Records from 1985 to 2009. Most recent: inspection, 24 April 2009.
Inspection history · 50
24 April 2009
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3459580
3 July 2006
COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2696069
14 April 2006
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2624036
19 July 2005
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2431126
29 July 2004
Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2148020
13 April 2004
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2040100
30 July 2003
MARPOL Annex V Examination · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1860239
25 July 2002
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1650608
22 February 2002
Internal Structural Exam · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1488059
6 September 2001
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 760387
5 September 2001
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 207712
8 August 2001
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 45654
2 August 2001
Damage Survey · Examination of Repairs · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1415691
30 July 2001
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 130976
3 May 2001
MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1428053
18 May 2000
Deficiency Check · Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1433672
5 May 2000
Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1446966
10 March 2000
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1446967
10 May 1999
Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1131455
9 April 1999
Re-Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1455756
22 January 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 787262
4 May 1998
MARPOL Annex V Examination · COI Inspection · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1473482
6 May 1997
MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1097588
15 May 1996
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 879137
5 March 1996
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1080135
26 April 1995
MARPOL Annex V Examination · Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1182742
17 February 1995
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 845180
4 May 1994
Re-Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 869184
29 October 1993
Drydock Extension · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1159823
16 April 1992
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1265114
12 March 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1265663
16 May 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 905776
22 April 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1227706
27 March 1991
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1244442
19 April 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1232137
19 March 1990
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 911438
18 December 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1231366
13 March 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1347526
1 June 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 894485
17 May 1988
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1196868
2 September 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1002141
1 September 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1312593
27 May 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1335416
21 April 1987
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1313046
31 December 1986
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1002556
16 December 1986
Hull Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1335785
25 March 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 997730
11 March 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 993104
13 May 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 983472
21 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 979851
Communications › Alarms/Indicators › Bilge Alarm
Issued 3 July 2006
Resolved
Repair indicator light on engine room bilge alarm.
Condition: Placed in Improper Service
Due 20 July 2006
Resolved 21 July 2006
Resolution: 21JUL06: Received letter of Attestment from O/O stating all requirements have been addressed.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 3 July 2006
Resolved
Replace 4 adult jackets, retro tape 12 adult and 4 child jackets
Condition: Improper/Lack of Maintenance
Due 20 July 2006
Resolved 21 July 2006
Resolution: 21JUL06: Received letter of Attestment from O/O stating all requirements have been addressed.
Lifesaving › Buoyant Apparatus › Painter
Issued 3 July 2006
Resolved
Reconfigure BA lifelines to weaklink.
Condition: Improper Installation
Due 20 July 2006
Resolved 21 July 2006
Resolution: 21JUL06: Received letter of Attestment from O/O stating all requirements have been addressed.
Fire Fighting › Fire Pumps › Pressure
Issued 3 July 2006
Resolved
Repair Fire Pump prior to carrage of more than 49PAX.
Condition: Improper/Lack of Maintenance
Due 20 July 2006
Resolved 21 July 2006
Resolution: 21JUL06: Received letter of Attestment from O/O stating all requirements have been addressed.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 30 June 2006
Resolved
Provide a Light List, Coast Pilot, and USCG Rules of the Road
Condition: Improper/Lack of Maintenance
Due 20 July 2006
Resolved 21 July 2006
Resolution: 21JUL06: Received letter of Attestment from O/O stating all requirements have been addressed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 July 2005
Resolved
Prove proper operation of bilge high level audible alarm (all compartments).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2005
Resolution: Per fax letter fm O/O, ltr scanned into documents for this activity.
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 July 2005
Resolved
Prove proper operation of engineroom bilge high level visual alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2005
Resolution: Per fax letter fm O/O, ltr scanned into documents for this activity.
Lifesaving › Buoyant Apparatus › Painter
Issued 19 July 2005
Resolved
Properly arrange float-free links and painters for buoyant apparatus.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2005
Resolution: Per fax letter fm O/O, ltr scanned into documents for this activity.
