Records from 2000 to 2025. Most recent: inspection, 29 May 2025.
Inspection history · 93
29 May 2025
Re-Inspection · COI Inspection · ISPS Exam · ACP COI Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8147273
21 November 2024
Annual Inspection · Administrative Inspection · ACP Annual Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8038063
29 August 2024
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7992432
29 August 2024
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7995061
29 August 2024
Administrative Inspection · ACP Drydock Oversight
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8037279
28 August 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7991009
18 April 2024
Administrative Inspection
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7898142
14 September 2023
ACP Annual Oversight · Periodic Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7792200
22 August 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7774518
4 April 2023
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7666131
28 September 2022
ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7568533
18 August 2022
In-Service Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7540571
16 March 2022
ACP Drydock Oversight
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7412873
7 August 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7279747
6 August 2021
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7284175
14 July 2021
ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7257181
12 April 2021
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7178491
18 December 2020
Administrative Inspection
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7113712
11 June 2020
MTSA/ISPS Verification · Re-Inspection · Administrative Inspection · ACP COI Oversight
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6973866
8 May 2020
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6950517
24 July 2019
Administrative Inspection · ACP Drydock Oversight · ACP Periodic Oversight · Re-Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6762028
17 July 2019
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6753266
27 June 2019
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6733593
20 May 2019
Annual Inspection · ACP Annual Oversight · MTSA/ISPS Verification · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6691283
4 December 2018
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6592011
20 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6517987
19 July 2018
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6484395
5 July 2018
Administrative Inspection · ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6467179
30 May 2018
Internal Structural Exam · ACP Drydock Oversight · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6429596
9 March 2018
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6369224
12 January 2018
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6349690
2 January 2018
Deficiency Check · Permit to Proceed
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6333224
14 December 2017
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6334278
5 June 2017
ACP Annual Oversight · Annual Inspection · MTSA/ISPS Verification · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6168699
15 June 2016
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 5917374
13 June 2016
DAPI Audit · MTSA/ISPS Verification · Administrative Inspection · ACP Annual Oversight
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 5907247
17 July 2015
Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 5190418
4 August 2014
ACP Annual Oversight · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4943839
13 February 2012
Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4243586
27 January 2012
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4233126
27 January 2012
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4233522
8 September 2011
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4151862
16 August 2011
MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4120437
14 December 2010
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3910663
29 March 2010
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3706989
16 July 2009
ACP Annual Oversight
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3537223
9 September 2008
ACP Annual Oversight
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3321285
19 June 2008
MTSA Verification
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3248017
28 May 2008
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3220518
24 May 2008
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3219307
7 March 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3177162
27 November 2007
MTSA Verification
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3105995
24 October 2007
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3105852
7 May 2007
Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2925059
26 April 2007
ACP Annual Oversight
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2913540
27 January 2007
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2862966
22 January 2007
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2859859
20 July 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2719271
23 June 2006
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2570490
23 June 2006
MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2685079
21 April 2006
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2657481
28 June 2005
MTSA/ISPS Verification · MARPOL Annex I Examination · ACP COI Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2406067
17 May 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2360570
6 January 2005
ACP Annual Oversight
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2271755
26 August 2004
Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2177696
2 June 2004
MTSA/ISPS Verification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2086126
8 March 2004
ACP COI Oversight · Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2023190
27 December 2003
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2025621
5 November 2003
Annual Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1945185
3 September 2003
In-Service Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1895402
4 August 2003
Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1881290
10 February 2003
Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1742341
18 January 2003
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1732260
11 January 2003
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1728939
5 January 2003
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1727032
18 December 2002
Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1720774
20 November 2002
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1722378
2 August 2002
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1655958
28 April 2002
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1612009
4 April 2002
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1602090
15 October 2001
ACP COI Oversight
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1408852
7 August 2001
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 180431
21 July 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 72028
11 May 2001
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 290002
3 May 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 225441
1 March 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1060654
9 January 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1382117
7 January 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 165277
24 October 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1055006
10 October 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1054659
21 August 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 170913
15 June 2000
Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1403175
18 May 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1056249
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 August 2024
Resolved
74 SOLAS (04)II-1/26.1
Machinery shall be adequate for the service of which they are intended. Port propulsion shaft controllable pitch propeller pump failed.
CODE 705: Enact repairs to the satisfaction of ABS.
Action required: 705 - Other - as specified
Due 29 August 2024
Resolved 30 August 2024
Resolution: Received finding number from ABS.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 August 2021
Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its lifesaving appliances, fire-fighting or other equipment, or whenever any important repairs or renewals are made. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made, that the material and workmanship of such repairs or renwals are in all respects satisfactory, and that the vessel complies in all respects with the regulations in this subchapter.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2021
Resolved 24 August 2021
Resolution: Vessel has provided satisfactory ABS documentation of vessel condition. Vessel will continue inspections under ACP.
