Records from 1986 to 2007. Most recent: inspection, 11 June 2007.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 38
11 June 2007
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2958531
23 October 2006
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2806427
18 October 2006
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2803403
28 April 2006
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2636010
19 October 2005
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2526303
1 September 2005
COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2465141
13 April 2004
Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2040084
20 February 2004
Examination of Repairs · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1959469
11 September 2003
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1906260
8 April 2003
Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1767277
4 March 2003
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1719637
20 September 2002
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1677757
8 April 2002
Deficiency Check · Hull Examination · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1492106
6 April 2001
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1061762
17 April 2000
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1048679
10 April 2000
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1471401
23 April 1999
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1454674
21 January 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1125608
9 April 1998
COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1461031
13 February 1998
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1111548
18 June 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 8019
17 April 1997
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1407873
5 April 1996
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1468801
7 April 1995
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1442256
29 April 1994
Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1398043
21 April 1993
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 829747
21 April 1993
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1428207
30 April 1992
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1270854
7 April 1992
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1268400
30 April 1991
Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 921074
2 May 1990
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 909944
20 April 1990
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 907757
7 April 1989
COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1340195
17 August 1988
Examination of Repairs · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1037262
19 April 1988
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1034239
20 May 1987
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1008102
21 April 1987
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1033261
7 April 1986
Credit Drydock · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1306689
Operations/Management › Drills/Instruction › Not Conducted
Issued 19 October 2005
No resolution recorded
Prior to carrying passengers, sea trials and drills must be completed in the presents of a CG inspector. Item to be readdressed by due date.
Due 30 April 2006 — due date passed with no resolution recorded
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 1 September 2005
Resolved
Update life jacket placard to be more legible.
Due 2 October 2005
Resolved 19 October 2005
Resolution: Life jacket placard updated with new one.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 1 September 2005
Resolved
Renew retro tape on life ring.
Due 2 October 2005
Resolved 19 October 2005
Resolution: Retro reflective tape renewed on life ring.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 1 September 2005
Resolved
Clean Bilge of excess oil, remove absorbent pads.
Due 2 October 2005
Resolved 19 October 2005
Resolution: Bilges cleaned of excess oil and absorbent pads removed.
Engineering › Steering Gear System › Chain
Issued 1 September 2005
Resolved
Refasten rudder stop stbd side. Prior to carrying passengers.
Due 2 October 2005
Resolved 19 October 2005
Resolution: Rudder stop chain refastened.
Operations/Management › Drills/Instruction › Not Conducted
Issued 1 September 2005
Resolved
Conduct sea trials and drills prior to operating with passengers.
Due 2 October 2005
Resolved 19 October 2005
Resolution: Reissued new requirement.
Lifesaving › Inflatable Liferafts
Issued 13 April 2004
Resolved
Install liferaft, vessel is restricted to Lakes, Bays & Sounds and Rivers routes, within one mile of shore until the liferaft is properly installed on the vessel.
Due 15 May 2004
Resolved 4 May 2004
Resolution: Operator returned his liferaft after serving to the vessel, inspected installation.
Communications › Radio Communications › EPIRB
Issued 13 April 2004
Resolved
Return EPIRB to the vessel. Vessel is limited to Lakes, Bays and Sounds and Rivers routes until EPIRB is properly installed.
Due 15 May 2004
Resolved 4 May 2004
Resolution: Verified installation and EPIRB dates.
