MAURY USCG vessel records Sign in
← All vessels

CAPE JOHN

CAPE JOHN is a 1962 freight ship. The Coast Guard has recorded 72 inspections since 1982, most recently in May 2014, along with 90 deficiencies — 1 with no resolution recorded —.

Records from 1982 to 2014. Most recent: inspection, 20 May 2014.

Built
1962
Last inspected
20 May 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

5056274 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
UNITED STATES
366328000 (licence lapsed)
Maury page id
psix-44388

Inspections, by type

…with no type recorded31
Years with a record 25 calendar years (1982–2014)
The 72 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it12724 - Regulatory (Subpart C or D), Gross Ton
9345 - Dual (D), Gross Ton
8180 - Regulatory (Subpart C or D), Net Ton
5486 - Dual (D), Net Ton
14952 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

KGTPMMSI 366328000 · expired · compulsorily equipped · granted 12 August 1996, cancelled 16 December 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 72

20 May 2014 Load Line/Change of Employment
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4863750
17 January 2005 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2276027
3 June 2004 MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2087321
23 February 2004 Administrative Inspection
Administrative · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2020266
28 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1995668
20 January 2004 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1985293
11 September 2003 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1905737
18 January 2003 Damage Survey
Physical examination · Activities Europe · Activity 1730579
9 January 2003 Type not recorded
No type recorded · Activities Europe · Activity 2012660
17 December 2002 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1723061
23 May 2002 Annual Inspection · Underwater Inspection in lieu of Drydock · Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1618848
19 March 2002 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1494765
10 October 2001 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1393790
30 August 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1452843
19 July 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1406947
10 October 2000 COI Inspection · Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1433717
20 August 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 135568
26 January 2000 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 814537
14 January 2000 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 814731
2 December 1999 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1432203
29 October 1998 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1473033
28 September 1998 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1368870
18 September 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1392975
17 August 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 795774
6 March 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1118688
20 January 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1114239
28 October 1997 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1115084
25 June 1997 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1390618
9 December 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1091170
15 September 1996 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1430312
6 June 1996 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1185982
30 May 1996 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1084825
7 May 1996 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1083358
5 May 1996 Hull Examination · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1457339
6 March 1995 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 856884
6 March 1995 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 857041
14 November 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1176931
31 October 1994 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1459129
13 October 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1176027
21 July 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1446108
3 June 1994 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 861798
12 January 1994 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 850354
29 November 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1158053
29 November 1993 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1158479
22 November 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 847811
9 September 1993 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1146390
23 October 1992 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 951719
29 July 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 136104
18 April 1991 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 914577
21 February 1991 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 480826
19 February 1991 Examination of Repairs
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 928340
5 February 1991 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 996010
15 January 1991 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1239855
29 December 1990 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 934839
22 December 1990 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1220861
18 October 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 928522
6 August 1990 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1228375
30 May 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 902891
14 March 1990 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1214666
24 May 1989 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1219509
28 September 1988 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1352664
3 June 1987 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1312115
1 June 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1335397
3 September 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1016989
5 July 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1291805
15 May 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1286732
10 May 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 977835
3 April 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 982335
4 March 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1289039
25 May 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 973483
5 October 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1277386
22 September 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 965640

Deficiency record · 90

Navigation › Collision/Grounding Avoidance › Transponder
Issued 20 January 2004 No resolution recorded
WITNESSED INSTALLATION OF MOUNTING EQUIPMENT AND THRU HULL PENATRATIONS FOR SPEED LOG EQUIPMENT PER OUTSTANDING DEFICIENCY. EQUIPMENT MUST BE INSTALLED AND PROPER OPERATION DEMONSTRATED TO ATTENDING MARINE INSPECTOR PRIOR TO NEXT ACTIVATION.
Action required: 705 - Other - as specified
Engineering › Bilge Water Management System
Issued 11 September 2003 Resolved
Properly install support bracket for emergency bilge suction reach rod NLT 11NOV03 to the satisfaction of the attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 11 November 2003
Resolved 30 September 2003
Resolution: Bracket installed and inspected satisfactorily.
