Records from 1985 to 2025. Most recent: inspection, 22 July 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 59
22 July 2025
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8191821
24 April 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7901293
29 August 2023
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7790258
17 May 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7690890
19 April 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7674802
18 May 2022
Internal Structural Exam · Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7454161
20 April 2022
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7491585
27 January 2021
Administrative Inspection · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7131914
21 July 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7013224
21 May 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6689309
7 May 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6679520
19 June 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6451153
6 June 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6168052
25 May 2016
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5887583
21 March 2016
COI Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5837423
10 June 2014
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4885540
11 July 2012
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4375734
23 August 2011
Simplified Stability Test
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4127739
28 May 2008
Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3222093
3 April 2007
Annual Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2901150
13 April 2006
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2608322
13 April 2005
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2337007
9 July 2004
Periodic Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2131293
28 June 2004
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2113785
10 July 2003
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1919844
10 June 2002
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1636766
27 April 2001
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1441840
10 April 2001
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1366468
19 April 2000
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1426445
5 April 2000
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1391356
18 May 1999
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 798851
13 May 1999
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 796728
22 April 1999
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 791005
22 February 1999
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1129562
29 April 1998
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 792275
16 April 1997
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1126570
16 April 1997
Hull Examination · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1368186
5 April 1996
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1433033
25 October 1995
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1184005
21 March 1995
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1139007
3 May 1994
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 862113
26 April 1994
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 864034
26 April 1993
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1460639
23 June 1992
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1253112
28 May 1992
Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 956082
18 May 1992
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1259598
27 April 1992
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1260731
21 June 1991
Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1210899
1 May 1991
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 918064
15 October 1990
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1222594
1 May 1990
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1233422
4 May 1989
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1034600
17 April 1989
Hull Examination · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 897449
6 May 1988
Re-Inspection · Drydock Extension
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1197622
13 January 1988
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1318304
15 April 1987
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1014650
15 April 1987
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1316154
21 April 1986
Credit Drydock · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1306859
14 May 1985
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 984014
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 July 2025
No resolution recorded
CG001: Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The vessel gone beyond 3 months of their annual inspection. Passengers may not be carried until an inspection is completed.
46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 April 2024
Resolved
Provision shall be made by means of plugs, covers. etc., to prevent the admission of air into the space protected. Vessel’s engine room is protected by a pre-engineered fire system and was not equipped with means to prevent the admission the air into the space. 46 CFR 181.20-35
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2024
Resolution: Operator submitted pictures of covers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 April 2024
Resolved
Where life preservers are stowed so that they are not readily visible to passengers, the containers in which they are stowed shall be marked "life preservers" and with the number contained therein, in at least 1 inch letters and figures. This legend shall indicate the separate stowage of children's life preservers. 46 CFR 180-25 (b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2024
Resolution: Operator submitted pictures of marked storage.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 May 2022
Resolved
The owner or managing operator shall notify the cognizant OCMI as far in advance as possible whenever a vessel is to undergo repairs or alterations affecting the safety of the vessel, together with the nature of any repairs or alterations contemplated. Hull repairs or alternations that affect the safety of the vessel include but are not limited to the replacement, repair, or refastening of planking. Transom planking in way of starboard corner, adjacent to starboard freeing port, is wasted and rotting. Submit repair proposal for OCMI approval prior to commencing repairs prior to completion of next dry-dock.
46CFR176.665(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 May 2023
Resolution: Repairs conducted are holding as well as origional construction. No further repairs or action unless for cause.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 May 2022
Resolved
The OCMI may require an inspection and testing whenever a repair or alteration is undertaken. Underway sea trial required to complete credit dry-dock prior to the carriage of passengers.
46CFR176.700(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2022
Resolution: Completed satisfactory sea trial and inspection of temporary repair.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 April 2021
Resolved
The manual operation cable jacket found rusted and beyond repair.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2021
Resolution: Vessel Owner had cable replaced and serviced.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 10 June 2014
Resolved
Provide on board current Certificate of Documention.
Action required: 705 - Other - as specified
Due 24 June 2014
Resolved 10 June 2014
Resolution: Received email scan of current COD which was placed onboard.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 June 2014
Resolved
Stbd running light is inop. Repair/Replace.
Action required: 705 - Other - as specified
Due 10 June 2014
Resolved 10 June 2014
Resolution: Repaired and check prior to departure.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 10 June 2014
Resolved
Main diesel engine rubber exhaust hose to be replaced by next dry-dock, May 2016.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 7 June 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 July 2012
Resolved
Life ring marker light inoperable.