Construction/Loadline › Hull
Issued 20 February 2004
Resolved
Have vessel get underway for test of hull integrity in presence of attending CG marine inspector. Must be completed prior to the carriage of passengers. LEGACY COMPONENT DESC: Planking
Due 15 April 2004
Resolved 4 May 2004
Resolution: Completed during annual inspection.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 September 2003
Resolved
Make repairs to broken deck rail stanchions starboard side forward. Tighten and repair any loose or missing deck rail fasteners.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 September 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 8 April 2003
Resolved
Replace the one B1 fire extinguisher with an approved one and have the BII fire extinguisher located in the cabin hydrostatically tested. Must be completed prior to carriage of passengers. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Due 1 May 2003
Resolved 17 April 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 8 April 2003
Resolved
Renew the expired item in the first aid kit (aspirin). LEGACY COMPONENT DESC: First Aid Kit
Condition: Unknown
Due 1 May 2003
Resolved 17 April 2003
Construction/Loadline › Penetrations
Issued 4 March 2003
Resolved
Have vessel available for underway test to verify completeness of repair to the rudder post housing. To be completed prior to carrying passengers. LEGACY COMPONENT DESC: Rudder Post Housing
Condition: Improper/Lack of Maintenance
Due 1 May 2003
Resolved 8 April 2003
Construction/Loadline › Hull
Issued 6 January 2003
Resolved
Make stbd side #5 & #6 transverse frame heads and P&S #3 frame heads available for inspection by an attending CG marine inspector. Frames were refastened by master with agreement that he would permanently replace or sister the upper sections of the frames identified at next lay-up. LEGACY COMPONENT DESC: Transverse Frame
Due 15 January 2004
Resolved 8 April 2003
Construction/Loadline › Hull
Issued 6 January 2003
Resolved
Insert upper plank, port side (just fwd of pilot house side door) with new plank meeting criteria for proper plank repair noted in NVIC 7-95 (minimum 5 feet long or 6 frame spaces). Must be completed prior to carrying passengers. LEGACY COMPONENT DESC: Side Shell
Condition: Improper Installation
Due 1 April 2003
Resolved 21 March 2003
Construction/Loadline › Hull
Issued 6 January 2003
Resolved
Refasten outer long. stringer on bottom transverse floors in steering compt. Existing fasteners are severely corroded & stringer/floor joint is loose. This must be completed prior to carrying passengers. Will require an underway test to proof this & all other repairs completed this season. LEGACY COMPONENT DESC: Transverse Frame
Due 1 April 2003
Resolved 21 March 2003
Construction/Loadline › Hull
Issued 20 September 2002
Resolved
Prior to carriage of passengers, make available for inspection all frameheads in the engineroom and make repairs to all rotted frameheads throughout the vessel, to the satisfaction of the attending Coast Guard Marine Inspector.
Due 4 April 2003
Resolved 4 March 2003
Engineering › Bilge Water Management System
Issued 8 April 2002
Resolved
Renew bilge suction strainer in forward bilge area. LEGACY COMPONENT DESC: Strainer
Condition: Improper/Lack of Maintenance
Due 22 April 2002
Resolved 2 May 2002
Navigation › Electronic Positioning
Issued 8 April 2002
Resolved
Vessel ashore in boatyard during inspection. Item to be attended to by marine inspector after vessel is placed in water. LEGACY COMPONENT DESC: GPS/DGPS Receiver
Due 22 April 2002
Resolved 2 May 2002
Navigation › Collision/Grounding Avoidance
Issued 8 April 2002
Resolved
Vessel ashore in boatyard during inspection. Item to be attended to by marine inspector after vessel is placed in water. LEGACY COMPONENT DESC: Radar
Due 22 April 2002
Resolved 2 May 2002
Navigation › Piloting/Steering
Issued 8 April 2002
Resolved
Vessel ashore in boatyard during inspection. Item to be attended to by marine inspector after vessel is placed in water. LEGACY COMPONENT DESC: Magnetic Compass
Due 22 April 2002
Resolved 2 May 2002
Navigation › Collision/Grounding Avoidance
Issued 8 April 2002
Resolved
Vessel ashore in boatyard during inspection. Item to be attended to by marine inspector after vessel is placed in water. LEGACY COMPONENT DESC: Navigation Lights
Due 22 April 2002
Resolved 2 May 2002
Communications › Radio Communications
Issued 8 April 2002
Resolved
