MAURY USCG vessel records
← All vessels

MURCIA CARRIER

MURCIA CARRIER is a 1996 freight ship. The Coast Guard has recorded 37 inspections since 2016, most recently in June 2025, along with 6 deficiencies and 5 operational controls.

Records from 2016 to 2025. Most recent: inspection, 22 June 2025.

Built
1996
Last inspected
22 June 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 June 2025
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9063665
V7A4911
444545
Flag
MARSHALL ISLANDS
Maury page id
psix-444545

Documentation record

Tonnage as PSIX records it9438 - Convention (Subpart B), Gross Ton
9438 - Regulatory (Subpart C or D), Gross Ton
4037 - Convention (Subpart B), Net Ton
9357 - Dead Weight, Ton
15042 - Displacement, Ton
4037 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 37

22 June 2025 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8161017
11 June 2025 Deficiency Check · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8156973
7 April 2025 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8106608
9 December 2024 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8044895
15 November 2024 PSC A · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8035170
15 March 2024 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7879811
21 March 2023 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7654152
13 December 2021 MARPOL Annex VI Survey · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7367342
16 November 2021 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7351874
7 June 2021 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7218090
20 November 2020 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7098953
27 April 2020 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6944358
4 March 2020 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6916952
27 August 2019 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6795798
25 July 2019 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6761616
21 February 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6629463
14 January 2019 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6609808
17 September 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6542170
1 September 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6528848
3 August 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6499886
21 July 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6486086
10 July 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6473844
6 July 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6469476
20 June 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6450607
14 May 2018 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6413974
3 May 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6404842
7 April 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6387032
24 March 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6377773
12 March 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6370063
25 February 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6361090
9 February 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6352856
8 February 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6351790
3 January 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6332065
5 May 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6139407
13 March 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6104030
9 December 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6055106
28 January 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5804972

Deficiency record · 6

04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 11 June 2025 Resolved
Emergency generating set shall be equipped with at least 2 starting devices. PSCO observed a failure of the primary means of starting via the battery. 74 SOLAS(04) II-1/44.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2025
Resolution: RO submitted class survey attesting to the inoperable equipment being replaced and tested. Please see attached for more info.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 11 June 2025 Resolved
Rudder angle indicator shall determine and display rudder angle from the conning position. PSCO observed starboard bridge wing rudder angle indicator to be reading 4 degree or greater deviation from the true position. 74 SOLAS(20) V/19.2.5.4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2025
Resolved 22 June 2025
Resolution: Received class report attesting to the repair and full functionality of the STBD bridge wing rudder angle indicator.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 15 November 2024 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed rescue boat unable to start. 4th engineer and 2nd engineer troubleshot rescue boat and replaced fuel filter and spark plugs. The rescue boat was restored to full operational condition and was ready to start.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 November 2024
Resolved 15 November 2024
Resolution: 4th engineer and 2nd engineer troubleshot rescue boat and replaced fuel filter and spark plugs. Rescue boat was ran and tested to the satisfaction of the PSCO.
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 21 March 2023 Resolved
ALL ARRANGEMENTS USED FOR PILOT TRANSFER SHALL EFFICIENTLY FULFILL THEIR PURPOSE OF ENABLING PILOTS TO EMBARK AND AND DISEMBARK SAFELY. THE APPLIANCES SHALL BE KEPT CLEAN, PROPERLY MAINTAINED AND STOWED AND SHALL BE REGULARLY INSPECTED TO ENSURE THAT THEY ARE SAFE TO USE. LINE ON PILOT LADDER WAS FOUND TO HAE PARTED AND LADDER IS NOT IN A SERVICEABLE CONDITION.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2023
Resolved 4 April 2023
Resolution: Photographic evidence submitted showing replacement of pilot ladder.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 16 November 2021 Resolved
The condition of the ship and its equipment shall be maintained to ensure it remains fir for sea. While inbound, vessel experienced a loss of power. Make repairs and provide class report addressing the causative factors and corrective measures.
Action required: 60 - Rectify deficiencies prior to movement
Due 16 November 2021
Resolved 16 November 2021
Resolution: Repaired defective 220V 60hz magnetic contactor K5 in emergency switchboard. Class verified and op tested to satisfaction
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 June 2021 Resolved
An alarm system shall be provided indicating any fault requiring attention and shall be capable of sounding an audible alarm and indicate visually. PSCO observed audible and visual alarm indicators in the engine room were not working, 01 forward of the main engine and 01 at the main engine local control station.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 13 July 2021
Resolution: Received class report attesting to remote Class survey. Deficiency cleared.

Ownership record