Records from 1985 to 2016. Most recent: inspection, 7 March 2016.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 47
7 March 2016
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5828270
26 June 2008
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3248303
16 May 2007
Annual Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2932239
7 June 2006
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2672570
14 June 2005
Annual Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2388972
18 May 2004
Periodic Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2090993
28 May 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1811207
25 June 2002
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1636034
9 May 2002
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1614598
7 December 2001
Administrative Inspection
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1075997
17 May 2001
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1064200
30 June 2000
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1379270
22 June 2000
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 819085
21 June 1999
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1191135
28 April 1999
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 791589
25 August 1998
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1132093
13 May 1998
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 794360
13 May 1998
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 796331
13 May 1998
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1132094
23 June 1997
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 777844
21 May 1997
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1104993
7 June 1996
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 881360
6 July 1995
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1188433
8 June 1995
Plan Review "T" Boat · COI Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1390052
7 November 1994
Drydock Extension
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1177609
11 August 1994
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1181827
1 August 1994
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 870032
31 May 1994
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 864071
9 May 1994
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1168329
26 May 1993
Re-Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1373862
6 April 1993
Plan Review "T" Boat
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1148425
11 May 1992
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 953981
22 April 1991
Hull Examination · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1238572
7 May 1990
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1236583
12 May 1989
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1034437
12 May 1989
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1041581
27 April 1988
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1343475
23 September 1987
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1008493
8 July 1987
Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1029635
1 June 1987
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1310085
24 April 1987
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1018495
21 August 1986
Examination of Repairs
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 989712
9 June 1986
Deficiency Check · COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1301837
9 May 1986
Examination of Repairs · Credit Drydock
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 994239
3 December 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1293100
3 May 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 979557
19 April 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1285832
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 26 June 2008
Resolved
Provide drip bowl beneath fuel filter prior to July 3, 2008.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 July 2008
Resolved 28 July 2008
Resolution: Verified installation of bowl.
Fire Fighting › Combustible Materials › Grounds
Issued 26 June 2008
Resolved
O/O repaired port side fuel tank ground on the spot.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 26 June 2008
Resolution: Verfied repairs.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 26 June 2008
Resolved
Proper operation of foxed fire fighting system prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2008
Resolution: Received certificate from servicing company attesting to test switch operations.
Stability › Watertight Integrity › General
Issued 16 May 2007
Resolved
Replace lazarette compartment deck hatch cover gasket prior to 31 May 07.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 31 May 2007
Resolution: Gasket replaced.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 May 2007
Resolved
Replace expired aspirin prior to 31 May 07.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 31 May 2007
Resolution: Expired aspirin removed from vessel and replaced.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 16 May 2007
Resolved
Properly secure line for waterlight around BA or thru clip prior to 31 May 07.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 31 May 2007
Resolution: Waterlight attached appropriately.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 May 2007
Resolved
Remove or properly label/cap off (not connected to power source) dead end wire in head and flying bridge prior to 31 May 07.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 31 May 2007
Resolution: Dead ended wires were removed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 May 2007
Resolved
Install chain or rail course across both open sections (approx 2' wide) on aft fishing deck, port and starboard, to ensure 36" minimum height requirement is met. Owner to submit proposal prior to installation.
Action required: 705 - Other - as specified
Due 18 June 2007
Resolved 31 May 2007
Resolution: O/O installed removable chain w/ clip to temporarily raise rails on both port and stbd waists IWO mooring stanchion, All SAT.
Construction/Loadline
Issued 2 June 2004
Resolved
Sand/Seal areas on hull identified by MI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2004
Resolved 8 June 2004
Resolution: Inspected sat.
Engineering
Issued 18 May 2004
Resolved
Remove prop and make key way available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2004
Resolved 8 June 2004
Resolution: Inspected sat.
Construction/Loadline
Issued 18 May 2004
Resolved
Replace aft section of worm shoe.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2004
Resolved 8 June 2004
Resolution: Replaced and inspected sat.
Navigation
Issued 17 May 2004
Resolved
Vessel restricted to no greater than 3 NM due to inop radar.
Due 17 May 2004
Resolved 2 June 2004
Resolution: O/O installed new radar. Test sat.
Lifesaving
Issued 17 May 2004
Resolved
Replace all lines on BA
Due 18 June 2004
Resolved 2 June 2004
Resolution: Replaced all lines on BA. Inspected sat.
Deck/Cargo
Issued 17 May 2004
Resolved
Install lanyards on all exterior hatches.
Due 18 June 2004
Resolved 2 June 2004
Resolution: Installed lanyards on all exterior hatches. Inspected sat.
Documentation › Certificates/Documents
Issued 28 May 2003
Resolved
Provide/Renew Safety Cerificate
Due 27 June 2003
Resolved 5 June 2003
Resolution: Provided new Safety Certificat.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 28 May 2003
Resolved
Label # of adult/children life jackets on stowage locker.
