MAURY USCG vessel records Sign in
← All vessels

FISHFUL THINKING

FISHFUL THINKING is a 1962 passenger vessel (inspected). The Coast Guard has recorded 57 inspections since 1985, most recently in January 2016, along with 114 deficiencies and 2 casualty investigations between 2004 and 2016.

Records from 1985 to 2016. Most recent: inspection, 20 January 2016.

Built
1962
Last inspected
20 January 2016
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG9633
Flag
UNITED STATES
367059860, 367134960, 367149840, 367589760 (licence lapsed)
Maury page id
psix-44269

Inspections, by type

…with no type recorded8
Years with a record 29 calendar years (1985–2016)
The 57 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)55.1 ft × 16.5 ft × 3.7 ft
Registered tonnagegross 21 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEDWARD J REILLY · CAPE MAY, NJ, UNITED STATES · built 1962
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portFORT LAUDERDALE, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21 - Regulatory (Subpart C or D), Gross Ton
14 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG9633MMSI 367589760 · expired · compulsorily equipped · granted 14 September 2013, cancelled 18 November 2023
WDD4837MMSI 367149840 · expired · compulsorily equipped · granted 9 November 2006, cancelled 14 January 2017 · licensed under a name not among this hull’s recorded names (not shown)
WDD3701MMSI 367134960 · expired · compulsorily equipped · granted 16 August 2006, cancelled 22 October 2016 · licensed under a name not among this hull’s recorded names (not shown)
WDC6697MMSI 367059860 · expired · compulsorily equipped · granted 3 August 2005, cancelled 3 October 2015 · licensed under a name not among this hull’s recorded names (not shown)
WT5378MMSI not assigned · expired · compulsorily equipped · granted 6 January 1998, cancelled 31 May 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 57

20 January 2016 COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5800229
14 January 2016 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5811345
2 November 2015 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5755397
6 October 2014 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4999624
2 December 2011 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4200556
15 February 2011 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3945179
15 December 2009 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3664612
24 March 2009 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3439322
5 November 2008 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3357139
4 December 2007 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3109070
9 April 2007 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2904073
24 August 2006 COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2757533
17 March 2006 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2604414
11 August 2005 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2459420
21 March 2005 Hull Examination · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2314767
1 June 2004 Damage Survey
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2088640
30 May 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2084864
25 March 2004 Periodic Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2060419
16 December 2003 Type not recorded
No type recorded · USCGC DEPENDABLE (WMEC 626) · Activity 2008147
11 March 2003 Annual Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1753928
5 March 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1490749
23 March 2001 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1059859
9 March 2001 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1061221
23 March 2000 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1047102
30 March 1999 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1121301
16 February 1999 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1378612
24 March 1998 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 787180
20 January 1998 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 777319
27 March 1997 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1098112
28 March 1996 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1079725
22 March 1996 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1078591
3 April 1995 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 836076
29 March 1995 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 868859
20 March 1995 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1147157
31 March 1994 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1165790
7 March 1994 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1462379
19 March 1993 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 836211
16 February 1993 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1389623
18 March 1992 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 947978
13 February 1992 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1268313
11 March 1991 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1238606
12 February 1991 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1228226
23 March 1990 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1224807
7 March 1990 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 900923
20 March 1989 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1038519
8 March 1989 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1037356
28 March 1988 Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1193845
14 March 1988 Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1029076
27 October 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1017725
2 April 1987 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1329838
31 March 1987 Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1022224
25 March 1987 Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1021723
26 March 1986 Deficiency Check · COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1295116
21 March 1986 Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 999087
1 May 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 981477
1 April 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 981281
26 March 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 984179