10 - Safety of Navigation › N/A - No Subsystem › Long-range identification and tracking system (LRIT)
Issued 20 August 2018
Resolved
Vessel has failed to report via LRIT per 33 CFR 169.230
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 December 2018
Resolution: Vessel provided documentation to USCG regarding LRIT Report.
Engineering › Shafting/Propeller Arrangements › Stern Tube Bearing
Issued 2 January 2018
Resolved
Port Azimuth Thruster Propeller Shaft Seal.
Currently propeller shaft seal is NOT leaking in static state, only while in operation. The OEM Tech has called on the vessel and confirms that the leak is very minimal, estimated at approximately 1 ounce or less per hour of actual operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 9 March 2018
Resolution: OEM technicians attended the Delta Mariner in Port Fourchon La, the seal was replaced in accordance to OEM specifications with a satisfactory result.
Accommodation/Occupational Safety › Messroom › Location
Issued 13 June 2016
Resolved
Galley was found in an unsanitary condition.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 15 June 2016
Resolution: Cleaned galley to the satisfaction of the attending marine inspector
Electrical › Electrical Distribution System (emergency) › Circuit Breaker
Issued 16 August 2011
Resolved
Panel EP-205 had excessively loose circuit breakers supported in place with a cardboard shim. Issued CG-835 to repair/replace necessary components to ensure a tight connection. Deficiency to be corrected to the satisfaction of class or an attending CG Marine Inspector prior to the due date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2011
Resolved 8 September 2011
Resolution: Replaced (3) loose circuit breakers and installed new brackets for the deadfront. All SAT.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 28 May 2008
Resolved
Port MDE thruster inoperable for the second time in 2 months. Make permanent repairs to the satisfaction of attending CG Marine Inspector. No cargo ops until satisfactory repairs and testing completed.
Condition: Damaged By Earlier Event
Due 4 June 2008
Resolved 11 June 2008
Resolution: Disassembly of the Oil distribution box took place (no damages were found), we elected to reinstall the manufactures supplied Oil Distribution box and remove all the temporary hoses and reinstall the proper / original piping. Tested Satisfactory. RSM
Navigation › Piloting/Steering › Magnetic Compass
Issued 26 April 2007
Resolved
Properly adjust the magnetic compass at the pilot house in accordance with SOLAS Chapter V, Reg 19.2 and IMO Resolution A.382 (X)
Action required: 705 - Other - as specified
Due 26 May 2007
Resolved 7 May 2007
Resolution: Magnetic compass in the pilot house adjusted with a deviance of less than 3 degrees.
Documentation › Safety Management System › Critical Equipment/Systems ID Procedures
Issued 7 January 2005
Resolved
PSTP must be updated & submitted to ABS for approval to ensure the document is in a step-by-step format adequate test inst that specify equip status, necessary apparatus, safety precautions & control & alarm set points, procedures top follow, & expected results req'd by US Supplement to ABS Rules for Steel Vsls <90 Meters, Cite:4/11.1.4.
Action required: 705 - Other - as specified
Due 31 May 2005
Resolved 5 July 2005
Resolution: Vessel submitted and received approved copy of the automation test procedures from ABS.
Engineering
Issued 15 October 2001
Resolved
PROVIDE FOR REVIEW, PLANNED MAINTENANCE PROGRAM AS PER THE U.S. SUPPLEMENT TO ABS RULES FOR STEEL VESSELS UNDER 90 METERS FOR VESSELS ON INTERNATIONALVOYAGES DATED 29MAR99, SECTION I, SHIPBOARD AUTOMATIC OR REMOTE CONTROL ANDMONITORING SYSTEMS -GENERAL- REQUIRED PLANS AND DATA, CITE 4.11.1.4 LEGACY COMPONENT DESC: PLANNED MAINTENANCE PROGRAM
Action required: 705 - Other - as specified
Due 25 November 2001
Resolved 18 December 2002
Resolution: Review ABS approved Planned Maintenance Program for the subject vessel. Planned Maintenance Program has been implemented since August 2002. Reviewed all maintenance check sheets as per approved planned maintenance program.