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 19 July 2005
Resolved
Provide and apply new retroreflective tape to buoyant apparatus.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2005
Resolution: Per fax letter fm O/O, ltr scanned into documents for this activity.
Lifesaving › Buoyant Apparatus › Marking
Issued 19 July 2005
Resolved
Re-stencil buoyant apparatuses.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2005
Resolution: Per fax letter fm O/O, ltr scanned into documents for this activity.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 19 July 2005
Resolved
Repair port buoyant apparatus waterlight bracket
Due 4 August 2005
Resolved 20 July 2005
Resolution: Per fax letter fm O/O, ltr scanned into documents for this activity.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 19 July 2005
Resolved
Provide 6 adult lifejackets, vessel restricted to 74 total persons weighing >90 lbs. until corrected.
Action required: 705 - Other - as specified
Resolved 6 August 2005
Resolution: Per fax letter fm O/O, ltr scanned into documents for this activity.
Communications › Radio Communications › EPIRB
Issued 19 July 2005
Resolved
Renew EPIRB hydrostatic release, vessel restricted to no more than 3 nautical miles from baseline until corrected.
Action required: 705 - Other - as specified
Resolved 6 August 2005
Resolution: Per fax letter fm O/O, ltr scanned into documents for this activity.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 19 July 2005
Resolved
Replace hose from CO2 fixed fire bottle to hard pipe sections of system, correct by 21 Jul 05.
Due 21 July 2005
Resolved 6 August 2005
Resolution: Per fax letter fm O/O, ltr scanned into documents for this activity.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 19 July 2005
Resolved
Replace heat exchanger for genset.
Due 4 August 2005
Resolved 6 August 2005
Resolution: Per fax letter fm O/O, ltr scanned into documents for this activity.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 19 July 2005
Resolved
Tighten both shaft packings.
Due 4 August 2005
Resolved 6 August 2005
Resolution: Per fax letter fm O/O, ltr scanned into documents for this activity.
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 19 July 2005
Resolved
Replace starboard stern mooring post.
Due 4 August 2005
Resolved 6 August 2005
Resolution: Per fax letter fm O/O, ltr scanned into documents for this activity.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 July 2005
Resolved
Seal all holes in watertight bulkheads.
Due 4 August 2005
Resolved 6 August 2005
Resolution: Per fax letter fm O/O, ltr scanned into documents for this activity.
Construction/Loadline › Structures › Manhole
Issued 19 July 2005
Resolved
Re-atach capture chain for lazarette hatch cover.
Due 4 August 2005
Resolved 6 August 2005
Resolution: Per fax letter fm O/O, ltr scanned into documents for this activity.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 July 2005
Resolved
Ensure all deck lighting has proper fixture, bulb, globe, cage.
Due 4 August 2005
Resolved 6 August 2005
Resolution: Per fax letter fm O/O, ltr scanned into documents for this activity.
Construction/Loadline › Hull › Transverse Frame
Issued 19 July 2005
Resolved
Refasten support (deck) beams in fwd hold outboard port side.
Due 4 August 2005
Resolved 6 August 2005
Resolution: Per fax letter fm O/O, ltr scanned into documents for this activity.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 29 July 2004
Resolved
Provide one adult lifejacket.
Condition: Unknown
Due 30 August 2004
Resolved 16 September 2004
Resolution: Per faxed ltr from O/O, ltr scanned into documents section of vessel details.
Communications › Radio Communications › EPIRB
Issued 29 July 2004
Resolved
Provide new EPIRB hydrostatic release.
Due 30 August 2004
Resolved 16 September 2004
Resolution: On order Per faxed ltr from O/O, ltr scanned into documents section of vessel details.
