11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 June 2024
Resolved
Lifering light was found with expired battery. Replace as required.
Action required: 10 - Deficiency Rectified
Due 5 June 2024
Resolved 5 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 June 2024
Resolved
Lifering light lanyard was severed. Replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 June 2024
Resolved
Life ring was not labeled. Label life ring with vessel name and hailing port as requiired
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 June 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 June 2024
Resolved
Proof was not available showing active membership in the PVA in order to validate security plan administration.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 June 2024
Resolved
Remove possible obstruction and ensure proper operation of port propulsion prior to operation.
Action required: 705 - Other - as specified
Resolved 7 June 2024
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 30 May 2023
Resolved
Buckets were found in engine room full of rags and from
port and starboard engine crankcase breather tubes. Remove oil and limit future collection of pooled oil from machinery space to prevent fire hazards
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 July 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 May 2023
Resolved
All batteries were found uncovered. Ensure all battery boxes are covered and secured.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 July 2023
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 30 May 2023
Resolved
Emergency lighting fixture in engine room was found to be missing bulb and protective globe. Repair lighting fixture.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 July 2023
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 30 May 2023
Resolved
Rudder angle indicator on operating station was inoperable. Repair or replace rudder angle indicator.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 July 2023
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 30 May 2023
Resolved
Magnetic compass found with no means to illuminate. Repair or replace magnetic compass light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 July 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 May 2023
Resolved
Copper wire on battery switch for starboard generator was exposed. Repair or replace copper wire.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 July 2023
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 30 May 2023
Resolved
Sections of fire boundary insulation were found damaged or missing, repair overhead insulation in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 July 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 May 2022
Resolved
Markings- Life jacket box marking should be displayed to reflect an accurate count of PFD's stored inside. Vessel owner/operator shall correct the labeling on the side of the storage box to reflect an accurate count.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2022
Resolved 4 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 May 2022
Resolved
Lifesaving- One child size lifejacket was found deteriorated and not for fit for service. The PFD was replaced with another spare life jacket from the supply office on shore.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 May 2022
Resolved 4 May 2022
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 3 May 2022
Resolved
The employer shall provide an Employee Assistance Program (EAP) for all crewmembers. Information regarding the EAP must be made available and displayed in a place where visible to all crewmembers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2022
Resolved 18 May 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2022
Resolved
Deteriorated outlet cover found on the upper deck fwd bulkhead. All electrical installations shall be done in a manner to protect passengers, crew, other persons, and the vessel from electrical hazards.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2022
Resolved 3 June 2022
Resolution: Supplied MI with photo documentation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2022
Resolved
Vessels secondary generator wiring harness was found chaffed and deteriorated. Vessel owner shall repair or replace harness to ensure all services necessary for safety under normal and emergency conditions are met.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2022
Resolved 18 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 May 2022
Resolved
Guard covering the spline for the vessels bilge pump was missing, causing a hazard around the rotating machinery. Vessel owner/operator shall replace the guard to ensure their is no longer exposed hazards.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2022
Resolved 18 May 2022
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 May 2022
Resolved
Vessels stern light was not operational. All vessels must have navigation lights that are in compliance with the International and Inland Navigation Rules. Repair or replace to light to ensure compliance. (Recifty prior to movement during nighttime operations or during reduced visibitly)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2022
Resolved 18 May 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 May 2022
Resolved
The fire extinguisher in the galley space was not secured in the proper bracket. Replace bracket with manufacturer specified bracket to ensure proper stowage.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2022
Resolved 3 June 2022
Resolution: Provided MI with photo Documentation of repair.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 9 August 2021
Resolved
Marine Employers shall establish programs for the chemical testing of dangerous drugs on a random basis. If an individual who does not hold a credential fails a chemical test for dangerous drugs, the individual shall be denied employment as a crewmember or removed from duties which directly affect the safe operation of the vessel as soon as possible.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 September 2021
Resolved 9 August 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 August 2021
Resolved
Life jacket box marking should be displayed to reflect an accurate count of PFD's stored inside. Vessel owner/operator shall correct the labeling on the side of the storage box to reflect an accurate count.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 September 2021
Resolved 9 August 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 August 2021
Resolved
One child size lifejacket was found deteriorated and not for fit for service. The PFD was replaced with another spare life jacket from the supply office on shore.