Fire Fighting › Fire Pumps
Issued 11 September 2003 Resolved
Repair or remove inoperable pressure gauge for fire pump on bridge prior to departure from port. LEGACY COMPONENT DESC: Pressure
Action required: 17 - Rectify deficiencies prior to departure
Due 11 September 2003
Resolved 30 September 2003
Resolution: Inoperable pressure gauge was removed and line plugged.
Lifesaving › Lifebuoys
Issued 11 September 2003 Resolved
Repair and prove proper operation of the port bridge wing ring bouy releasing mechanism prior to departure from port to the satisfaction of the attending CG Marine Inspector. LEGACY COMPONENT DESC: Stowage
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 11 September 2003
Resolved 30 September 2003
Resolution: Corrected
Navigation › Piloting/Steering
Issued 11 September 2003 Resolved
Repair and prove proper operation of the loss of power steering alarm on the bridge prior to departure from port to the satisfaction of the attending CG Marine Inspector
Action required: 17 - Rectify deficiencies prior to departure
Due 11 September 2003
Resolved 30 September 2003
Resolution: A loose wire was found and corrected.
Navigation › Collision/Grounding Avoidance
Issued 11 September 2003 Resolved
Vessel is to install a device to indicate speed and distance (speed log) IAW 33 CFR 164.40 during it's next drydock period OOA December 2003. Proper operation of the speed log shall be demonstrated to the satisfaction of the attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 31 December 2003
Resolved 12 March 2004
Lifesaving › Lifeboat Equipment
Issued 11 September 2003 Resolved
Vessel is to replace the expired batteries for the 2 lifeboat portable VHF radio's prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 September 2003
Resolved 30 September 2003
Resolution: New batteries were provided.
Lifesaving › Lifejacket/PFD (Type I)
Issued 11 September 2003 Resolved
Vessel is to replace the defective retroreflective tape and chem lights, as needed, on the type I PFD's prior to departure from port. LEGACY COMPONENT DESC: Lights
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 11 September 2003
Resolved 30 September 2003
Resolution: Tape and lights were provided as needed.
Lifesaving › Launching Appliances
Issued 11 September 2003 Resolved
Falls for lifeboats were changed, but never weight tested. Falls shall be weight tested to 1.1. times the lifeboats "B" weight in the presence of a CG Marine Inspector during the vessels next drydock period OOA December 2003. LEGACY COMPONENT DESC: Falls
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 December 2003
Resolved 11 March 2004
Lifesaving
Issued 11 September 2003 Resolved
Vessel must install the required SOLAS signage thru-out the accomadation spaces prior to being broke out of inactive status to the satisfaction of the attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 31 December 2003
Resolved 19 June 2004
Deck/Cargo › Holds/Tanks
Issued 11 September 2003 Resolved
Vessel must replace/reinstall hatch cover gaskets on holds #2 and #3 prior to departure from port and to the satisfaction of the attending CG Marine Inspector. LEGACY COMPONENT DESC: Hatch Cover
Action required: 705 - Other - as specified
Due 11 September 2003
Resolved 30 September 2003
Resolution: New gaskets were installed.
Navigation › Piloting/Steering
Issued 11 September 2003 Resolved
Vessel must calibrate the gyrocompass repeater in aft steering to match the master gyrocompass prior to departure from port. LEGACY COMPONENT DESC: Gryo Compass Repeater
Action required: 17 - Rectify deficiencies prior to departure
Due 11 September 2003
Resolved 30 September 2003
Resolution: Calibration completed.
Lifesaving › Lifeboat
Issued 11 September 2003 Resolved
Vessel must replace the retroreflective tape and mark the call sign on both lifeboats prior to departure from port and to the satisfaction of the attending CG Marine Inspector. LEGACY COMPONENT DESC: Markings
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 11 September 2003
Resolved 30 September 2003
Resolution: Corrected.