Deficiency record · 114

Stability › Watertight Integrity › General
Issued 2 November 2015 Resolved
Adjust starboard and port shaft packing.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2015
Resolution: Crew adjusted shaft packing to correct excessive leaking.
Engineering › Lubricating Oil Service System › Gauge
Issued 2 November 2015 Resolved
Prove operation of lube oil and water temp gauges on port engine.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2015
Resolution: Verified operation of gauges.
Engineering › Sea-water System (primary cooling) › Piping
Issued 2 November 2015 Resolved
Repair raw water leak on port engine.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2015
Resolution: Verified correction of leak.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 2 November 2015 Resolved
Conduct underway drills. Crew failed to follow step one of the posted emergency procedures for man overboard: throw ring buoy.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2015
Resolution: Conducted underway drills and verified vessel's crew were familiar with their procedures.
Personnel › Training › First Aid/CPR
Issued 2 November 2015 Resolved
Vessel's crew were unfamiliar with basic first aid/CPR. Provide CPR training to 50% of crew.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 November 2015
Resolution: Verified crew's training.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 2 November 2015 Resolved
Provide fire extinguisher servicing report for fixed and portables.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2015
Resolution: Verified servicing of fixed and portable fire extinguishers and agent.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 November 2015 Resolved
Prove proper operation of stern light and correct arc of visibility.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2015
Resolution: Verified operation of light and correction of arc of visibility.
Lifesaving › Lifefloat › Paddle
Issued 2 November 2015 Resolved
Replace cracked paddle for lifefloat.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 November 2015
Resolution: Verified new paddle on board.
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 2 November 2015 Resolved
Provide new anchor line.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2015
Resolution: Verified new anchor line on board.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 November 2015 Resolved
Replace ring buoy floating water light battery.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2015
Resolution: Verified new battery on board.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 2 November 2015 Resolved
Destroy and replace 26 worn life jackets.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2015
Resolution: Verified new Type 1 PFDs on board.
Engineering › Fuel Oil Service System › Hose
Issued 6 October 2014 Resolved
Replace or make available for inspection both fuel tank supply lines and fittings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2014
Engineering › Fuel Oil Service System › Filter
Issued 6 October 2014 Resolved
Remove fuel from filter racor bowls and test system under load.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 October 2014
Stability › Weathertight Integrity › General
Issued 6 October 2014 Resolved
Make repairs to both engine room outboard hatch water tight covers.
Action required: 705 - Other - as specified
Resolved 20 October 2014
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 October 2014 Resolved
Provide new owner/operator address.
Action required: 705 - Other - as specified
Resolved 20 October 2014
Documentation › Certificates/Documents › FCC SSL
Issued 6 October 2014 Resolved
Provide FCC station license official number.
Action required: 705 - Other - as specified
Resolved 20 October 2014
Navigation › Piloting/Steering › Marine Charts
Issued 6 October 2014 Resolved
Provide all 2014 navpubs.
Action required: 705 - Other - as specified
Resolved 20 October 2014
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 October 2014 Resolved
Replace ring bouy and life float (aft) water light batteries IAW manufacture specs.
Action required: 705 - Other - as specified
Resolved 20 October 2014
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 6 October 2014 Resolved
Make distribution panel water tight.
Action required: 705 - Other - as specified
Resolved 9 October 2014
Communications › Radio Communications › VHF Radiotelephone
Issued 6 October 2014 Resolved
Provide emergency broadcast at console IAW 46cfr184.506
Action required: 705 - Other - as specified
Resolved 9 October 2014
Stability › Weathertight Integrity › General
Issued 6 October 2014 Resolved
Plug all bridge console holes.
Action required: 705 - Other - as specified
Resolved 20 October 2014
Engineering › Bilge Water Management System › Pump
Issued 6 October 2014 Resolved
Prove ops of the mate locker auto bilge pump.
Action required: 705 - Other - as specified
Resolved 9 October 2014
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 6 October 2014 Resolved
Replace fwd life float water light.
Action required: 705 - Other - as specified