Documentation › Certificates/Documents
Issued 30 July 2003
Resolved
Post COI
Due 30 August 2003
Resolved 13 August 2003
Documentation › Logs/Records
Issued 30 July 2003
Resolved
Conduct and log radio checks
Due 30 August 2003
Resolved 13 August 2003
Documentation › Manifests/Lists
Issued 30 July 2003
Resolved
Leave passenger count with shore personnel
Due 30 August 2003
Resolved 13 August 2003
Navigation
Issued 30 July 2003
Resolved
Provide copies of light list for transit area
Due 30 August 2003
Resolved 13 April 2004
Electrical › Lighting (service)
Issued 30 July 2003
Resolved
Check stern light, service as needed
Due 30 August 2003
Resolved 13 August 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 30 July 2003
Resolved
Provide ammonia inhalant and eyewash for first aid kit
Due 30 August 2003
Resolved 13 August 2003
Documentation › Markings/Placards
Issued 30 July 2003
Resolved
Provide emergency broadcast placard, post in pilothouse
Due 30 August 2003
Resolved 13 August 2003
Lifesaving
Issued 30 July 2003
Resolved
Register EPIRB with NOAA, re-mark vessel name on EPIRB
Due 30 August 2003
Resolved 13 August 2003
Lifesaving
Issued 30 July 2003
Resolved
Repair 18 lifejackets
Due 30 August 2003
Resolved 13 August 2003
Lifesaving
Issued 30 July 2003
Resolved
Replace one lifejacket
Due 30 August 2003
Resolved 13 August 2003
Lifesaving
Issued 30 July 2003
Resolved
Re-attach painter to starboard buoyant apparatus
Due 30 August 2003
Resolved 13 August 2003
Lifesaving
Issued 30 July 2003
Resolved
Replace grablines on buoyant apparatuses with floating line
Due 30 August 2003
Resolved 13 August 2003
Lifesaving
Issued 30 July 2003
Resolved
Re-stencil vessel name on buoyant apparatuses
Due 30 August 2003
Resolved 13 August 2003
Lifesaving
Issued 30 July 2003
Resolved
Re-arrange painters on buoyant apparatuses with proper float free links
Due 30 August 2003
Resolved 13 August 2003
Lifesaving
Issued 30 July 2003
Resolved
Stecil vessel name on ring buoy, replace old line with floating line
Due 30 August 2003
Resolved 13 August 2003
Electrical
Issued 30 July 2003
Resolved
Repair lazarette bilge pump indicator light
Due 30 August 2003
Resolved 13 August 2003
Navigation
Issued 30 July 2003
Resolved
Install compass light
Due 30 August 2003
Resolved 13 August 2003
Electrical › Electrical Distribution System (service)
Issued 30 July 2003
Resolved
Clean electrical connections under pilothouse operating station
Due 30 August 2003
Resolved 13 August 2003
Documentation › Logs/Records
Issued 30 July 2003
Resolved
Submit fixed fire fighting system inspection record
Due 30 August 2003
Resolved 13 August 2003
Lifesaving › Lifebuoys
Issued 25 July 2002
Resolved
Renew Ring Buoy. LEGACY COMPONENT DESC: Buoyant Lifeline
Due 2 August 2002
Resolved 30 July 2002
Communications › Alarms/Indicators
Issued 25 July 2002
Resolved
Lable bilge alarm lamps. LEGACY COMPONENT DESC: Bilge Alarm
Due 9 August 2002
Resolved 30 July 2002
Lifesaving › Lifejacket/PFD (General)
Issued 25 July 2002
Resolved
Renew retrotape on two child PFDs. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Due 9 August 2002
Resolved 30 July 2002
Operations/Management › Drills/Instruction
Issued 25 July 2002
Resolved
Provide PFD instructions for vest style. LEGACY COMPONENT DESC: Safety Orientation
Condition: Unknown
Due 9 August 2002
Resolved 30 July 2002
Navigation › Piloting/Steering
Issued 25 July 2002
Resolved
Provide a U. S. Coast Pilot. LEGACY COMPONENT DESC: US Coast Pilot
Condition: Unknown
Due 9 August 2002
Resolved 30 July 2002
Electrical
Issued 2 August 2001
Resolved
PROVIDE FOR GROUND DETECTION SYSTEM IN ACCORDANCE WITH 46 CFR 183.324 & 46 CFR 111.05-27.
