MAURY USCG vessel records Sign in
← All vessels

CAPT WINNER II

CAPT WINNER II is a 1962 passenger vessel (inspected). The Coast Guard has recorded 25 inspections since 1984, most recently in October 1994, along with 42 deficiencies.

Records from 1984 to 1994. Most recent: inspection, 7 October 1994.

Built
1962
Last inspected
7 October 1994
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WS9475
Flag
UNITED STATES
—
Maury page id
psix-44230

Inspections, by type

…with no type recorded5
Years with a record 11 calendar years (1984–1994)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 32 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Gross Ton
17 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WS9475MMSI not assigned · expired · voluntarily equipped · granted 25 October 1995, cancelled 7 January 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 25

7 October 1994 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 860718
29 September 1994 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1176669
28 February 1994 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1377128
3 December 1993 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 848749
1 November 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1382688
1 April 1993 Hull Examination · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 839399
1 April 1993 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1146059
18 March 1993 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 834164
12 March 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1153490
20 July 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 946767
6 April 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 945037
3 March 1992 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 948756
12 December 1991 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 945510
14 November 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 938538
22 May 1990 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1265187
7 March 1990 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1253460
7 March 1989 Deficiency Check · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1201103
23 November 1988 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1207163
7 April 1988 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 892939
23 March 1988 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 989376
24 July 1987 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1000930
1 April 1987 Deficiency Check · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1328652
12 March 1986 Credit Drydock · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1309207
24 March 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1292086
14 December 1984 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1285258

