Records from 1985 to 2015. Most recent: inspection, 16 September 2015.
Inspection history · 62
16 September 2015
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5720435
20 October 2014
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5006245
17 December 2010
Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3912658
18 November 2010
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3887160
11 March 2010
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3694240
4 December 2008
Annual Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3372743
19 March 2008
Plan Review "T" Boat
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3172503
6 March 2008
Drydock Extension · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3143516
17 October 2007
COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3076885
25 October 2006
Annual Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2806308
7 December 2005
Examination of Repairs · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2544962
3 November 2005
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2544345
18 October 2005
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2516209
12 September 2005
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2491827
20 June 2005
Plan Review "T" Boat
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2397119
10 November 2004
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2238848
20 October 2004
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2219475
24 March 2004
Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2030622
24 March 2004
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2047724
10 February 2004
Damage Survey · Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2003190
9 February 2004
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2003245
16 October 2003
Annual Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1928338
17 December 2002
Deficiency Check · Examination of Repairs · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1705412
22 October 2002
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1694449
18 April 2002
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1606296
7 December 2001
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1425245
11 October 2001
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1397741
26 October 2000
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1410427
2 October 2000
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 822633
26 July 2000
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 83824
22 October 1999
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1433552
23 October 1998
Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 808823
15 January 1998
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 775423
9 October 1997
Re-Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1111436
7 May 1997
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1098391
27 November 1996
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1093139
22 October 1996
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1442472
4 October 1995
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1380318
2 November 1994
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1356884
18 February 1994
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 853232
3 December 1993
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1359671
3 March 1993
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1149998
8 January 1993
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1366771
20 April 1992
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 944323
31 January 1992
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 946914
31 January 1992
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 946915
6 May 1991
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 917420
5 February 1991
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1224439
29 October 1990
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 912893
20 September 1990
Hull Examination · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 931357
30 July 1990
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 906787
1 July 1990
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1232827
27 March 1990
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1238693
7 February 1990
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 904366
8 March 1989
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 890563
10 February 1989
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1345192
17 March 1988
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1289073
12 February 1988
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1332022
20 April 1987
Deficiency Check · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1026005
17 February 1987
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1329305
18 February 1986
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1295293
15 February 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 978703
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 18 November 2010
Resolved
International / Inland navigation rules of the road expired. Current copy onboard is M16672.2B
Condition: Improper/Lack of Maintenance
Due 18 December 2010
Resolved 17 December 2010
Resolution: Current Nav Rules on board.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 18 November 2010
Resolved
Navigation paper charts not up to date 46 CFR 182.420
Due 18 December 2010
Resolved 17 December 2010
Resolution: Current paper charts are on board
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 November 2010
Resolved
Expired aspirin and eye wash in First Aid Kit 46CFR184.710
Condition: Improper/Lack of Maintenance
Due 18 December 2010
Resolved 17 December 2010
Resolution: Valid aspirin and eye wash is on board.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 18 November 2010
Resolved
Ring Life Buoy (2) not marked with name of vessel 46CFR185.604
Condition: Improper/Lack of Maintenance
Due 18 December 2010
Resolved 17 December 2010
Resolution: Ring bouys are marked with vessel name.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 November 2010
Resolved
Railing on starboard quarter have broken attachment at weld 46CFR177.900
Condition: Damaged By Earlier Event
Due 18 December 2010
Resolved 17 December 2010
Resolution: Railing has been welded and properly repaired.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 November 2010
Resolved
Repair or remove angle iron support bracket on port quarter railing 46CFR177.900
Condition: Damaged By Earlier Event
Due 18 December 2010
Resolved 17 December 2010
Resolution: Angle iron as been removed from port quater railing.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 November 2010
Resolved
Permanently repair railing screen on port bow 46CFR177.900
Condition: Damaged By Earlier Event
Due 18 December 2010
Resolved 17 December 2010
Resolution: Railing screen has been repaired.
Engineering › Bilge Water Management System › Not Operational
Issued 18 November 2010
Resolved
Shaft packing compartment electrical submersible bilge pump warning indicator light in pilot house 46CFR182.520
Condition: Improper/Lack of Maintenance
Due 18 December 2010
Resolved 17 December 2010
Resolution: Bilge pump warning indicator light is operational in pilot house.
Engineering › Bilge Water Management System › Not Operational
Issued 18 November 2010
Resolved
Bilge high level alarm in stern rake/void inoperable 46CFR182.530
Due 18 December 2010
Resolved 17 December 2010
Resolution: Stern rake bilge high level alarm is operational.
