Records from 1996 to 2004. Most recent: inspection, 5 March 2004.
Inspection history · 38
5 March 2004
Deficiency Check · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2017118
16 February 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2007406
16 February 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2008085
14 February 2004
Administrative Inspection · Ballast Water Examination · Certificate of Compliance
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2006671
21 November 2003
Security Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2000535
7 November 2003
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1945124
14 July 2003
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1845597
1 July 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1831831
6 March 2003
Annual Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1753423
30 January 2003
Administrative Inspection
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1737506
22 July 2002
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1650042
12 February 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1485794
27 November 2001
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 295771
23 March 2001
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 288546
24 October 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 31763
22 September 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 282205
1 August 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 280822
1 August 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1052821
30 May 2000
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 278242
16 April 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 124329
31 March 2000
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 522442
7 March 2000
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 533452
27 November 1999
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 446118
18 September 1999
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 433034
19 January 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 424507
19 January 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 815087
5 October 1998
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 723769
11 July 1998
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 85680
29 June 1998
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 12964
29 June 1998
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 438693
10 February 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 137182
11 October 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 408873
24 June 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 87049
24 June 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 404991
15 February 1997
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 400454
10 August 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 155092
10 August 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 394199
1 July 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 392648
Pollution Prevention/Response › Prevention Equipment
Issued 14 February 2004
Resolved
Vessel's visual overfill alarm on deck does not illuminate when the audible alarm is sounded. Repair prior to next U.S. port. Vessel is allowed a one-time load operation in the port of New Orleans.
LEGACY COMPONENT DESC: Overfill Devices
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 February 2004
Resolved 5 March 2004
Resolution: Tested several tanks while on deck and observed the visual alarm operating properly.
Pollution Prevention/Response › Prevention Equipment
Issued 14 February 2004
Resolved
The No. 1 cargo tank is empty and the overfill alarm is illuminated on the control panel. Repair prior to next U.S. port. Vessel is allowed a one-time load operation in the port of New Orleans.
LEGACY COMPONENT DESC: Overfill Devices
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 February 2004
Resolved 5 March 2004
Resolution: Checked the control panel for the overfill alarms. #1 cargo tank was empty at the time of the inspection and the light was off. Conducted lamp test of the panel and all lights were burning brightly. Mate on deck pulled the overflow for the #1 cargo tan
Operations/Management › Cargo Transfer/Lightering
Issued 14 February 2004
Resolved
The vessel's oil transfer procedures and loading plan do not make reference to crews actions in the event of tank overfill alarm indication. Amend permanently the procedures and loading plan to account for crews actions in the event of an overfill alarm. The vessel made a temp. pen and ink changes. LEGACY COMPONENT DESC: Vessel Transfer Procedures on Hand
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 February 2004
Resolved 5 March 2004
Resolution: Crew actions in the event of an overfill alarm were added to both the loading plan and the Transfer Procedures.
Fire Fighting › Portable Foam Applicators
Issued 14 February 2004
Resolved
All foam applicator housing canisters are corroded to the extent that tools are needed to open the covers. All foam applicator screens are covered with paint chips and corrosion. All canisters are to be made available for immediate use and all foam applicator screens are to be cleaned.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 February 2004
Resolved 5 March 2004
Resolution: Observed 21 foam applicators. Canisters were in the locked position and were readily opened by the [name withheld] all foam applicator screens were cleaned of paint chips and corrosion and were ready for immediate use.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 6 March 2003
Resolved
PRIOR TO NEXT U.S. PORT INSTALL STUDS ON VAPOR LINE FLANGE CONNECTIONS LEGACY COMPONENT DESC: Cargo Manifold
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2003
Navigation › Collision/Grounding Avoidance › Radar
Issued 22 July 2002
Resolved
secondary marine radar inop
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2002
Resolved 24 July 2002
Resolution: vessel provided tech report, proving the secondary marine radar was repaired
Deck/Cargo
Issued 1 August 2000
Resolved
Ensure loadlines are properly marked in accordance with ICLL 66 Annex I Regulation 8.
Condition: Unknown
Due 26 September 2000
Resolved 26 September 2000
Documentation
Issued 1 August 2000
Resolved
Ensure Safety Equipment Certificate properly accounts for total of the vessel's safety equipment, including correct number of required liferafts and oil and chemical carriage endorsements.
Condition: Unknown
Due 26 September 2000
Resolved 26 September 2000
Deck/Cargo
Issued 1 August 2000
Resolved
Ensure all cargo piping is electrically bonded in accordance with IBC Code 10.3.
Condition: Unknown
Due 26 September 2000
Resolved 26 September 2000