Deficiency record · 42

Construction/Loadline
Issued 28 February 1994 Resolved
Drydock vessel to determine the extent of repairs necessary to hull caused by recent marine casualty. No passengers may be carried until appropriate repairs have been accomplished.
Condition: Unknown
Due 3 March 1994
Resolved 3 March 1994
Construction/Loadline
Issued 1 November 1993 Resolved
Clean engine lube oil from engineroom bilge and make ready for examination by inspector.
Condition: Unknown
Due 1 December 1993
Resolved 6 December 1993
Lifesaving
Issued 1 November 1993 Resolved
Repair or replace waterlights as necessary one on the ring life buoy and two attached to the life floats. This must be accomplished prior to any night operations and in no case later than 01 Dec 93.
Condition: Unknown
Due 1 December 1993
Resolved 6 December 1993
Construction/Loadline
Issued 1 November 1993 Resolved
Replace missing cleats port and starboard and sampson post in way of bow.
Condition: Unknown
Due 1 December 1993
Resolved 6 December 1993
Electrical
Issued 1 November 1993 Resolved
Remove unapproved light fixtures on main deck.
Condition: Unknown
Due 1 December 1993
Resolved 6 December 1993
Fire Fighting
Issued 1 November 1993 Resolved
Replace or repair hand fire/bilge pump prior to opertion of vessel with passengers on board and in no case later than 01 Dec 93.
Condition: Unknown
Due 1 December 1993
Resolved 6 December 1993
Lifesaving
Issued 1 November 1993 Resolved
Remove unmarked eleven man lifefloat from vessel.
Condition: Unknown
Due 1 December 1993
Resolved 6 December 1993
Engineering
Issued 18 March 1993 Resolved
renew p/s cutless bearings
Condition: Unknown
Due 18 March 1993
Resolved 18 March 1993
Construction/Loadline
Issued 18 March 1993 Resolved
install secondary kellson over area were cross plank is panting #3 comp._x001C_ aft(stbd.)this keelson to run from the next bulkhead fwd to next bulkhead aft._x001C_
Condition: Unknown
Due 18 March 1993
Resolved 18 March 1993
Construction/Loadline
Issued 12 March 1993 Resolved
SUBMIT REPAIR PROPOSAL TO CORRECT "PANTING" OF BOTTOM PLANKING IN #3 COMPARTMENT IN WAY OF AFT BULKHEAD STBD. SIDE.
Condition: Unknown
Due 30 April 1993
Resolved 4 May 1993
Lifesaving
Issued 12 March 1993 Resolved
REPLACE TWO LIFEFLOATS ON STARBOARD SIDE WITH NEW ONES.
Condition: Unknown
Due 12 March 1993
Resolved 12 March 1993
Construction/Loadline
Issued 12 March 1993 Resolved
UPON COMPLETION OF SATISFACTORY REPAIRS TO BOTTOM PLANKING IN #3 COMPARTMENT, CONDUCT AN UNDERWAY OPERATIONAL TEST IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 30 April 1993
Resolved 4 May 1993
Lifesaving
Issued 12 March 1993 Resolved
PROVIDE 9 ADDITIONAL ADULT AND 2 CHILD SIZE LIFE PRESERVERS.
Condition: Unknown
Due 12 March 1993
Resolved 12 March 1993
Lifesaving
Issued 12 March 1993 Resolved
RENEW RETROREFLECTIVE TAPE ON PFD'S AND RELABEL WITH VESSEL NAME.
Condition: Unknown
Due 12 March 1993
Resolved 12 March 1993
Construction/Loadline
Issued 3 March 1992 Resolved
REMOVE FLEX HOSE IN BILGE PIPING SYSTEM AND RENEW WITH METALLIC PIPING AND ENSURE EACH BRANCH LINE IS EQUIPPED WITH FUNCTIONAL CHECK VALVE.
Condition: Unknown
Due 3 May 1992
Resolved 16 March 1992
Navigation
Issued 3 March 1992 Resolved
PROVE PROPER OPERATION OF MASTHEAD LIGHT.
Condition: Unknown
Due 10 March 1992
Resolved 16 March 1992
Construction/Loadline
Issued 3 March 1992 Resolved
PROVE PROPER OPERATION OF SHUT-OFF VALVE FOR BILGE PIPING FORWARD OF COLLISION BULKHEAD.
Condition: Unknown
Due 3 April 1992
Resolved 7 April 1992
Construction/Loadline
Issued 3 March 1992 Resolved
SEAL PENETRATION IN AFT BULKHEAD OF ENGINEROOM IN WAY OF KEEL.
Condition: Unknown
Due 3 April 1992
Resolved 16 March 1992
Fire Fighting
Issued 3 March 1992 Resolved
INSTALL METAL FITTINGS AND NOZZLE ON FIRE HOSE.
Condition: Unknown
Due 10 March 1992
Resolved 16 March 1992
Engineering
Issued 3 March 1992 Resolved
REMOVE ALL FLEX HOSE FROM FUEL SUPPLY AND FUEL VENT AND REPLACE WITH METALLIC PIPE. TERMINATE FUEL VENT WITH 30X30 MESH METALLIC FLAME SCREEN.