Due 27 June 2003
Resolved 5 June 2003
Resolution: Labeled life jacket stowage locker.
Navigation › Piloting/Steering
Issued 9 May 2002
Resolved
Provide proper Coast Pilot Vol 3 and Light List Vol II. LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Unknown
Due 30 June 2002
Resolved 24 June 2002
Resolution: Purchased new Coast Pilot Vol. 3 and Light List Vol. II.
Navigation › Piloting/Steering
Issued 9 May 2002
Resolved
Update marine chart 12326 LEGACY COMPONENT DESC: Marine Charts
Condition: Improper/Lack of Maintenance
Due 30 June 2002
Resolved 24 June 2002
Resolution: New chart 12326 purchased.
Accommodation/Occupational Safety › Medical/First Aid
Issued 9 May 2002
Resolved
Provide iodine, eye wash, aspirins and ammonia inhalants for first-aid kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 30 June 2002
Resolved 24 June 2002
Resolution: Replaced first-aid kit with new one.
Construction/Loadline › Penetrations
Issued 9 May 2002
Resolved
Replace hose on washdown thru hull. LEGACY COMPONENT DESC: Bottom Plug
Condition: Unknown
Due 30 June 2002
Resolved 24 June 2002
Resolution: Hoses replaced on wash down.
Lifesaving › Buoyant Apparatus
Issued 9 May 2002
Resolved
Replace all lines on boyant apparatus and water light. LEGACY COMPONENT DESC: Line
Condition: Placed in Improper Service
Due 30 June 2002
Resolved 24 June 2002
Resolution: Lines on boyant aparatus and water light replaced .
Construction/Loadline › Penetrations
Issued 9 May 2002
Resolved
Seal #2 aft compartment bulkhead penatrations. LEGACY COMPONENT DESC: Gasket
Condition: Improper/Lack of Maintenance
Due 30 June 2002
Resolved 24 June 2002
Resolution: Aft (#2) compartment bulkhead properly sealed.
Operations/Management › Drills/Instruction
Issued 9 May 2002
Resolved
Update training log for June. LEGACY COMPONENT DESC: Logs
Condition: Unknown
Due 30 June 2002
Resolved 24 June 2002
Resolution: Provided properly updated training log.
Lifesaving
Issued 22 June 2000
Resolved
PROVIDE BREAKING STRENGTH TAB ON WEAK LINK FOR BUOYANT APPARATUS.
Condition: Unknown
Due 15 July 2000
Resolved 5 July 2000
Lifesaving
Issued 22 June 2000
Resolved
REPLACE STRAPS ON 32 ADULT AND 4 CHILD LIFE PRESERVERS.
Condition: Unknown
Due 22 June 2000
Resolved 5 July 2000
Lifesaving
Issued 22 June 2000
Resolved
PROVIDE (6) ORANGE HAND FLARES.
Condition: Unknown
Due 22 June 2000
Resolved 5 July 2000
Engineering
Issued 21 June 1999
Resolved
REPLACE WORN TAILSHAFT BEARINGS.
Condition: Unknown
Due 21 July 1999
Resolved 25 June 1999
Accommodation/Occupational Safety
Issued 21 June 1999
Resolved
REPLACE 2 1/2 INCH GATE VALVE FOR OVERBOARD SEWAGE DISCHARGE.
Condition: Unknown
Due 21 July 1999
Resolved 25 June 1999
Construction/Loadline
Issued 21 June 1999
Resolved
REPAIR HOLE IN PLANK BELOW WATERLINE, PORT SIDE, COMPT #3, SECOND BAY AFT OF FORWARD BULKHEAD.
Condition: Unknown
Due 21 July 1999
Resolved 25 June 1999
Fire Fighting
Issued 21 May 1997
Resolved
BEGIN PORTABLE FIREX SERVICING OF ALL EXTINGUISHERS IAW NFPA 10. _x001C_ BOTH ANNUAL AND MONTHLY SERVICING.
Condition: Unknown
Due 30 June 1997
Resolved 1 July 1997
Lifesaving
Issued 21 May 1997
Resolved
REPLACE RETRO MATERIAL ON AT LEAST 32 PFD'S AS PER 46 CFR 160.077-13._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 June 1997
Resolved 1 July 1997
Construction/Loadline
Issued 8 June 1995
Resolved
PROVIDE MAIN DECK DRAINAGE REQUIRED BY TABLE 46 CFR 171.150 (820 SQUARE INCHES), OR EVIDENCE OF WRITTEN USCG ACCEPTANCE OF 54 SQ IN EXISTING SINCE 1962 DELIVERY. [OCMI WILL CONSIDER OWNER'S POSITION ON THIS MATTER, PREFERABLY BASED ON STABILITY TEST RESULTS (PER MEETING WITH CID 15JUN95.)]