Engineering
Issued 15 October 2001
Resolved
DEMOSTRATE THE PROPER OPERATION OF THE PRIMARY AND ALTERNATE CONTROLS, ALARMS, POWER SOURCES, TRANSFER OVERRIDE ARRANGEMENTS, INTERLOCK AND_x001C_ SAFETY CONTROLS IN ACCORDANCE WITH ABS APPROVED PERIODIC SAFETY TEST PROCEDURES. SEE ABS RULES FOR STEEL VESSELS, SECTION I, CITE: 4/11.1.4
Condition: Unknown
Due 25 November 2001
Resolved 18 December 2002
Resolution: All engineering system alarms and monitoring devices were examined and tested during the ABS and Coast Guard annual inspection. All systems tested satisfactory using the ABS approved periodic safety test procedures.
Fire Fighting
Issued 15 October 2001
Resolved
PROVIDE WING NUTS TO PAINT LOCKER VENT CLOSURE. THE MAIN INLETS AND OUTLETSOF ALL VENTILATION SYSTEMS SHALL BE CAPABLE OF BEING CLOSED FROM OUTSIDE THE SPACE BEING VENTILATED AS PER SOLAS 74(AMENDED)II-2/48 AND II-2/16.9.
Condition: Unknown
Due 25 November 2001
Resolved 6 November 2001
Fire Fighting
Issued 15 October 2001
Resolved
REPAIR AND PROVE OPERATION OF FIRE DOORS THROUGHOUT VESSEL. NUMEROUS FIRE DOORS CANNOT BE CLOSED/SEALED. SEE SOLAS 74(AMENDED)II-2/47.
Condition: Unknown
Due 26 October 2001
Resolved 6 November 2001
Lifesaving
Issued 15 October 2001
Resolved
REPAIR AND PROVE OPERATION OF STARBOARD LIFEBOAT DAVIT LIMIT SWITCH. SEE SOLAS 74(AMENDED)III/48.2.5 AND SOLAS 74(AMENDED)III/19.2.
Condition: Unknown
Due 25 November 2001
Resolved 6 November 2001
Fire Fighting
Issued 15 October 2001
Resolved
UPDATE FIRE CONTROL PLAN TO INDICATE THE VARIOUS FIRE SECTIONS ENCLOSED BY "A" CLASS AND "B" CLASS DIVISIONS. ALSO THE GRAPHIC SYMBOLS DEPICTED ON THE PLAN SHALL BE IN ACCORDANCE WITH IMO RESOLUTION A.654(16). SEE SOLAS 74(AMENDED)II-2/20.
Condition: Unknown
Due 25 November 2001
Resolved 2 August 2002
Resolution: Reviewed and approved revised fire control plan in accordance with SOLAS 74 (amended) II-2/20. Stamped four sets of plans and returned to vessel operator for placement on board vessel.
Lifesaving
Issued 15 October 2001
Resolved
REPAIR AND PROVE SATISFACTORY OPERATION OF BOTH PORT AND STARBOARD LIFEBOATLAUNCHING APPLIANCES FROM THE STORED MECHANICAL POWER SOURCE. SEE SOLAS 74(AMENDED)III/48.1.3 AND SOLAS 74(AMENDED)III/19.2.
Condition: Unknown
Due 26 October 2001
Resolved 6 November 2001
Fire Fighting
Issued 15 October 2001
Resolved
REPAIR AND PROVE OPERATION OF CO2 GAS SENSOR LOCATED IN PORT CO2 ROOM.
Condition: Unknown
Due 25 November 2001
Resolved 6 November 2001
Fire Fighting › Structural - A Class Divisions
Issued 15 October 2001
Resolved
WHERE CABLES PASS THROUGH WATERTIGHT OR FIRE-RATED BULKHEADS OR DECKS, THE PENETRATIONS ARE TO BE MADE THROUGH THE USE OF APPROVED STUFFING TUBES, TRANSIT DEVICES, OR POURABLE MATERIALS WHICH WILL MAINTAIN THE WATERTIGHT OR FIRETIGHT INTEGRTY OF THE BULKHEADS OR DECKS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 October 2003
Resolved 5 November 2003
Resolution: Examined penetrations and found properly packed.
Accommodation/Occupational Safety
Issued 15 October 2001
Resolved
REMOVE A/C JUMPER HOSE FROM ELECTRONICS ROOM TO FAN ROOM. VENTILATION DUCTS SHALL BE OF NON-COMBUSTIBLE MATERIALS AS PER SOLAS 74(AMENDED)II-2/48ANDII-2/16.1
Condition: Unknown
Due 25 November 2001
Resolved 6 November 2001
Lifesaving
Issued 15 October 2001
Resolved
DEMONSTRATE TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR THAT FALLS FOR SURVIVAL CRAFT ARE LONG ENOUGH FOR THE SURVIVAL CRAFT TO REACH THE WATER WITH THE SHIP IN ITS LIGHTEST CONDITION UNDER UNFAVORABLE CONDITIONS OF TRIM AND WITHT SHIP LISTED NOT LESS THAN 20 DEG.