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 18 November 2010
Resolved
Permanently attach safety chain to starboard side stern 46CFR177.940
Condition: Damaged By Earlier Event
Due 18 December 2010
Resolved 17 December 2010
Resolution: Safety chain on stbd sten has been permanently attached.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 4 December 2008
Resolved
Provide service report for fixed CO2 and portable extinguishers.
Due 5 December 2008
Resolved 5 December 2008
Resolution: Columbia Fire
Documentation › Logs/Records › Drug Test Records
Issued 4 December 2008
Resolved
Provide proof of drug testing enrollment.
Due 5 December 2008
Resolved 5 December 2008
Resolution: Drug Screens INC
Fire Fighting › Fire Hydrants › Condition
Issued 4 December 2008
Resolved
Make repairs/renew #1 fire station valve.
Due 5 December 2008
Resolved 5 December 2008
Resolution: renewed
Engineering › Bilge Water Management System › Pump
Issued 4 December 2008
Resolved
Repair /renew gasket for Jabsco engine driven bilge pump.
Due 5 December 2008
Resolved 5 December 2008
Engineering › Lubricating Oil Service System › Hose
Issued 4 December 2008
Resolved
Renew defective port engine reduction gear hose (blistered).
Due 10 December 2008
Resolved 9 December 2008
Resolution: renewed
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 27 February 2008
Resolved
Build up Port and Stbd. Shafts to original thickness where worn at packing and support bearings. 46CFR176.670
Due 15 March 2008
Resolved 6 March 2008
Resolution: Shafts repaired at West Coast Propeller in Warrenton, OR.
Construction/Loadline › Hull › Bracket
Issued 27 February 2008
Resolved
Weld under deck support on stbd side where weld is broken.
Due 15 March 2008
Resolved 6 March 2008
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 17 October 2007
Resolved
Provide proof of FCC Safety Radiotelephony Certificate prior to the completion of credit drydock.
Due 15 January 2008
Resolved 8 February 2008
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 October 2007
Resolved
Post all pages of COI, upon receipt prior to the completion of credit drydock.
Due 1 March 2008
Resolved 27 February 2008
Resolution: Corrected
Fire Fighting › Nozzles › Condition
Issued 17 October 2007
Resolved
Renew forward fire hose nozzle (cracked), prior to the completion of credit drydock.
Due 15 January 2008
Resolved 8 February 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 October 2007
Resolved
Prove operation of forward void bilge alarm, prior to the completion of credit drydock.
Due 15 January 2008
Resolved 8 February 2008
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 17 October 2007
Resolved
Renew F/O vent screen with non-corrosive 30 X 30 mesh, prior to the completion of credit drydock.
Due 15 January 2008
Resolved 8 February 2008
Engineering › Bilge Water Management System › Strainer
Issued 17 October 2007
Resolved
Renew shaft compartment installed bilge piping suction strainer, prior to the completion of credit drydock.
Due 15 January 2008
Resolved 8 February 2008
Engineering › Fuel Oil Service System › Hose
Issued 17 October 2007
Resolved
Install chaffing gear on engine hoses as needed, prior to the completion of credit drydock.
Due 1 March 2008
Resolved 27 February 2008
Resolution: Corrected
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 17 October 2007
Resolved
Renew air receiver (tank) gaUge, prior to the completion of credit drydock.
Due 15 January 2008
Resolved 8 February 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 17 October 2007
Resolved
Mount pilot house portable fire extinguisher, prior to the completion of credit drydock.
Due 15 January 2008
Resolved 8 February 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 17 October 2007
Resolved
Install exhaust lagging on port M/E exhaust, prior to the completion of credit drydock.
Due 1 March 2008
Resolved 27 February 2008
Resolution: Corrected
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 25 October 2006
Resolved
Install exhaust lagging on port MDE elbow.
Action required: 705 - Other - as specified
Due 6 November 2006
Resolved 30 October 2006
Resolution: emailed pictures of repair. Satisfactory.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 25 October 2006
Resolved
Provide service report for all portable and fixed fire fighting equipment to include the fire detector in engine room and test remote pulls
Action required: 705 - Other - as specified
Due 1 November 2006
Resolved 30 October 2006
Resolution: Faxed in service report for firefighting equipment on board. Also heat sensor test was completed and found to be in proper working order. Remote pull was checked and working properly.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 1 December 2005
Resolved
Vessel is not to operate carrying passengers or vehicles until engine repairs are completed and inspected to include sea trials to the satisfaction of the attending marine inspector.
Due 23 December 2005
Resolved 7 December 2005
Resolution: Witnessed satisfactory dock and sea trials.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 18 October 2005
Resolved
Throwing of life ring not listed in emergency instructions, update list to reflect the throwing of the life ring. 46 CFR 185.510
Due 18 November 2005
Resolved 3 November 2005
Resolution: Emergency instructions updated to include the throwing of the ring buoy.