Condition: Improper/Lack of Maintenance
Due 18 July 2012
Resolved 8 August 2012
Resolution: Replaced battery. Marker light, sat.
Engineering › Steering Gear System › Hydraulic Hose
Issued 11 July 2012
Resolved
Steering system supply line broken at cylinder ram. Repair or replace.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 August 2012
Resolution: Installed new J-1942 hoses.
Lifesaving › Lifefloat › Markings
Issued 11 July 2012
Resolved
Life float (white) must be a vivid orange/red color. Painted in accordance with 46 CFR 160.10.
Due 1 September 2012
Resolved 8 August 2012
Resolution: Life float painted orange.
Documentation › Certificates/Documents › Stability Letter
Issued 11 July 2012
Resolved
Stability letter not on board.
Due 18 July 2012
Resolved 11 July 2012
Resolution: Marine Inspector sent a copy of Stability Letter to [name withheld] via e-mail.
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 July 2012
Resolved
Forward cabin battery must be secure. Secure accordingly.
Condition: Improper/Lack of Maintenance
Due 18 July 2012
Resolved 8 August 2012
Resolution: Installed new approved battery tray, and secured with straps.
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 3 April 2007
Resolved
Vsl is utilizing a non-approved DC powered fire detection system for the engine compartment, replace with an approved system.
Action required: 705 - Other - as specified
Due 1 April 2008
Resolved 28 May 2008
Resolution: Tested and approved new pre-engineered fire boy system.
Documentation › Markings/Placards › Lifejacket Placard
Issued 13 April 2006
Resolved
Provide a copy of a life jacket donning placard.
Action required: 705 - Other - as specified
Due 14 April 2006
Resolved 14 April 2006
Resolution: Owner down loaded donning instructions.
Navigation › Piloting/Steering › US Coast Pilot
Issued 13 April 2006
Resolved
Provide a copy of the coast pilot.
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 14 April 2006
Resolution: Owner provided a copy of the coast pilot.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 13 April 2006
Resolved
Provide a copy of the inland navigation rules of the road.
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 14 April 2006
Resolution: Owner provided a copy of the inland navigation rules.
Lifesaving › Lifefloat › Paddle
Issued 13 April 2005
Resolved
Name of vessel on paddle
Due 22 April 2005
Resolved 18 April 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 13 April 2005
Resolved
Replace batter in 1 Water Light
Due 22 April 2005
Resolved 18 April 2005
Lifesaving › Hand Flares › Expired
Issued 13 April 2005
Resolved
Replace three orange flares.
Due 22 April 2005
Resolved 18 April 2005
Construction/Loadline › Hull › Hull Plating
Issued 28 June 2004
Resolved
Issued 835 letter requireing vessel to undergo for credit hull examination prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2004
Resolved 13 August 2004
Lifesaving › Buoyant Apparatus
Issued 10 July 2003
Resolved
Provide either 200 ft sea painter secured to vsl or 100 ft sea painter equipped w/ float-free link attached to vsl for 12 person life float.
Due 24 July 2003
Resolved 8 October 2003
Lifesaving › Lifebuoys
Issued 10 July 2003
Resolved
Repair grab line straps on lifering LEGACY COMPONENT DESC: Buoyant Lifeline
Due 24 July 2003
Resolved 8 October 2003
Stability › Watertight Integrity
Issued 10 July 2003
Resolved
Repair high water alarm buzzer
Due 24 July 2003
Resolved 8 October 2003
Documentation › Certificates/Documents
Issued 10 July 2003
Resolved
Post COI at operating station; copy is acceptable LEGACY COMPONENT DESC: Certificate of Inspection
Due 24 July 2003
Resolved 8 October 2003
Lifesaving › Buoyant Apparatus
Issued 10 June 2002
Resolved
PROVIDE WATERLIGHT FOR BUOYANT APPARATUS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2002
Resolved 30 June 2002
Lifesaving
Issued 27 April 2001
Resolved
PASSENGER COUNT RESTRICTED FIVE. VESSEL HAS ONE SEVEN PERSON BUOYANT APPARATUS.
Condition: Unknown
Due 27 May 2001
Resolved 17 July 2001
Navigation
Issued 27 April 2001
Resolved
PROVIDE UP TO DATE CHARTS OF OPERATING AREA.