Condition: Unknown
Due 8 June 1995
Resolved 8 June 1995
Construction/Loadline
Issued 7 November 1994
Resolved
PRIOR TO CARRYING PASSENGERS AFTER 30 NOVEMBER 1994, COMPLETE A CREDIT DRYDOCK EXAMINATION TO THE SATISFACTION ON AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 7 November 1994
Resolved 7 November 1994
Electrical
Issued 31 May 1994
Resolved
PRIOR TO PLACING AUXILIARY GENERATOR IN SERVICE WITH PASSENGERS ON BOARD, COMPLETE REQUIREMENTS OF [name withheld] LETTER DATED _x001C_ 02 SEPTEMBER 1993.
Condition: Unknown
Due 31 May 1994
Resolved 31 May 1994
Construction/Loadline
Issued 9 May 1994
Resolved
PRIOR TO CARRYING PASSENGERS, CORRECT THE SOURCE OF LEAKING IN THE FIRST AND SECOND BAYS NEAR THE FORWARD END OF THE SHAFT LOG ON THE PORT SIDE.
Condition: Unknown
Due 9 May 1994
Resolved 9 May 1994
Construction/Loadline
Issued 9 May 1994
Resolved
PRIOR TO CARRYING PASSENGERS, CORRECT THE SOURCE OF LEAKING FORWARD OF THE COLLISION BULKHEAD ON THE PORT SIDE, FOUR FRAMES UP FROM THE KEEL IN THE SECOND BAY.
Condition: Unknown
Due 9 May 1994
Resolved 9 May 1994
Construction/Loadline
Issued 9 May 1994
Resolved
PRIOR TO CARRYING PASSENGERS, CORRECT THE SOURCE OF LEAKING FORWARD OF THE COLLISION BULKHEAD ON THE STARBOARD SIDE OF THE STEM.
Condition: Unknown
Due 9 May 1994
Resolved 9 May 1994
Lifesaving
Issued 9 May 1994
Resolved
PRIOR TO CARRYING PASSENGERS, CONDUCT UNDERWAY EMERGENCY DRILLS AND MAKE ALL COMPARTMENTS ACCESSIBLE TO THE SATISFACTION OF AN ATTENDING USCG MARINEINSPECTOR.
Condition: Unknown
Due 9 May 1994
Resolved 9 May 1994
Construction/Loadline
Issued 9 May 1994
Resolved
PRIOR TO CARRYING PASSENGERS, CORRECT THE SOURCE OF LEAKING IN THE SECOND AND THIRD BAYS FORWARD OF THE STARBOARD RUDDER POST.
Condition: Unknown
Due 9 May 1994
Resolved 9 May 1994
Documentation
Issued 11 May 1992
Resolved
NO PASSENGERS ARE PERMITTED UNTIL VESSEL HAS RECEIVED ANNUAL DOCUMENTATION STICKER.
Condition: Unknown
Due 23 June 1992
Resolved 23 June 1992
Navigation
Issued 7 May 1990
Resolved
PROVIDE A COPY OF THE RULES OF THE ROAD.
Condition: Unknown
Due 7 May 1990
Resolved 7 May 1990
Engineering
Issued 7 May 1990
Resolved
PROVIDE AN ALARM ON THE EXHAUST COOLING WATER.
Condition: Unknown
Due 7 May 1990
Resolved 7 May 1990
Fire Fighting
Issued 7 May 1990
Resolved
HYDRO TEST ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 7 May 1990
Resolved 7 May 1990
Lifesaving
Issued 7 May 1990
Resolved
RENEW THE BUOYANT APPARATUS PENDANTS.
Condition: Unknown
Due 7 May 1990
Resolved 7 May 1990
Unknown
Issued 24 April 1987
Resolved
PROVE SATISFACTORY OPERATION OF THE BILGE PUMPING SYSTEM.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987
Construction/Loadline
Issued 24 April 1987
Resolved
DOUBLE CLAMP AS NECESSARY ALL BELOW THE WATER LINE FLEXIBLE HOSE FITTINGS THAT ARE IN LINE WITH SEA VALVES.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987
Unknown
Issued 24 April 1987
Resolved
RENEW EXHAUST COOLING SEA WATER SUCTION VALVE. VALVE LEAKS WHEN IN THE OPEN POSITION.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987
Construction/Loadline
Issued 9 June 1986
Resolved
MAKE VESSEL AVAILABLE FOR UNDERWAY CHECK OF REPAIRS.
Condition: Unknown
Due 9 June 1986
Resolved 9 June 1986
Construction/Loadline
Issued 19 April 1985
Resolved
RAISE SAFETY RAIL HEIGHT TO MINIMUM OF 36 INCHES AS REQUIRED BY 46 CFR 177.35-1(G).
Condition: Unknown
Due 19 April 1985
Resolved 19 April 1985
Documentation
Issued 19 April 1985
Resolved
OBTAIN VALID RADIO SAFETY CERTIFICATE FROM FCC PRIOR TO CARRYING PASSENGERS. PROVIDE COPY OF CERTIFICATE TO [name withheld].
Condition: Unknown
Due 19 April 1985
Resolved 19 April 1985