Records from 1996 to 2026. Most recent: inspection, 5 January 2026.
Inspection history · 39
5 January 2026
Administrative Inspection · Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8295681
18 December 2024
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8048754
24 April 2024
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7900411
6 September 2023
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7786157
25 January 2023
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7626701
19 July 2022
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7510718
21 March 2022
Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7413395
25 August 2021
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7296366
18 May 2021
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7181568
9 April 2021
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7171975
27 October 2020
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7085151
15 September 2020
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7059420
15 September 2020
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7062756
23 March 2020
Annual Inspection · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6927336
19 March 2019
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6631692
15 March 2018
Hull Examination · Drydock Exam · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6363561
20 June 2017
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6182188
21 March 2017
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6096560
8 March 2016
COI Inspection · Hull Examination · Drydock Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5822484
15 May 2014
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4859572
24 March 2014
Annual Inspection · Deficiency Check · Drydock Exam · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4819916
13 September 2011
Simplified Stability Test
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4142687
15 April 2009
DAPI Audit · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3453369
2 February 2009
Type not recorded
No type recorded · Violation Case Coordination Center · Activity 3403925
25 May 2008
Type not recorded
No type recorded · Station Fort Macon · USCG East District (CGD-E) · Activity 3216697
28 April 2008
Annual Inspection · Drydock Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3189103
27 March 2007
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2895329
11 April 2006
COI Inspection · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2624196
2 July 2005
Type not recorded
No type recorded · Station Fort Macon · USCG East District (CGD-E) · Activity 2413193
26 April 2005
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2343153
8 April 2004
Re-Inspection · Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2040000
16 April 2003
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1777871
22 April 2002
Re-Inspection · Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1607842
12 April 2001
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1417257
9 May 2000
Re-Inspection · Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1408513
12 May 1999
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1471712
18 August 1998
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 139426
14 May 1998
Plan Review "T" Boat · Initial Certification · Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1411686
10 May 1996
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 224557
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 January 2026
Resolved
Your vessel must undergo an annual inspection withing the 3 months before or after each anniversary date. Your vessel was not made ready for the annual inspection. Your vessel must conduct an annual inspection prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 February 2026
Resolution: Completed annual inspection, all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 April 2024
Resolved
(a)The owner or managing operator shall make a vessel available for drydock examinations, internal structural examinations, and underwater surveys (UWILD) required by this section. (1)A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel's hull dates lapsed on current/valid COI. Vessel owner was educated and deficiency was cleared.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 24 April 2024
Resolved 24 April 2024
Resolution: Vessel owner was educated and deficiency was cleared.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 October 2023
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: (1) Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Both fire extinguishers not being properly maintained.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 4 October 2023
Resolution: Certified fire company came onboard and serviced the extinguishers.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 October 2023
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must have the vessel ready for inspection of its fire protection equipment. Two fire buckets found not serviceable. Renew in kind.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 4 October 2023
Resolution: Owner installed additional fire bucket onboard and in service.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 4 October 2023
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Hydrostatic release mechanism is expired.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 4 October 2023
Resolution: Restricted to LBS. New hydrostatic release mechanism installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 October 2023
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Ten adult sized life-jackets found not serviceable. Renew in kind.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 4 October 2023
Resolution: Owner renewed 10 adult sized life jackets and placed in service prior to departing.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 October 2023
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. Aspirin is expired.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 4 October 2023
Resolution: New aspirin placed in the first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 October 2023
Resolved
Each item of lifesaving equipment carried on board a vessel but not required under this part, must be approved by the Commandant. Additional life ring buoy line is not to be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Remove or provide proper line.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 4 October 2023
Resolution: Improper line for additional life ring buoy was removed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 January 2023
Resolved
A vessel inspected under Subchapter-T is required to be maintained iaw the terms of the Certificate of Inspection. Multiple deficiencies were identified during a coursery walk around of the vessel. Vessel must complete an In-Service Inspection to the satisfaction of the attending marine inspector prior to resuming operations. 46 CFR 176.100
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 October 2023
Resolution: COI inspection conducted on this date.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 July 2022
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Provide proper brackets for both portable extinguishers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2022
Resolved 29 July 2022
Resolution: Brackets installed and accepted by attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 July 2022
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Identification of the items may be in words, or the appropriate symbols in IMO Resolution A.760(18) Letters and numbers must be at least 2 inches high. Symbols must be at least 4 inches square. Properly label life jackets stowage containers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2022
Resolved 29 July 2022
Resolution: Lifejacket stowage compartments properly marked.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2021
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without