Vessel ashore in boatyard during inspection. Item to be attended to by marine inspector after vessel is placed in water. LEGACY COMPONENT DESC: VFH Radiotelephone
Due 22 April 2002
Resolved 2 May 2002
Construction/Loadline › Hull
Issued 8 April 2002
Resolved
Provide a repair proposal addressing correction of rot in frameheads throughout the vessel. LEGACY COMPONENT DESC: Transverse Frame
Condition: Improper/Lack of Maintenance
Due 22 April 2002
Resolved 16 April 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 8 April 2002
Resolved
Renew starboard side rail on deck where stanchion is broke through at #6 stanchion aft of bow. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 April 2002
Resolved 2 May 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 8 April 2002
Resolved
Renew gunwale between starboard side stanchions #7 through #10. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 April 2002
Resolved 2 May 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 8 April 2002
Resolved
Remove gunwale between starboard side stanchions #9 and #15 and renew rotted sections of gunwale, bulwark cap, and bulwark. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 April 2002
Resolved 2 May 2002
Construction/Loadline › Hull
Issued 8 April 2002
Resolved
Prove proper operation of engines, navigation equipment, and hull integrity to attending marine inspector after placing the vessel back into the water and prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 April 2002
Resolved 2 May 2002
Lifesaving › Lifejacket/PFD (General)
Issued 8 April 2002
Resolved
Provide light for lifejackets when operating more than 20 miles from a harbor of safe refuge. Passengers may not be carried when operating more than 20 miles from a harbor of safe refuge without lights on lifejackets. LEGACY COMPONENT DESC: Lights
Condition: Placed in Improper Service
Due 8 April 2002
Resolved 16 April 2002
Resolution: Changed vessel route to limited coastwise.
Construction/Loadline › Hull
Issued 8 April 2002
Resolved
Make available for inspection all frameheads in the engineroom and make repairs to all rotted frameheads throughout the vessel, to the satisfaction of the attending Coast Guard Marine Inspector. LEGACY COMPONENT DESC: Transverse Frame
Condition: Improper/Lack of Maintenance
Due 31 October 2002
Resolved 17 October 2002
Resolution: Item cleared and reissued for completion prior to carriage of passengers.
Construction/Loadline
Issued 6 April 2001
Resolved
Label bilge manifold valves with the name of the compartment each valve services in accordance with 46CFR176.800
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Construction/Loadline
Issued 6 April 2001
Resolved
Provide louder bilge alram at operating station as per 46CFR182.530
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Engineering
Issued 6 April 2001
Resolved
Label stbd emergency fuel shut off valve including direction of closure, asper 46CFR185.608
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Navigation
Issued 6 April 2001
Resolved
Provide updated Coast Pilot as per 46CFR184.420
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Navigation
Issued 6 April 2001
Resolved
Provide Emergency Broadcasting placard at radio station as per 46CFR184.506
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Navigation
Issued 6 April 2001
Resolved
Provide Emergency Instruction list at operating station as per 46CFR185.510
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Lifesaving
Issued 9 April 1998
Resolved
Conduct man overboard drill and undergo operational test/underway exam.
Condition: Unknown
Due 30 April 1998
Resolved 30 April 1998
Construction/Loadline
Issued 5 April 1996
Resolved
HAVE VESSEL AVAILABLE FOR UNDERWAY EXAM TO TEST STRENGTH AND WATERTIGHT INTEGRITY OF HULL. VESSEL MAY NOT CARRY PASSENGERS UNTIL CLEARED.
Condition: Unknown
Due 3 May 1996
Resolved 3 May 1996
Unknown
Issued 7 April 1992
Resolved
CONDUCT U/W TRIALS; TEST MAIN ENGINE, BILGE PUMP, STEERING, FATHOMETER AND WASH DOWN PUMPS.
Condition: Unknown
Due 7 April 1992
Resolved 7 April 1992
Construction/Loadline
Issued 20 April 1990
Resolved
MAKE VESSEL AVAILABLE FOR SEA TRIALS & TO CONDUCT TEST OF BILGE SYSTEM AND ELECTRONICS.
Condition: Unknown
Due 20 April 1990
Resolved 20 April 1990
Construction/Loadline
Issued 21 April 1987
Resolved
VESSEL TO BE MADE AVAILABLE FOR INSPECTION ONCE BACK IN WATER SO THE ENGINES, BILGE PUMPS, RADAR AND FATHOMETERS CAN BE OPERATIONALLY TESTED, AND TO EXAMINE SEAKEEPING ABILITY OF THE HULL.
Condition: Unknown
Due 21 April 1987
Resolved 21 April 1987