MAURY USCG vessel records Sign in
← All vessels

ISLAND EXPRESS

ISLAND EXPRESS is a 1989 freight ship. The Coast Guard has recorded 38 inspections since 1996, most recently in May 2009, along with 31 deficiencies and 8 operational controls.

Records from 1996 to 2009. Most recent: inspection, 6 May 2009.

Built
1989
Last inspected
6 May 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8820949 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
444332
Flag
VANUATU
—
Maury page id
psix-444332

Inspections, by type

…with no type recorded22
Years with a record 10 calendar years (1996–2009)
The 38 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it3660 - Dead Weight, Ton
3113 - Convention (Subpart B), Gross Ton
3113 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 38

6 May 2009 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3468556
31 March 2004 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2038267
27 February 2004 Annual Inspection · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2014507
2 January 2004 Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1973293
21 December 2003 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2025475
16 December 2003 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1964989
25 November 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1954422
22 September 2003 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1910091
19 September 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1908456
4 September 2003 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1896686
1 September 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1902604
7 June 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1813809
28 April 2003 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1781879
11 April 2003 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1770989
7 February 2003 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1742201
10 September 2002 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1673754
14 August 2002 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1661405
2 May 2002 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1624836
31 January 2002 Ballast Water Examination · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1481617
17 January 2002 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1479693
3 January 2002 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1475799
6 September 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 293554
17 February 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 199891
17 February 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 287283
17 February 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 771223
7 October 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 38576
13 August 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 280885
5 February 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 274318
13 November 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 434900
18 March 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 426562
5 January 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 424223
10 July 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 417877
21 January 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 21616
2 January 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 506832
14 June 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 404540
22 December 1996 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 398669
30 September 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 395884
16 August 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 394209