Engineering › Lubricating Oil Service System › Hose
Issued 18 October 2005
Resolved
Hydraulic hose on stbd reduction gear has buldge where it meets coupling. Make repairs or replace hose.
Due 18 November 2005
Resolved 3 November 2005
Resolution: Hydraulic hose replaced.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 October 2005
Resolved
Renew globe on light fixture above port engine. 46 CFR 183.430
Due 18 November 2005
Resolved 3 November 2005
Resolution: Globe on light fixture replaced.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 18 October 2005
Resolved
Starting capacitor on oil transfer pump is hanging loose. Mount capacitor to pump.
Due 18 November 2005
Resolved 3 November 2005
Resolution: Starter capacitor hard mounted to pump.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 20 October 2004
Resolved
Provide servicing report for fixed fire system prior to annual anniversary date, to the satisfaction of the attending Coast Guard Marine Inspector. Inspection is not yet due.
Due 20 November 2004
Resolved 10 November 2004
Resolution: Servicing report provided to Coast Guard.
Fire Fighting › Fire Hoses › Connections
Issued 20 October 2004
Resolved
Provide a nozzle for fire station #2 and provide a spanner wrench at station #2. Ref. 46CFR 181.320, to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Unknown
Due 20 November 2004
Resolved 10 November 2004
Resolution: A nozzle and spanner wrench were added to the fire station.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 20 October 2004
Resolved
Renew lenses on portable fire extinguishers located at fire stations 2, 3,& engine spare. Ref: 46CFR 181.320 & NFPA 10, to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Unknown
Due 20 November 2004
Resolved 10 November 2004
Resolution: Copy of fire servicing report provided to Coast Guard indicating replacement of guages on the 3 extinguishers.
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 October 2004
Resolved
Prove proper operation of bilge high level alarm in shaft seal compartment. Ref: 46CFR182.530, to the satisfaction of the attending Coast Guard Marine Inspector. Compartment to be visually checked every four hours during vessel operation until corrected.
Condition: Unknown
Due 20 November 2004
Resolved 10 November 2004
Resolution: Alarm was replaced and proper function has been verified.
Engineering › Fuel Oil Service System › Filter
Issued 24 March 2004
Resolved
Repair MDE that lost propulsion to the satisfaction of US Coast Guard Marine Inspector prior to the carriage of passengers and vehicles.
Condition: Improper/Lack of Maintenance
Due 24 March 2004
Resolved 24 March 2004
Engineering › Steering Gear System
Issued 10 February 2004
Resolved
Provide a repair plan to the attending USCG Marine Inspector for repairs to the vessel steering system. Complete repairs to the satisfaction of the attending USCG Marine Inspector prior to the carriage of passengers or cargo.
Due 12 March 2004
Resolved 25 February 2004
Lifesaving › Lifejacket/PFD (General)
Issued 16 October 2003
Resolved
Renew 09 adult lifejackets to meet the requirements of COI. Reduce passenger count to not more than 69 passengers until total required lifejackets are on board. Item to be completed to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Condition
Due 15 November 2003
Resolved 30 October 2003
Engineering › Lubricating Oil Service System
Issued 22 October 2002
Resolved
Renew wasted engine oil flex hoses on port and starboard engines with SAE J1942 approved hoses and SAE J1475 approved hose fittings. 46CFR182.710 LEGACY COMPONENT DESC: Hose
Due 22 November 2002
Resolved 17 December 2002
Engineering › Fuel Oil Service System
Issued 22 October 2002
Resolved
Replace all non-approved engine oil hoses and diesel fuel return lines with SAE J1942 approved hoses and SAE J1475 hose fittings or fit with manufactures approved flame sleeve to meet SAE J1942 standard. 46CFR182.710 LEGACY COMPONENT DESC: Hose
Due 22 November 2002
Resolved 17 December 2002
Engineering › Lubricating Oil Service System
Issued 22 October 2002
Resolved
Replace plastic oil pressure gauge lines on port/starboard engines and replace with ferrous piping or approved flex hose; or replace with electric unit; or remove altogether. 46CFR182.720 LEGACY COMPONENT DESC: Gauge
Due 22 November 2002
Resolved 17 December 2002
Electrical › Electrical Distribution System (service)
Issued 22 October 2002
Resolved
Properly enclose knife switches at port/starboard engines or replace with enclosed type switches. 46CFR183.05-15(d) LEGACY COMPONENT DESC: Switch