Resolved 20 October 2014
Accommodation/Occupational Safety › Ventilation › General
Issued 6 October 2014 Resolved
Provide engine room vent covers/closures IAW 46cfr182.465.
Action required: 705 - Other - as specified
Resolved 9 October 2014
Electrical › Electrical Distribution System (service) › Cable
Issued 6 October 2014 Resolved
Protect all cabin top equip cables.
Action required: 705 - Other - as specified
Resolved 9 October 2014
Stability › Watertight Integrity › General
Issued 6 October 2014 Resolved
Make all subdivision compartments water tight.
Action required: 705 - Other - as specified
Resolved 20 October 2014
Electrical › Electrical Distribution System (service) › Cable
Issued 6 October 2014 Resolved
Replace dead end cables in mate locker and engine room fwd.
Action required: 705 - Other - as specified
Resolved 20 October 2014
Construction/Loadline › Structures › Transverse Bulkhead
Issued 6 October 2014 Resolved
Provide repair proposals for the following defs to be repaired by the next dry dock. 1. The steering compartment under deck cracked transverse frame (above stbd rudder post). 2. repair both e/r outboard water tight covers and deck beams. 3. remove soft patch and piping to the port MDE blower drive tube.
Action required: 705 - Other - as specified
Resolved 20 October 2014
Personnel › Training › Familiarization Training
Issued 6 October 2014 Resolved
Conduct u/w drills.
Action required: 705 - Other - as specified
Resolved 9 October 2014
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 6 October 2014 Resolved
Provide alcohol test swabs by 21Oct14.
Action required: 705 - Other - as specified
Resolved 20 October 2014
Operations/Management › Pollution › Control of Garbage
Issued 15 February 2011 Resolved
Provide waste management plan in accordance with 33 CFR 151.57
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 March 2011
Resolved 4 March 2011
Electrical › Lighting (service) › Lighting Fixture
Issued 15 February 2011 Resolved
provide magnetic compass light for night operations in accordance with 46 CFR 184.402
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2011
Resolved 4 March 2011
Electrical › Lighting (service) › Lighting Feeder
Issued 15 February 2011 Resolved
Renew wiring on mast head light.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 March 2011
Resolved 4 March 2011
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 February 2011 Resolved
Provide battery box cover in accordance with 46CFR183.350
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 March 2011
Resolved 4 March 2011
Personnel › Training › First Aid/CPR
Issued 15 February 2011 Resolved
Provide 50% of crew posses valid CPR/First aid training and certification card in accordance with NVIC 1-91.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 March 2011
Resolved 4 March 2011
Accommodation/Occupational Safety › Ventilation › General
Issued 15 February 2011 Resolved
Provide 30/30 screen on port side MSD vent at the top of the wheel house. In accordance with MSM Ch. 18.K.7.f(1)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 March 2011
Resolved 4 March 2011
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 15 February 2011 Resolved
Provide current navigation publications i.e. updated charts, coast pilot, tide tables, tidal currents, light list. In accordance with46 CFR184.420.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 March 2011
Resolved 4 March 2011
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 15 February 2011 Resolved
Provide first aid kit, fully outfitted with proper allotment of supplies. In accordance with 46 CFR 160.041
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 March 2011
Resolved 4 March 2011
Lifesaving › Lifefloat › Lifeline
Issued 15 February 2011 Resolved
Provide new becket lines.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2011
Resolved 4 March 2011
Lifesaving › Lifefloat › Paddle
Issued 15 February 2011 Resolved
Provide new paddles of the appropriate size and properly marked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2011
Resolved 4 March 2011
Lifesaving › Lifefloat › Painter
Issued 15 February 2011 Resolved
Renew painter line on lifefloat
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2011
Resolved 4 March 2011
Lifesaving › Lifefloat › Pendant
Issued 15 February 2011 Resolved
Provide new pendant lines on lifefloat.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2011
Resolved 15 February 2011
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 15 February 2011 Resolved
Provide or renew floating water light lense and battery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2011
Resolved 4 March 2011
Documentation › Certificates/Documents › FCC SSL
Issued 15 December 2009 Resolved
Provide a current fcc radio telephoney certificate
Action required: 705 - Other - as specified
Due 15 January 2010
Resolved 14 January 2010
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 15 December 2009 Resolved
Provide vessel logs and EPRIB testing reports.
Action required: 705 - Other - as specified
Due 17 December 2009
Resolved 17 December 2009
Navigation › Piloting/Steering › Compass Deviation Table