Deficiency record · 31

Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 31 March 2004 Resolved
Fire control plan is faded and illegible. The plan's legand does not match the ships general arrangements. It is impossible to determine from plan which sections of the ship are enclosed by "A" class boundaries. Class or flag state must verify plan and approve that plan meets the requirements
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2004
Resolution: Recieved class report attesting to legible plan on board. The plan is only a copy, but the original will be sent to the ship asap.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 31 March 2004 Resolved
Numerous fire doors tied back, do not have self-closing devices, and/or do not latch shut.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2004
Resolution: Recieved class report from GL attesting to satisfactory operation of of all A class fire doors.
Documentation › Safety Management System
Issued 31 March 2004 Resolved
Objective evidence and vessels history indicates lack of planned maintainance on board vsl. Also documentation (non-conformities and corrective actions) not completed or closed out. Conduct external ISM audit prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2004
Resolution: DNV conducted audit which resulted in
Construction/Loadline › Structures
Issued 27 February 2004 Resolved
Replace dogs on door leading into storage space for flammable liquids, next to steering gear room, to the satitisfaction of Class. LEGACY COMPONENT DESC: Door
Due 27 March 2004
Resolved 31 March 2004
Resolution: dogs replaced and door operating satisfactorily.
Pollution Prevention/Response › Prevention Equipment
Issued 27 February 2004 Resolved
Prove proper operation of Oily Water separator, to the satisfaction of class, NLT 27Mar04 LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Due 27 March 2004
Resolved 31 March 2004
Resolution: USCG inspectors witnessed satisfactory test of OWS.
Fire Fighting › Nozzles
Issued 27 February 2004 Resolved
Replace the six (6) suicide nozzles with appropriate variable nozzles, to the satisfaction of USCG inspectors NLT 14Mar04 LEGACY COMPONENT DESC: Type
Due 14 March 2004
Resolved 31 March 2004
Resolution: new SOLas approved nozzles recieved 31 March while inspectors were on board.
Fire Fighting › Fire Hoses
Issued 27 February 2004 Resolved
Replace all leaking/wasted hoses to the satisfaction of USCG inspectors NLT 14Mar04. LEGACY COMPONENT DESC: Condition
Due 14 March 2004
Resolved 31 March 2004
Resolution: 7 hoses replaced and spares on board
Accommodation/Occupational Safety › Occupational Safety
Issued 27 February 2004 Resolved
Install covers on moving parts/belts on Main Diesel engine to the satisfaction of Class, NLT 27Mar04. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Due 27 March 2004
Resolved 31 March 2004
Resolution: inspected- sat
Engineering › Diesel Engine (propulsion-direct drive)
Issued 16 December 2003 Resolved
VESSEL #I CYLINDER ON MAIN PROPULSION ENGINE INOPERABLE. VESSEL SHALL MAKE REPAIRS AS NEW TO THE SATISFACTION OF CLASS/ FLAG PRIOR TO DEPARTURE. COAST GUARD MUST APPROVE CLASS REPORT PRIOR TO VESSEL DEPARTING. LEGACY COMPONENT DESC: Cylinder
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2003
Resolution: Germanischer lloyd issued a survey statement attesting to repairs to the No.1 engine repairs. Main engine No.1 unit injection pump and roller guide were renewed with original spare parts. Engine tested and considered repaired.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 25 November 2003 Resolved
Vessel developed problems with a main propulsion engine cylinder offshore, and entered port at 70% power (33 CFR 160.111): Provide class attestation of satisfactory repair and testing of main propulsion engine. LEGACY COMPONENT DESC: Cylinder
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 November 2003
Resolution: Received class (GL) report attesting to sat repairs & testing of MDE.
Engineering › Lubricating Oil Service System
Issued 4 September 2003 Resolved
EXCESSIVE AMOUNTS OF OIL ON BASE OF MAIN ENGINE, BILGE, AND OIL PURIFIER ROOM. SOLAS 74/78 II-1/26
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 22 September 2003
Resolution: VESSEL CLEANED EXCESSIVE OIL FROM ENGINE ROOM.
Engineering › Gas Turbine (propulsion/auxiliary-electric)
Issued 1 September 2003 Resolved
Vesssel suffer a loss of propulsion while attempting to depart the Port of Houston. Vessel restricted to port unitl repairs can be made.
Action required: 705 - Other - as specified
Due 1 September 2003
Resolved 1 September 2003
Resolution: Received report from class attesting to the proper operation of the vessel propulsion systems.
Electrical › Electrical Distribution System (service)
Issued 7 February 2003 Resolved