Action required: 10 - Deficiency Rectified
Due 9 September 2021
Resolved 9 August 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 August 2021
Resolved
Random drug test result was mistakenly labeled positive due to a legal prescription drug. MRO was contacted and provided appropriate documentation to reevaluate the specimine to determine it was a negative test.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2021
Resolved 9 August 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 September 2020
Resolved
Remove toggle switch and dead end wires from under bridge operating station.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2020
Resolved 2 November 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 September 2020
Resolved
Repair/replace stern navigation light.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2020
Resolved 2 November 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 September 2020
Resolved
Service or replace fire extinquisher on the upper deck.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2020
Resolved 2 November 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 September 2020
Resolved
Repair cable at 12 volt service distribution panel in engine room hatch closet.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2020
Resolved 2 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 September 2020
Resolved
Tighten or repair shaft packing on port side to prevent leaking and provide for proper operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2020
Resolved 2 November 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 September 2020
Resolved
Install proper guards on engine room lights.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2020
Resolved 2 November 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 July 2020
Resolved
Remove temporary fluorescent light fixture from engine room.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2020
Resolved 2 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 23 July 2020
Resolved
Repair tempurature guage wire on starboard engine.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2020
Resolved 2 November 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 July 2019
Resolved
No marine employer shall engage or employ any individual
to serve as a crew-member unless the individual passes a
chemical test for dangerous drugs for that employer.
There are currently three individuals that are working
as deckhands that have not successfully passed a drug
screening. These individuals must be taken out of that
role immediately until test results are back from the
lab. Provide test results to Coast Guard within 30
days.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2019
Resolved 31 July 2019
Resolution: The owner provided pre-employment tests for all employees working as deckhands.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 July 2019
Resolved
Marine employers shall establish programs for the
chemical testing for dangerous drugs on a random basis
of crew members on inspected vessels who are
specifically assigned the duties of warning, mustering,
assembling, assisting, or controlling the movement of
passengers during emergencies. There are currently
several employees assigned the above duties. They must
be immediately removed from that role until successfully
enrolled in the drug testing program and a preemployment
test is preformed. Provide proof of enrollment and test
results to Coast Guard within 30 days.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2019
Resolved 31 July 2019
Resolution: The owner provided pre-employment test for all employees that will be performing in a safety position.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 17 July 2019
Resolved
The stability letter must be posted under glass in the
pilot house. The stability letter was not posted for
inspection. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 17 July 2019
Resolved 17 July 2019
Resolution: The stability letter was posted before inspection was completed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 July 2019
Resolved
The vessels engine room bilge was found with excessive
oil in the bilge and on the starboard engine head.
Cleared on the spot.
Action required: 10 - Deficiency Rectified
Due 17 July 2019
Resolved 17 July 2019
Resolution: The engine room bilge and engine was cleaned prior to end of inspection.
01 - Certificates & Documentation › 012 - Crew Certificates › Training and qualification MLC - Personnel safety training
Issued 17 July 2019
Resolved
The owner, charterer, master or managing operator shall
instruct each crew member, upon first being employed and
prior to getting underway for the first time on a
particular vessel and at least once every three months,
as to the duties that the crew member is expected to
perform in an emergency. All crew members with access to
the engine room need to be trained on procedures for
using the bilge pumps. Provide proof of training within
14 days.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2019
Resolved 31 July 2019
Resolution: The captain of the vessel provided training to all crew on how to use the bilge pumps in case of an emergency.
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 7 May 2019
Resolved
The currently installed fixed fire extinguishing system is not functioning properly. The installed system is designed with a 20 second time delay and during the annual test of the system, the time-delay went off at 16 seconds. The system needs to be corrected and tested to the satisfaction of a Coast Guard Marine inspector within 14 days. Until this is completed, the owner will implement a plan to ensure that no one is in the engine room during a trip and that there are procedures in place to ensure no one is in the space prior to initiating the CO2 system.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2019
Resolved 14 May 2019
Resolution: Cleared to the satisfaction of the Coast Guard Marine Inspector.
Navigation › Piloting/Steering › Marine Charts
Issued 14 May 2018
Resolved
As appropriate for the intended voyage, a vessel must
carry adequate and up-to-date charts of large enough
scale to make safe navigation possible. On board charts
were not for navigational use. Vessel must obtain proper
charts for areas navigated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 June 2018
Resolution: SAT Chart provided
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 May 2018
Resolved
All vessels must have navigation lights that are in
compliance with the applicable sections of the
International and Inland Navigation Rules. Stern light
was intermittently operational. Make stern light fully
operational.