Navigation › Collision/Grounding Avoidance
Issued 11 September 2003 Resolved
One of the vessels two required radars was found to be inoperable. Correction required prior to departing port. LEGACY COMPONENT DESC: Radar
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2003
Resolved 11 October 2003
Resolution: Radar technician reported received.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 11 September 2003 Resolved
The time delays for the fixed CO2 and Halon fire systems were found to either open prematurely or to late. A total of 4 time delays are required to be replaced and there operation demonstrated to the attending CG Marine Inspector prior to departing port. LEGACY COMPONENT DESC: Operating Controls
Action required: 705 - Other - as specified
Due 30 September 2003
Resolved 15 October 2003
Resolution: Time delays replaced and tested satisfactorily.
Electrical › Electric Generation Source (service)
Issued 18 January 2003 Resolved
#1 SSTG had a blade failure in the sixth stage turbine wheel blade assembly. Total of six blades were removed either due to damage or to balance the turbine rotor. S/S underway load of 500 KW was applied and generator operated properly. Vessel rep to provide permanent repair proposal. LEGACY COMPONENT DESC: Generator
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 March 2003
Resolved 11 September 2003
Resolution: corrected.
Lifesaving › Inflatable Liferafts
Issued 18 January 2003 Resolved
Properly install 04 new liferafts once received by the ship. LEGACY COMPONENT DESC: Capacity
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2003
Resolved 11 September 2003
Resolution: corrected.
Lifesaving › Inflatable Liferafts
Issued 18 January 2003 Resolved
Provide plans, fabricate and install liferaft storage racks that will allow all rafts to be deployed over the side without lifting more than one foot.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 April 2003
Resolved 11 September 2003
Resolution: corrected.
Lifesaving › Inflatable Liferafts
Issued 18 January 2003 Resolved
Mount all life raft launching procedures in an area where they can be seen under emergency lighting.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 April 2003
Resolved 11 September 2003
Resolution: Procedures mounted on inboard bulkhead of embarkation deck. Embarkation lights are able to swivel in order to see the procedures. This arrangement was accepted.
Electrical › Electric Supply System (service)
Issued 18 January 2003 Resolved
Properly operate and test portable deck generator. Insure approved cable is properly routed to main switchboard and does not compromise structural fire protection of any bulkheads that it passes through. Port engineer is to forward a statement of the above from ABS class surveyor. LEGACY COMPONENT DESC: Cable
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2003
Resolved 11 September 2003
Resolution: Portable generator removed. Cleared requirment.
Fire Fighting › Structural - A Class Divisions
Issued 18 January 2003 Resolved
Make all fire screen doors leading to engineroom vapor/smoke tight. LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2003
Resolved 11 September 2003
Resolution: corrected.
Fire Fighting › Structural - A Class Divisions
Issued 18 January 2003 Resolved
Remove all hold back hooks and make all fire screen doors leading to stairtower and engineroom self closing. LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2003
Resolved 11 September 2003
Resolution: corrected.
Electrical › Electric Generation Source (service)
Issued 11 November 2002 Resolved
Install machinery guards over S/S/D/G generator shaft end bolts and turning gear motor shaft/coupling. LEGACY COMPONENT DESC: Machinery Guards
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 17 December 2002
Resolution: Guards installed.
Engineering › Pressure Vessel
Issued 11 November 2002 Resolved
Prove proper operation of pressure relief valves on fwd and aft MCDS systems. This requirement must be completed prior to utilizing the generators. LEGACY COMPONENT DESC: Relief Valve
Action required: 705 - Other - as specified
Resolved 16 December 2002
Resolution: As per COMDTG-MVI-1/14 (16711) ltr dtd August 22, 1988 this system is not required to be inspected.
Electrical › Electric Generation Source (service)
Issued 11 November 2002 Resolved
Properly label both fwd and aft diesel cut-off pull stations for MCDS system generators. This requirement must be completed prior to using the MCDS generators. LEGACY COMPONENT DESC: MCDS Generators
Action required: 705 - Other - as specified
Resolved 16 December 2002
Resolution: As per COMDT G-MVI-1/14 (16711) ltr dtd August 22, 1988 this system is not required to be inspected.
