was recently painted and did not have any hull markings. Mark name of the vessel on the port/starboard sides and stern. Mark hailing port on stern. Markings must be at least 4 inches in height.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 2 February 2017
Resolution: Hull markings were painted.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 24 January 2017
Resolved
Management Information System (MIS) Data Reporting has not been completed for 2016. Submit form U.S. Department of Transportation Drug and Alcohol Testing MIS Data Collection to Commandant (CG-INV) by March 15.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 2 March 2017
Resolution: MIS reports were submitted.
Documentation › Certificates/Documents › Stability Letter
Issued 17 February 2012
Resolved
Stability letter denotes 30 passengers allowed, where as COI denotes 31 persons allowed. Until the issue is resolved or a new COI issued, a CG-835 will be issued limiting the number of passengers to 29, making total number of persons allowed 30.
Action required: 705 - Other - as specified
Due 17 April 2012
Resolved 1 March 2012
Resolution: COI now reflects 29 pax and 30 total persons allowed, as per stability letter.
Fire Fighting › Fire Bucket › Stenciling
Issued 3 March 2009
Resolved
Fire buckets not marked
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 11 March 2009
Construction/Loadline › Hull › Weld
Issued 3 March 2009
Resolved
Fore and aft carrier bearing plates with excessive weld material. Grind and re-weld
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2009
Engineering › Bilge Water Management System › Hose
Issued 3 March 2009
Resolved
Port aft bilge pump hose missing hose clamp.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2009
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 3 March 2009
Resolved
Children lifejacket stowed location not appropriately marked as 46 CFR 180.78 (a) (5)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2009
Engineering › Gasoline Engine (propulsion) › Exhaust Outlet (2 stroke)
Issued 3 March 2009
Resolved
Exhaust guards not mounted
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 March 2009
Resolved 11 March 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 March 2009
Resolved
Throughout the vessel, plastic straps were used to attach wires to the vessel's hull.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 March 2009
Resolved 9 April 2009
Construction/Loadline › Markings › Load Line Mark
Issued 3 March 2009
Resolved
Freeboard load line not marked on the hull of the vessel
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 11 March 2009
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 3 March 2009
Resolved
Portside vent closure not working properly. Once released locally it would not reset.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2009
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 3 March 2009
Resolved
Fire wall needs to extend down to the hull in order to create a segregated engine compartment for fire fighting purposes.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 March 2009
Resolved 11 March 2009
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 3 March 2009
Resolved
Segregate fuel tank compartment to ensure efficiency of fixed fire protection system
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 March 2009
Resolved 11 March 2009
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 3 March 2009
Resolved
B II needs to be secured in mounting bracket
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2009
Engineering › Bilge Water Management System › Hose
Issued 3 March 2009
Resolved
The securing of vital system hoses in the engine compartment needs to be of metal construction (not plastic ties).
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 11 March 2009
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 6 February 2008
Resolved
Heat/Vapor sensor was not mounted to the bulkhead in the port-stern bildge compartment. It was wrapped around a piece of pipe and dangling.
Condition: Improper Installation
Due 13 February 2008
Resolved 14 February 2008
Resolution: Vapor sensor is mounted properly.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 6 February 2008
Resolved
Heat/Vapor sensor in Port-stern bilge compartment was inoperable. Item was replaced with new sensor on the spot.
Due 13 February 2008
Resolved 6 February 2008
Resolution: Item was replaced during the course of the inspection with an operable sensor.
Electrical › Electric Supply System (service) › Battery Installation
Issued 6 February 2008
Resolved
Battery box was not mounted to the vessel. It was free to slide along the deck.
Condition: Improper Installation
Due 13 February 2008
Resolved 14 February 2008
Resolution: Battery box mounted correctly.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 February 2008
Resolved
The vessel's life-ring was labeled "[name withheld]" which was the previous name of the vessel. The crew was directed to mark the life-ring with the current name of the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2008
Resolution: Life ring labeled "[name withheld]".
Fire Fighting › Remote Fuel Shutoff › General
Issued 6 February 2008
Resolved
The fuel shut-off valve is not labeled in accordance with the regulations. It needs to be marked with the purpose and direction of operation.
Condition: Improper Installation
Due 13 February 2008
Resolved 14 February 2008
Resolution: Fuel shut-off labeled with directions.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 6 February 2008
Resolved
Lifejackets are labeled with "[name withheld]" which is the previous name of the vessel. Crew was instructed to label each lifejacket with the current name of the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2008
Resolution: Lifejackets labeled "[name withheld]".
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 6 February 2008
Resolved
The last seat on the port-side deck prior to the upper seating deck is missing a couple bolts and moving freely.
