VIVID DREAMS

VIVID DREAMS is a 1996 passenger vessel (inspected). The Coast Guard has recorded 12 inspections since 2016, most recently in May 2025, along with 27 deficiencies and 2 operational controls.

Records from 2016 to 2025. Most recent: inspection, 12 May 2025.

Built
1996
Last inspected
12 May 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 May 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCW6818
442269
Flag
UNITED STATES
Maury page id
psix-442269

Documentation record

Registered dimensions (L × B × D)40.0 ft × 12.0 ft × 3.0 ft
Registered tonnagegross 26 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLIGHT'N POWER BOATS · WINTERHAVEN, FL, UNITED STATES · built 1996
Hull materialFRP (Fiberglass)
PropulsionGasoline Engine
Hull shapeUNSPECIFIED
Hull configurationTwin Hull
Hailing portSOUTH LAKE TAHOE, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Simplified, Net Ton
26 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

12 inspections, each with its date, unit and type; 27 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

12 May 2025 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8130587
13 May 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7910069
15 May 2023 Internal Structural Exam · COI Inspection · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7680967
29 April 2022 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7440705
15 June 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7241584
15 June 2020 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6974730
5 April 2020 Deficiency Check · Plan Review "T" Boat
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6980482
2 October 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6826509
30 July 2018 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6495946
21 May 2018 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6417062
9 August 2017 DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6233086
26 April 2016 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5863213