Due 22 November 2002
Resolved 17 December 2002
Electrical › Electrical Distribution System (service)
Issued 22 October 2002
Resolved
Properly enclose electrical solenoids in way of main deck, beneath pilot house, using an NEC approved junction box. LEGACY COMPONENT DESC: Junction Box
Due 22 November 2002
Resolved 17 December 2002
Operations/Management › Passenger Operations
Issued 22 October 2002
Resolved
Ensure passenger count is communicated shore-side prior to getting under way. 46CFR185.504
Due 22 November 2002
Resolved 17 December 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 22 October 2002
Resolved
Provide complete contents of first aid kit per 46CFR160.041 and ensure that products are not expired (eye wash & aspirin) 46CFR184.710 LEGACY COMPONENT DESC: Medicine Chest
Due 22 November 2002
Resolved 17 December 2002
Documentation › Certificates/Documents
Issued 22 October 2002
Resolved
Post or make available vessel's stability letter. 46CFR176.306 LEGACY COMPONENT DESC: Stability Letter
Due 22 November 2002
Resolved 17 December 2002
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 22 October 2002
Resolved
Properly mount/secure BI fire extinguisher in pilot house. LEGACY COMPONENT DESC: Mounting Bracket
Due 22 November 2002
Resolved 17 December 2002
Lifesaving › Lifebuoys
Issued 22 October 2002
Resolved
Provide corrosion proof detachable clip on waterlight for ring life buoy. 46CFR180.70(d)(3) LEGACY COMPONENT DESC: Self-igniting Lights
Due 22 November 2002
Resolved 17 December 2002
Lifesaving › Lifebuoys
Issued 22 October 2002
Resolved
Install new battery in waterlight and label or log installation date. LEGACY COMPONENT DESC: Self-igniting Lights
Due 22 November 2002
Resolved 17 December 2002
Engineering
Issued 7 December 2001
Resolved
Provide permanent repairs to prevent excessive water leakage from starboard shaft packing gland seal. 46 CFR 182.200
Condition: Unknown
Due 3 June 2002
Resolved 17 December 2002
Fire Fighting
Issued 7 December 2001
Resolved
Provide effective means for closing air intakes to engine room space for use when using the fixed CO2 firefighting system. 46 CFR 182.465(h)
Condition: Unknown
Due 7 January 2002
Resolved 16 April 2002
Resolution: Operator fabricated vinyl sleeves to cover engineroom exhaust and intake vents.
Lifesaving
Issued 11 October 2001
Resolved
Legibly re-mark stowage locations for PFDs with type (adult/children) and number of PFDs (46 CFR 185.602)
Condition: Unknown
Due 11 October 2001
Resolved 11 October 2001
Lifesaving
Issued 11 October 2001
Resolved
Renew all worn/damaged PFD donning placards. (46 CFR 185.516)
Condition: Unknown
Due 11 October 2001
Resolved 11 October 2001
Navigation
Issued 11 October 2001
Resolved
Provide an updated chart for waters of vessel's operation. (46 CFR 184.420)
Condition: Unknown
Due 11 October 2001
Resolved 11 October 2001
Navigation
Issued 11 October 2001
Resolved
Paint starboard running light screen flat black per NAVRULES Annex 1.
Condition: Unknown
Due 11 November 2001
Resolved 16 April 2002
Documentation
Issued 11 October 2001
Resolved
Provide proof of valid Radio Safety Telephony certificate. (47 CFR 17)
Condition: Unknown
Due 11 November 2001
Resolved 3 January 2002
Fire Fighting
Issued 11 October 2001
Resolved
Repair port side heat detector guard in engine room. (46 CFR 181.410)
Condition: Unknown
Due 11 October 2001
Resolved 11 October 2001
Lifesaving
Issued 11 October 2001
Resolved
Remove flammable material stowed on board or provide an appropriate stowagelocker. (46 CFR 147)
Condition: Unknown
Due 11 October 2001
Resolved 11 October 2001
Electrical
Issued 11 October 2001
Resolved
Properly label all circuits on starboard side deck distribution box. (46 CFR 183.220)
Condition: Unknown
Due 11 October 2001
Resolved 11 October 2001
Engineering
Issued 11 October 2001
Resolved
Properly label the remote fuel shut-off valves to indicate the purpose of the valve and direction of operation (46 CFR 185.608)
Condition: Unknown
Due 11 October 2001
Resolved 11 October 2001
Navigation
Issued 26 October 2000
Resolved
Provide proof that navigation lights meet UL 1104 standards or replace navigation lights with UL approved lights. 46CFR183.420
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Construction/Loadline
Issued 26 October 2000
Resolved
Provide bilge high-level alarms in all spaces and voids below the main deck. 46CFR182.530.
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Documentation
Issued 26 October 2000
Resolved
Conduct operational test of all machinery and perform man overboard in presence of Coast Guard inspector.