Condition: Unknown
Due 10 April 2002
Resolved 3 April 2002
Electrical
Issued 2 August 2001
Resolved
PROVIDE A CIRCUIT BREAKER FOR THE SHORE TIE CONNECTION IAW 46 CFR 183.390._x001C_(FOR SAFETY SAKE PLACE BREAKER AS CLOSE AS POSSIBLE TO POWER ENTRY POINT.
Condition: Unknown
Due 10 April 2002
Resolved 3 April 2002
Electrical
Issued 2 August 2001
Resolved
PROVIDE OVER CURRENT PROTECTION FOR THE MAIN FEED FROM THE GENERATOR IAW 46CFR 183.320(f).
Condition: Unknown
Due 10 April 2002
Resolved 3 April 2002
Electrical
Issued 2 August 2001
Resolved
REMOVE AND BLANK UNUSED WIRING FROM OUT OF SERVICE PORT GENERATOR.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Lifesaving
Issued 3 May 2001
Resolved
REPAIR/RENEW 8 ADULT & 5 CHILDREN LIFE JACKETS.
Condition: Unknown
Due 21 June 2001
Resolved 21 June 2001
Construction/Loadline
Issued 3 May 2001
Resolved
NO BILGE HIGH LEVEL ALARM FWD COMPARTMENT. REPAIR/RENEW
Condition: Unknown
Due 21 June 2001
Resolved 21 June 2001
Construction/Loadline
Issued 3 May 2001
Resolved
BILGE VALVE FOR FWD COMPARTMENT FROZEN, COLLISION BLK PENTRATED WITH HOSE.
Condition: Unknown
Due 21 June 2001
Resolved 21 June 2001
Lifesaving
Issued 3 May 2001
Resolved
BA LIGHTS NOT FLOAT FREE. REPAIR/RENEW
Condition: Unknown
Due 21 June 2001
Resolved 21 June 2001
Construction/Loadline
Issued 3 May 2001
Resolved
BILGE DISCHARGE HOSE IN AFTER STEERING LEAKS AT THRU HULL. REPAIR/RENEW.
Condition: Unknown
Due 21 June 2001
Resolved 21 June 2001
Construction/Loadline
Issued 3 May 2001
Resolved
NO BILGE HIGH LEVEL ALARM SHAFT ALLEY. REPAIR/RENEW PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 21 June 2001
Resolved 21 June 2001
Construction/Loadline
Issued 3 May 2001
Resolved
STBD SIDE DECK ROTTEN. REPAIR/RENEW INCLUDING RESEALING ENTIRE DECK.
Condition: Unknown
Due 21 June 2001
Resolved 21 June 2001
Engineering
Issued 3 May 2001
Resolved
STB SHAFT PACKING LEAKS EXCESSICELY. REPAIR/RENEW
Condition: Unknown
Due 21 June 2001
Resolved 21 June 2001
Fire Fighting
Issued 3 May 2001
Resolved
IMPROPER NOZZLE FOR FIRE HOSE. REPAIR/RENEW
Condition: Unknown
Due 21 June 2001
Resolved 21 June 2001
Documentation
Issued 3 May 2001
Resolved
PROVIDE DRUG TESTING INFO.
Condition: Unknown
Due 21 June 2001
Resolved 21 June 2001
Engineering
Issued 3 May 2001
Resolved
FUEL SOUNDING PIPE HOSE CONNECTION LEAKS. REPAIR/RENEW
Condition: Unknown
Due 21 June 2001
Resolved 21 June 2001
Lifesaving
Issued 3 May 2001
Resolved
PROVIDE CREW FOR UNDERWAY INSPECTION AND CREW DRILLS.
Condition: Unknown
Due 21 June 2001
Resolved 21 June 2001
Navigation
Issued 3 May 2001
Resolved
NO CHARTS, TIDE & CURRENT TABLES ON BOARD. PLACE ON BOARD PRIOR TO CARRYINGPASSENGERS.