Condition: Unknown
Due 27 May 2001
Resolved 17 July 2001
Lifesaving
Issued 27 April 2001
Resolved
PROVIDE EYEWASH FOR FIRST AID KIT.
Condition: Unknown
Due 27 May 2001
Resolved 17 July 2001
Lifesaving
Issued 19 April 2000
Resolved
Stitch grab-line for life ring buoy.
Condition: Unknown
Due 19 May 2000
Resolved 10 August 2000
Lifesaving
Issued 19 April 2000
Resolved
Retro tape buoyant apparatus with an approved type.
Condition: Unknown
Due 19 May 2000
Resolved 10 August 2000
Lifesaving
Issued 19 April 2000
Resolved
Retro-tape ring life buoy with an approved type.
Condition: Unknown
Due 19 May 2000
Resolved 10 August 2000
Construction/Loadline
Issued 5 April 2000
Resolved
Fasten 2 deck-beam vertical supports on port side aft.
Condition: Unknown
Due 5 May 2000
Resolved 9 August 2000
Construction/Loadline
Issued 5 April 2000
Resolved
Remove soft wood on port-side transom at water line, and preserve.
Condition: Unknown
Due 5 May 2000
Resolved 9 August 2000
Fire Fighting
Issued 22 April 1999
Resolved
Install fixed fire fighting system for engine compartment.
Condition: Unknown
Due 22 April 1999
Resolved 22 April 1999
Lifesaving
Issued 22 April 1999
Resolved
Replace waterlight with currently approved type 161.010.
Condition: Unknown
Due 22 April 1999
Resolved 22 April 1999
Lifesaving
Issued 22 April 1999
Resolved
Replace outdated aspirin in first aid kit.
Condition: Unknown
Due 22 April 1999
Resolved 22 April 1999
Lifesaving
Issued 16 April 1997
Resolved
RENEW RETRO REFLECTIVE TAPE ON 3 ADULT PFD'S PRIOR TO CARRYING PAX.
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Construction/Loadline
Issued 16 April 1997
Resolved
CLEAN, TREAT AND EPOXY ROTTED AREA IN STERN POST.
Condition: Unknown
Due 16 May 1997
Resolved 25 April 1997
Navigation
Issued 16 April 1997
Resolved
TIGHTEN RUDDER PACKING.
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Construction/Loadline
Issued 16 April 1997
Resolved
CLEAN DRY ROT (ANGEL HAIR) AND TREAT PLANKS, FRAMES ALONG TRANSOM, AND FRAMES ON STBD SIDE, AFT.
Condition: Unknown
Due 16 May 1997
Resolved 25 April 1997
Lifesaving
Issued 16 April 1997
Resolved
MAKE 3-6' LINE FOR RING BUOY WATERLIGHT AND ATTACH.
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Documentation
Issued 16 April 1997
Resolved
REPLACE FADED OIL POLLUTION PLACARD.
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Navigation
Issued 5 April 1996
Resolved
EMERGENCY BROADCAST PLACARD WAS NOT SIGHTED/POSTED NEAR RADIO.
Condition: Unknown
Due 30 April 1996
Resolved 23 May 1996
Construction/Loadline
Issued 5 April 1996
Resolved
DUE TO AGE OF VSL, AN UNDERWAY TEST IS REQUIRED BUT COULD NOT BE CONDUCTED DUE TO ROUGH WEATHER CONDITIONS.
Condition: Unknown
Due 30 April 1996
Resolved 23 May 1996
Lifesaving
Issued 5 April 1996
Resolved
VESSEL REQUIRES ONE ADDITIONAL ADULT PFD.
Condition: Unknown
Due 30 April 1996
Resolved 23 May 1996
Lifesaving
Issued 5 April 1996
Resolved
ONE ADULT JACKET TYPE PFD REQUIRES RENEWAL OF RETROREFLECTIVE TAPE.