Condition: Improper/Lack of Maintenance
Due 13 February 2008
Resolved 14 February 2008
Resolution: Bolts have been replaced and seat is mounted firmly.
Engineering › Steering Gear System › Rudder Stock
Issued 6 February 2008
Resolved
Rudder packing needs to be tightened or replaced due to excessive leaking.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2008
Resolution: Rudder packing has been replaced.
Stability › Watertight Integrity › General
Issued 6 February 2008
Resolved
There is a flange covering the hole where the old drive shaft used to pertrude through the hull in the forward location. The flange is leaking and needs to be tightened or replaced to stop the leak.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2008
Resolution: Flange has been re-siliconed and mounted to maintain watertight integrity.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 6 February 2008
Resolved
There was a child's lifejacket which was very faded and wasted looking. One tug on the strap and it ripped off of the lifejacket. The lifejacket was destroyed in Coast Guard presence.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2008
Resolution: The lifejacket was destroyed and replaced with one that was in good condition.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 6 February 2008
Resolved
The portable fire extinguishers had been serviced and not place back on the vessel. Extinguishers were placed on the vessel prior to the inspectors departure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2008
Resolution: Extinguishers were placed back on the vessel.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 6 February 2008
Resolved
A cotter pin holding the rear drive shaft support was broken. It was the aft inside port pin. The pin was replaced prior to Coast Guard inspectors departure.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2008
Resolution: The cotter pin was replaced with a new one.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 6 March 2007
Resolved
Add washers to the hinge plate pin as to prevent wearing on retaning pins from connection brackets.
Action required: 705 - Other - as specified
Due 1 April 2007
Resolved 6 August 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 6 March 2007
Resolved
Install battery retaining system.
Action required: 705 - Other - as specified
Due 1 April 2007
Resolved 6 August 2007
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 6 March 2007
Resolved
Install break air bottle so as not to move during normal operations.
Action required: 705 - Other - as specified
Due 1 April 2007
Resolved 6 August 2007
Electrical › Electric Supply System (service) › Cable
Issued 6 March 2007
Resolved
Remove all cables not in service. All cable connections and cables are to be installed as per 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 1 May 2007
Resolved 6 August 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 March 2007
Resolved
Provide approved first aid kit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2007
Stability › Watertight Integrity › Coaming
Issued 13 October 2006
Resolved
Vessel is required to extend the watertight coaming around the aft deck area. The coaming is to be watertight to a height of 12" above the after deck.
Action required: 705 - Other - as specified
Due 1 May 2007
Resolved 6 August 2007
Lifesaving › Lifebuoys › Serviceable
Issued 8 March 2006
Resolved
Clean and add retro-reflective tape on ring buoy.
Action required: 705 - Other - as specified
Due 30 March 2006
Resolved 8 March 2006
Lifesaving › Lifejacket/PFD (Type II) › Quantity
Issued 8 March 2006
Resolved
Need to add additional adult life jacket to operate W/33 persons onboard. Limited to 32 adults in total.
Action required: 705 - Other - as specified
Resolved 8 March 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 8 March 2005
Resolved
Provide proof of annual service on all vsl portable fire extinguishers IAW 46 CFR 176.810(b)(1). Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2005
Resolution: The annual service on the portable fire extinguishers was completed on 10 Mar 2005.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 March 2005
Resolved
Provide proof of annual service on vsl's fixed fire extinguisher IAW 46 CFR 176.810(b)(1). Prior to 01 Apr 2005.
Action required: 705 - Other - as specified
Due 1 April 2005
Resolved 5 May 2005
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 March 2005
Resolved
Make repairs and/or alterations to firewall so that it is MORE vapor tight. NVIC 01-01 enclosure 1 page 27. Prior to 08 APR 2005.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 10 March 2005
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 March 2005
Resolved
Install propeller shaft and make the Higgins pump operational. NVIC 01-01. Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2005
Documentation › Markings/Placards › Garbage Placard
Issued 8 March 2005
Resolved
Post MARPOL Placard. IAW 33 CFR 151.59 (a)(I). Prior to 08 Apr 2005.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 5 May 2005
Documentation › Markings/Placards › Oil Discharge Placard
Issued 8 March 2005
Resolved
Post oil pollution placard at each bilge control station. IAW 33 CFR 155.450. Prior to 08 Apr 2004.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 5 May 2005
Documentation › Manuals/Policy Documentation
Issued 23 March 2004
Resolved
Provide Operations Manual for review. LEGACY COMPONENT DESC: Operations Manual
Due 23 April 2004
Resolved 24 March 2004
Resolution: Operations Manual provided for review.
Documentation › Manuals/Policy Documentation
Issued 23 March 2004
Resolved
Provide Emergency Repose Manual for review. LEGACY COMPONENT DESC: Emergency Repose Manual
Due 23 April 2004
Resolved 24 March 2004
Resolution: Emergency Repose Manual provided for review.
