MAURY USCG vessel records
← All vessels

MISS KENNEDY

Built
1944
Last inspected
27 April 2026
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

441966
Flag
UNITED STATES
Maury page id
psix-441966

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Net Ton
6 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 15 inspections, each with its date, unit and type; 34 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 15

27 April 2026 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8361636
17 April 2025 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8114011
15 May 2024 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7917808
10 January 2024 Administrative Inspection
Administrative · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7848786
26 April 2023 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7677336
24 March 2022 Drydock Exam · COI Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7422318
5 March 2021 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7150979
16 July 2020 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7002861
26 March 2019 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6660458
24 October 2018 Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6580057
2 August 2018 Administrative Inspection
Administrative · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6498858
25 July 2018 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6507184
31 January 2018 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6348418
24 January 2017 Internal Structural Exam · Drydock Exam · Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6076928
27 April 2016 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 5865016

Deficiency record · 34

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 May 2024 Resolved
Batteries must be mounted in trays lined with, or constructed of, a material that is resistant to damage by electrolyte. Vessel battery found on the the deck near drivers seat without a tray/battery box. Owner shall place batteries in a appropriate tray/ box meeting the requirements with in 14 days of the inspection date.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 May 2024
Resolution: Vessel rep sent photo of the batteries in a approved box.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2024 Resolved
A vessel not required to have a power driven fire pump must have at least three 9.5 liter (2 1/2 gallon) buckets. The words FIRE BUCKET must be stenciled in a contrasting color on each bucket. Vessel was found with three 4 1/2 gallon buckets. Owner shall replace with the 2 1/2 gallon buckets and stencil FIRE BUCKET on each one.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 May 2024
Resolution: Vessel rep sent photo of the fire buckets which meet the regulation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 May 2024 Resolved
Engine exhaust pipe installation must be suitably insulated or shielded from combustible material. Vessels dry engine exhaust pipping from a gasoline powered engine found without out proper insulation. Owner shall properly insulate the engine exhaust system within 30 days of the inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 December 2024
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 15 May 2024 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Fuel shutoff's on vessel were found painted over and the direction of operation not visible. Owner shall mark fuel shutoffs in accordance with the regulation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 May 2024
Resolution: Vessel rep sent photo of the marking for the shut off.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2024 Resolved
The Vessel is required to process sistering information to Marine Safety Center(MSC) and get a stability letter prior to operating with full COI passenger count. The vessel is restricted to the carriage of 26 passengers and 1 crew member until the stability test process is completed and approved. Complete prior to August 30th 2024.
Action required: 705 - Other - as specified
Due 30 April 2024
Resolved 10 October 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 January 2024 Resolved
Vessel is under going the modifications required by 46CFR175.124. Vessel will not be able to carry passengers in accordance with the COI until the requirements of the regulations are met.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2024
Resolution: Owner [name withheld] modifications and waiting on MSC stabilty letter
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 26 April 2023 Resolved
Fixed Fire Extinguishing system servicing is out of date. Fire Extinguishing systems shall be serviced on an annual basis.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2023
Resolved 10 May 2023
Resolution: Fire extingishers arhave been inspected and are in compliance.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 April 2023 Resolved
Vessel did not have the required amount of fire buckets on board during the inspection. Vessel shall have three Fire buckets on board. Vessel owner is required to have fire buckets on board prior to embarking passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2023
Resolved 10 May 2023
Resolution: Owner has the required amount of fire buckets on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 April 2023 Resolved
Vessel was missing 06 adult PFD's out of the 30 required to be on board. Vessel owner shall keep the required PFD's according to the Certificate of inspection prior to embarking passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2023
Resolved 10 May 2023
Resolution: Owner placed the 6 PFD's on board the vessel that were missing during inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 April 2023 Resolved
Fist aid Kit was expired. Vessel shall keep First aid kits in compliance. Replace within 7 days.
Action required: 705 - Other - as specified
Due 3 May 2023
Resolved 10 May 2023
Resolution: Owner replaced the first aid kit with one that meets the requirements.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 March 2022 Resolved
Vessel does not have shut off valves at the hull penetrations on the port side for the radiator hoses. Install valves in this location with in 30 days.
Action required: 705 - Other - as specified
Due 15 April 2022
Resolved 28 April 2022
Resolution: Vessel Owner installed ball valves at the hull penetration's connection for the hose.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 March 2022 Resolved
Vessel does not have shut off valves at the hull penetrations on the front of the engine compartment for the hoses going to the deferential of the axle. Install valves in this location with in 30 days.
Action required: 705 - Other - as specified
Due 15 April 2022
Resolved 28 April 2022
Resolution: Vessel Owner installed ball valves at the hull penetration's connection for the hose.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 March 2022 Resolved