Stability › Water on Deck
Issued 11 November 2002 Resolved
Provide deck drain grates for all deck drains, all levels. LEGACY COMPONENT DESC: Deck Drain Grates
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 December 2002
Resolved 11 September 2003
Resolution: Corrected.
Electrical › Lighting (service)
Issued 11 November 2002 Resolved
Cargo hold #5, cooler room # 19, install marine grade light switch, properly label all emergency lighting locations that are painted over throughout hold #5. LEGACY COMPONENT DESC: Switch
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 December 2002
Resolved 17 December 2002
Resolution: Marine grade lightswitch installed and in proper operation. Vessel electrician in process of installing emergencylighting labels at time of inspection.
Electrical › Electrical Distribution System (service)
Issued 11 November 2002 Resolved
Helo deck - Remove Jog controls (02) that are no longer in service. LEGACY COMPONENT DESC: Jog Switch
Action required: 705 - Other - as specified
Due 11 December 2002
Resolved 17 December 2002
Resolution: Jog controls removed.
Communications › Radio Communications
Issued 11 November 2002 Resolved
Provide valid registration for EPIRB. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 11 December 2002
Resolved 17 December 2002
Resolution: Corrected.
Documentation › Certificates/Documents
Issued 11 November 2002 Resolved
Provide interim ABS survey results of UWILD to the [name withheld], Texas. LEGACY COMPONENT DESC: UWILD SURVEY REPORT
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2002
Resolution: Received, reviewed, and accepted ABS Survey report dtd 15 Nov 2002.
Communications › Alarms/Indicators
Issued 8 November 2002 Resolved
1. Prove proper operation of the general alarm bell on the helo deck. Item must be completed before helo operations commence. LEGACY COMPONENT DESC: General Alarm
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 11 September 2003
Resolution: corrected.
Fire Fighting › Fire Pumps
Issued 8 November 2002 Resolved
Foam System/Helo Deck - Noted the following descrepancies: Hose reel units were not pressure tested, gauges on the discharge side were inop., the pump was disconnected, and the stations were not marked. LEGACY COMPONENT DESC: Power Source
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 November 2002
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 8 November 2002 Resolved
Both Helo deck portable CO2 locations were not marked and the cabinet doors would not close due to excessive corrosion of the metal housing and hinges. LEGACY COMPONENT DESC: Marking
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 November 2002
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 8 November 2002 Resolved
Halon system for MCDS generator room, fwd remote activation station, noted Nitrogen starter cylinder was out of inspection date. Also, same station, noted the housing would open only by applying excessive pulling on the door bottom. Aft location was not marked.
Action required: 705 - Other - as specified
Resolved 11 November 2002
Resolution: Fire Protection Services resolved these issues.
Fire Fighting
Issued 10 October 2001 Resolved
replace mounting base to emergency fire pump._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 November 2001
Resolved 19 March 2002
Resolution: Base has been renewed to satisfaction of attending Marine Inspector and ABS surveyor.
Fire Fighting
Issued 10 October 2001 Resolved
provide fire control and safety plans (rev C) IAW MSO Port Arthur approval letter dated 06 MAR 98.
Condition: Unknown
Due 10 November 2001
Resolved 19 March 2002
Resolution: Sighted approved plans (approved by USCG on 06MAR98).
Lifesaving
Issued 10 October 2001 Resolved
Conduct weight test on starboard lifeboat._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 November 2001
Resolved 18 October 2001
Resolution: Conducted satisfactory weight test.
Lifesaving
Issued 10 October 2001 Resolved
Properly secure grate to #46 exhaust vent fan located outside the winck machinery room.
Condition: Unknown
Due 10 November 2001
Resolved 19 March 2002
Resolution: Grate secured to satisfaction of attending Marine Inspector.
Fire Fighting
Issued 10 October 2001 Resolved
install proper hinge to the #47 exhast vent fan fire closure located outside the winch machinery room.
Condition: Unknown
Due 10 November 2001
Resolved 19 March 2002
Resolution: Hinge has been renewed to satisfaction of attending Marine Inspector.