Issued 15 December 2009 Resolved
Provide a current compass deviation table.
Action required: 705 - Other - as specified
Due 15 January 2010
Resolved 14 January 2010
Lifesaving › Hand Flares › Storage
Issued 15 December 2009 Resolved
Stencil the hand held flare container "Distrerss Flares".
Action required: 705 - Other - as specified
Due 15 January 2010
Resolved 14 January 2010
Lifesaving › Lifefloat › Markings
Issued 15 December 2009 Resolved
Stencil the lifefloats and paddles with the vessel name.
Action required: 705 - Other - as specified
Due 15 January 2010
Resolved 14 January 2010
Engineering › Bilge Water Management System › Manifold
Issued 15 December 2009 Resolved
Stencil the high bilge indicating lights at the operating station to indicate which pump has been activated.
Action required: 705 - Other - as specified
Due 15 January 2010
Resolved 14 January 2010
Construction/Loadline › Hull › Transverse Frame
Issued 9 April 2007 Resolved
Prior to credit dry dock - all frame, knee and keel bolts that are wasted and unable to tighten nut due to severe corrosion, must be renewed with approved fastener. Keel bolts should be silicone bronze or monel. Frame bolts can be galvanized.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2007
Resolved 14 May 2007
Construction/Loadline › Hull › Hull Plating
Issued 9 April 2007 Resolved
Renew butt block in compartment 6 on port side inboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2007
Resolved 14 May 2007
Construction/Loadline › Hull › Keel
Issued 9 April 2007 Resolved
Garboard strake on starboard side near transducer shall be recaulked and sealed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2007
Resolved 14 May 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 9 April 2007 Resolved
Renew port engine exhaust manifold gasket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2007
Resolved 14 May 2007
Engineering › Fuel Oil Service System › Piping
Issued 9 April 2007 Resolved
Renew fuel supply pipes on port and starboard fuel tanks.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2007
Resolved 14 May 2007
Stability › Watertight Integrity › General
Issued 9 April 2007 Resolved
Make engine room hatch watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2007
Resolved 14 May 2007
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 9 April 2007 Resolved
Renew port and starboard cutlass bearings.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 May 2007
Resolved 14 May 2007
Engineering › Steering Gear System › Bracket/Clamp
Issued 9 April 2007 Resolved
Starboard rudder, upper support bracket - renew all fasteners.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2007
Resolved 14 May 2007
Construction/Loadline › Structures › Scuttle
Issued 9 April 2007 Resolved
Clean both aft scuttle gaskets and sealing surfaces.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2007
Resolved 14 May 2007
Stability › Freeing Ports › General
Issued 9 April 2007 Resolved
Repair all freeing port covers so that they lay flush and seal over hull opening.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2007
Resolved 14 May 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 24 August 2006 Resolved
Submit drawing for approval for fixed firefighting system IAW 181.410.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2006
Resolved 7 September 2006
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 24 August 2006 Resolved
Properly install fixed fire detection system IAW 181.400(c).
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2006
Resolved 7 September 2006
Stability › Watertight Integrity › General
Issued 24 August 2006 Resolved
Make hatch leading to generator space watertight and properly latch.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2006
Resolved 7 September 2006
Stability › Weathertight Integrity › General
Issued 24 August 2006 Resolved
Properly attach latchs to engine room covers to coamings to prevent covers from coming loose.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2006
Resolved 7 September 2006
Fire Fighting › Remote Fuel Shutoff › General
Issued 24 August 2006 Resolved
Properly attach screens around fuel shut off reach rods.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2006
Resolved 7 September 2006
Engineering › Bilge Water Management System › Valve
Issued 24 August 2006 Resolved
Properly install positive shut off valves on all electric submersible pumps at the spool piece.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2006
Resolved 7 September 2006
Resolution: Owner installed two wood plugs from the outside of the vessel on the aft penetration due to inaccessiblity of the spool piece.
Lifesaving › Lifefloat › Paddle
Issued 24 August 2006 Resolved
Provide two four foot paddles for second lifefloat.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2006
Resolved 7 September 2006
Lifesaving › Lifefloat › Markings
Issued 24 August 2006 Resolved
Mark all life floats and paddles with nake of vessl.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2006
Resolved 7 September 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 August 2006 Resolved