Condition: Unknown
Due 21 June 2001
Resolved 21 June 2001
Lifesaving
Issued 3 May 2001
Resolved
EPIRB NOT REGISTERED.
Condition: Unknown
Due 21 June 2001
Resolved 21 June 2001
Fire Fighting
Issued 3 May 2001
Resolved
FIRE FIGHTING EQUIPMENT NOT SERVICED. HAVE ALL FIRE FIGHTING EQUIPMENT SERVICED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 21 June 2001
Resolved 21 June 2001
Engineering
Issued 3 May 2001
Resolved
FUEL VALVE STBD SIDE AT TANK FROZEN. REPAIR/RENEW PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 21 June 2001
Resolved 21 June 2001
Construction/Loadline
Issued 18 May 2000
Resolved
PROVE OPERATION OF BILGE HIGH WATER ALARM.
Condition: Unknown
Due 26 May 2000
Resolved 12 June 2000
Fire Fighting
Issued 18 May 2000
Resolved
RECHARGE ONE B-II PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 26 May 2000
Resolved 12 June 2000
Fire Fighting
Issued 10 May 1999
Resolved
CONDUCT INSTALLATION INSPECTION AND TEST OF FIXED CO2/FIRE DETECTION SYSTEM/PIPING.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Documentation
Issued 9 April 1999
Resolved
COME INTO COMLPIANCE WITH USCG DRUG TESTING REGULATIONS.
Condition: Unknown
Due 28 April 1999
Resolved 27 August 1999
Electrical
Issued 9 April 1999
Resolved
RENEW PROTECTIVE LIGHT COVERS FOR OUTDOOR LIGHTS, FWD AND STBD SIDE FWD.
Condition: Unknown
Due 28 April 1999
Resolved 27 August 1999
Accommodation/Occupational Safety
Issued 9 April 1999
Resolved
REPAIR BROKEN RAIL, MAIN DECK, PORT SIDE AFT.
Condition: Unknown
Due 28 April 1999
Resolved 27 August 1999
Construction/Loadline
Issued 9 April 1999
Resolved
INSTALL BILGE ALARMS, ALL CMPTS.
Condition: Unknown
Due 28 April 1999
Resolved 27 August 1999
Documentation
Issued 4 May 1998
Resolved
SHOW PROOF OF LOGGED TRAINING AND DRILLS.
Condition: Unknown
Due 11 May 1998
Resolved 26 June 1998
Lifesaving
Issued 4 May 1998
Resolved
PROVIDE AND INSTALL FLOAT FREE LINK AND LINE SERVING B/A's. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 11 May 1998
Resolved 26 June 1998
Documentation
Issued 4 May 1998
Resolved
SHOW PROOF OF COMPLIANCE W/ CG DRUG TESTING REGS.
Condition: Unknown
Due 11 May 1998
Resolved 26 June 1998
Lifesaving
Issued 4 May 1998
Resolved
SECURE MICROWAVE OVEN IN GALLEY.
Condition: Unknown
Due 11 May 1998
Resolved 26 June 1998
Lifesaving
Issued 4 May 1998
Resolved
RENEW RAILING, PORTSIDE WHERE BENT.
Condition: Unknown
Due 11 May 1998
Resolved 26 June 1998
Construction/Loadline
Issued 4 May 1998
Resolved
STOP ROT AROUND HATCH INTO LAZ.
Condition: Unknown
Due 11 May 1998
Resolved 26 June 1998
Lifesaving
Issued 4 May 1998
Resolved
PROVE PROPER OPERATION OF WATER LIGHT SERVING RING BUOY. NO NIGHT OPERATION UNTIL CLEARED.
Condition: Unknown
Due 11 May 1998
Resolved 26 June 1998
Electrical
Issued 4 May 1998
Resolved
LABEL ALL BREAKERS THOUGHOUT VESSEL.
