A RACER is a 1996 freight ship. The Coast Guard has recorded 20 inspections since 1996, most recently in June 2017, along with 10 deficiencies and 6 operational controls.

Records from 1996 to 2017. Most recent: inspection, 8 June 2017.

Built
1996
Last inspected
8 June 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9086318 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
443236
Flag
LIBERIA
—
Maury page id
psix-443236

Inspections, by type

…with no type recorded10
Years with a record 9 calendar years (1996–2017)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it9280 - Convention (Subpart B), Net Ton
32783 - Displacement, Ton
26467 - Dead Weight, Ton
16041 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

8 June 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6169447
4 May 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6138595
27 September 2016 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6010544
25 September 2016 ISPS II Exam · COE-Offshore
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6008804
1 June 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5894605
23 May 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5879409
4 August 2014 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4943449
4 August 2014 ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4944036
19 June 2006 PII Safety Exam · Deficiency Check · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2684798
19 November 2004 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2244565
14 November 2004 ISPS II Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2239291
13 November 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2240375
2 March 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2017576
2 March 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2017865
28 February 2004 Ballast Water Examination · Deficiency Check · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2014899
2 January 2004 MARPOL Annex I Examination · Annual Inspection · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1970244
16 October 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 294554
7 April 2000 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 276369
10 November 1998 Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 422381
20 August 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 394570

Deficiency record · 10

Engineering › Fuel Oil Service System › Pump
Issued 4 May 2017 Resolved
74Solas(Con97)II-2/15.2 1499 In a ship in which fuel oil is used the arrangements for the storage distribution and utilization of the fuel oil shall be such as to ensure the safety of the ship and persons on board. the fuel oil recirculating pump was observed leaking approx .5 gallons per minute
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2017
Resolution: Repair of mechanical seal with new bearing and gasket installed.
Lifesaving › Lifeboat › Markings
Issued 4 May 2017 Resolved
74Solas(con97) III/41.9.3 0610 Means of identifying the ship to which teh lifeboat belongs and the number of the lifeboat shall be marked in such a way that they are visible from above.
Action required: 705 - Other - as specified
Due 4 June 2017
Resolved 8 May 2017
Resolution: Name of ship is marked together with Rescue boat indication and marking of No.1 at Starboard Life Boat, (Being Rescue Boat), and No.2 in Port Side boat.
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 4 August 2014 Resolved
Letter of Deviation issued in accordance with 33 CFR 165.35 for Automatic Radar Plotting Aid. Deficiency issued in accordance with MSM Vol. VI/1.I guidance.
Due 9 August 2014
Resolved 9 August 2014
Resolution: Letter of Deviation issued in accordance with 33 CFR 165.35 for Automatic Radar Plotting Aid. Deficiency issued in accordance with MSM Vol. VI/1.I guidance.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 June 2006 Resolved
PROTECTIVE COVERS FOR LIGHTS THROUGHOUT THE ENGINE ROOM CRACKED.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 May 2013
Resolution: Deficiencies were rectified to the satisfaction of the PSCO.
Electrical › Electric Generation Source (emergency) › Generator Cable
Issued 19 June 2006 Resolved
UNPROTECTED WIRING FOUND ON EMERGENCY GENERATOR BATTERIES AND ON THE EMERGENCY ESCAPE TRUNK.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 July 2006
Resolved 31 May 2013
Resolution: Deficiencies were rectified to the satisfaction of the PSCO.
Fire Fighting › Fire Pumps › Pressure
Issued 28 December 2003 Resolved
Emergency Fire pump was unable to supply water due to vessels current draft.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 January 2004
Resolution: Recieved Class society report stating emergency fire pump was tested with 3 hoses and able to provide three steady streams of water.
Fire Fighting › Fire Pumps
Issued 28 December 2003 Resolved
Ensure current design of emergency fire pump will operate under all conditions of list and trim. If current design is unable to operate under all conditions of list and trim provide class approved modifications to design that will allow the emergnecy fire pump to operate under all conditions. LEGACY COMPONENT DESC: Location
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 February 2004
Resolution: Received class report.
Personnel › Certificates/Documents/Licenses
Issued 28 December 2003 Resolved
Provide GMDSS endorsements for all navigational officers from flag state. STCW 95 AMEND LEGACY COMPONENT DESC: License, GMDSS Radio Operator
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 February 2004
Resolution: Cleared during PSC exam.
Documentation › Logs/Records
Issued 28 December 2003 Resolved
Commence making proper entries in oil record book according to the instructions provided in Appendix III of MARPOL Annex I. LEGACY COMPONENT DESC: Oil Record Book
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 February 2004
Resolution: Cleared during PSC exam.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 28 December 2003 Resolved
Update Transfer procedures to include all of the elements provided in 33 CFR 155.750.
Action required: 703 - Prior to bunkering operations
Resolved 3 January 2004
Resolution: Updated transfer procedures faxed to the office and all elements required in updated transfer procedures.

Ownership record