Provide new lenses for port and starboard navigation lights.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2006
Resolved 7 September 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 August 2006 Resolved
Properlt attach floating light to lifefloats.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2006
Resolved 7 September 2006
Lifesaving › Hand Flares › Quantity
Issued 24 August 2006 Resolved
Provide three daytime smoke flares.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2006
Resolved 7 September 2006
Navigation › Piloting/Steering › US Coast Pilot
Issued 24 August 2006 Resolved
Provide all required navigation publications.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2006
Resolved 7 September 2006
Lifesaving › Lifefloat › Lifeline
Issued 24 August 2006 Resolved
Provide new life line from life float to weak link.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2006
Resolved 7 September 2006
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 24 August 2006 Resolved
Properly mark ring life buoy with vessels name.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2006
Resolved 7 September 2006
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 24 August 2006 Resolved
Install approved non-combustible material on engine room hatch covers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2006
Resolved 7 September 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 March 2006 Resolved
Anchor light not functioning. Vessel limited to daytime operations.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 31 March 2006
Navigation › Piloting/Steering › Magnetic Compass
Issued 17 March 2006 Resolved
Magnetic compass not illuminated. Vessel restricted to daytime operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 March 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 March 2006 Resolved
Strobe light not within proper interval. Vessel limited to daytime operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 March 2006
Resolution: owner replaced battery.
Communications › Internal Communications System › Voice Tube
Issued 17 March 2006 Resolved
Public Announcement system not operable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2006
Resolved 31 March 2006
Communications › Radio Communications › EPIRB
Issued 17 March 2006 Resolved
EPIRB not registered with proper vessel name. Vessel restricted to within 3 miles of shore.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 31 March 2006
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 17 March 2006 Resolved
Bilge manifold in E/R and highwater alarms on dash not labeled properly.
Condition: Improper/Lack of Maintenance
Due 4 April 2006
Resolved 31 March 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 March 2006 Resolved
Aspirin and Eye Wash expired.
Condition: Improper/Lack of Maintenance
Due 4 April 2006
Resolved 31 March 2006
Resolution: NEW EYE WASH AND ASPIRIN ON-BOARD
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 17 March 2006 Resolved
Fire pump and installed bilge system inoperable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2006
Resolution: BILGE SUCTION FROM #5 COMPT. SAT
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 17 March 2006 Resolved
Stbd. exhaust hose leaking in lazarette.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2006
Resolution: REPLACED HOSE CLAMP AND STOPPED LEAK.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 17 March 2006 Resolved
PFD torn. Passenger count reduced by 1 until replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 March 2006
Resolution: REPLACED WITH NEW
Construction/Loadline › Hull › Transverse Frame
Issued 21 March 2005 Resolved
Found two broken bolts in the Forepeake's aft most floor-frame joint. Required owner to replace in kind.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2005
Construction/Loadline › Hull › Transverse Frame
Issued 21 March 2005 Resolved
Found engine compartment forward most transverse frame scarf joint bolts (2) wasted. One to port of keel and one to stbd of keel under battery tray. Required owner to replace in kind.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2005
Construction/Loadline › Hull › Side Shell
Issued 21 March 2005 Resolved
Plug blocks on the port & stbd side of the engine compartment were found to be rotted. Required owner to replace in kind.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2005
Engineering › Sea-water System (primary cooling) › Piping
Issued 21 March 2005 Resolved
Found stbd raw water intake flex hose to be badly deteriorated. Required owner to replace in kind.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2005
Engineering › Bilge Water Management System › Hose
Issued 21 March 2005 Resolved
Found flex hoses, in the tank compartment, joining sections of bilge system piping to be badly deteriorated. Required owner to replace with suitable hose.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2005
Construction/Loadline › Hull › Transverse Frame
Issued 21 March 2005 Resolved
Found broken bolt at the gusset-bottom frame joint, first frame aft of tank compartment fwd bulkhead, port side. Required owner to renew in kind.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2005