Condition: Unknown
Due 3 May 1992
Resolved 16 March 1992
Engineering
Issued 3 March 1992 Resolved
PROVE PROPER OPERATION OF MAIN ENGINE TACHOMETERS.
Condition: Unknown
Due 3 April 1992
Resolved 16 March 1992
Accommodation/Occupational Safety
Issued 3 March 1992 Resolved
LABEL MSD OVBD VALVES, MARK "SEWAGE OVBD DISCHARGE, DO NOT OPEN IN U.S WATERS." AND SECURE VALVES IN CLOSED POSITION.
Condition: Unknown
Due 3 April 1992
Resolved 7 April 1992
Lifesaving
Issued 3 March 1992 Resolved
POST EMERGENCY CHECK-OFF LIST ONBOARD.
Condition: Unknown
Due 10 March 1992
Resolved 16 March 1992
Lifesaving
Issued 3 March 1992 Resolved
RENEW RETROREFLECTIVE TAPE ON ALL BOUYANT APPARATUS.
Condition: Unknown
Due 10 March 1992
Resolved 16 March 1992
Documentation
Issued 7 March 1989 Resolved
PROVIDE VALID FCC OPERATOR'S PERMIT FOR CAPTAIN.
Condition: Unknown
Due 7 March 1989
Resolved 7 March 1989
Lifesaving
Issued 7 March 1989 Resolved
PROVIDE 6 ADDITIONAL ADULT LIFE PRESERVERS. TOTAL NUMBER OF PASSENGERS ALLOWED REDUCED TO 68 UNTIL COMPLETE.
Condition: Unknown
Due 7 March 1989
Resolved 7 March 1989
Fire Fighting
Issued 7 March 1989 Resolved
ATTACH METALLIC NOZZLE TO FIRE HOSE.
Condition: Unknown
Due 7 March 1989
Resolved 7 March 1989
Engineering
Issued 7 March 1989 Resolved
PROVIDE PORTABLE BILGE PUMP.
Condition: Unknown
Due 7 March 1989
Resolved 7 March 1989
Navigation
Issued 7 March 1989 Resolved
INSTALL LOCKING NUTS ON STEERING LINKAGE.
Condition: Unknown
Due 7 March 1989
Resolved 7 March 1989
Navigation
Issued 7 March 1989 Resolved
PERMANENTLY ATTACH PORT RUNNING LIGHT COVER.
Condition: Unknown
Due 7 March 1989
Resolved 7 March 1989
Fire Fighting
Issued 7 March 1989 Resolved
HAVE ALL FIRE EXTINGUISHERS SERVICED BY QUALIFIED FACILITY.
Condition: Unknown
Due 7 March 1989
Resolved 7 March 1989
Documentation
Issued 7 March 1989 Resolved
PROVIDE VALID USCG LICENSE FOR OPERATOR.
Condition: Unknown
Due 7 March 1989
Resolved 7 March 1989
Lifesaving
Issued 7 March 1989 Resolved
REPAIR OR REPLACE REQUIRED RING BUOY.
Condition: Unknown
Due 7 March 1989
Resolved 7 March 1989
Lifesaving
Issued 7 March 1989 Resolved
RELABEL BUOYANT APPARATUS PASSENGER CAPACITY IN ACCORDANCE WITH MANUFACTURER'S TAG, PROVIDE WOOD SPACERS BETWEEN STACKED APPARATUS, LENGTHEN PAINTER TYING APPARATUS TOGETHER, PROVIDE ONE ADDITIONAL WEAK LINK OF PROPER SIZE, REMOVE UNAPPROVED APPARATUS FROM VESSEL.
Condition: Unknown
Due 7 March 1989
Resolved 7 March 1989
Engineering
Issued 7 March 1989 Resolved
SECURE EXHAUST LEAKS IN ENGINE SPACE.
Condition: Unknown
Due 7 March 1989
Resolved 7 March 1989
Documentation
Issued 7 March 1989 Resolved
PROVIDE THE FOLLOWING UP TO DATE PUBLICATIONS: SAILING DIRECTIONS, COAST PILOTS, LIGHT LIST, NOTICES TO MARINERS, TIDE TABLES, AND TIDAL CURRENT TABLES.
Condition: Unknown
Due 7 March 1989
Resolved 7 March 1989
Construction/Loadline
Issued 23 March 1988 Resolved
CAULK AFT ENGINE ROOM BULKHEAD FOR WATERTIGHTNESS.
Condition: Unknown
Due 23 March 1988
Resolved 23 March 1988
Documentation
Issued 23 March 1988 Resolved
PROVIDE VALID FCC RADIO OPERATOR'S PERMIT FOR VESSEL'S REGULAR OPERATOR.
Condition: Unknown
Due 23 March 1988
Resolved 23 March 1988
Lifesaving
Issued 23 March 1988 Resolved
RE-NEW TWO FLOAT-FREE LINKS FOR BUOYANT APPARATUS.
Condition: Unknown
Due 23 March 1988
Resolved 23 March 1988
Lifesaving
Issued 23 March 1988 Resolved
PROVIDE 45 ADDITIONAL ADULT AND 1 ADDITIONAL CHILD PFD.
Condition: Unknown
Due 23 March 1988
Resolved 23 March 1988
Electrical
Issued 23 March 1988 Resolved
INSTALL BATTERY CROSS-CONNECT CABLE TO TERMINALS WITH PERMANENT CONNECTORS.
Condition: Unknown
Due 23 March 1988
Resolved 23 March 1988
Construction/Loadline
Issued 24 March 1985 Resolved
REPAIR THE LEAKING ALONG THE STEM WHICH IS EVIDENT WHEN THE VESSEL IS U/W. REPAIR THE LEAKING ALONG THE CHINES OUTBOARD OF THE FUEL TANKS
Condition: Unknown
Due 24 March 1985
Resolved 24 March 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.