Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)58.1 ft × 21.0 ft × 5.2 ft
Registered tonnagegross 53 / net 36
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDITTMAR & DONALDSON · COSTA MESA, CA, UNITED STATES · built 1962
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN CLEMENTE, CA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 11 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it53 - Regulatory (Subpart C or D), Gross Ton 36 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 30 inspections, each with its date, unit and type; 15 deficiencies with the resolution recorded against each; 1 operational control with no removal date recorded; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 30
12 May 2025Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8096309
25 November 2024Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8015816
13 November 2024In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8031090
7 May 2024Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7877521
5 April 2024In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7893714
12 March 2024In-Service Inspection · Special Consideration
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7877883
11 December 2023Administrative Inspection · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7834203
10 October 2023In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7795440
24 April 2023Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7622744
24 April 2023In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7654651
4 April 2023Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7663786
28 February 2023Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7643217
1 February 2023Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7630583
15 December 2022Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7609519
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 December 2022Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Interconnected fire detection system not installed.
Vessel route is restricted to Limited Coastwise, and vessel is restricted from carrying passengers in overnight accommodations until interconnected fire detection system is installed and witnessed by the attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2023
Resolved 23 February 2023
Resolution: Plans submitted and satisfactory test of FD and Bridge watch alerter system.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 March 2022Resolved
An adult life jacket must be provided for each person carried onbard a vessel. Marine inspector condemned two lifejackets. Owner/Operator corrected on the spot.
46 CFR 180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 22 March 2022
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 November 2021Resolved
All griddles, broilers, and deep fat fryers must be fitted with a grease extraction hood in compliance with § 181.425.
(a)A grease extraction hood required by 46 CFR 181.400 must meet UL 710, or other standard specified by the Commandant.
(b)A grease extraction hood must be equipped with a dry or wet chemical fire extinguishing system meeting the applicable sections of NFPA 17 or NFPA 17A, or other standard specified by the Commandant, and must be listed by an independent laboratory recognized by the Commandant.
Submit plans to install approved extraction/suppression system for galley range. Install an additional 40-B:C fire extinguisher in vicinity of griddle.
Vessel PAX reduced to 49, or the griddle is removed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 November 2021
Resolved 5 April 2024
Resolution: Owner installed a fire fighting wet chemical extinguishing system on board.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 12 February 2021Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material, display and distribution of community-service hot-line telephone number for crew-member assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Vessel did not have EAP information displayed in a conspicuous location. Vessel to display EAP information.
46 CFR 16.401
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 March 2021
Resolved 8 March 2021
Resolution: Vessel provided satisfactory evidence of posting the EAP information.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 February 2021Resolved
Each battery must be free from exposure. MI discovered battery box under helm to not be protected with a lid. Vessel to provide battery box with an adequate lid.
46 CFR 183.350
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 March 2021
Resolved 8 March 2021
Resolution: Vessel provided satisfactory evidence of installing a cover on the battery underneath the helm.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 12 February 2021Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling and not used as a means of support. MI discovered series of wires and cables being supported by plastic tie wraps in engine room. Vessel to properly secure all wires and cables.
46 CFR 183.340
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 March 2021
Resolved 8 March 2021
Resolution: Vessel provided satisfactory evidence of installing metal supports for cable and wiring in the engine room.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 12 February 2021Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Vessel did not have up-to-date charts. Vessel to provide up-to-date charts and local Notice to Mariners updates.
46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 March 2021
Resolved 8 March 2021
Resolution: Vessel provided satisfactory evidence of obtaining an up-to-date chart onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 12 February 2021Resolved
A cooking appliance must be installed to prevent movement in heavy seas. MI discovered coffee maker to be not safely secured. Vessel to provide coffee maker with an adequate bracket to prevent tilting/falling.
46 CFR 184.220
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 March 2021
Resolved 8 March 2021
Resolution: Vessel provided satisfactory evidence of installing a bracket on the coffee maker.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 October 2019Resolved
All mattresses must comply with either: The U.S. Department of Commerce Standard for mattress flammability 16 CFR part 1632 or IMO Resolution A.688(17). None of the vessels mattresses on board meet either standard. Provide documentation that the mattresses meet either standard or replace the mattresses with compliant mattresses.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2019
Resolved 25 May 2020
Resolution: 20 new bunk pads are purchased and installed, remainder to be purchased by 10/1/2020
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 22 February 2018Resolved
MI found one (01) Kapok filled lifejacket no longer serviceable.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 22 February 2018
Resolution: O/O replaced lifejacket on the spot.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 21 February 2017Resolved
Vessel must replace six (06) adult life jackets. Passenger count reduced by 06 to 89 passengers until life jackets replaced.
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 27 February 2017
Resolution: Provided 06 lifejackets to replace those decommissioned.
Construction/Loadline › Hull › Longitudinal Frame
Issued 30 November 2016Resolved
Crop and renew STBD member at clamp in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2016
Resolved 7 December 2016
Resolution: O/O renewed STBD member at clamp in engine room.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 30 November 2016Resolved
Make engine room aft bulkhead watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2016
Resolved 7 December 2016
Resolution: O/O made aft engineroom bulkhead watertight.
Construction/Loadline › Hull › Side Shell
Issued 30 November 2016Resolved
Treat uppermost planks at deck in engine room on port and STBD side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2016
Resolved 7 December 2016
Resolution: O/O satisfactorily treated uppermost planks at deck in engine room on port and STBD side.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 16 February 2016Resolved
Replace 02 adult life jackets.
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 16 February 2016
Resolution: Corrected on the spot
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.