ISLAND EXPRESS is a 1989 freight ship. The Coast Guard has recorded 38 inspections since 1996, most recently in May 2009, along with 31 deficiencies and 8 operational controls.
Records from 1996 to 2009. Most recent: inspection, 6 May 2009.
- Built
- 1989
- Last inspected
- 6 May 2009
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 31 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8820949 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V2PV
444332
Flag
VANUATU
—
Maury page id
psix-444332
Inspections, by type
…with no type recorded22
Years with a record
10 calendar years (1996–2009)
The 38 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it3660 - Dead Weight, Ton
3113 - Convention (Subpart B), Gross Ton
3113 - Regulatory (Subpart C or D), Gross Ton
3113 - Convention (Subpart B), Gross Ton
3113 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 38
6 May 2009
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3468556
31 March 2004
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2038267
27 February 2004
Annual Inspection · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2014507
2 January 2004
Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1973293
21 December 2003
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2025475
16 December 2003
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1964989
25 November 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1954422
22 September 2003
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1910091
19 September 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1908456
4 September 2003
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1896686
1 September 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1902604
7 June 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1813809
28 April 2003
Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1781879
11 April 2003
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1770989
7 February 2003
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1742201
10 September 2002
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1673754
14 August 2002
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1661405
2 May 2002
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1624836
31 January 2002
Ballast Water Examination · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1481617
17 January 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1479693
3 January 2002
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1475799
6 September 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 293554
17 February 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 199891
17 February 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 287283
17 February 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 771223
7 October 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 38576
13 August 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 280885
5 February 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 274318
13 November 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 434900
18 March 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 426562
5 January 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 424223
10 July 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 417877
21 January 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 21616
2 January 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 506832
14 June 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 404540
22 December 1996
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 398669
30 September 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 395884
16 August 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 394209
Deficiency record · 31
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 31 March 2004
Resolved
Fire control plan is faded and illegible. The plan's legand does not match the ships general arrangements. It is impossible to determine from plan which sections of the ship are enclosed by "A" class boundaries. Class or flag state must verify plan and approve that plan meets the requirements
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 31 March 2004
Resolved
Numerous fire doors tied back, do not have self-closing devices, and/or do not latch shut.
Documentation › Safety Management System
Issued 31 March 2004
Resolved
Objective evidence and vessels history indicates lack of planned maintainance on board vsl. Also documentation (non-conformities and corrective actions) not completed or closed out. Conduct external ISM audit prior to departure.
Construction/Loadline › Structures
Issued 27 February 2004
Resolved
Replace dogs on door leading into storage space for flammable liquids, next to steering gear room, to the satitisfaction of Class. LEGACY COMPONENT DESC: Door
Pollution Prevention/Response › Prevention Equipment
Issued 27 February 2004
Resolved
Prove proper operation of Oily Water separator, to the satisfaction of class, NLT 27Mar04 LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Fire Fighting › Nozzles
Issued 27 February 2004
Resolved
Replace the six (6) suicide nozzles with appropriate variable nozzles, to the satisfaction of USCG inspectors NLT 14Mar04 LEGACY COMPONENT DESC: Type
Fire Fighting › Fire Hoses
Issued 27 February 2004
Resolved
Replace all leaking/wasted hoses to the satisfaction of USCG inspectors NLT 14Mar04. LEGACY COMPONENT DESC: Condition
Accommodation/Occupational Safety › Occupational Safety
Issued 27 February 2004
Resolved
Install covers on moving parts/belts on Main Diesel engine to the satisfaction of Class, NLT 27Mar04. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Engineering › Diesel Engine (propulsion-direct drive)
Issued 16 December 2003
Resolved
VESSEL #I CYLINDER ON MAIN PROPULSION ENGINE INOPERABLE. VESSEL SHALL MAKE REPAIRS AS NEW TO THE SATISFACTION OF CLASS/ FLAG PRIOR TO DEPARTURE. COAST GUARD MUST APPROVE CLASS REPORT PRIOR TO VESSEL DEPARTING. LEGACY COMPONENT DESC: Cylinder
Engineering › Diesel Engine (propulsion-direct drive)
Issued 25 November 2003
Resolved
Vessel developed problems with a main propulsion engine cylinder offshore, and entered port at 70% power (33 CFR 160.111): Provide class attestation of satisfactory repair and testing of main propulsion engine. LEGACY COMPONENT DESC: Cylinder
Engineering › Lubricating Oil Service System
Issued 4 September 2003
Resolved
EXCESSIVE AMOUNTS OF OIL ON BASE OF MAIN ENGINE, BILGE, AND OIL PURIFIER ROOM. SOLAS 74/78 II-1/26
Engineering › Gas Turbine (propulsion/auxiliary-electric)
Issued 1 September 2003
Resolved
Vesssel suffer a loss of propulsion while attempting to depart the Port of Houston. Vessel restricted to port unitl repairs can be made.
