Records from 1982 to 2001. Most recent: inspection, 25 January 2001.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 25
25 January 2001
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1057140
31 December 1998
COI Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1458574
4 March 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 784227
16 December 1997
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1392823
23 October 1997
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1441306
12 September 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1116631
13 March 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1105224
23 January 1997
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1425875
5 November 1996
Permit to Proceed
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1101215
16 October 1996
Hull Examination · Drydock Extension · Deficiency Check · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1409578
14 April 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1078010
6 October 1993
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1362854
19 November 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 829358
15 July 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 936751
18 October 1991
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 940305
9 September 1991
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 935833
26 April 1991
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1306895
15 June 1989
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1032065
27 March 1989
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1202059
20 December 1988
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1033665
29 March 1988
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 990296
12 August 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 998585
22 July 1986
Credit Drydock
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1300270
17 June 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1288831
8 December 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 969901
Construction/Loadline
Issued 16 October 1996
Resolved
REPLACE WASTED SIDESHELL STIFFENERS IN #1 MAINDECK DRY CARGO HOLD.
Condition: Unknown
Due 16 November 1996
Resolved 23 January 1997
Lifesaving
Issued 16 October 1996
Resolved
MAKE IMMERSIONS READY FOR INSPECTION.
Condition: Unknown
Due 16 October 1996
Resolved 16 October 1996
Engineering
Issued 16 October 1996
Resolved
REPAIR OR REPLACE SUPERHEATER DRAIN VALVE ON PORT BOILER.
Condition: Unknown
Due 16 November 1996
Resolved 23 January 1997
Construction/Loadline
Issued 16 October 1996
Resolved
REPLACE WASTED VENTS TO #1 & #2 DEEP TANKS.
Condition: Unknown
Due 16 November 1996
Resolved 23 January 1997
Documentation
Issued 16 October 1996
Resolved
REVISE & RESUBMIT TO MSO PORT ARTHUR FOR APPROVAL FIRE CONTROL PLAN.
Condition: Unknown
Due 16 October 1996
Resolved 16 October 1996
Engineering
Issued 16 October 1996
Resolved
REPAIR OR REPLACE RELIEF VALVE FOR THE ATMOSPHERIC EXHAUST.
Condition: Unknown
Due 16 November 1996
Resolved 23 January 1997
Lifesaving
Issued 6 October 1993
Resolved
PROVE PROPER OPERATION OF FLEMMING GEAR IN BOTH LIFEBOATS.
Condition: Unknown
Due 6 October 1993
Resolved 6 October 1993
Fire Fighting
Issued 6 October 1993
Resolved
PROVE PROPER OPERATION OF MAIN FIRE PUMP.
Condition: Unknown
Due 14 October 1993
Resolved 12 October 1993
Documentation
Issued 6 October 1993
Resolved
PROVIDE COPY OF MANUEVERING CHARACTERISTICS FOR BRIDGE.
Condition: Unknown
Due 18 October 1993
Resolved 18 October 1993
Construction/Loadline
Issued 18 October 1991
Resolved
VESSEL WAS BOARDED ON 18OCT91 TO INSPECT THE RECENT FAN ROOM MODIFICATION. OPENINGS IN THE DECK WITHIN THE SUPPLY VENT FAN ROOM INTO VARIOUS ACCOMO- DATION SPACES BELOW WERE NOTED. THIS IS IN CONFLICT WITH 46 CFR 92.07 AS THE DECK IS NO LONGER STEEL OR EQUIVALENT. RESTORE DECK AS ORIGINAL.
Condition: Unknown
Due 18 October 1991
Resolved 18 October 1991
Construction/Loadline
Issued 18 October 1991
Resolved
SUBMIT PLANS OF PROPOSED SUPPLY VENT FAN ROOM MODIFICATIONS TO COMMANDANT (G-MSC) FOR APPROVAL. PRIOR TO VESSELS FUTURE ACTIVATION MODIFICATIONS TO DECK IN THE SUPPLY VENT FAN ROOM MUST BE RESTORED TO ORIGINAL OR APPROVED BY (G-MSC).
Condition: Unknown
Due 18 October 1991
Resolved 18 October 1991
Engineering
Issued 9 September 1991
Resolved
RESET AND SEAL BOILER SAFETIES BELOW MAWP PRIOR TO ACTIVATION OF VESSEL OR USE OF BOILERS._x001C_
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Navigation
Issued 9 September 1991
Resolved
MAKE PERMANENT REPAIRS TO THE PORT HYDRAULIC REPLENISHMENT PUMP.
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Documentation
Issued 26 April 1991
Resolved
COMPLETE INSPECTION FOR CERTIFICATION IN ACCORDANCE WITH MARAD/USCG MOU DTD10JUL89 AND 46 CFR 91.01-1. CURRENT COI EXPIRED 27MAR91.
Condition: Unknown
Due 26 April 1991
Resolved 26 April 1991
Engineering
Issued 26 April 1991
Resolved
REPAIR/REPLACE ALL WASTED BOILER SUPPORT FRAMES LOCATED DIRECTLY BENEATH PORT AND STARBOARD BOILERS. ITEMS SHALL BE COMPLETED PRIOR TO REACTIVATION.
Condition: Unknown
Due 26 April 1991
Resolved 26 April 1991
Engineering
Issued 26 April 1991
Resolved
REPAIR/REPLACE ALL WASTED PIPE SUPPORTS (HANGERS) LOCATED IN LOWER LEVEL OFENGINEROOM IN WAY OF BOILER SUPPORTS. ITEMS SHALL BE COMPLETED PRIOR TO REACTIVATION.
Condition: Unknown
Due 26 April 1991
Resolved 26 April 1991