the approval of the cognizant OCMI, except during an emergency. During inspection MI noticed the bimini top was added after stability test was witnessed in 2011 and letter was issued. This alteration was not approved by the OCMI and must be removed.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 25 August 2021
Resolved 26 August 2021
Resolution: Forward Bimini top was properly removed from the vessel.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 25 August 2021
Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. Install proper lock nut on steering tiller arm.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2021
Resolved 26 August 2021
Resolution: Nylock nut was installed on the steering tiller.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2021
Resolved
Found loose wire on main electrical bus bar. Properly secure.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 1 June 2021
Resolution: Wire was properly tightened.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 May 2021
Resolved
Provide adequate watertight container for distress signals.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 2 June 2021
Resolution: Watertight container was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 May 2021
Resolved
02 day distress signals were expired.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2021
Resolution: 02 day distress signals onboard and up to date.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 May 2021
Resolved
Provide 11 adult sized lifejackets and properly label. Vessel is restricted to 08 passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 June 2021
Resolution: 11 new adult sized life jackets provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 May 2021
Resolved
Provide 01 child sized lifejacket. Vessel is restricted to 01 child passenger.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 June 2021
Resolution: Provided 01 child sized life jacket.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 May 2021
Resolved
Bilge pump discharge hose is loose.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2021
Resolution: Bilge pump hose clamp tightened.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 18 May 2021
Resolved
Properly install EPIRB and provide NOAA registration. Vessel is restricted to lakes, bays, and sounds.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 June 2021
Resolution: EPIRB is properly registered and sticker affixed on the device.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 May 2021
Resolved
First aid kit expired item. Provide aspirin tablets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 1 June 2021
Resolution: Aspirin was added to the kit.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 18 May 2021
Resolved
Provide navigational publications; light list, coast pilot, nav rules.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 1 June 2021
Resolution: Nav pubs onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 May 2021
Resolved
Provide additional lifering buoy IAW COI.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2021
Resolution: Additional life ring buoy was added, properly marked, and installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 May 2021
Resolved
Properly attach waterlight around the ring buoy body.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2021
Resolution: Line for waterlight was attached to the body
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 18 May 2021
Resolved
Helm is leaking fluid. Make effective repairs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 1 June 2021
Resolution: Made effective repairs on the helm and tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 May 2021
Resolved
Properly label lifejacket stowage compartment.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 2 June 2021
Resolution: Life jacket stowage was properly marked.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 9 April 2021
Resolved
Vessel COI expired on 08Apr21. Conduct an inspection for renewal of a certificate of inspection to the satisfaction of the Coast Guard, prior to the carriage of passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2021
Resolution: Completed COI, vessel found not fit for service as per activity number 7181568. All remaing defs are in attached activity number.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 September 2020
Resolved
Owner reported loss of fuel, caused by bad o-ring on fitting. Prove proper repairs and operation by attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2020
Resolved 15 September 2020
Resolution: New fuel fitting installed. MIs verified repairs.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 15 September 2020
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2020
Resolved 15 September 2020
Resolution: Master retrieved license from home post incident and provided valid documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 March 2020
Resolved
Replace nut on steering tiller arm to engine. Improper hardware for steering system.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2020
Resolved 3 April 2020
Resolution: Received, reviewed, and accepted objective evidence from company proving the outstanding item was resolved satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 March 2020
Resolved
The propeller castle nut was loose.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2020
Resolved 3 April 2020
Resolution: Received, reviewed, and accepted objective evidence from company proving the outstanding item was resolved satisfactory.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 March 2020
Resolved
The outboard fuel oil hose is cracked and damaged.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2020
Resolved 3 April 2020
Resolution: Received, reviewed, and accepted objective evidence from company proving the outstanding item was resolved satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 March 2020
Resolved
Povide proof of fire fighting servicing for extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2020
Resolved 3 April 2020
Resolution: Received, reviewed, and accepted objective evidence from company proving the outstanding item was resolved satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 March 2019
Resolved
Secure fuel tanks
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2019
Resolved 1 April 2019
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 19 March 2019
Resolved
Renew portable lighting due to dimness & corrosion.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2019
Resolved 1 April 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 March 2019
Resolved
Provide 3 missing fire buckets
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2019
Resolved 1 April 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 March 2019
Resolved
Repair masthead light (not operable)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2019
Resolved 1 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 March 2019
Resolved
Repair start/stop keyswitch
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2019
Resolved 5 April 2019
Resolution: Tech. Rep cleaned corroded Connections.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical care
Issued 19 March 2019
Resolved
Provide updated drug consortium info
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2019
Resolved 1 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 March 2019
Resolved
Provide 19 adult lifejackets (all adult jackets were condemned due to U/V deterioration.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2019
Resolved 1 April 2019
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 March 2018
Resolved
Wasted handrail hardware replace as marked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 April 2018
Resolved 8 May 2018
Resolution: Owner drilled new holes and added hardware for many fasteners.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 March 2018
Resolved
Handrail cracked port aft
Action required: 705 - Other - as specified
Due 3 April 2018
Resolved 8 May 2018
Resolution: Rewelded crack
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 March 2018
Resolved
Embarkation locations replace worn lines and clip to meet CG standard.