Lifesaving
Issued 10 October 2001 Resolved
Blank off flanges to the port side deck (unrep) locker._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 November 2001
Resolved 19 March 2002
Resolution: Flanges blanked off to satisfaction of attending Marine Inspector.
Electrical
Issued 10 October 2001 Resolved
provide proper plate cover/ caps for the #5 MG house electrical outlet.
Condition: Unknown
Due 10 November 2001
Resolved 19 March 2002
Resolution: Sighted installation of new covers.
Lifesaving
Issued 10 October 2001 Resolved
Repair or replace natural supply inlet vent to the port side deck (unrep) locker._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 November 2001
Resolved 19 March 2002
Resolution: Vent renewed to satisfaction of attending Marine Inspector.
Documentation
Issued 10 October 2000 Resolved
SUBMIT STEERING MODIFICATION DRAWINGS TO MSC FOR APPROVAL AND PROVIDE APPPROVAL LETTER TO LOCAL OCMI.
Condition: Unknown
Due 5 November 2000
Resolved 11 September 2003
Resolution: Corrected
Electrical
Issued 10 October 2000 Resolved
OPEN #1 SSTG GEARBOX TO INVESTIGATE EXCESSIVE NOISE.
Condition: Unknown
Due 5 November 2000
Resolved 18 October 2000
Engineering
Issued 10 October 2000 Resolved
RENEW SIGHT GLASS STOP VALVES OF P/S BOILERS OR OPEN FOR INSPECTION.
Condition: Unknown
Due 10 October 2000
Resolved 10 October 2000
Navigation
Issued 14 January 2000 Resolved
INSTALL PROPER BRIDGE CONTROL FOR STEERING SYSTEM IAW 46CFR 58-25.70.
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Lifesaving
Issued 14 January 2000 Resolved
CONDUCT FIRE AND BOAT DRILL PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Engineering
Issued 14 January 2000 Resolved
CONDUCT MAIN TURBINE OVERSPEED TRIP AFTER GETTING UNDERWAY AT SEA.
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Electrical
Issued 2 December 1999 Resolved
PROPERLY LABEL ELECTRICAL PANELS THROUGHOUT VESSEL.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Construction/Loadline
Issued 2 December 1999 Resolved
PROPERLY REPAIR WTD ON FWD PAINT LOCKER, UNREP LOCKER, AND CARGO HOLD NO. 4PORT SIDE.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Engineering
Issued 2 December 1999 Resolved
PROPERLY CLEAN OR REPLACE FLAME SCREENS THROUGHOUT VESSEL.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Engineering
Issued 2 December 1999 Resolved
CONDUCT MAIN TURBINE OVERSPEED TRIP AFTER GETTING UNDERWAY AT SEA.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Engineering
Issued 2 December 1999 Resolved
REMOVE IMPROPER RELIEF VALVE FOR ATOMIZING STEAM LINE, STBD BOILER & RENEW WITH PROPER VALVE AND SET PRESSURE.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Navigation
Issued 2 December 1999 Resolved
INSTALL PROPER BRIDGE CONTROL FOR STEERING SYSTEM IAW 46CFR 58-25.70.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Fire Fighting
Issued 2 December 1999 Resolved
CONDUCT FIRE AND BOAT DRILL PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Engineering
Issued 28 September 1998 Resolved
PROVE PROPER OPERATION OF REACH RODS FOR FUEL OIL SERICE PORT SUCTION FROM FUEL OIL SETTLER TANK S-1, TRANSFER SUCTION FROM FUEL SERVICE TANK S-1 AND INBOARD PORT TRANSFER SUCTION VALVE. VALVES TO REMAIN LOCKED & CLOSED UNTILREQMT IS MET.
Condition: Unknown
Due 28 September 1998
Resolved 28 September 1998
Engineering
Issued 28 September 1998 Resolved
PROVIDE SANBOX FOR ENG ROOM PRIOR TO SAILING._x001C_
Condition: Unknown
Due 29 September 1998
Resolved 29 September 1998
Deck/Cargo
Issued 28 September 1998 Resolved
REPAIR/REPLACE VENT ON FOSCLE, PORT SIDE NEAR EXHAUST OUTLET.
