MAURY USCG vessel records Sign in
← All vessels

SAUTE MOUTONS 5

SAUTE MOUTONS 5 is a 1993 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 1996, most recently in July 2019, along with 8 deficiencies.

Records from 1996 to 2019. Most recent: inspection, 8 July 2019.

Built
1993
Last inspected
8 July 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

444256
Flag
CANADA
—
Maury page id
psix-444256

Inspections, by type

…with no type recorded1
Years with a record 18 calendar years (1996–2019)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it15 - Simplified, Gross Ton
12 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 20

8 July 2019 Administrative Inspection · COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6743455
15 June 2018 COC-CVE Annual · Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6444851
6 June 2017 COC-CVE Annual · Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6167247
22 June 2016 COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5915665
15 May 2012 COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4306513
21 April 2009 COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3636980
9 May 2007 Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2959545
17 April 2007 COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2909591
18 April 2006 COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2626274
26 July 2005 COC-CVE Annual · Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2426300
20 July 2004 COC-CVE Annual
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2139024
28 July 2003 Certificate of Compliance
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1860268
8 August 2002 Certificate of Compliance
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1658316
13 August 2001 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1069001
10 August 2000 Control Verification
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1432368
20 August 1999 Control Verification
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1388901
24 April 1998 Control Verification
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1468440
8 July 1997 Control Verification
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1114612
9 May 1997 Control Verification
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1385981
23 July 1996 Control Verification
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1414669

Deficiency record · 8

Fire Fighting › Structural Fire Protection - General › Deckhouse Construction
Issued 17 April 2007 Resolved
Fill holes in deck where component connections pass from engine space. Engine room should be well sealed to prevent the release of extinguishing agent.
Action required: 705 - Other - as specified
Due 17 April 2007
Resolved 9 May 2007
Resolution: Witnessed satisfactory correction of penetrations to engine space.
Engineering › Fuel Oil Service System › Ventilation
Issued 17 April 2007 Resolved
Install fuel ventilation with 30x30 mesh omitted from new arrangement.
Action required: 705 - Other - as specified
Due 17 April 2007
Resolved 9 May 2007
Resolution: Witnessed installation of mesh.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 April 2007 Resolved
Replace retro reflective markings on buoys.
Action required: 705 - Other - as specified
Due 17 April 2007
Resolved 9 May 2007
Resolution: Witnessed renew of retro.
Engineering › Bilge Water Management System › Not Operational
Issued 26 July 2005 Resolved
Replace and properly mount high water alarm in engine space. (Identified wires not properly secured, switch installed with one screw vice two and interpretative switch). Scheduled follow-up visit 7/27/05 to demonstrate proper operation of system.
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 27 July 2005
Resolution: Attended vessel and witnessed satisfactory operation of system.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 26 July 2005 Resolved
Repair cracks identified in engine room; forward water tight bulkhead portside, number one port forward vertical stiffener at union of bottom longitudinal frame, and the number two port forward vertical stiffener at union of gusset and bottom longitudinal frame.
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 10 September 2005
Resolution: Received email confirmation of completion of requirement from operations manager.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 July 2005 Resolved
Within engine space electrical wires/cables, fuel hoses and hydraulic hoses requiring chaffing protection and supports to prevent damage as they pass through or over framing. Identified several lines where outer protective coating has been damaged requiring replacement. Inspect all lines and replace as necessary, properly apply protective material and properly secure as required.
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 10 September 2005
Resolution: Received email confirmation of completion of requirement from operations manager.
Fire Fighting › Ventilation Systems › Ducts
Issued 26 July 2005 Resolved
Fire damper required to seal compartment when closed by means of adequate pressure not allow free passage of extinguishing agent from engine space. (Recommended that mating surface be free from obstruction (bolts), attach gasket to surface and closing spring implemented. Also, compartment protected by fire extinguishing agent should be free of excessive penetration such as old bolt holes.
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 10 September 2005
Resolution: Received email confirmation of completion of requirement from operations manager.
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 26 July 2005 Resolved
Provide report from Transport Canada regarding the serviceability of vessel.
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 7 October 2005
Resolution: Received report form Transport Canada attesting to their examination of vessels and satisfactory completion of issued discrepancies.

Ownership record