Records from 1996 to 2019. Most recent: inspection, 6 June 2019.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 26
6 June 2019
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6705423
15 June 2018
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6437918
14 April 2017
In-Service Inspection · DAPI Audit · Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6126240
20 October 2016
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6043630
17 September 2015
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5721592
17 June 2014
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4893107
16 June 2014
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4891060
2 December 2011
Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4200166
26 July 2011
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4094874
3 July 2011
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4069251
29 May 2008
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3210683
15 May 2007
Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2919923
22 June 2006
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2688371
7 June 2006
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2653461
6 April 2005
COI Inspection · Hull Examination
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2326299
24 July 2001
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1069322
7 July 2000
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1389132
29 June 2000
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1415398
22 March 1999
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1111335
24 August 1998
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 797582
17 July 1997
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1115098
26 September 1996
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1143512
19 July 1996
Plan Review "T" Boat
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1260346
17 July 1996
Deficiency Check · Initial Certification
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1086459
9 July 1996
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1088781
11 June 1996
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1260040
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 June 2018
No resolution recorded
Vessel has submersible bilge pumps that are not UL1113 approved. Provide new approved bilge pumps.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2018 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 15 June 2018
Resolved
Vessel does not have a rules of the road publication.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 June 2018
Resolved 15 June 2018
Resolution: Vessel provided a rules of the road publication.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 20 October 2016
Resolved
AVH01: Conduct MOB & Fire drill prior to carrying passengers
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2016
Resolved 14 April 2017
Resolution: Drills were witnessed satisfactory.
Construction/Loadline › Hull › Weld
Issued 17 September 2015
Resolved
There is a cracked weld IWO of STBD side rear wheel FWD of wheel well. V/W. Contact attending CG mairne inspector when repairs are made
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 24 September 2015
Resolved 5 October 2015
Resolution: Weld repairs made to the crack weld.
Engineering › Fuel Oil Service System › Pump
Issued 17 June 2014
Resolved
12vdc fuel pump electrical connection loose, make proper repairs and test prior to passenger operations
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2014
Resolved 19 June 2014
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 December 2011
Resolved
The vessel's total persons allowed has been reduced to 25 persons. This requirement is effective until you come into compliance with the new stability regulations.
Action required: 705 - Other - as specified
Due 2 December 2011
Resolved 6 December 2011
Resolution: Received operator''s letter of compliance.
Lifesaving › Hand Flares › Not on Board
Issued 7 June 2006
Resolved
Obtain required smoke and flares prior to conducting commercial operations.Fax receipt to USCG.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 22 June 2006
Resolution: Corrected this date
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 7 June 2006
Resolved
Registration number diplayed on vessel does not match certificate of regitration.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 22 June 2006
Resolution: Corrected this date
Fire Fighting › Fire Bucket › Lanyard
Issued 7 June 2006
Resolved
Fire buckets are missing the required lanyards.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 22 June 2006
Resolution: Corrected this date
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 June 2006
Resolved
Lifering light found with a dead battery.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 22 June 2006
Resolution: Corrected this date
Engineering › Bilge Water Management System › Pump
Issued 6 April 2005
Resolved
COMPLETE INSTALLATION OF FORWARD BILGE PUMP AND REPAIR BILGE ALARM BUZZER.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 July 2005
Resolved 11 July 2005
Resolution: BILGE PUMPS AND BILGE ALARMS REPAIRED.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 April 2005
Resolved
PROVIDE FIRST AID KIT.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 July 2005
Resolved 11 July 2005
Resolution: FIRST AID KIT PROVIDED.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 6 April 2005
Resolved
COMPLETE INSTALLATION OF THE ENGINEROOM FIXED FIRE FIGHTING SYSTEM AS PER 46 CFR 181.420 INCLUDING REMOTE PULL OUTSIDE OF THE SPACE AND OPERATING LIGHT.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2006
Resolved 7 June 2006
Resolution: Noted as corrected this date.
Fire Fighting › Fire Bucket › Quantity
Issued 6 April 2005
Resolved
PROVIDE 3 -- 2 1/2 GALLON BUCKETS MARKED WITH "FIRE BUCKET" IN 1" LETTERS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 July 2005
Resolved 11 July 2005
Resolution: FIRE BUCKETS PROVIDED.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 6 April 2005
Resolved
MOUNT B-I AND B-II FIRE EXTINGUISHERS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 July 2005
Resolved 11 July 2005
Resolution: FIRE EXTINGUISHERS MOUNTED.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 6 April 2005
Resolved
PROVIDE 2 PORTABLE FLASHLIGHTS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 July 2005
Resolved 11 July 2005
Resolution: FLASHLIGHTS PROVIDED.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 6 April 2005
Resolved
LABEL FUEL OIL SHUTOFFS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 July 2005
Resolved 11 July 2005
Resolution: SHUTOFFS LABELED.