Condition: Unknown
Due 26 October 2001
Resolved 6 November 2001
Construction/Loadline
Issued 15 October 2001
Resolved
REPAIR HYDRAULIC LEAKS ON CLASS III WATERTIGHT DOOR PIPING LOCATED AT WATERTIGHT DOOR NO.57 AND WATERTIGHT DOOR LOCATED ON AFT BULKHEAD OF AUXILLIARY MACHINERY SPACE.
Condition: Unknown
Due 25 November 2001
Resolved 6 November 2001
Accommodation/Occupational Safety
Issued 15 October 2001
Resolved
REMOVE NON-APPROVED WOOD DOORS INSTALLED IN WAY OF HELO DECK EGRESS PORT AND STARBOARD SIDE. ANY CHANGES TO THE VESSEL SHALL BE APPROVED BY THE AUTHORIZED ACP CLASS SOCIETY PRIOR TO INSTALLATION.
Condition: Unknown
Due 26 October 2001
Resolved 6 November 2001
Documentation
Issued 15 October 2001
Resolved
PROVIDE DOCUMENTATION THAT THE REQUIRED ANNUAL VESSEL INSPECTON FEE OF $1870.00 HAS BEEN PAID AS PER 46 CFR 2.10-101.
Condition: Unknown
Due 25 November 2001
Resolved 6 November 2001
System not recorded
Issued 15 October 2001
Resolved
SUBMIT A CORRECTIVE ACTION PLAN ADDRESSING THE CORRECTIVE ACTIONS TO BE TAKEN AND THE TIMELINE TO CLEAR OUTSTANDING CG-835S. THIS PLANS COURSE OF ACTION MUST BE SATISFACTORY TO BOTH CG [name withheld].
Condition: Unknown
Due 16 November 2001
Resolved 16 November 2001
Fire Fighting
Issued 15 October 2001
Resolved
REMOVE HOLD-BACK HOOKS/DEVICES TO ALL FIRE RESISTANT DOORS THAT ARE REQUIRED TO BE SELF-CLOSING. SEE SOLAS 74(AMENDED)II-2/47.2
Condition: Unknown
Due 26 October 2001
Resolved 6 November 2001
Fire Fighting
Issued 15 October 2001
Resolved
REPAIR AND PROVE SATISFACTORY OPERATION OF FIRE DETECTION AND ALARM SYSTEM AS PER SOLAS 74 (AMENDED)II-2/52. NOTED FAULT ON WHEELHOUSE FIRE ALARM PANEL.
Condition: Unknown
Due 26 October 2001
Resolved 6 November 2001
Lifesaving
Issued 15 October 2001
Resolved
REPAIR AND PROVE OPERATION OF EMERGENCY GENERATOR FUEL OIL SERVICE TANK SHUT-OFF VALVE AS PER SOLAS 74(AMENDED)II-2/15.2.5.
Condition: Unknown
Due 25 November 2001
Resolved 6 November 2001
Construction/Loadline
Issued 15 October 2001
Resolved
REPAIR AND PROVE PROPER OPERATION OF CLASS III WATERTIGHT DOOR LOCATED IN PORT ENGINE ROOM. NOTED THAT GUIDE WHEEL IS BROKEN CAUSING THE DOOR DRAG. SEE SOLAS 74(AMENDED)II-1/25-9/1.
Condition: Unknown
Due 25 November 2001
Resolved 6 November 2001
Fire Fighting
Issued 15 October 2001
Resolved
REPAIR AND PROVE PROPER OPERATION OF ROLL-UP FIRE DOOR LOCATED IN THE GALLEY. SEE SOLAS 74(AMENDED)II-2/47.
Condition: Unknown
Due 26 October 2001
Resolved 6 November 2001
Fire Fighting
Issued 15 October 2001
Resolved
ALL FIRE EXTINGUISHING APPLIANCE SHALL BE KEPT IN GOOD WORKING ORDER AS PERSOLAS 74(AMENDED)II-2/21.
