Records from 2019 to 2023. Most recent: inspection, 26 September 2023.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 July 2023
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed two of the type "A" relief valves in the CO2 room with the safety pins in place. While PSCO continued with exam chief officer instructed cadet to remove the pins resulting in the CO2 lines for the scrubber system to be energized.
74 SOLAS(20) II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 25 July 2023
Resolved 25 July 2023
Resolution: Class report was recieved in atesting to the repairs to the CO2 system.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 July 2023
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed active fuel leaks on several connection points on the #2, #3, and #4 main diesel generators. Additionally, there was oil accumulation under #3 and #4 main diesel generator turbos.
74 SOLAS(97)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 25 July 2023
Resolved 26 July 2023
Resolution: BV class report was recieved attesting to the repairs (see report atatched).
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 July 2023
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in normal manner. PSCO observed covers missing on switch board buttons in the vicinity of the #3 main diesel generator. Additionally, PSCO observed cracked light covers and exposed wires on several connections throughout the engine room.
74 SOLAS(97) II-I/45.1.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 July 2023
Resolved 26 July 2023
Resolution: BV class report was recieved attesting to the repairs (see report atatched).
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 24 July 2023
Resolved
After any survey of the ship has been completed, no change shall be made in the structural arrangement, machinery, equipment and other items covered by the survey, without the sanctions of the administration. PSCO observed modifications made by the crew to the main diesel generator lube oil centrifugal pump arrangement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2023
Resolved 26 September 2023
Resolution: Class attested to repairs.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 July 2023
Resolved
The arrangements for the storage, distribution, and utilization of other flammable oils… shall be such as to ensure the safety of the ship and persons on board. PSCO witnessed excessive oil accumulation near main engine cylinders, auxiliary generators, oil purifying space, and HFO settling tank. Throughout the engine room, oil-soaked lagging was present and active leaks were observed on the auxiliary generators. Lagging over critical machinery components has been painted over, eliminating the possibility to identify if and components are leaking. In addition, numerous oil-soaked rags were removed from concealed locations. The amount of standing oil combined with the presence of excessive combustible materials in the engine room poses an increased probability of ignition within the engine room, thus endangering the crew, the port, and the environment.
74SOLAS(97 CONS) II-2/15.4
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 21 July 2023
Resolution: Oil accumulaton and oil soaked lagging removed. Leaks identified and rectified.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 20 July 2023
Resolved
Where "A" class divisions are penetrated for the passage of electric cables… arrangements shall be made to ensure that the fire resistance is not impaired.. Penetration for shore tie between tunnel and main engine room found unsealed in vicinity of improperly stowed fuel samples. Penetrations through superstructure identified by FCP as "A" class boundaries found penetrated and not properly sealed near main deck entrance into house.
74SOLAS(97 CONS) II-2/44.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 21 July 2023
Resolution: Penetration properly sealed and approved by class.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 20 July 2023
Resolved
For determining the appropriate fire integrity standards to be applied to divisions between adjacent spaces, such spaces are classified according to their fire risk as shown in categories (1) to (11) below. PSCOs discovered MARPOL fuel samples stored in ship's tunnel in unapproved storage container. The samples are required to be stored in category (9) spaces with "A" class boundaries.
74SOLAS(97 CONS) II-2/44.2.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 21 July 2023
Resolution: Fuel samples removed and relocated to space approved for storage of flammable liquids.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 July 2023
Resolved
The fire resistance of doors shall, as far as practicable, be equivalent to that of the division in which they are fitted. "A" Class self-closing door between ECR and engine room missing locking mechanism and door handle creating openings in the door. Additionally, the door is warped and does not close on its own.
74SOLAS(97 CONS) II-2/47.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 21 July 2023
Resolution: Door temporarily repaired and condition of class issued until new door can be procured and installed.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 20 July 2023
Resolved
Lighting in CO2 space was inoperable. Crew is unable to see emergency instructions without use of external light source.
SOLAS II-I/43.2.2.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2023
Resolution: Lighting repaired.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 20 July 2023
Resolved
Every ship… shall carry a garbage management plan, which the crew shall follow. PSCOs discovered cardboard stored in waste receptacle designated for oil-soaked rags in vicinity of ship's incinerator.
MARPOL V/10.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2023
Resolution: Cardboard removed from oily rag storage container.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 20 July 2023
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Areas where lifeboat and rescue boat rest against the davit are causing dents and scratches due to chocks being made of wood.