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Engineering
Issued 22 October 1999
Resolved
REPAIR OR REPLACE FUEL VENT BOX WHERE RUSTED THROUGH.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Electrical
Issued 22 October 1999
Resolved
REMOVE UNAPPROVED EXHAUST FAN FROM MACHINERY SPACE, AND SUBMIT PLANS FOR NEW FAN INSTALLATION. INSTALLATION OF FAN MUST BE IN ACCORDANCE WITH [name withheld].
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Construction/Loadline
Issued 22 October 1999
Resolved
PROVIDE PROOF OF PROPER OPERATION OF BILGE PUMP.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Lifesaving
Issued 23 October 1998
Resolved
REPAIR/REPLACE 1 CHILD PFD. STRAP TORN AWAY DURING INSPECTION.
Condition: Unknown
Due 23 October 1998
Resolved 23 October 1998
Fire Fighting
Issued 23 October 1998
Resolved
REMARK VESSEL NAME ON FIRE AXE.
Condition: Unknown
Due 23 October 1998
Resolved 23 October 1998
Construction/Loadline
Issued 23 October 1998
Resolved
INSTALL GUARD AROUND PULLEY FOR WASTE OIL PUMP IN THE MACHINERY SPACE AFT OF STBD. ENGINE.
Condition: Unknown
Due 23 October 1998
Resolved 23 October 1998
Lifesaving
Issued 23 October 1998
Resolved
PROVIDED PROOF THAT ALL VESSEL CREWS ARE CONDUCTING; FIRE AND MAN OVERBOARDDRILLS. PRESENT LOG BOOK SHOWS ONLY ONE CREW COMPLYING WITH REGULATIONS.
Condition: Unknown
Due 23 October 1998
Resolved 23 October 1998
Documentation
Issued 23 October 1998
Resolved
PROVIDE PROOF THAT EMPLOYEES ARE RECEIVING REQUIRED TRAINING IAW THE DRUG TESTING PROGRAM OUTLINED IN 46 CFR 16.
Condition: Unknown
Due 23 October 1998
Resolved 23 October 1998
Lifesaving
Issued 23 October 1998
Resolved
INSTALL GATE IN LOCATION OF RESCUE LADDER AND PLATFORM TO ALLOW ACCESSIBILITY TO RESCUE AREA.
Condition: Unknown
Due 23 October 1998
Resolved 23 October 1998
Documentation
Issued 23 October 1998
Resolved
PROVIDE AND POST ON BOARD THE ORIGINAL CERTIFICATE OF INSPECTION FOR THE VESSEL.
Condition: Unknown
Due 23 October 1998
Resolved 23 October 1998
Engineering
Issued 23 October 1998
Resolved
REMOVE UNAPPROVED EXHAUST FAN FROM MACHINERY SPACE AND INSTALL ONE TO APPROVED PLANS.
Condition: Unknown
Due 23 October 1998
Resolved 23 October 1998
Lifesaving
Issued 23 October 1998
Resolved
REMARK RING BUOY'S WITH VESSEL NAME AND INSTALL 3 TO 6 FOOT LINE WITH DETACHABLE CLIP ON LIGHT AND INSTALL RETROREFLECTIVE TAPE IN 4 LOCATIONS ONEACH BUOY.
Condition: Unknown
Due 23 October 1998
Resolved 23 October 1998
Engineering
Issued 9 October 1997
Resolved
DETERMINE CAUSE OF SHAFT WEAR AND SUBMIT PROPOSAL TO COGNIZANT OCMI NOT LATER THAN 4JAN98, WITH ANY CORRECTIONS TO BE COMPLETED NOT LATER THAN NEXTDRYDOCK OR 4OCT99 WHICH EVER OCCURS FIRST.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Lifesaving
Issued 9 October 1997
Resolved
PROVIDE AN APPROVED FIRST AID KIT OR EQUIVALENT.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Construction/Loadline
Issued 9 October 1997
Resolved
REPAIR/REPLACE AUTOMATIC BILGE PUMP LIGHT IN THE PILOT HOUSE.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Accommodation/Occupational Safety
Issued 9 October 1997
Resolved
PROPERLY MARK EMERGENCY EXIT FOR THE MACHINERY SPACE.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Fire Fighting
Issued 9 October 1997
Resolved
CONDUCT ANNUAL SERVICE OF FIXED FIREFIGHTING SYSTEM IN PRESENCE OF COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Deck/Cargo
Issued 9 October 1997
Resolved
PROVIDE AN ACCEPTABLE ANCHOR AND ASSOCIATED EQUIPMENT TO SATISFACTION COGNIZANT OCMI.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Accommodation/Occupational Safety
Issued 9 October 1997
Resolved
INSTALL ADEQUATE RAILS OR GUARDS AT EACH END OF FERRY.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Unknown
Issued 9 October 1997
Resolved
IMPLEMENT PROCEDURE TO CONDUCT PASSENGER COUNT.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Electrical
Issued 9 October 1997
Resolved