Condition: Unknown
Due 25 November 2001
Resolved 6 November 2001
Lifesaving
Issued 15 October 2001
Resolved
RENEW LIFEBUOYS TO PORT AND STARBOARD SIDE BRIDGEWINGS. LIFEBUOYS INTENDEDTO OPERATE THE QUICK-RELEASE ARRANGEMENT PROVIDED FOR THE SELF-ACTIVATED SMOKE SIGNALS AND SEF-IGNITING LIGHTS SHALL HAVE A MASS SUFFICIENT TO OPERATE THE QUICK-RELEASE ARRANGEMENT. SEE SOLAS 74(AMENDED)III/31.1.7
Condition: Unknown
Due 26 October 2001
Resolved 6 November 2001
Lifesaving
Issued 15 October 2001
Resolved
REPAIR AND PROVE OPERATION OF QUICK RELEASE MECHANISMS FOR PORT AND STARBOARD NAVIGATION BRIDGE LIFEBUOYS AS PER SOLAS 74(AMENDED)III/7.1.3. NOTEDS THE QUICK RELEASE MECHANISM IS OBSTRUCTED BY INSTALLED VIDEO CAMERAS.
Condition: Unknown
Due 26 October 2001
Resolved 6 November 2001
Electrical
Issued 15 October 2001
Resolved
REPAIR AND PROVE OPERATION OF EMBARKATION AND MUSTER STATION LIGHTING. MUSTER AND EMBARKATION STATIONS SHALL BE ADEQUATELY ILLUMINATED BY LIGHTINGAS PER SOLAS 74(AMENDED)III/11.4 AND 11.5
Condition: Unknown
Due 26 October 2001
Resolved 6 November 2001
Electrical
Issued 15 October 2001
Resolved
PROVE OPERATION OF EMERGENCY GENERATOR. IT SHALL START AUTOMATICALLY UPON FAILURE OF THE MAIN SORCE OF ELECTRICAL POWER SUPPLY AS PER SOLAS 74(AMENDED)II-1/43.3.1.2.
Condition: Unknown
Due 26 October 2001
Resolved 6 November 2001
Electrical
Issued 15 October 2001
Resolved
ALL ELECTRICAL APPARATUS SHALL BE SO CONSTRUCTED AND SO INSTALLED AS NOT TOCAUSE INJURY WHEN HANDLED OR TOUCHED IN THE NORMAL MANNER AS PER SOLAS 74(AMENDED)II-1/45. INSTALL BLANKS IN ELECTRICAL DISTRIBUTION PANELS WHERECIRCUIT BREAKERS ARE MISSING.
Condition: Unknown
Due 25 November 2001
Resolved 6 November 2001
Fire Fighting
Issued 15 October 2001
Resolved
PROPERLY MOUNT APPROVED C02 FIRE EXTINGUISHER WITH APPROVED BRACKET IN MACHINESHOP. SEE SOLAS 74(AMENDED)II-2/21 AND U.S. SUPPLEMENT TO ABS RULESFOR STEEL VESSELS UNDER 90 METERS FOR VESSELS ON INTERNATIONAL VOYAGES DATED 29MAR99, SECTION II CITE: II-2/6.
Condition: Unknown
Due 25 November 2001
Resolved 6 November 2001
Accommodation/Occupational Safety
Issued 15 October 2001
Resolved
REMOVE CREW ACCOMMODATIONS FROM THE HOSPITAL SPACE. THE HOSPITAL SHALL BE USED FOR THE CARE OF THE SICK AND FOR NO OTHER PURPOSE. SEE U.S. SUPPLEMENT TO ABS RULES FOR STEEL VESSELS UNDER 90 METERS FOR VESSELS ON INTERNATIONAL VOYAGES DATED 29MAR99, SECTION III,B.8(b).
Condition: Unknown
Due 25 November 2001
Resolved 6 November 2001
Accommodation/Occupational Safety
Issued 15 October 2001
Resolved
REMOVE ACCOMMODATIONS WITH COMBUSTIBLE FURNISHINGS FROM FAN ROOM. ALL ACCOMMODATIONS FOR OFFICERS AND CREW SHALL MEET THOSE MINIMUM STANDAR AS NOTED IN THE U.S. SUPPLEMENT TO ABS RULES FOR STEEL VESSELS UNDER 90 METERSFOR VESSELS ON INTERNATIONAL VOYAGES DATED 29MAR99, SECTION III,B.
Condition: Unknown
Due 25 November 2001
Resolved 6 November 2001
Engineering
Issued 15 October 2001
Resolved
PROVIDE MECHANICAL MEANS OF CLOSING THE DRAINS OF ALL FUEL OIL AND BULK LUBRICATING OIL DISCHARGE CONTAINMENT THROUGHOUT THE VESSEL. SEE THE U.S. SUPPLEMENT TO ABS RULES FOR STEEL VESSELS UNDER 90 METERS IN LENGTH, SECTION III, CITE: 33 CFR 155.320
Condition: Unknown
Due 25 November 2001
Resolved 6 November 2001