Condition: Unknown
Due 28 September 1998
Resolved 28 September 1998
Lifesaving
Issued 28 September 1998 Resolved
CONDUCT OPERATIONAL TEST OF PORT LIFE BOAT, LOWERING TO WATER & PROVE PROPER OPERATION OF RELEASING GEAR.
Condition: Unknown
Due 28 September 1998
Resolved 28 September 1998
Fire Fighting
Issued 28 September 1998 Resolved
CORRECT CO2 DIAGRAM TO SHOW MODIFICATION (ADDITIONAL 'TWEEN DECK) ON DECK SERVED BY LINE #5.
Condition: Unknown
Due 28 September 1998
Resolved 28 September 1998
Navigation
Issued 28 September 1998 Resolved
PROVIDE MAGNETIC COMPASS DEVIATION CARD.
Condition: Unknown
Due 28 September 1998
Resolved 28 September 1998
Construction/Loadline
Issued 28 September 1998 Resolved
TIGHTEN PACKING TO CORRECT EXCESS LEAKING ON ENG RM BILGE SUCTION.
Condition: Unknown
Due 28 September 1998
Resolved 28 September 1998
Construction/Loadline
Issued 28 September 1998 Resolved
RELABEL ENGINE ROOM BILGE MANIFOLD, SEVERAL VALVES ARE MISLABELED. PROVE PROPER OPERATION IN ALL CARGO HOLDS ONCE RELABLED.
Condition: Unknown
Due 28 September 1998
Resolved 28 September 1998
Unknown
Issued 28 September 1998 Resolved
PAINT WARNING ON EMBARKATION DECK, WARNING OF BOAT GRIPS DURING BOAT OPS ORWORDS TO THAT EFFECT.
Condition: Unknown
Due 28 September 1998
Resolved 28 September 1998
Construction/Loadline
Issued 28 September 1998 Resolved
PERM. INSTALL (1) BILGE PUMP TO REPLACE THE INSTALLED M15.
Condition: Unknown
Due 28 September 1998
Resolved 28 September 1998
Electrical
Issued 5 May 1996 Resolved
Determine source and correct electrical system ground faults at main switchboard.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Electrical
Issued 5 May 1996 Resolved
Seperate deadended electrical cable in ladder stairwell between steering compartment & shaft alley from electrical source.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Engineering
Issued 5 May 1996 Resolved
Demonstrate proper operation of low low water control on port boiler to satisfaction of attending USCG Marine Inspector.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Engineering
Issued 5 May 1996 Resolved
Conduct hydrostatic test of main steam piping and auxiliary steam piping inthe presence of a USCG Marine Inspector.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Accommodation/Occupational Safety
Issued 5 May 1996 Resolved
Demonstrate operation of general alarm bell in shaft alley to USCG Marine Inspector.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Lifesaving
Issued 5 May 1996 Resolved
Provide documentation of renewal of lifeboat falls to cognizant OCMI._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 May 1996
Resolved 5 May 1996
Lifesaving
Issued 5 May 1996 Resolved
Conduct weight test of port & starboard lifeboats to in the presence of a USCG Marine Inspector.
Condition: Unknown
Due 5 May 1996
Resolved 5 May 1996
Construction/Loadline
Issued 5 May 1996 Resolved
Demonstrate operation of bilge suction system for #4 and #5 cargo hold to cognizant [name withheld] pumps to be rigged for immediate use in interim period.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Fire Fighting
Issued 5 May 1996 Resolved
Renew vent dampers in way of ladder well from steering gear compartment to shaft alley.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Engineering
Issued 5 May 1996 Resolved
Demonstrate proper operation of oily water separator to USCG Marine Inspector. No overboard discharge of machinery space bilges is permitted.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Engineering
Issued 5 May 1996 Resolved
Repair drum and pilot boiler safety relief valves blowdowns on both port and starboard boilers.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Fire Fighting
Issued 21 July 1994 Resolved
Provide evidence of Marine Safety Center approval for "As Built" Fixed CO2 System installation and modifications conducted MAY/JUN94 prior to placing the vessel into service.