Condition: Unknown
Due 30 April 1996
Resolved 23 May 1996
Lifesaving
Issued 27 April 1992
Resolved
PROVIDE 2 ADULT LIFE JACKETS AND 1 CHILD LIFE JACKET
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Lifesaving
Issued 27 April 1992
Resolved
REPLACE LIFELINE STRAPS ON BOUYANT APPARTUS
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Documentation
Issued 1 May 1991
Resolved
PROVIDE FCC OEPRATORS LICENSE
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Lifesaving
Issued 1 May 1991
Resolved
REMARK LIFE JACKET STORAGE
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Navigation
Issued 1 May 1991
Resolved
PROVIDE LIGHT LIST
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Electrical
Issued 1 May 1991
Resolved
BLOCK BATTERIES TO MINIMIZE MOVEMENT
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Documentation
Issued 1 May 1990
Resolved
OPERATOR MUST HAVE VALID FCC OPERATORS PERMIT
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Navigation
Issued 1 May 1990
Resolved
PROVIDE COPY OF LIGHT LIST
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Navigation
Issued 1 May 1990
Resolved
PLACE BOLT ON STEERING GEAR LINKAGE HEAD UP AND SECURE WITH DOUBLE NUT, LOCK NUT OR NUT/COTTER PIN
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Navigation
Issued 17 April 1989
Resolved
REPAIR AND PROVE PROPER OPERATION OF VSLS STERN LIGHT
Condition: Unknown
Due 17 April 1989
Resolved 17 April 1989
Engineering
Issued 17 April 1989
Resolved
CONDUCT UNDERWAY TEST
Condition: Unknown
Due 17 April 1989
Resolved 17 April 1989
Lifesaving
Issued 17 April 1989
Resolved
PROVIDE ONE ADDITIONAL ADULT PFD
Condition: Unknown
Due 17 April 1989
Resolved 17 April 1989
Lifesaving
Issued 17 April 1989
Resolved
PROVIDE WEAK LINK FOR BUOYANT APPARATUS
Condition: Unknown
Due 17 April 1989
Resolved 17 April 1989
Lifesaving
Issued 6 May 1988
Resolved
PROVIDE ONE ADULT PFD
Condition: Unknown
Due 6 May 1988
Resolved 6 May 1988
Lifesaving
Issued 6 May 1988
Resolved
PROVIDE NEW 60' LINE FOR LIFERING
Condition: Unknown
Due 6 May 1988
Resolved 6 May 1988
Fire Fighting
Issued 6 May 1988
Resolved
PROVIDE ONE B-II HAND FIRE EXTINGUISHER
Condition: Unknown
Due 6 May 1988
Resolved 6 May 1988
Fire Fighting
Issued 6 May 1988
Resolved
PROVIDE HOSES FOR 5 GPM FIRE PUMP
Condition: Unknown
Due 6 May 1988
Resolved 6 May 1988
Navigation
Issued 6 May 1988
Resolved
PROVIDE CORROSION RESISTANT KEEPERS FOR STEERING LINKAGE
Condition: Unknown
Due 6 May 1988
Resolved 6 May 1988
Engineering
Issued 6 May 1988
Resolved
PROVIDE 30X30 FLAME SCREEN AND FLEX CONNECTION FOR FUEL TANK VENT LINE
Condition: Unknown
Due 6 May 1988
Resolved 6 May 1988
Unknown
Issued 15 April 1987
Resolved
PROVIDE MEANS OF SECURING 8 DECK HATCHES AND PROVIDE CAPTIVE CHAINS. ALSO PROVIDE MEANS OF SECURING ENGINE BOX.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Unknown
Issued 15 April 1987
Resolved
RENEW BILGE DISCHARGE LINE. PVC PIPING IS ACCEPTABLE. FLEXIBLE HOSE MAY BE USED PROVIDED IT IS REINFORCED AND RESISTANT TO PETROLEUM PRODUCTS. PROVIDE MANUFACTURERS SPECIFICATIONS & DEMONSTRATE RESISTANCE TO PETROLEUM.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Construction/Loadline
Issued 15 April 1987
Resolved
PROVIDE MEANS OF SECURING EIGHT DECK HATCH COVERS AND PROVIDE CAPTIVE CHAINS. ALSO MEANS OF SECURING ENGINE BOX TO DECK.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Construction/Loadline
Issued 15 April 1987
Resolved
RENEW BILGE LINE TO ONE ELECTRIC BILGE PUMP. REPLACEMENT PIPING MAY BE METALLIC, RIGID NON-METALLIC OR NON-RIGID NON-METALLIC. THE LATTER SHALL BE REINFORCED & RESISTENT TO PETROLEUM PRODUCTS MFG SPECIFICATION SHALL BE PROVIDED TO DEMONSTRATE RESISTENCE TO PETROLEUM PRODUCTS. PIPING SHALL BE
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987