REPLACE ALL NYLON TIES WITH METAL HOLDING STRAPS, REMOVE WIRE FROM BILGES, REPLACE WIRE NUTS WITH CRIMP ON TYPE OR OTHER APPROVED METHOD, REMOVE EXTENSION CORD FROM MACHINERY SPACE.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Electrical
Issued 9 October 1997
Resolved
REPAIR BATTERY BOXES TO ENSURE THEY ARE LIQUID TIGHT, CLEAN BATTERY ACID OFF DECK ON PORT SIDE.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Engineering
Issued 9 October 1997
Resolved
INSTALL GUARDS AROUND ROTATING MACHINERY IE: BOTH MAIN PROPULSION ENGINES.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Accommodation/Occupational Safety
Issued 9 October 1997
Resolved
INSTALL POWER EXHAUST IN THE MACHINERY SPACE. SUBMIT PLANS PRIOR TO INSTALLATION FOR APPROVAL.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Lifesaving
Issued 9 October 1997
Resolved
INSTALL PLATFORM ON RESCUE LADDER TO FACILITATE IN RETRIEVAL OF PERSON OVERBOARD.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Documentation
Issued 9 October 1997
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Unknown
Issued 22 October 1996
Resolved
CONDUCT SATISFACTORY UNDERWAY MAN-OVERBOARD DRILL IN PRESENCE OF USCG MARINE INSPECTOR.
Condition: Unknown
Due 22 October 1996
Resolved 22 October 1996
Unknown
Issued 22 October 1996
Resolved
SUBMIT FOR APPROVAL PLANS FOR FIXED FIRE EXTINGUISHER SYSTEM IN ENGINEROOM.SYSTEM SHALL MEET THE REQUIREMENTS OF 46 CFR 181.400
Condition: Unknown
Due 22 October 1996
Resolved 22 October 1996
Engineering
Issued 4 October 1995
Resolved
INSTALL FLAME SCREENS IN STARBOARD SIDE VENTS 1 AND 2.
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Accommodation/Occupational Safety
Issued 4 October 1995
Resolved
INSTALL ADAQUATE VENTILATION IN LOUNGE AREA.
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Electrical
Issued 4 October 1995
Resolved
INSTALL WATERTIGHT RECEPTICLES ON THE WEATHERDECKS AND THROUGH-OUT THE MACHINERY SPACES.
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Engineering
Issued 4 October 1995
Resolved
REPLACE EXISTING FLEXIBLE FUEL LINE TO BE IN COMPLIANCE WITH 46 CFR 56.50 AND 56.60. PRESENT SYSTEM HAS FLEXIBLE FUEL HOSE COMING FROM THE FUEL TANKRUNNING IN THE BILGE TO THE ENGINE WHICH EXCEEDS 3O INCHES.
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Construction/Loadline
Issued 4 October 1995
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Electrical
Issued 4 October 1995
Resolved
INSTALL WATERTIGHT RECEPTICLE FOR SHORE CONNECTION OR INSTALL A WTERTIGHT BOX FOR THE CONNECTION WHEN NOT IN USE TO PREVENT WATER FROM ENTERING CONNECTION.
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Fire Fighting
Issued 4 October 1995
Resolved
INSTALL FIXED FIREFIGHTING SYSTEM FOR OIL AND PAINT STORAGE AREA OR REMOVE SAME FROM THE VESSEL.
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Documentation
Issued 4 October 1995
Resolved
COMPLETE TEST AS REQUIRED BY LETTER 16711/M/V WAHKIAKUM DATED 04OCT95.
Condition: Unknown
Due 16 October 1995
Resolved 16 October 1995
Construction/Loadline
Issued 4 October 1995
Resolved
MAKE REPAIRS TO BULKHEADS WERE HOLED FOR LOUNGE AREA AND BOTH HEADS.
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Electrical
Issued 2 November 1994
Resolved
Submit electrical plans, including manufacture specifications used for rewiring completed in Jan. 1994. Include length of wire runs, wire gauge, circuit breakers, etc. as installed.
Condition: Unknown
Due 2 November 1994
Resolved 2 November 1994
Accommodation/Occupational Safety
Issued 2 November 1994
Resolved
Provide chain and lock on sewage overboard valve.
Condition: Unknown
Due 2 November 1994
Resolved 2 November 1994
Documentation
Issued 2 November 1994
Resolved
Provide proof of participation in county drug testing program (copy of Wahkiakum County Resolution 33-92) and copy of agreement with medical testing facility. Agreement should list names of all participating crew members.