Condition: Unknown
Due 21 July 1994
Resolved 21 July 1994
Documentation
Issued 21 July 1994 Resolved
Provide accurate Tonnage Certificate reflecting Spring/94 shipyard conversion/construction in way of Cargo Hold deck modifications and additions prior to placing vessel into service.
Condition: Unknown
Due 21 July 1994
Resolved 21 July 1994
Engineering
Issued 21 July 1994 Resolved
Provide for boiler mounts on Starboard Propulsion Boiler to be opened and inspected by the Marine Inspector prior to lighting off the boiler and no later than 01OCT94.
Condition: Unknown
Due 21 July 1994
Resolved 21 July 1994
Engineering
Issued 21 July 1994 Resolved
Provide for boiler mounts on Port Propulsion Boiler to be opened and inspected by the Marine Inspector prior to lighting off the boiler and no later than 01OCT94.
Condition: Unknown
Due 21 July 1994
Resolved 21 July 1994
Construction/Loadline
Issued 9 September 1993 Resolved
MAINTAIN TEMPORARY REPAIRS TO CARGO HOLD HATCHES UNTIL PERMANENT REPAIRS CAN BE MADE AS PER YOUR LETTER DATED 01SEP93.
Condition: Unknown
Due 9 September 1993
Resolved 9 September 1993
Lifesaving
Issued 23 October 1992 Resolved
CONDUCT A FIRE AND BOAT DRILL IN THE PRESENCE OF A USCG MARINE INSPECTOR ATTIME OF ACTIVATION.
Condition: Unknown
Due 23 October 1992
Resolved 23 October 1992
Accommodation/Occupational Safety
Issued 5 February 1991 Resolved
PROVIDE COAST GUARD APPROVED PLANS ON BOARD THE VESSEL FOR PIPING AND _x001C_ ELECTRICAL MODIFICATIONS AND/OR NEW INSTALLATIONS FOR THE RECENTLY _x001C_ INSTALLED EVAPORATORS AND MSD._x001C_ _x001C_
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Documentation
Issued 22 December 1990 Resolved
PROVIDE TUG SERVICE UNTIL VESSEL CLEARS MOUTH OF MISSISSIPPI RIVER.
Condition: Unknown
Due 22 December 1990
Resolved 22 December 1990
Accommodation/Occupational Safety
Issued 22 December 1990 Resolved
INSTALL MSD, AND PROVIDE PORTABLE TOILET FACILITIES WHEN IN U.S. WATERS.
Condition: Unknown
Due 22 December 1990
Resolved 22 December 1990
Deck/Cargo
Issued 22 December 1990 Resolved
MAKE PERMANENT REPAIRS TO WOODEN PLUGS IN CONTAINMENT FOR VENTS ON MAIN DECK.
Condition: Unknown
Due 22 December 1990
Resolved 22 December 1990
Lifesaving
Issued 22 December 1990 Resolved
END FOR END LIFEBOAT FALLS, STBD BOAT, AND CONDUCT WEIGHT TEST STBD BOAT.
Condition: Unknown
Due 22 December 1990
Resolved 22 December 1990
Construction/Loadline
Issued 14 March 1990 Resolved
REPAIR CRACKED WELD AROUND FWD LADDER COAMING IN #4 PORT DEEP TANK. CRACKEDWELD IS APPROXIMATELY #10 LONG.
Condition: Unknown
Due 14 March 1990
Resolved 14 March 1990
Construction/Loadline
Issued 14 March 1990 Resolved
REPAIR CRACKED WELD IN TANK TOP DECK OF #6 STBD DEEP TANK. CRACK IS LOCATEDWHERE FWD BLHD OF TANK AND TANK TOP ARE WELDED.
Condition: Unknown
Due 14 March 1990
Resolved 14 March 1990
Construction/Loadline
Issued 14 March 1990 Resolved
RENEW ALL EXPANSION JOINTS IN E/R(8) ACCORDING TO 46CFR 61.15-12.
Condition: Unknown
Due 14 March 1990
Resolved 14 March 1990

Ownership record