Ground detection panel lights and resistors disassembled or inoperative. LEGACY COMPONENT DESC: Ground Detection
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 11 April 2003
Resolution: received class report by fax
Electrical › Lighting (emergency)
Issued 7 February 2003 Resolved
Numerous deck lighting fixtures(service and emergency) wasted or inoperative. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 7 March 2003
Resolved 11 April 2003
Resolution: received class report by fax
Pollution Prevention/Response › Prevention Equipment
Issued 7 February 2003 Resolved
OWS inoperative. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 11 April 2003
Resolution: received class report by fax
Personnel › Certificates/Documents/Licenses
Issued 31 January 2002 Resolved
NOTED THAT MASTER, CHIEF MATE AND 2ND OFFICER DO NOT HAVE FLAG ENDORSEMENTS FOR STCW 95. AS OF AUG. 1, 2002 VSL MAY BE SUBJECT TO DETENTION ACTIONS IF CREW DOES NOT HAVE PROPER STCW 95 ENDORSEMENTS. LEGACY COMPONENT DESC: STCW Endorsement
Action required: 705 - Other - as specified
Due 1 August 2002
Resolved 14 August 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 31 January 2002 Resolved
NOTED CO2 ROOM TO BE WELDED SHUT TO PREVENT STOWAWAYS. VESSEL MAY SECURE CO2 ROOM, BUT METHOD MUST ALLOW READY ACCESS BY DESIGNATED OFFICER. LEGACY COMPONENT DESC: Operating Controls
Due 7 February 2002
Resolved 7 February 2002
Resolution: Crew removed weldments so that MI could inspect space. Removal took approximately 30 min''s.
Pollution Prevention/Response › Prevention Equipment
Issued 31 January 2002 Resolved
SENSOR FOR OWS IS INOPERATIVE. VESSEL CURRENTLY HAS SUFFICIENT CAPACITY TO HOLD SLUDGES. REPAIR OWS AS NEW, NO LATER THAN 28FEB02. CLASS TO ATTEST TO SATISFACTORY REPAIRS. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Due 28 February 2002
Resolved 2 May 2002
Resolution: Rcvd written confirmation from vessel''s master that OWS sensor is operating properly.
Fire Fighting › Ventilation Systems
Issued 31 January 2002 Resolved
REPAIR OR REPLACE MAIN VENTILATION DAMPNERS ON PORT AND STARBOARD SIDE. BOTH SIDES OBSERVED TO NOT FULLY CLOSE. HAND LEVERS ARE BROKEN. CLASS TO ATTEST TO CORRECTION LEGACY COMPONENT DESC: Operating Controls
Action required: 705 - Other - as specified
Due 28 February 2002
Resolved 2 May 2002
Resolution: Rcvd written confirmation from vessel''s master that main ventilation dampners are operating properly.
Navigation
Issued 13 November 1999 Resolved
charts are not up-dated to current notice to mariners. IAW 33 CFR 164.33_x001C_ up date charts no later than 13DEC99.
Condition: Unknown
Due 6 February 2000
Resolved 6 February 2000
Accommodation/Occupational Safety
Issued 18 March 1999 Resolved
RENEW/REPAIR AS ORIGINAL DETERIORATED SECTION OF SEWAGE PIPING IN ENGINEROOM. PWSA 33 USC 1223(b).
Condition: Unknown
Due 30 November 1999
Resolved 30 November 1999
Lifesaving
Issued 10 July 1998 Resolved
Rescue boat, required by Safety Equipment Certificate, not on board (sent ashore for repairs). Prior to departure, provide class report attesting tovessel's compliance with Safet Equipment Certificate IAW SOLAS 74/78 I/11.
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Deck/Cargo
Issued 16 August 1996 Resolved
Port side diesel bunkering connection missing flang and bolts IAW 33 CFR 156.130
Condition: Unknown
Due 17 August 1996
Resolved 20 August 1996
Documentation
Issued 16 August 1996 Resolved
SOPEP is missing emergency phone numbers IAW MARPOL 73/78 ANNEX 1/26._x001C_
Condition: Unknown
Due 18 August 1996
Resolved 20 August 1996
Documentation
Issued 16 August 1996 Resolved
Oil Transfer Procedures not written in a language understood by the crew IAW 33 CFR 155.740.
Condition: Unknown
Due 17 August 1996
Resolved 20 August 1996
Navigation
Issued 16 August 1996 Resolved
No Manuervering fact sheet on bridge IAW 33 CFR 164.35
Condition: Unknown
Due 18 August 1996
Resolved 20 August 1996
Navigation
Issued 16 August 1996 Resolved
Gyro compass not operable due to bad sphere IAW 33 CFR 164.35.
Condition: Unknown
Due 18 August 1996
Resolved 20 August 1996
Lifesaving
Issued 16 August 1996 Resolved
EPIRB not onboard during inspection, servicing being conducted to enter newvessel call sign.
Condition: Unknown
Due 18 August 1996
Resolved 20 August 1996
Electrical
Issued 16 August 1996 Resolved
Emergency generator space is missing non conductive mat in space IAW SOLAS 74.
Condition: Unknown
Due 16 September 1996
Resolved 20 August 1996
Navigation
Issued 16 August 1996 Resolved
Loadline not painted a contrasting color IAW ILLC 66.
Condition: Unknown
Due 16 September 1996
Resolved 20 August 1996
Construction/Loadline
Issued 16 August 1996 Resolved
Port side ballast discharge aft has a broken weld IAW SOLAS 74 CH II-1 REG 25-10.
Condition: Unknown
Due 1 October 1996
Resolved 1 October 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.