Records from 2007 to 2024. Most recent: inspection, 8 August 2024.
Inspection history · 20
8 August 2024
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7977397
5 August 2023
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7778903
1 August 2023
Annual Inspection · DAPI Audit
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7758686
9 May 2023
Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7645706
13 August 2022
Examination of Repairs · Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7532492
13 August 2022
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7532683
9 June 2022
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7473847
22 April 2021
COI Inspection · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7180382
8 August 2019
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6789547
2 July 2019
Type not recorded
No type recorded · Station Yaquina Bay · USCG Northwest District (CGD-NW) · Activity 6734136
19 April 2019
Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6685497
13 October 2018
Type not recorded
No type recorded · Station Yaquina Bay · USCG Northwest District (CGD-NW) · Activity 6560903
13 October 2018
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6562363
13 October 2018
Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6563096
6 September 2018
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6535261
4 May 2018
Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6410137
28 March 2017
COI Inspection · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6113285
4 October 2016
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6015594
24 September 2016
Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6009676
2 May 2016
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5867263
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 June 2022
Resolved
Checking of each cylinder containing compressed gas to ensure it has been tested and marked in accordance with 46 CFR 147.60. Inspected Fireboy and operation checks normal with overide without any discrepancies. Missing inspection date on the Fixed fire fighting system and could not provide inspection report. Owner must provide proof of annual inspection of the fixed fire fighting system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2022
Resolved 27 June 2022
Resolution: RCVD inspection report from C&S Fire Safe Services that all FF equipment passed inspection.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 9 June 2022
Resolved
Protect passengers, crew, other persons, and the vessel, from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. In the machinery space, found multiple loose electrical wires with one end terminated. Electrical wiring must be properly terminated on both end to ensure safety of passengers, crew, other personnels, and the vessel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2022
Resolved 29 August 2022
Resolution: Master provided a report attesting to rectification of loose wires. No loose wires observed during deficiency check inspection.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 May 2021
Resolved
A pre-engineered fixed gas fire extinguishing system must: ... (3) automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space.
When tested, the installed system failed to shut down the main diesel engine and showed as "discharged" on the gauge.
Demonstrate proper operation of the installed and verification that the system is charged to the attending marine inspector prior to the carriage of passengers/cargo.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2021
Resolved 9 June 2022
Resolution: As per Activity #7473847, pre-engineered fixed fire system operated properly. Based on unit records, there may have been a def-check exam during May, 2021, to clear this deficiency, that was not properly captured in MISLE. Cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 May 2021
Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Strainers must be leak free. Strainers must be the type of opening on top for cleaning screens. A drip pan fitted with flame screen must be installed under gasoline strainers. Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock. Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Approval of bowls of other than steel construction will specify if a flame shield is required.
A fuel filter was identified in the engine compartment without the required metal bowl and associated hardware.
Install the appropriate metal bowl per manufacturer instructions and provide evidence to the attending marine inspector.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2021
Resolved 29 August 2022
Resolution: Vessel installed new Racor system IAW manufacturer's directions.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 4 May 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2021
Resolved 6 September 2022
Resolution: Vessel master produced evidence of Marine Radio operator Permit and Owner submitted evidence of FCC Station License, confirmed via FCC online database.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 19 April 2019
Resolved
Repair to vapor tight condition, penetration made in forward engine room bulkhead.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2019
Resolved 26 April 2019
Resolution: Bulkhead made vapor tight.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 19 April 2019
Resolved
Provide positive stop valve on wash-down system through hull penetration.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2019
Resolved 26 April 2019
Resolution: System line removed and permanent cap installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 October 2018
Resolved
Troubleshoot and make permanent repairs to vessels main engine in regards to loss of propulsion on 13OCT2018. Repairs to be to the satisfaction to the attending marine inspector, prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2018
Resolved 18 October 2018
Resolution: Vessel made repairs to cooling jacket water hoses and clamps. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 October 2018
Resolved
Repair and extinguish exhaust leaking into engine room, to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2018
Resolved 18 October 2018
Resolution: Repairs made to crank case breather line, all sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 6 September 2018
Resolved
Provide FCC operators permit for Master of the vessel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2018
Resolved 4 May 2021
Resolution: Cleared and re-issued new CG835 to the current owner.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 September 2018
Resolved
Provide FCC Safty Certificate
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2018
Resolved 4 May 2021
Resolution: Cleared and re-issued new CG835 to the current owner.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 September 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2018
Resolved 4 May 2021
Resolution: Cleared and re-issued new CG835 to the current owner.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 4 May 2018
Resolved
Test and make permanent repairs to starboard fuel oil tank. Repairs and testing are to be completed to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2018
Resolved 15 May 2018
Resolution: Vessel installed new approved tank this date.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 11 May 2017
Resolved
Service IBA by 31 May, 2017
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 22 June 2017
Resolution: Verified IBA was serviced.
Lifesaving › Inflatable Buoyant Apparatus › Weak Link
Issued 11 May 2017
Resolved
Replace HRU for IBA by 31 May 2017
Due 31 May 2017
Resolved 22 June 2017
Resolution: Verified HRU replaced.
Communications › Alarms/Indicators › Bilge Alarm
Issued 11 May 2017
Resolved
Demonstrate proper operation of engine room bilge alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2017
Resolved 12 May 2017
Engineering › Bilge Water Management System › Pump
Issued 11 May 2017
Resolved
Demonstrate proper operation of auto bilge pump run indicator light in laz.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2017
Resolved 12 May 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 May 2017
Resolved
Provide lanyard for waterlight on lifering.
Action required: 705 - Other - as specified
Due 11 June 2017
Resolved 12 May 2017
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 11 May 2017
Resolved
Replace remote pull cable for fixed fire extinquisher system in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2017
Resolved 12 May 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 24 September 2016
Resolved
MAKE REPAIRS TO MAIN PROPULSION ENGINE, AND DEMONSTRATE PROPER OPERATION IN ALL RANGES OF OPERATION TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. PROVIDE SERVICE TECH REPORT ON FINDINGS OF ENGINE FAILURE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2016
Resolved 11 May 2017
Resolution: New engine installed and witnessed proper operation this day.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 2 May 2016
Resolved
The aluminum MSD holding tank exhibited signs of severe corrosion and potential leaks.
Condition: Improper Installation
Due 4 June 2016
Resolved 11 May 2017