Documentation › Logs/Records
Issued 23 March 2004
Resolved
Provide vessel's name on passenger count log. LEGACY COMPONENT DESC: Logbook (official)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2004
Resolution: Vessel''s name provided on passenger count log.
Construction/Loadline › Structures
Issued 23 March 2004
Resolved
Repair the vapor barrier in the engine space. LEGACY COMPONENT DESC: Machinery Space Opening
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2004
Resolved 29 April 2004
Resolution: Vapor barrier in the engine space repaired.
Construction/Loadline › Structures
Issued 23 March 2004
Resolved
Make the fuel tank space vapor tight. LEGACY COMPONENT DESC: Machinery Space Opening
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 29 April 2004
Resolution: Fuel tank space made vapor tight.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 23 March 2004
Resolved
Provide evidence of 50% First Aid and CPR card. LEGACY COMPONENT DESC: First Aid
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 June 2004
Resolved 1 June 2004
Personnel › Certificates/Documents/Licenses
Issued 23 March 2004
Resolved
Provide for review copies of the masters' licenses. LEGACY COMPONENT DESC: License, Master
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 23 March 2004
Resolution: Copies of Masters'''''''' license''''''''s provided for review.
Accommodation/Occupational Safety › Medical/First Aid
Issued 23 March 2004
Resolved
Provide on board an USCG approved first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 29 April 2004
Resolution: Approved first aid kit provided on board.
Documentation › Markings/Placards
Issued 23 March 2004
Resolved
Post the emergency procedures. LEGACY COMPONENT DESC: emergency procedures
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2004
Resolved 29 April 2004
Resolution: Emergency procedures posted.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 23 March 2004
Resolved
Provide an operational pre-engineered fire suppression system in the engine space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2004
Resolved 29 April 2004
Resolution: Operational pre-engineered fire suppression system provided in the engine space.
Engineering › Bilge Water Management System
Issued 23 March 2004
Resolved
Prove the proper operation of the aft bilge pump. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2004
Resolved 29 April 2004
Resolution: Proper operation of the aft bilge pump proven.
Construction/Loadline › Structures
Issued 23 March 2004
Resolved
Remove unused rear axle vent hoses and cap off. LEGACY COMPONENT DESC: Ventilators
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 29 April 2004
Resolution: Unused rear axle vent hoses removed and capped off.
Construction/Loadline › Hull
Issued 23 March 2004
Resolved
Replace the cotter pins in way of the aft hinge plate assembly and provide lock washers where missing. LEGACY COMPONENT DESC: Deck plating
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2004
Resolved 29 April 2004
Resolution: Cotter pins in way of the aft hinge plate assembly replaced, and lock washers provided.
Engineering › Bilge Water Management System
Issued 23 March 2004
Resolved
Remove excess oily water residue in the bilges for internal inspection. LEGACY COMPONENT DESC: Bilge
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 29 April 2004
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 23 March 2004
Resolved
Secure second seat aft of bow on the starboard seat. LEGACY COMPONENT DESC: Seat
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 29 April 2004
Resolution: Second seat aft of bow on the starboard seat secured.
Fire Fighting › Ventilation Systems
Issued 23 March 2004
Resolved
Prove proper operation of engine space port dampner. LEGACY COMPONENT DESC: engine space dampner
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2004
Resolved 23 March 2004
Resolution: Proved proper operation of engine space port dampner.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 18 March 2003
Resolved
Maintain fixed fire extinguishers semi annualy IAW manufacturers instructions.
Condition: Improper/Lack of Maintenance
Due 19 April 2003
Resolved 6 May 2003
Resolution: All extinguishers inspected and tagged.
Lifesaving › Lifejacket/PFD (Type I)
Issued 18 March 2003
Resolved
Replace PFD that deteoriated.
Condition: Improper/Lack of Maintenance
Due 19 April 2003
Resolved 6 May 2003
Resolution: Worn PFDs replaced.
Fire Fighting › Miscellaneous Items
Issued 18 March 2003
Resolved
Mount aft vapor sensor.
Condition: Improper/Lack of Maintenance
Due 19 April 2003
Resolved 6 May 2003
Resolution: Vapor sensor properly mounted.
Operations/Management › Drills/Instruction
Issued 20 February 2002
Resolved
Provide and post Emergency Instructions in accordance with 46 CFR 185.510. LEGACY COMPONENT DESC: Safety Orientation
Condition: Improper/Lack of Maintenance
Due 20 March 2002
Resolved 19 March 2002
Resolution: Posted instructions reviewed.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 20 February 2002
Resolved
Remove safety pin for the engine compartment and the fuel tank compartment fixed fire extinguisher cylinder heads. LEGACY COMPONENT DESC: Control Valve
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2002
Resolution: Both safety pins have been removed.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 20 February 2002
Resolved
Install a vapor barrier between the engine compartment and area under the passenger seating. The volume in the engine compartment is not to exceed 125 cubic feet. LEGACY COMPONENT DESC: Quantity of Gas
Condition: Improper Installation
Due 20 March 2002
Resolved 19 March 2002
Resolution: A vapor barrier has been fitted.