Condition: Unknown
Due 2 November 1994
Resolved 2 November 1994
Engineering
Issued 2 November 1994
Resolved
Address excessive leaking of shaft packing at next drydock.
Condition: Unknown
Due 2 November 1994
Resolved 2 November 1994
Accommodation/Occupational Safety
Issued 3 December 1993
Resolved
INSTALL ON-OFF SWITCH FOR ENGINE ROOM ELECTRICAL BLOWER IN PILOT HOUSE_x001C_ 46 CFR 111.103-3(a),(b).
Condition: Unknown
Due 3 December 1993
Resolved 3 December 1993
Accommodation/Occupational Safety
Issued 8 January 1993
Resolved
LABEL PFD STORAGE BOXES WITH THE NUMBER OF PFD'S CONTAINED.
Condition: Unknown
Due 8 January 1993
Resolved 8 January 1993
Construction/Loadline
Issued 8 January 1993
Resolved
PROVIDE HOSE ON HAND BILGE PUMP OF SUFFICIENT LENGTH TO DE-WATER ALL BELOW DECK SPACES,
Condition: Unknown
Due 8 January 1993
Resolved 8 January 1993
Fire Fighting
Issued 31 January 1992
Resolved
RENEW FIRE AXE AND STENCIL WITH VESSEL NAME.
Condition: Unknown
Due 31 January 1992
Resolved 31 January 1992
Engineering
Issued 31 January 1992
Resolved
RENEW FUEL VENT FLAMESCREEN WITH 30X30 MESH.
Condition: Unknown
Due 31 January 1992
Resolved 31 January 1992
Electrical
Issued 31 January 1992
Resolved
RENEW WIRING ON ELECTRIC BILGE PUMP, PORT SIDE OF SHAFT ALLEY WITH PERMANENT CRIMPED SPLICING.
Condition: Unknown
Due 31 January 1992
Resolved 31 January 1992
Documentation
Issued 31 January 1992
Resolved
POST OIL POLLUTION PLACARD AT BILGE PUMP CONTROLS AND PILOTHOUSE.
Condition: Unknown
Due 31 January 1992
Resolved 31 January 1992
Documentation
Issued 31 January 1992
Resolved
POST GARBAGE PLAN FOR DISPOSAL OF GARBAGE ASHORE.
Condition: Unknown
Due 31 January 1992
Resolved 31 January 1992
Documentation
Issued 5 February 1991
Resolved
PROVIDE SATISFACTORY EMERGENCY CHECK-OFF LIST._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Lifesaving
Issued 5 February 1991
Resolved
STENCIL RING BUOY WITH VESSEL'S NAME._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Engineering
Issued 5 February 1991
Resolved
PERMANENTLY ATTACH REACH ROD FOR EMERGENCY FUEL SHUT-OFF VALVE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Deck/Cargo
Issued 5 February 1991
Resolved
PROVE SATISFACTORY OPERATION OF SHIPS INSTALLED BILGE SYSTEM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Electrical
Issued 5 February 1991
Resolved
REMOVE UNAUTHORIZED AUTOMATIC TYPE BATTERY CHARGER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Construction/Loadline
Issued 20 September 1990
Resolved
CONDUCT SEA TRIALS TO INCLUDE INSPECTION OF NEW SHAFTS AND SHAFT BEARINGS.
Condition: Unknown
Due 20 September 1990
Resolved 20 September 1990
Navigation
Issued 20 September 1990
Resolved
CONDUCT OPERATIONAL TEST OF STEERING GEAR.
Condition: Unknown
Due 20 September 1990
Resolved 20 September 1990
Engineering
Issued 30 July 1990
Resolved
MAKE PERMANENT REPAIRS TO BENT TAILSHAFTS AND LEAKING BEARINGS IN AFT COMPARTMENT.
Condition: Unknown
Due 30 July 1990
Resolved 30 July 1990
Construction/Loadline
Issued 30 July 1990
Resolved
MAKE VESSEL AVAILABLE AT DRYDOCK FOR COAST GUARD INSPECTION.
Condition: Unknown
Due 30 July 1990
Resolved 30 July 1990
Construction/Loadline
Issued 1 July 1990
Resolved
CROP AND RENEW THE DAMAGED SECTION OF THE BOW AT THE MAIN DECK. ALL PLATE INSERTS MUST BE PROPERLY RADIUSED. NOTIFY THE OFFICER IN CHARGE MARINE INSPECTIONS, PORTLAND, OREGON, WHEN THE PERMANENT REPAIRS HAVE BEEN COMPLETED TO ARRANGE FOR AN INSPECTION.