Electrical › Electrical Distribution System (service)
Issued 7 February 2003
Resolved
Ground detection panel lights and resistors disassembled or inoperative. LEGACY COMPONENT DESC: Ground Detection
Electrical › Lighting (emergency)
Issued 7 February 2003
Resolved
Numerous deck lighting fixtures(service and emergency) wasted or inoperative. LEGACY COMPONENT DESC: Lighting Fixture
Pollution Prevention/Response › Prevention Equipment
Issued 7 February 2003
Resolved
OWS inoperative. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Personnel › Certificates/Documents/Licenses
Issued 31 January 2002
Resolved
NOTED THAT MASTER, CHIEF MATE AND 2ND OFFICER DO NOT HAVE FLAG ENDORSEMENTS FOR STCW 95. AS OF AUG. 1, 2002 VSL MAY BE SUBJECT TO DETENTION ACTIONS IF CREW DOES NOT HAVE PROPER STCW 95 ENDORSEMENTS. LEGACY COMPONENT DESC: STCW Endorsement
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 31 January 2002
Resolved
NOTED CO2 ROOM TO BE WELDED SHUT TO PREVENT STOWAWAYS. VESSEL MAY SECURE CO2 ROOM, BUT METHOD MUST ALLOW READY ACCESS BY DESIGNATED OFFICER. LEGACY COMPONENT DESC: Operating Controls
Pollution Prevention/Response › Prevention Equipment
Issued 31 January 2002
Resolved
SENSOR FOR OWS IS INOPERATIVE. VESSEL CURRENTLY HAS SUFFICIENT CAPACITY TO HOLD SLUDGES. REPAIR OWS AS NEW, NO LATER THAN 28FEB02. CLASS TO ATTEST TO SATISFACTORY REPAIRS. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Fire Fighting › Ventilation Systems
Issued 31 January 2002
Resolved
REPAIR OR REPLACE MAIN VENTILATION DAMPNERS ON PORT AND STARBOARD SIDE. BOTH SIDES OBSERVED TO NOT FULLY CLOSE. HAND LEVERS ARE BROKEN. CLASS TO ATTEST TO CORRECTION LEGACY COMPONENT DESC: Operating Controls
Navigation
Issued 13 November 1999
Resolved
charts are not up-dated to current notice to mariners. IAW 33 CFR 164.33_x001C_ up date charts no later than 13DEC99.
Accommodation/Occupational Safety
Issued 18 March 1999
Resolved
RENEW/REPAIR AS ORIGINAL DETERIORATED SECTION OF SEWAGE PIPING IN ENGINEROOM. PWSA 33 USC 1223(b).
Lifesaving
Issued 10 July 1998
Resolved
Rescue boat, required by Safety Equipment Certificate, not on board (sent ashore for repairs). Prior to departure, provide class report attesting tovessel's compliance with Safet Equipment Certificate IAW SOLAS 74/78 I/11.
Deck/Cargo
Issued 16 August 1996
Resolved
Port side diesel bunkering connection missing flang and bolts IAW 33 CFR 156.130
Documentation
Issued 16 August 1996
Resolved
SOPEP is missing emergency phone numbers IAW MARPOL 73/78 ANNEX 1/26._x001C_
Documentation
Issued 16 August 1996
Resolved
Oil Transfer Procedures not written in a language understood by the crew IAW 33 CFR 155.740.
Navigation
Issued 16 August 1996
Resolved
No Manuervering fact sheet on bridge IAW 33 CFR 164.35
Navigation
Issued 16 August 1996
Resolved
Gyro compass not operable due to bad sphere IAW 33 CFR 164.35.
Lifesaving
Issued 16 August 1996
Resolved
EPIRB not onboard during inspection, servicing being conducted to enter newvessel call sign.
Electrical
Issued 16 August 1996
Resolved
Emergency generator space is missing non conductive mat in space IAW SOLAS 74.
Navigation
Issued 16 August 1996
Resolved
Loadline not painted a contrasting color IAW ILLC 66.
Construction/Loadline
Issued 16 August 1996
Resolved
Port side ballast discharge aft has a broken weld IAW SOLAS 74 CH II-1 REG 25-10.