74SOLAS(97 CONS) III/19.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2023
Resolution: Rubber padding fitted to all points of contact between davit and lifeboats.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 July 2023
Resolved
Machinery… associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended… and the working conditions to which it will be subjected. Main engine cooling water line was observed to be leaking.
74SOLAS(97 CONS) II-I/26.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2023
Resolution: Class attested to repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 20 July 2023
Resolved
Satisfactory means in the form of guardrails… shall be provided for the protection of the crew in getting to and from…all other parts used in the necessary work of the ships. PSCOs discovered excessive wastage of railing in multiple areas on starboard side.
ILLC (66) Annex I /25.4
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2023
Resolution: Repairs conducted and documented via photo.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 20 July 2023
Resolved
The International Load Line Certificate… shall not be delivered to the ship until the officer or surveyor… has certified that the marks are correctly and permanently indicated on the ship's sides. After the survey of the ship, an additional load line marking was affixed to the side of the ship - causing the ship not to correspond with the issued ILLC.
ILLC (66) Annex I / 9
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2023
Resolution: New certificate issued.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 December 2022
Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship. PSCO observed fuel soaked rags under and around generators 1, 2, 3, and 4. PSCO observed oil soaked lagging on each generator.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2022
Resolved 14 December 2022
Resolution: received class report and attended vessel
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 December 2022
Resolved
In a ship in whcih oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship. PSCO observed oil soaked lagging and fuel soaked rags in the oil purifier room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2022
Resolved 14 December 2022
Resolution: received class report and attended vessel
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 December 2022
Resolved
Hydraulic power operated steering gear shall be provided with the following: A fixed storage tank having sufficient capacity to recharge at least one power actuating system. PSCO observed insufficient hydraulic oil in the reserve tank to fill one power actuating system.
74SOLAS(97)II-1/29.12.3
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 December 2022
Resolution: Ship's personnel filled reservior tank to 90%, .96 m3. Class attested to repairs.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 6 December 2022
Resolved
Main and emergency switchboards shall be so arranged as to give easy access as may be needed. PSCO observed stowage of spare parts behind switchboards in ECR and steering gear room.
74SOLAS(97)II-V 45.2
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 December 2022
Resolution: Ship's force removed boxes to a storage location. Class attested to repairs.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 December 2022
Resolved
In a ship in which oil fuel is used, the arrangements for the storage,distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship. PSCO observed saturated fuel lines on the #4 A/E.
74SOLAS(97)II-2 15.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2022
Resolution: All saturated fuel lines have been cleaned and renewed as necessary. Class attested to repairs
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 December 2022
Resolved
In a ship in which oil fuel is used, the arrangements for the storage,distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship. PSCO observed leaks and non-approved containments, and on the A/E and MDE fuel oil heater and transfer pumps.
74SOLAS(97)II-2 15.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2022
Resolution: All F/O catchments of A/E FO heaters, ME FO heaters, and FO transfer pumps have been cleaned, lagging changed and touched up. Class attested to repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 December 2022
Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed and installed as to withstand the maximum working stresses to which it may be subjected. PSCO observed major boiler water leak from level controller.
74SOLAS(97)II-1/33.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 December 2022
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 6 December 2022
Resolved
The company and the ship shall comply with the requirements of the ISM code. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations. PSCO observed collective operational deficiencies indicating a lack of ISM effectiveness, an internal safety audit is required within 90 days.
74SOLAS(20)IX/3.1
ISM code 10.1
Action required: 705 - Other - as specified
Resolved 23 February 2023
Resolution: Received and reviewed ISM audit, found satisfactory.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 6 December 2022
Resolved
A self-contained emergency source of electrical power shall be provided. PSCO observed the emergancy generator run for 30 seconds, then shut off.
74SOLAS(97)II-1/43.1
Action required: 10 - Deficiency Rectified
Resolved 7 December 2022
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 January 2019
Resolved
Internal combustion engines shall be provided with crankcase oil mist detectors or engine bearing temperature monitors or equivalent devices. Oil mist detector #1 was displaying a fault from the solenoid.
74 SOLAS (04) II-1/47.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 January 2019
Resolved 26 January 2019
Resolution: Chief Engineer cleaned solenoid and PSCO verified no faults were shown