Deficiency record · 27

11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 May 2025 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired. Life float shows signs of damage to overall structure and grab line attachment points. Repair/replace to MI satisfaction. 46 CFR 176.808(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 13 June 2025
Resolution: Completed satisfactory repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 May 2025 Resolved
Each item of lifesaving equipment determined by the Marine Inspector to not be in serviceable condition must be repaired. Life ring found damaged. Replace to MI satisfaction. 46 CFR 176.808(b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 May 2025
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 13 May 2024 Resolved
Fuel lines must be accessible, protected from mechanical injury, and effectively secured against excessive movement and vibration by the use of soft nonferrous metal straps which have no sharp edges and are insulated to protect against corrosion. Where passing through bulkheads, fuel lines must be protected by close fitting ferrules or stuffing boxes. All fuel lines and fittings must be accessible for inspection. Fuel hose on PORT/STBD side found to be secured to electrical cables. 46 CFR 182.455(b)(3)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 27 May 2024
Resolution: Operator provided photographs of proper fuel hose mounting.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 May 2024 Resolved
Each rescue boat and ring life buoy must be marked with Type II retro reflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. PORT side life float retro reflective found to be deteriorated. 46 CFR 185.604(i)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 1 July 2024
Resolution: Received photograph of replaced retroreflective material.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 29 April 2022 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Plastic cable pass through to battery compartment open to the elements. Submit repair proposal prior to credit drydock. 46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 May 2023
Resolution: Watertight sleaves and tubing installed to outboard controls.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 April 2022 Resolved
On a vessel of at least 26ft in length a visual and audible alarm must be provided ath operating station at each of the following spaces; A space with non-watertight closure, such as a space with a non-water tight hatch on the main deck. Ensure high water alarm is conectted to the operating station. 46 CFR 182.530(a)(3)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2022
Resolved 2 June 2022
Resolution: High water alarm added.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons and the vessel from electrical hazards. 02 holes were found in the port bulkhead leading from the battery compartment to the hull. Ensure watertight integrity is maintained. 46 CFR 183.200(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2022
Resolved 2 June 2022
Resolution: Holes were covered and sealed around the edges.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 29 April 2022 Resolved
A hatch exposed to the weather must be watertight. Weatherstripping on battery compartments worn and inoperable. Replace gasket material. 46 CFR 179.360(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2022
Resolved 2 June 2022
Resolution: Gasket material replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 29 April 2022 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its certificate of inspection giving considerations to a sea worthy hull. Deck between battery compartments and port battery support wasted and delaminating. Repair prior to credit drydock. 46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 May 2023
Resolution: Delaminated shelf for batteries is still in good structural condition. Compartment has been made watertight to prevent further delam.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 June 2020 Resolved
A submersible electric bilge pump used as a power bilge pump must be permanently mounted. Center compartment bilge pump mounting base broken/missing. Pump is plastic wired tied in place. Replace.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2020
Resolved 23 June 2020
Resolution: Operator provided photograph of newly installed bilge pump.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 June 2020 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Required items as listed in Table 160.041 missing.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2020
Resolved 1 July 2020
Resolution: Received photograph of new first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 June 2020 Resolved
As per 46 CFR 160.027-2, each life float must have Type II retroreflective material meeting subpart 46 CFR 160.018 on each side and end. Life float retroreflective tape wasted an requires renewal.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2020
Resolved 6 July 2020
Resolution: Photograph of new retroreflective tape affixed to life float
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 June 2020 Resolved
At each initial and subsequent inspection for certification the owner or operator shall be prepared to test and make available for inspection all item's in the ships outfit. The following ships outfits was not available to be sighted by the MI during the inspection: 1) portable radios used between the balloon pilot, launch/recovery personnel, and bridge. 2) hand tools suitable for cutting the tether lines. 3) propeller guards not installed on the launch/recovery vessel outboard lower units. 4) 160:B semi-portable fire extinguisher
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 22 June 2021
Resolution: Verified all equipment during annual inspection.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 3 October 2019 Resolved
Closed spaces containing gasoline fuel tanks shall have natural supply and mechanical exhaust ventilation. Port and Starboard fuel tank space and interconnected aft void spaces do not have mechanical exhaust ventilation. 46 CFR 182.15-45
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 April 2020
Resolved 17 June 2020
Resolution: Vessel removed fuel filter from aft void and relocated it to fuel tank space. Aft void bulkhead was sealed with firestop to seperated two spaces. Fuel tanks space determined to be partially enclosed and not needing mechanical ventilation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 October 2019 Resolved
Machinery shall be maintained to afford adequate protection against fire and explosion. Fuel Hoses for port and starboard tanks are cracking.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2020
Resolved 17 June 2020
Resolution: Fuel Hoses were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 August 2018 Resolved
Vessel must carry 3 orange smoke and 3 red flare distress signals. 2 flares are missing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 August 2018
Resolved 8 August 2018
Resolution: Vessel rep landed new flares onboard.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 August 2018 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International andInland Navigation Rules. Port (red) navigation light installation needs to be adjusted so the light is not obstructed. Must be repaired prior to operating at night or when visibility is below 01 NM.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 August 2018
Resolved 8 August 2018
Resolution: Vessel rep fixed installation.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 July 2018 Resolved
VSL must undergo an annual inspection within the 3 months before or after each anniversary date. VSL is currently overdue.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2018
Resolved 6 August 2018
Resolution: Conducted annual inspection
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 July 2018 Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marineinspector. All four portable fire extinguishers require annual servicing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 August 2018
Resolved 8 August 2018
Resolution: Technician conducted required servicing.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 July 2018 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents andinstructions. First aid kit is missing multiple required items.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2018
Resolved 8 August 2018
Resolution: Vessel rep had an approved first aid kit ordered and delivered.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 9 August 2017 Resolved
Label ring buoy with vessel name 46 CFR 185.604
Due 8 September 2017
Resolved 14 August 2017
Resolution: Ring buoy properly labelled with vessel name.
Lifesaving › Lifefloat › Paddle
Issued 9 August 2017 Resolved
Label life float paddles with vessel name. 46 CFR 185.604
Due 8 September 2017
Resolved 14 August 2017
Resolution: Paddles properly labelled with vessel name.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 August 2017 Resolved
Provide functioning float light for ring buoy 46 CFR 180.70d
Due 8 September 2017
Resolved 15 August 2017
Resolution: Owner purchased new float light.
Lifesaving › Hand Flares › Expired
Issued 9 August 2017 Resolved
Provide 2 additional flares for a total of 6.
Due 8 September 2017
Resolved 9 August 2017
Resolution: Purchased new flares.
Fire Fighting › Fire Bucket › Availability
Issued 9 August 2017 Resolved
Provide 1 additional fire bucket with lanyard.
Due 8 September 2017
Resolved 9 August 2017
Resolution: Added fire bucket to vessel.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 6 May 2016 Resolved
Conduct MOB Drills with newly assigned master and crew
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 5 September 2017
Resolution: Conducted MOB in AUG 2017.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 6 May 2016 Resolved
Install one B-II dry chemical portable extinguisher in aft accomodation space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 2 June 2016
Resolution: Vessel owner installed B-II in aft accomodation space.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.