Action required: 705 - Other - as specified
Due 3 April 2018
Resolved 8 May 2018
Resolution: Owner added safety chains to vessel.
Construction/Loadline › Structures › Deck Plating
Issued 20 March 2018
Resolved
FWD peak remove FRP and replace as per owner.
Action required: 705 - Other - as specified
Due 3 April 2018
Resolved 8 May 2018
Resolution: Owner removed loose FRP and reglassed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 20 March 2018
Resolved
FWD peak bulkhead wasted at deck
Action required: 705 - Other - as specified
Due 3 April 2018
Resolved 8 May 2018
Resolution: Owner removed rot and reglassed. The owner left a large opening at the bottom of the bulkhead for water to drain, inspectors are to ensure no loss of structural strength during next annual inspection.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 March 2018
Resolved
First aid kit does not meet CG approval.
Action required: 705 - Other - as specified
Due 3 April 2018
Resolved 8 May 2018
Resolution: New first aid kit installed.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 20 March 2018
Resolved
Conduct MOB/Fire and underway trails
Action required: 705 - Other - as specified
Due 3 April 2018
Resolved 8 May 2018
Resolution: Conducted ops test of vessel, MOB completed on sister vsl.
Engineering › Fuel Oil Service System › Hose
Issued 21 March 2017
Resolved
Replace 12" section of fuel hose due to rot and cracking from filter to primer bulb.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2017
Resolved 20 June 2017
Resolution: Replaced fuel hose and primer bulb with new.
Engineering › Fuel Oil Service System › Pump
Issued 21 March 2017
Resolved
Replace fuel primer bulb due to rot and cracking.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2017
Resolved 20 June 2017
Resolution: Replaced new hose and primer bulb
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 21 March 2017
Resolved
Replace one rotted adult and child PFD and ensure correct amount are onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2017
Resolved 20 June 2017
Resolution: replaced lifejacket and added childs life jackets to match marking on vessel and COI
Construction/Loadline › Structures › Superstructure
Issued 21 March 2017
Resolved
T-top welds crack in two places. Fwd cross member and trans cross member.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 28 March 2017
Resolved 20 June 2017
Resolution: repaired two cracked welds in T-top
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 March 2016
Resolved
Attending Inspectors identified fractured weldments IWO hand rails and canopy supports.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 8 April 2016
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 8 March 2016
Resolved
Portable fire extinguisher missing IWO operators station/helm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 8 April 2016
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 8 March 2016
Resolved
The stowage location for the Child PFD's were not marked properly (missing quantity).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 8 April 2016
Navigation › Piloting/Steering › Marine Charts
Issued 8 March 2016
Resolved
Vessel was not equipped with approved Marine Charts for areas transited.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 8 April 2016
Navigation › Piloting/Steering › Coast Guard Light List
Issued 8 March 2016
Resolved
Vessel not equipped with Coast Guard Light List.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 8 April 2016
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 8 March 2016
Resolved
Vessel not equipped with tidal/current tables for areas transited.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 8 April 2016
Navigation › Piloting/Steering › US Coast Pilot
Issued 8 March 2016
Resolved
Vessel not equipped with Coast Pilot or extracts for areas transited.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 8 April 2016
Documentation › Markings/Placards › Certificate of Number (state)
Issued 24 March 2014
Resolved
Vessel not equipped with hull markings (State numbering) IWO port & starboard bow.