Electrical › Electric Supply System (service)
Issued 20 February 2002
Resolved
Provide and install a battery box that is corrosion resistant. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper Installation
Due 20 March 2002
Resolved 19 March 2002
Resolution: A battery box has been installed.
Construction/Loadline › Markings
Issued 20 February 2002
Resolved
Provide a permanent mark and a painted mark indicating the 15.5 minimum freeboard at the vehicle's stern. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Condition: Unknown
Due 20 March 2002
Resolved 19 March 2002
Resolution: A permanent and painted mark has been provided.
Engineering › Fuel Oil Service System
Issued 20 February 2002
Resolved
Replace fuel hose with SAE J-1492 hose. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Due 10 April 2002
Resolved 10 April 2002
Resolution: MSO Memphis received a fax letter dated 4/15/2002 signed by the owner/operator stating that the fuel line was changed on 4/10/2002.
Documentation
Issued 24 April 2001
Resolved
Provide for USCG review, a company operations manual as per NVIC 1-01.
Condition: Unknown
Due 31 August 2001
Resolved 20 February 2002
Resolution: Reviewed manual.
Construction/Loadline
Issued 24 April 2001
Resolved
Submit a written proposal for valves/piping for keel cooler.
Condition: Unknown
Due 24 April 2001
Resolved 24 April 2001
Construction/Loadline
Issued 26 March 2001
Resolved
Provide and install gasket to forward hatch cover.
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Construction/Loadline
Issued 26 March 2001
Resolved
Prior to carrying passengers, ensure all hinge plate assemblies have a minimum of 2 cap screws installed. Properly install all 3 cap screws priorto 26 APR 01.
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Construction/Loadline
Issued 26 March 2001
Resolved
Install a mechanism that will permit the operator to secure the engine compartment hatch cover.
Condition: Unknown
Due 31 December 2001
Resolved 20 February 2002
Resolution: Installed and tested.
Engineering
Issued 26 March 2001
Resolved
Provide aft fuel compt fuel shutoff valve.
Condition: Unknown
Due 31 August 2001
Resolved 20 February 2002
Resolution: Valve installed.
Construction/Loadline
Issued 26 March 2001
Resolved
Plug hole on fwd bow adjacent to headlights.
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Electrical
Issued 26 March 2001
Resolved
Provide and install mechanical crimps for starboard side aft bilge pump andbilge alarm sensor wires.
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Construction/Loadline
Issued 26 March 2001
Resolved
Replace missing side cap screw on forward hinge assembly.
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Fire Fighting
Issued 26 March 2001
Resolved
Submit written proposal for installation of pre-engineered fire fighting system.
Condition: Unknown
Due 31 December 2001
Resolved 20 February 2002
Resolution: See fire FE-241 Model FE 125A fixed fire extinguishing system. USCG approval No. 162.029/238/0.
Lifesaving
Issued 26 March 2001
Resolved
In accordance with 46 CFR 185.516(a) post the lifejacket instructions in a conspicuous location.
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Fire Fighting
Issued 26 March 2001
Resolved
Provide and post operating instructions for the installed fixed fire extinguishing system.
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Construction/Loadline
Issued 26 March 2001
Resolved
Provide a permanent (welded bead or punched mark) and painted mark indicating minimum freeboard at vessel's stern.
Condition: Unknown
Due 31 December 2001
Resolved 20 February 2002
Resolution: Not resolved. Re-issued with activity 1493830.
Fire Fighting
Issued 6 April 2000
Resolved
Replace CO2 discharge line to engineroom.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Fire Fighting
Issued 9 March 1999
Resolved
INSTALL FLAMMABLE VAPOR DETECTION SYSTEM IAW 46 CFR 182.480.
Condition: Unknown
Due 9 March 1999
Resolved 9 March 1999
Lifesaving
Issued 4 March 1998
Resolved
Provide 33 adult Type I life preservers and 4 child Type I life preservers.Vessel shall not carry any passengers for hire until this requirment is corrected.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Navigation
Issued 4 March 1998
Resolved
Prove proper operation of vessel's navigation lights.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Lifesaving
Issued 4 March 1998
Resolved
Provide a first aid kit.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Fire Fighting
Issued 4 March 1998
Resolved
Provide one B-I and one B-II portable fire extinguishers.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998