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 21 March 2005 Resolved
VESSEL MISSING 2 ADULT LIFE JACKETS. REDUCED PASSENGER COUNT UNTILL LIFE JACKETS ARE REPLACED.
Action required: 705 - Other - as specified
Resolved 21 April 2005
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 21 March 2005 Resolved
VESSEL MISSING CURRENT TIDE AND CURRENT CHARDT FOR AREA. PROVIDE WITH IN 14 DAYS.
Due 28 April 2005
Resolved 21 April 2005
Operations/Management › Equipment Service/Testing › EPIRB
Issued 21 March 2005 Resolved
HYDROSTATIC RELEASE WILL EXPIRE AT THE END OF APRIL. REPLACE WITH NEW IN KIND.
Due 30 April 2005
Resolved 21 March 2005
Resolution: OWNER CALLED LO0CAL TECH REP AND HE ARRIVED ON SCENE AND REPLACED WITH A NEW HYDRO RELEASE.
Lifesaving › Buoyant Apparatus
Issued 25 March 2004 Resolved
Provide water light lines for L/Fs with appropriate length.
Due 1 April 2004
Resolved 1 April 2004
Resolution: Water light lines for L/Fs replaced with appropriate length, (18) ft.
Engineering › Bilge Water Management System › Manifold
Issued 25 March 2004 Resolved
Label bilge manifold with appropriate comp't indicator.
Due 1 April 2004
Resolved 1 April 2004
Resolution: Bilge manifold labeled with appropriate indicators.
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 March 2004 Resolved
Label bilge alarm indicators on bridge with appropriate compts.
Due 1 April 2004
Resolved 1 April 2004
Resolution: All bilge high level alarm indicators on bridge appropriately labeled.
Navigation › Piloting/Steering › US Coast Pilot
Issued 25 March 2004 Resolved
Provide up to date Coast Pilot [name withheld], and Tide Current Tables.
Due 1 April 2004
Resolved 1 April 2004
Resolution: All up to date versions of required publications provided.
Lifesaving › Buoyant Apparatus
Issued 25 March 2004 Resolved
Secure weak links for L/Fs to the vessel.
Due 1 April 2004
Resolved 1 April 2004
Resolution: L/F weak links secured to vessel.
Engineering › Bilge Water Management System › Hose
Issued 25 March 2004 Resolved
Replace worn hose in way of bilge pipe, eng room.
Due 1 April 2004
Resolved 1 April 2004
Resolution: Support hose replaced with new.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 25 March 2004 Resolved
Stencil (7) adult L/Js with vessel name.
Due 1 April 2004
Resolved 1 April 2004
Resolution: Life jackets stenciled as required.
Electrical
Issued 24 March 1998 Resolved
REPAIR GENERATOR RAW WATER PUMP, DEMONSTRATE PROPER OPERATION.
Condition: Unknown
Due 24 April 1998
Resolved 2 April 1998
Lifesaving
Issued 28 March 1996 Resolved
RECONNECT KEEPER LINES ON ALL DECK HATCHES.
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Lifesaving
Issued 28 March 1996 Resolved
INSTALL RETROREFLECTIVE TAPE ON BOUYANT APPARATUS.
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Lifesaving
Issued 28 March 1996 Resolved
REPLACE WATERLIGHTS ON BUOYANT APPARATUS WITH APPROVED TYPE.
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Lifesaving
Issued 28 March 1996 Resolved
PRIOR TO OPERATING WITH MORE THAN 48 PASSENGERS, PROVIDE 16 APPROVED ADULT PFD'S.
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Lifesaving
Issued 29 March 1995 Resolved
REPLACE SIX OUTDATED ORANGE HAND FLARES.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Navigation
Issued 29 March 1995 Resolved
REPLACE OUTDATED LIGHT LIST.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Navigation
Issued 29 March 1995 Resolved
REPLACE OUTDATED CHART.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 20 March 1995 Resolved
PROVIDE VSL FOR UNDERWAY EXAM TO PROVE VSL SEAWORTHINESS AFTER DRYDOCK.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Lifesaving
Issued 31 March 1994 Resolved
PRIOR TO CARRYING PASSENGERS MORE THAN ONE MILE FROM LAND, REPLACE BOTH SEAPAINTERS FOR THE BUOYANT APPARATUS.
Condition: Unknown
Due 5 April 1994
Resolved 5 April 1994
Lifesaving
Issued 18 March 1992 Resolved
PROVIDE THREE ADULT TYPE 1 PFD. TOTAL NUMBER OF PASSENGERS REDUCED BY THREE ON ALL ROUTES.
Condition: Unknown
Due 17 June 1992
Resolved 17 June 1992
Lifesaving
Issued 23 March 1990 Resolved
PROVIDE 15 ADULT LIFE PRESERVERS THE TOTAL NUMBER OF PERSON ALLOW IS 51 UNTIL D1 IS COMPLETE.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Engineering
Issued 31 March 1987 Resolved
REFIT THE CHECK VALVES TO THE INDIVIDUAL BILGE SUCTIONS LINES AS REQUIRED BY 46 CFR 182.25-5.
Condition: Unknown
Due 31 March 1987
Resolved 31 March 1987
Construction/Loadline
Issued 1 May 1985 Resolved
PROVIDE FOR MINIMUM RAIL HEIGHT OF 36" AS REQUIRED BY 46 CFR 177.35-1(G). NOTIFY THIS OFFICE OF PROPOSAL. THIS REQUIREMENT IS TO BE COMPLETED NLT 01APR86 TO THE SATISFACTION OF THE ATTENDING CG INSPECTOR.
Condition: Unknown
Due 1 May 1985
Resolved 1 May 1985

Casualty record · 2

30 May 2004Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2084864
14 January 2016Routine · role: Involved in a Marine Casualty · activity 5811345
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

PORGY III (2004). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.