Properly mark and stow PFD's in the correct vessel. Adult PFD's and Child PFD's shall be stowed and marked in the proper locations.
Action required: 705 - Other - as specified
Due 15 April 2022
Resolved 28 April 2022
Resolution: Vessel Owner properly stowed and Marked PFD's on board the Vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 March 2022 Resolved
Vessel operator is unable to show the fuel is shut off after operating the emergency fuel shut off. Owner shall provide an indicator for the fuel shut off.
Action required: 705 - Other - as specified
Due 15 April 2022
Resolved 28 April 2022
Resolution: Vessel Owner installed a Fuel Shut off that indicates when the fuel is on or off.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 March 2021 Resolved
The COI shall be kept on board the vessel under glass or suitable transparent material, if impracticable, the certificates must be kept on board in a weather tight container readily available for use by the crew and display to passengers and others on request. The vessel does not maintain a valid COI on board the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 June 2021
Resolution: Installed COI
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 5 March 2021 Resolved
The stability letter shall be kept on board the vessel under glass or suitable transparent material, if impracticable, the stability letter must be kept on board in a weather tight container readily available for use by the crew and display to passengers and others on request. The vessel does not maintain a valid stability letter on board the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 June 2021
Resolution: Installed Stability Letter
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2021 Resolved
Each child sized life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child size life jackets are not stowed separately.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2021
Resolution: New stowage location.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 5 March 2021 Resolved
Inspection and operation of all weathertight closures above the weather deck and the provisions for drainage of sea water from the exposed decks; Forward hatch opening gasket needs replacement so that hatch will shut to prevent ingress of weather.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2021
Resolution: Replaced gasket.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 5 March 2021 Resolved
All electrical equipment and circuits must be clearly marked and identified. The Navigation lights at the operating station are not marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2021
Resolution: Labeled Nav lights at operating station.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 March 2021 Resolved
A vessel must carry a first aid kit approved under 160.041 or an equivalent kit, must be easily visible and readily available to the crew. The kit on board was expired.
Action required: 10 - Deficiency Rectified
Resolved 5 March 2021
Resolution: Replaced first aid kits
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 March 2021 Resolved
Each life ring on a vessel must be approved under 160.050, be readily accessible, be stowed in a way that it can be rapidly cast loose, and not permanently secured in anyway. The life ring w/ line was not stowed in a fashion that allowed for it to be rapidly cast loose.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 March 2021
Resolution: Installed new lifebuoy arrangement.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 July 2020 Resolved
Remove/repair dead end wire in engine compartment beside manifold.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 January 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 16 July 2020 Resolved
Permanent plug vent at bottom of gunwale on port side below operators seat.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 January 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 16 July 2020 Resolved
Replace seals around engine compartment hatch, front ventilation hatch and rear door.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 January 2022
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 16 July 2020 Resolved
Clean bilge of all debris and oil.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 July 2020 Resolved
Replace RPM gauge
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 March 2019 Resolved
Outer cover of fuel line found rotting and cracked.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 March 2019 Resolved
Install lagging on exhaust piping crossover in engine compartment due to close proximity of fuel lines.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 May 2019
Electrical › Electric Supply System (service) › Cable
Issued 2 February 2017 Resolved
Found cables not properly mounted near the rotating shaft. Properly mount cables to satisfaction of attending CG Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 March 2017
Resolved 2 March 2017
Resolution: Cables were properly mounted.
Operations/Management › Drills/Instruction › Not Conducted
Issued 24 January 2017 Resolved
Crew training has not been conducted since last summer (AUG 16). Training for emergency procedures shall be conducted once every three months. Conduct training prior to getting underway with passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2017
Resolved 2 February 2017
Resolution: Crew training was completed.
Engineering › Fuel Oil Service System › Hose
Issued 24 January 2017 Resolved
Found fuel hose was "Sierra Silverado 2000." Manufacturer stated hose is rated for recreational use only and designed to be a fuel vent hose. Replace hose with one that meets SAE J-1942 with factory-assembled fittings meeting SAE J-1475.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 2 March 2017
Resolution: Fuel hose was replaced with one that was compliant with J 1942 standards.
Construction/Loadline › Hull › Side Shell
Issued 24 January 2017 Resolved
Found that the starboard rear fender well was missing a weld from installation. Complete weld.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 2 February 2017
Resolution: Fender well was welded.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 24 January 2017 Resolved
Vessel was recently painted and did not have any hull markings. Mark name of the vessel on the port/starboard sides and stern. Mark hailing port on stern. Markings must be at least 4 inches in height.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 2 February 2017
Resolution: Hull markings were painted.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 24 January 2017 Resolved
Management Information System (MIS) Data Reporting has not been completed for 2016. Submit form U.S. Department of Transportation Drug and Alcohol Testing MIS Data Collection to Commandant (CG-INV) by March 15.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 2 March 2017
Resolution: MIS reports were submitted.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.