Condition: Unknown
Due 11 May 1998
Resolved 26 June 1998
Electrical
Issued 4 May 1998
Resolved
REROUTE WIRING SERVING ELECTRIC FIRE/WASHDOWN PUMP.
Condition: Unknown
Due 11 May 1998
Resolved 26 June 1998
Engineering
Issued 4 May 1998
Resolved
PROPERLY INSTALL FLAME IMPINGMENT BOWL ON FUEL FILTER SERVING STBD MDE.
Condition: Unknown
Due 11 May 1998
Resolved 26 June 1998
Lifesaving
Issued 6 May 1997
Resolved
RENEW ALL RETROREFLECTIVE TAPE ON ALL HORSE COLLAR TYPE PFD's.
Condition: Unknown
Due 13 May 1997
Resolved 30 May 1997
Documentation
Issued 6 May 1997
Resolved
PROVIDE A GARBAGE RECORD BOOK.
Condition: Unknown
Due 13 May 1997
Resolved 30 May 1997
Documentation
Issued 6 May 1997
Resolved
LOG ALL DRILLS AND TRAINING.
Condition: Unknown
Due 13 May 1997
Resolved 30 May 1997
Lifesaving
Issued 6 May 1997
Resolved
PROVIDE NEW BRIGHTLY COLORED CONTAINER FOR FLARES AND LABEL IT "DISTRESS SIGNALS."
Condition: Unknown
Due 13 May 1997
Resolved 30 May 1997
Lifesaving
Issued 6 May 1997
Resolved
PROVIDE 6 NEW RED AND 6 NEW ORANGE FLARES.
Condition: Unknown
Due 13 May 1997
Resolved 30 May 1997
Lifesaving
Issued 6 May 1997
Resolved
RENEW/REPAIR LIFE RING. NO PASSENGERS FOR HIRE UNTIL CORRECTED.
Condition: Unknown
Due 13 May 1997
Resolved 30 May 1997
Fire Fighting
Issued 6 May 1997
Resolved
PROVE 6 YEAR SERVICING OF THE 1 B-I AND THE 2 B-II's THAT REQUIRE SERVICING.
Condition: Unknown
Due 13 May 1997
Resolved 30 May 1997
Lifesaving
Issued 6 May 1997
Resolved
PROVIDE EMERGENCY BROADCAST PLACARD AND MOUNT NEAR RADIO TRANSMITTING EQUIPMENT.
Condition: Unknown
Due 13 May 1997
Resolved 30 May 1997
Documentation
Issued 29 October 1993
Resolved
DRYDOCK VESSEL FOR EXAMINATION NOT LATER THAN 31DEC93. A (2) TWO MONTH EXTENTION OF THE DRYDOCK INTERNAL HAS BEEN GRANTED EFFECTIVE 31OCT93.
Condition: Unknown
Due 29 October 1993
Resolved 29 October 1993
Electrical
Issued 12 March 1992
Resolved
PUT BLANKS IN ELECTRICAL PANEL IN PILOT HOUSE STARBOARD SIDE TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Construction/Loadline
Issued 12 March 1992
Resolved
RECAULK LEAKS IWO FRAMES 1,2 & 3 STBD SIDE OF BOW TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 27 April 1992
Resolved 27 April 1992
Construction/Loadline
Issued 16 May 1991
Resolved
MAKE PENETRATIONS AT COLLISION BULKHEAD WATERTIGHT. (PENETRATIONS LOCATED BELOW MAIN DECK).
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Lifesaving
Issued 27 March 1991
Resolved
PROVIDE 13 LIFE JACKETS USCG APPROVED. CARRYING OF PASSENGERS IS RESTRICTEDTO 67 UNTIL THE 13 LIFE JACKETS ARE ABOARD THE VESSEL.
Condition: Unknown
Due 27 March 1991
Resolved 27 March 1991
Documentation
Issued 19 March 1990
Resolved
PROVIDE CURRENT TIDES AND CURRENT TABLES FOR VSL.
