Records from 2012 to 2026. Most recent: inspection, 9 April 2026.
Inspection history · 15
9 April 2026
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8320929
11 March 2025
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8081577
1 May 2024
Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7899566
18 April 2023
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7654619
28 April 2022
COI Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7417399
8 March 2022
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7403051
22 April 2021
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7170700
10 May 2020
COI Inspection · DAPI Audit
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6943281
3 July 2019
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6734701
2 March 2018
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6364857
12 June 2017
Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6166450
10 April 2017
Examination of Repairs · Administrative Inspection · Hull Examination · Internal Structural Exam · Annual Inspection · Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6121274
10 January 2017
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6068810
7 July 2016
Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5952825
18 April 2016
Deficiency Check · Plan Review "T" Boat · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5856676
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 9 April 2026
Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight:A hatch on a vessel that operates only on protected waters. A hatch cover must have securing devices. The stbd #3 void cover was missing bolts.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2026
Resolved 15 April 2026
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 April 2026
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. The placard was worn.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2026
Resolved 15 April 2026
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 April 2026
Resolved
Conduct and log crew training and drills to include fire drill, man overboard drill and abandon ship drill in accordance with 46CFR 185.512, 185.520 and 185.524. The last record of drills was 7/04/2024
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 9 April 2026
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 March 2025
Resolved
Required first aid kit item IAW ISO 18813:2006(E) paragraph 4.12 as referenced by 46 CFR 184.710 (via 46 CFR 199.175(b)(10)) was expired; specifically analgesic medication.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 April 2025
Resolution: First aid kit updated; including a compliant complement of analgesic medicines.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 May 2024
Resolved
46 CFR 180.70
A vessel must carry one floating water light, unless it is limited to daytime operation.
Battery for floating water light expired. Vessel is restricted to daytime operations until rectified.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2024
Resolved 10 May 2024
Resolution: Operator replaced battery.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 1 May 2024
Resolved
46 CFR 179.360
A hatch cover must be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss.
Found STBD AFT hatch lanyard was not connected to hatch frame.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2024
Resolved 10 May 2024
Resolution: Opeartor reattached lanyard to hatch frame.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 April 2022
Resolved
Bilge high level alarms are not operational in all voids. Prove proper operation of all bilge high level alarms.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 29 April 2022
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 April 2022
Resolved
Contents of the first aid kit are expired. Prove a first aid kit is onboard meeting 46 CFR 184.710.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 12 May 2022
Resolution: The deficiency was cleared to the satisfaction of a CG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 April 2022
Resolved
The life jacket donning instruction placard is not legible. Prove a legible donning placard is posted onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 12 May 2022
Resolution: The deficiency was cleared to the satisfaction of a CG Marine Inspector.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 22 April 2021
Resolved
Conduct and log crew training and drills to include fire drill, man overboard drill and abandon ship drill in accordance with 46CFR185.512, 185.520 and 185.524.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 22 April 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 April 2021
Resolved
Port bilge pump leaks at the pump housing. Pump must be maintained in a leak free condition. Repair pump to the satisfaction of the Coast Guard.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 15 June 2021
Resolution: Provided proof of bilge leak repair, bad gasket.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 July 2019
Resolved
Prove receipt of hand bilge pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2019
Resolved 30 July 2019
Resolution: Received photo via email proving receipt of required hand bilge pump.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 15 July 2019
Resolved
Provide means to document man overboard training.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 30 July 2019
Resolution: Received via email user generated form to document training.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 15 July 2019
Resolved
Provide means to document fire fighting training.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 30 July 2019
Resolution: Received via email user generated form to document training.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 15 July 2019
Resolved
Provide means to document crew member training.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 30 July 2019
Resolution: Received via email user generated form to document training.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 July 2019
Resolved
Prove pre-employment drug testing of deck hand.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 30 July 2019
Resolution: Received email confirmation of enrollment and pre-employment testing.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 22 March 2018
Resolved
Update and submit current electrical plans to OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2018
Resolved 10 April 2018
Resolution: Owner submitted electrical plans to MSC for review and evaluation.
Engineering › Bilge Water Management System › Pump
Issued 22 March 2018
Resolved
Prove proper operation of port bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2018
Resolved 3 April 2018
Resolution: Bilge pump operational with adequate suction.
Fire Fighting › Remote Fuel Shutoff › General
Issued 22 March 2018
Resolved
Make valve handles available for remote fuel shutoff.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2018
Resolved 3 April 2018
Resolution: New valves have been installed and handled availabel for operator to shut off supply.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 22 March 2018
Resolved
Three (3) red flare distress signals and three (3) orange smoke distress signals are expired. Provide current distress signals.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2018
Resolved 3 April 2018
Resolution: Six (6) valid red flares are onboard vessel.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 January 2017
Resolved
Submit and obtain plan approval for the vessel's current electrical arrangement.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 April 2017
Resolved 25 May 2017
Resolution: Electrical plans recieved.
Construction/Loadline › Hull › Hull Plating
Issued 24 January 2017
Resolved
Submit a repair proposal, including any design modifications, for the fractured portion of the port pontoon in way of the No.1 compartment to the cognizant OCMI and effect repairs upon approval.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 April 2017
Resolved 22 May 2017
Resolution: Repairs completed.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 14 June 2016
Resolved
Provide proof the the vsl's current electrical arrangement can meet the requirement outlined in 46 CFR 183.310. Current battery arrangement does not provide adequate reserve capacity to power the loads outlined in 46 CFR 183.310(a)(1) for a minimum of 3 hrs.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 17 June 2016
Resolution: Received email containing pictures of new battery installation that was calculated as satisfying requirement.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 14 June 2016
Resolved
Provide proof that electrical loads under normal operating conditions do not exceed the electrical generation of the vsl's installed alternators. Current calculated normal operating load exceed that of the vsl's alternators installed in the outboards.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 17 June 2016
Resolution: Received email confirmation of measured ampacities of normal operating loads. Loads are sufficiently below vessels charging capacity to ensure sufficient power availability.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 6 June 2016
Resolved
Properly mark all lifejackets with the vessel name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Lifejackets are marked with vsl name.
Documentation › Markings/Placards › Lifejacket Placard
Issued 6 June 2016
Resolved
Provide lifejacket donning placards for all Type I PFDs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Lifejacket donning placards posted.
Stability › Incline Test › General
Issued 18 April 2016
Resolved
Submit to MSC for review the weight changes for stability resulting from the electrical modifications made to the vessel since the last Stability Test.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 14 July 2016
Resolution: O/O submitted request for stability evaluation for weight changes via e-mail.