Condition: Unknown
Due 1 July 1990
Resolved 1 July 1990
Lifesaving
Issued 7 February 1990
Resolved
PROVIDE 50 ADULT AND 4 CHILD LIFE PRESERVERS. THE VESSEL IS RESTRICTED TO NO MORE THAN 28 PERSONS ON BOARD UNTIL CLEARED.
Condition: Unknown
Due 7 February 1990
Resolved 7 February 1990
Lifesaving
Issued 7 February 1990
Resolved
REPLACE GRAB LINE ON THE PORT RING LIFE BUOY.
Condition: Unknown
Due 7 February 1990
Resolved 7 February 1990
Fire Fighting
Issued 10 February 1989
Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 10 February 1989
Resolved 10 February 1989
Unknown
Issued 12 February 1988
Resolved
STENCIL OR POST "NO SMOKING" SIGNS ON PILOT HOUSE AND BACK SIDE OF PASSENGER SPACE/CABIN SO THEY ARE VISIBLE TO PERSONS COMING ON THE VEHICLE DECK.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Lifesaving
Issued 12 February 1988
Resolved
POST "MAN OVERBOARD" PROCEDURES IN AREAS ON DECK THAT AFFORD ALL PASSENGERSAND CREW THE OPPORTUNITY TO BECOME FAMILIAR WITH SAME.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Lifesaving
Issued 12 February 1988
Resolved
POST LIFE JACKET PLACARDS ON OR NEAR STOWAGE AREAS FOR TYPE JACKETS ONBOARD TO SHOW & EXPLAIN DONNING PROCEDURES.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Electrical
Issued 12 February 1988
Resolved
REPLACE THE NON APPROVED LIGHT FIXTURE IN THE WORK ROOM AND THE MISSING FIXTURE IN THE FORWARD PASSENGER SPACE WITH APPROVED MARINE TYPE FIXTURES.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Engineering
Issued 12 February 1988
Resolved
STENCIL DIESEL FUEL TANK VENT.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Lifesaving
Issued 12 February 1988
Resolved
STENCIL LIFE JACKET LOCKERS AND PASSENGER SPACES WITH NUMBER & SIZE OF LIFEJACKETS STOWED IN EACH.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Fire Fighting
Issued 12 February 1988
Resolved
REPLACE NON APPROVED TYPE FIRE NOZZLES WITH APPROVED COMBINATION TYPE.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Accommodation/Occupational Safety
Issued 12 February 1988
Resolved
INSTALL ADDITIONAL CABLE ON BOTH ENDS OF CAR DECK, OF EQUIVALANT STRENGTH AS THE ONE PRESENT AND LOCATE SO THAT THE BOTTOM OF SECOND CABLE IS APPROXIMATELY 12 INCHES OFF THE DECK AT CENTER OF SPAN.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Engineering
Issued 12 February 1988
Resolved
RESTENCIL EMERGENCY FUEL SHUT OFF VALVES.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Lifesaving
Issued 17 February 1987
Resolved
VSL IS LIMITED TO CARRIAGE OF SIX CHILDREN OR SEVENTY-FIVE ADULTS (TOTAL 78PERSONS AT ANYONE TIME) UNTIL ADDITIONAL PFD'S ARE PROVIDED. 8 CHILD AND 78 ADULT PFD'S ARE NEEDED FOR CERTIFICATE OF INSPECTION COMPLIANCE.
Condition: Unknown
Due 17 February 1987
Resolved 17 February 1987
Lifesaving
Issued 17 February 1987
Resolved
RENEW LIFELINES ON RING LIFE BUOYS.
Condition: Unknown
Due 17 February 1987
Resolved 17 February 1987
Fire Fighting
Issued 17 February 1987
Resolved
PROVIDE APPROVED FIRE HOSE NOZZLES.
Condition: Unknown
Due 17 February 1987
Resolved 17 February 1987
Construction/Loadline
Issued 18 February 1986
Resolved
REPLACE BROKEN WINDOW AND MAKE PERMANENT REPAIRS TO THE FRAMES OF ALL SLIDING GLASS WINDOWS IN THE PILOT HOUSE.
Condition: Unknown
Due 18 February 1986
Resolved 18 February 1986
Electrical
Issued 15 February 1985
Resolved
PROVIDE SUITABLE BATTERY TRAYS OF LEAD OR OTHER MATERIAL RESISTANT TO DETERIORATION BY ELECTROLYTIC ACTION FOR ALL INSTALLED BATTERIES NOT SO EQUIPPED.
Condition: Unknown
Due 15 February 1985
Resolved 15 February 1985
Electrical
Issued 15 February 1985
Resolved
REMOVE UNUSED CABLE FROM MSD IN THE NO. 2 COMPARTMENT.
Condition: Unknown
Due 15 February 1985
Resolved 15 February 1985