Condition: Unknown
Due 19 March 1990
Resolved 19 March 1990
Lifesaving
Issued 21 April 1987
Resolved
RENEW LINE ON RING BUOY.
Condition: Unknown
Due 21 April 1987
Resolved 21 April 1987
Engineering
Issued 21 April 1987
Resolved
PROVIDE DRIP SHIELD FOR RACOR FUEL FILTER ON NO. 2 MAIN DIESEL ENGINE.
Condition: Unknown
Due 21 April 1987
Resolved 21 April 1987
Engineering
Issued 21 April 1987
Resolved
INSTALL REACH ROD ON BILGE SUCTION VALVE LOCKER IN BOW COMPARTMENT.
Condition: Unknown
Due 21 April 1987
Resolved 21 April 1987
Engineering
Issued 16 December 1986
Resolved
REPAIR OR REPLACE HANDLE ON STARBOARD EMERGENCY FUEL SHUT-OFF VALVE, AND PROVE OPERATION OF SAME.
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Engineering
Issued 16 December 1986
Resolved
REPLACE 4 NON-COAST GUARD APPROVED FLEX FUEL LINES ON MAIN DIESEL ENGINES, 2 EACH WITH COAST GUARD APPROVED.
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Electrical
Issued 16 December 1986
Resolved
PROVIDE 2 STOP VALVES ON AUXILIARY GENERATOR EXHAUST PORT AND STARBOARD, WHERE MISSING THROUGH HULL 6" ABOVE WATER LINE.
Condition: Unknown
Due 16 December 1986
Resolved 16 December 1986
Accommodation/Occupational Safety
Issued 11 March 1986
Resolved
PROVIDE OPERATIONAL TEST OF 2 WASH BASINS PRESENTLY OUT OF COMMISSION.
Condition: Unknown
Due 11 March 1986
Resolved 11 March 1986
Accommodation/Occupational Safety
Issued 11 March 1986
Resolved
PROVIDE OPERATIONAL TEST OF MEN'S TOILET, PRESENTLY OUT OF COMMISSION.
Condition: Unknown
Due 11 March 1986
Resolved 11 March 1986
Electrical
Issued 11 March 1986
Resolved
PROVIDE OPRATIONAL TEST OF SIGNAL STRENGTH INDICATOR PRESENTLY OUT OF COMMISSION.
Condition: Unknown
Due 11 March 1986
Resolved 11 March 1986
Engineering
Issued 11 March 1986
Resolved
LABEL OR STENCIL EMERGENCY FUEL SHUT-OFF'S WHERE MISSING.
Condition: Unknown
Due 11 March 1986
Resolved 11 March 1986
Electrical
Issued 11 March 1986
Resolved
PROVIDE OPERATIONAL TEST OF STBD AUX. GEN. UNDER LOAD PERSENTLY OUT OF COMMISSION.
Condition: Unknown
Due 11 March 1986
Resolved 11 March 1986
Deck/Cargo
Issued 11 March 1986
Resolved
LABEL OR STENCIL BILGE MANIFOLD TO INDICATE LOCATION OF VALVES.
Condition: Unknown
Due 11 March 1986
Resolved 11 March 1986
Fire Fighting
Issued 11 March 1986
Resolved
PROVIDE OPERATIONAL TEST OF BELT DRIVE FIRE/BILGE PUMP PRESENTLY OUT OF COMMISSION.
Condition: Unknown
Due 11 March 1986
Resolved 11 March 1986
Lifesaving
Issued 11 March 1986
Resolved
REPLACE OR REPAIR 10 ADULT AND 1 CHILD PFD'S WHERE TORN OR STRAPS MISSING.
Condition: Unknown
Due 11 March 1986
Resolved 11 March 1986
Accommodation/Occupational Safety
Issued 11 March 1986
Resolved
PROVIDE LOW VENTS TO FOLLOWING COMPARTMENTS #2,3,4 AND 5 WHERE MISSING.
Condition: Unknown
Due 11 March 1986
Resolved 11 March 1986