Action required: 10 - Deficiency Rectified
Resolved 14 May 2018
Resolution: Replaced bulb
Engineering › Steering Gear System › Rudder
Issued 14 May 2018
Resolved
Strong and effective structural rudder stops must be
fitted. Port rudder stop is inadequate. Make rudder stop
satisfactory as to not damage steering.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2018
Resolved 19 June 2018
Resolution: Attended vessel to witness newly welded rudder stops in place and verified operation.
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 14 May 2018
Resolved
Port engines raw water pump loosing prime. Repair,
replace components as needed to make raw water pump
satisfactory as to manufacturer specifications for
engine and/or pump.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2018
Resolved 19 June 2018
Resolution: Vessel O/O installed new raw water pump, which was tested and verified by attending marine inspector.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 25 April 2017
Resolved
Renew required marking on 01 deck ring buoy.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Buoy marked as required.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 25 April 2017
Resolved
Renew gasket for void #2 hatch.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Gasket replaced and witnesses sat ops of hatch.
Engineering › Bilge Water Management System › Valve
Issued 25 April 2017
Resolved
Demonstrate proper operation of all bilge system check valves.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Witnessed sat ops of all bilge system check valves.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 25 April 2017
Resolved
Renew gasket for engine room hatch.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Witness new gasket installed and sat ops of hatch.
Electrical › Electric Generation Source (service) › Generator
Issued 25 April 2017
Resolved
Prove proper operation of port generator and correct leaking oil line port side of engine.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Witnessed sat operation; shut down and replaced hose w/ clamp correcting leak.
Electrical › Electric Supply System (service) › Cable
Issued 25 April 2017
Resolved
Provide chaffing gear & support port main battery cables (under engine).
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Witnessed appropriate supports and protection.
Electrical › Electrical Distribution System (service) › Cable
Issued 25 April 2017
Resolved
Properly secure battery cable to port forward installation and clear starboard.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Witnessed proper securing nut for port and maintenance completed on port installation.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 25 April 2017
Resolved
Adjust engine room ventilation to ensure port after closes.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Witnessed sat operation of ventilation dampers.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 31 May 2016
Resolved
De-water all spaces & maintain dry & free of oil. Verification by Masters required prior to each daily operation. Entry in vessels log shall be completed. Provide complete copy of VGP appendix K.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 June 2016
Resolved 17 June 2016
Resolution: Attended vessel finding all bilges clean and dry.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 31 May 2016
Resolved
Provide annual servicing record for portable & fixed fire extinguishers.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 1 June 2016
Resolution: Servicing report provided.
Engineering › Bilge Water Management System › Valve
Issued 31 May 2016
Resolved
Provide check valve/strainer for steering compartment.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 31 May 2016
Resolution: Check valve strainer found on deck & replaced during inspection.
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 31 May 2016
Resolved
Identify & correct excessive oil leaks from main diesel engines.
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 17 June 2016
Resolution: Attended vessel with tech aboard finding no excessive oil leaks from engine. Bucket for crank case breather covered to prevent spraying from normal operations. Bilges found clean and dry.
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 May 2016
Resolved
Correctly wire port main diesel engine controlling & monitoring components.
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 17 June 2016
Resolution: Wires shorted and properly routed/secured.
Electrical › Electric Supply System (service) › Battery Installation
Issued 31 May 2016
Resolved
Secure battery box covers.
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 17 June 2016
Resolution: All battery box covers installed and secured.
Construction/Loadline › Hull › Transverse Frame
Issued 31 May 2016
Resolved
Repair cracked transverse frame in liquor void space starboard side of keel from repair completed during 2015/16 hull exam.
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 25 April 2017
Resolution: Witnessed sat repair of structural member.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 31 May 2016
Resolved
DAPI Audit; Provide contract with First Advantage.
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 17 June 2016
Resolution: Contract provided attesting to enrollment for the 2016 operating season with updated list of employees.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 31 May 2016
Resolved
DAPI Audit; Provide evidence of MIS submitted to the U. S. C. G by March 15, 2016.
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 17 June 2016
Resolution: Copy of the 2015 MIS provided.
Electrical › Lighting (service) › Lighting Fixture
Issued 31 May 2016
Resolved
Remove portable lighting fixture & extension cords from the engine room.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 17 June 2016
Resolution: All portable lighting & extension cords removed.
Engineering › Freshwater System (cylinder head cooling) › Suction Strainer
Issued 31 May 2016
Resolved
Repair or replace leaking clear bowl strainer installed forward of starboard main. If replaced new must be UL approved.
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 17 June 2016
Resolution: Installation seal cleaned and re-installed with no leaks.