Action required: 705 - Other - as specified
Due 23 April 2014
Resolved 26 June 2014
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 March 2014
Resolved
Vessels stern light was inoperable at time of inspection due to electrical short.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2014
Resolved 26 June 2014
Construction/Loadline › Penetrations › Weld
Issued 24 March 2014
Resolved
Attending inspectors noted numerous fractures in weldments for the canopy structure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2014
Resolved 26 June 2014
Engineering › Bilge Water Management System › Hose
Issued 24 March 2014
Resolved
Bilge pump discharge hoses were not properly secured with double hose clamps at pumps and hull penetrations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2014
Resolved 26 June 2014
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 24 March 2014
Resolved
Portable fire extinguishers required annual servicing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2014
Resolved 26 June 2014
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 March 2014
Resolved
Water light battery required replacement (annual service)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2014
Resolved 26 June 2014
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 24 March 2014
Resolved
PFD stowage locations are not marked properly (quantity/type)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2014
Resolved 26 June 2014
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 March 2014
Resolved
Vessel's forward rail courses (line w/clip) have been shortened due to weather/service. Requires extension in order to secure properly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 April 2014
Resolved 26 June 2014
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 March 2014
Resolved
Vessel not equipped with lower rail courses at port & starboard embarkation stations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 April 2014
Resolved 26 June 2014
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 March 2014
Resolved
Expired medications in First Aid Kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2014
Resolved 26 June 2014
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 24 March 2014
Resolved
Type I PFD's retro-reflective tape was worn/deteriorated (numerous). Vessel owner to provide new retro-reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2014
Resolved 26 June 2014
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 24 March 2014
Resolved
Attending inspectors noted that the vessels anchor chain was severely wasted and required replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2014
Resolved 26 June 2014
Navigation › Piloting/Steering › Coast Guard Light List
Issued 24 March 2014
Resolved
Vessel not equipped with CG Light List or extracts of areas transited.
Action required: 705 - Other - as specified
Due 23 April 2014
Resolved 26 June 2014
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 24 March 2014
Resolved
Vessel not equipped with Inland Navigation Rules (33 CFR Part 83).
Action required: 705 - Other - as specified
Due 23 April 2014
Resolved 26 June 2014
Navigation › Piloting/Steering › US Coast Pilot
Issued 24 March 2014
Resolved
Vessel not equipped with Coast Pilot (IV).
Action required: 705 - Other - as specified
Due 23 April 2014
Resolved 26 June 2014
Construction/Loadline › Hull › Stringer
Issued 24 March 2014
Resolved
Attending inspectors noted that the main deck support (fwd) was severely deteriorated/rotted and required replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2014
Resolved 26 June 2014
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 15 April 2009
Resolved
Wrong name is marked on life ring.
Action required: 705 - Other - as specified
Due 23 April 2009
Resolved 23 April 2009
Resolution: Corrected on spot
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 15 April 2009
Resolved
Replace retro tape on 4 lifejackets
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 28 April 2010
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 27 March 2007
Resolved
Replace retro on five adult L/J and on two Childs L/J. Passenger count reduced by five adults until Lifejackets are repaired/replaced.
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 28 April 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 27 March 2007
Resolved
Properly mount two BII extinguishers. Existing extinguishers are held in place by bungee cords only, provide manufactures brackets or equivalent.
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 28 April 2008
Engineering › Bilge Water Management System › Pump
Issued 27 March 2007
Resolved
Properly mount bilge pump swich to console. Existing switch is wire tied to engine harness under console, not properly mounted in console as designed.
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 28 April 2008
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 March 2007
Resolved
Renew battery for float light, existing light flashing characteristics are slow. Replace/repair prior to night time operations
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 28 April 2008
Lifesaving › Lifejacket/PFD (Type IV) › Retroreflective Material
Issued 27 March 2007
Resolved
Renew retro on life ring. Existing retro tape is of the non-approved type and in poor condition.
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 28 April 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 March 2007
Resolved
Post CPR instructions onboard the vessel, must be readily available for use.
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 28 April 2008
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 27 March 2007
Resolved
Conduct training for crew and log IAW 46 CFR 185.420...TRAINING must include all required drills.
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 28 April 2008