Documentation › Markings/Placards › Capacity Marking
Issued 6 April 2005
Resolved
MARK WITH PAINT THE BOTTOM AFT DRAFT MARK FOR LOADING LIMIT.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 July 2005
Resolved 11 July 2005
Resolution: DRAFT MARKS PAINTED.
Construction/Loadline › Hull › Hull Plating
Issued 6 April 2005
Resolved
SEAL ALL OPEN HOLES ON THE EXTERIOR HULL AND DECK.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 July 2005
Resolved 11 July 2005
Resolution: HOLES SEALED UP.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 April 2005
Resolved
POST ALL DOCUMENTS INCLUDING COI, LIFE JACKET DONNING PROCEDURES, EMERGENCY PROCEDURES, POLLUTION PLACARD, STABILITY LETTER, ETC.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 July 2005
Resolved 11 July 2005
Resolution: DOCUMENTS POSTED.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 6 April 2005
Resolved
CONDUCT UNDERWAY DRILLS AND OPERATINS FOR FINAL TESTING.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 July 2005
Resolved 12 July 2005
Resolution: UNDERWAY DRILLS COMPLETED.
Construction/Loadline
Issued 17 July 1996
Resolved
PROVE PROPER OPERATION OF THE PORT AFT HYDRAULIC BILGE PUMP.
Condition: Unknown
Due 17 August 1996
Resolved 10 September 1996
Documentation
Issued 17 July 1996
Resolved
PROVE COMPLIANCE WITH THE DRUG TESTING REQUIREMENTS CONTAINED IN 46 CFR PART 16.
Condition: Unknown
Due 17 August 1996
Resolved 10 September 1996
Engineering
Issued 17 July 1996
Resolved
INSTALL FUEL TANK VENTING IN SUCH A MANNER SO AS TO PRECLUDE VAPOR DISCHARGES INTO PASSENGER SPACES.
Condition: Unknown
Due 17 August 1996
Resolved 10 September 1996
Accommodation/Occupational Safety
Issued 17 July 1996
Resolved
PROVIDE VENTILATION FOR THE DRIVE TRAIN/FUEL TANK SPACE AS OUTLINED IN 46 CFR 182.470.
Condition: Unknown
Due 17 July 1996
Resolved 23 July 1996
Lifesaving
Issued 9 July 1996
Resolved
PROVIDE EMERGENCY INSTRUCTIONS AND PFD DONNING PLACARDS IN ACCORDANCE WITH 46 CFR 185.510 AND 185.516 RESPECTIVELY.
Condition: Unknown
Due 17 July 1996
Resolved 23 July 1996
Fire Fighting
Issued 9 July 1996
Resolved
PROVIDE THREE WATER BUCKETS AS REQUIRED BY 46 CFR 181.610.
Condition: Unknown
Due 17 July 1996
Resolved 23 July 1996
Fire Fighting
Issued 9 July 1996
Resolved
PROVIDE AN ADDITIONAL COAST GUARD APPROVED TYPE BII PORTABLE FIRE EXTINGUISHER PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 17 July 1996
Resolved 23 July 1996
Electrical
Issued 9 July 1996
Resolved
PROVIDE TWO PORTABLE LIGHTS IN ACCORDANCE WITH 46 CFR 183-430.
Condition: Unknown
Due 17 July 1996
Resolved 23 July 1996
Lifesaving
Issued 9 July 1996
Resolved
PROVIDE A COAST GUARD APPROVED WATERLIGHT, LANYARD, LINE AND RETROREFLECTIVE MATERIAL PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 17 July 1996
Resolved 23 July 1996
Construction/Loadline
Issued 11 June 1996
Resolved
WELD GOUGE IN BOTTOM, AFT OF STARBOARD AFT WHEEL WELL.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Construction/Loadline
Issued 11 June 1996
Resolved
WELD INSIDE OF PREVIOUSLY INSTALLED INSERT, AFT PORT SIDE OF ENGINE COMPARTMENT.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996