Records from 1986 to 2000. Most recent: inspection, 22 September 2000.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 42
22 September 2000
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 822003
9 September 1999
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 783324
6 July 1999
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1090254
18 June 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1369264
18 June 1999
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1453625
8 June 1999
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 822002
10 June 1998
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1129184
4 May 1998
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1427505
20 April 1998
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1423015
23 March 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1386167
23 April 1997
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1105057
5 December 1996
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 878040
18 October 1996
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 847431
1 May 1996
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1082416
28 March 1996
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1077694
20 September 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1182166
19 May 1995
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 873904
23 March 1994
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 855610
21 March 1994
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1377173
20 July 1993
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1155041
11 March 1993
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 840260
20 April 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1257638
18 March 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1262649
13 January 1992
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 955411
10 September 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 936989
3 September 1991
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1252450
27 August 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1248900
27 March 1991
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 997235
20 April 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 931744
3 April 1990
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 927606
14 February 1990
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 927381
26 September 1989
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1320499
12 April 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1195357
3 October 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1194779
2 June 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 890451
15 April 1988
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1034791
25 March 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 990142
6 October 1987
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1318373
6 May 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1018811
2 April 1987
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1329125
22 April 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1293463
25 March 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 998336
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 18 June 1999
Resolved
Vessel is not to be operated with passengers for hire after March 11, 1999,until the above requirements have been cleared to the satisfaction of an attending U.S. Coast Guard Marine Inspector.
Condition: Unknown
Due 18 June 1999
Resolved 4 May 2001
Resolution: COI deactivated and defs were never cleared.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 18 June 1999
Resolved
Submit plans for review and approval for the installation of a Fixed Fire Fighting System in the machinery spaces in accordance with 46 CFR 181.115(b) and 46 CFR 181.400
Condition: Unknown
Due 18 June 1999
Resolved 4 May 2001
Resolution: COI deactivated and defs were never cleared.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 18 June 1999
Resolved
Install a Fixed Fire Fighting System in machinery spaces in accordance withU.S. Coast Guard approved plans.
Condition: Unknown
Due 18 June 1999
Resolved 4 May 2001
Resolution: COI deactivated and defs were never cleared.
Accommodation/Occupational Safety
Issued 18 June 1999
Resolved
BRIDGE WINDOWS: REPLACE 3 PORT AND 1 STBD WINDOWS (4 TOTAL) DUE TO BEING CRACKED.
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Engineering
Issued 18 June 1999
Resolved
PORT FUEL FILTER, CLEAN FLAME SHIELD AND REPAIR LEAK.
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Construction/Loadline
Issued 18 June 1999
Resolved
PLUG INLET AND OUTLETS AT PIPE AND VALVE FOR OLD JABSCO PUMP, LOCATED IN ENGINE ROOM STBD FRONT OF ENGINE.
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Engineering › Bilge Water Management System › Manifold
Issued 18 June 1999
Resolved
MAKE PERMENANT REPAIRS TO BILGE MANIFOLD, STBD END BELL. MARINE-TEX WAS NOTED DURING INSPECTION.
Condition: Unknown
Due 18 April 2000
Resolved 1 November 2004
Resolution: SEE INSPECTION NOTE THIS DATE.
Engineering › Bilge Water Management System › Not Installed
Issued 18 June 1999
Resolved
REPLACE ALL HOSES AND DOUBLE CLAMP FOR INSTALLED BILGE SYSTEM.
Condition: Unknown
Due 30 July 1999
Resolved 1 November 2004
Resolution: SEE INSPECTION NOTE THIS DATE.
Engineering › Bilge Water Management System › Valve
Issued 18 June 1999
Resolved
INSTALL A CHECK VALVE FOR THE ENGINE ROOM BILGE SUCTION LINE. NO CHECK VALVE INSTALLED DURING INSPECTION.
Condition: Unknown
Due 30 July 1999
Resolved 1 November 2004
Resolution: SEE INSPECTION NOTE THIS DATE.
Construction/Loadline
Issued 18 June 1999
Resolved
SUBMIT PLANS FOR APPROVAL OF HIGH LEVEL ALARM SYSTEM FOR BILGE. TYPE/MAKE,TYPE AND SIZE WIRE USED, TYPE OF FLOAT SWITCH INSTALLED, AND SOURCE OF POWER._x001C_
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 June 1999
Resolved
REPLACE PORT EXHAUST HOSE IWO EXHAUST PIPE IN LAZ. APPROX 10" X 8" HOSE.
Condition: Unknown
Due 30 April 2000
Resolved 1 November 2004
Resolution: SEE INSPECTION NOTE THIS DATE.
Engineering › Bilge Water Management System › Piping
Issued 18 June 1999
Resolved
DOUBLE CLAMP ALL SECONDARY BILGE PUMP HOSES AT PUMPS AND DISCHARGE.
Condition: Unknown
Due 30 July 1999
Resolved 1 November 2004
Resolution: SEE INSPECTION NOTE THIS DATE.
Lifesaving
Issued 18 June 1999
Resolved
STENCIL LIFE FLOATS WITH NAME OF VSL
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Documentation › Certificates/Documents › Stability Letter
Issued 18 June 1999
Resolved
SUPPLY STABILITY LTR OR REQUEST IN WRITING FOR A NEW/COPY OF STABILITY LTR.
Condition: Unknown
Due 18 July 1999
Resolved 1 November 2004
Resolution: SEE INSPECTION NOTE THIS DATE.
Lifesaving
Issued 18 June 1999
Resolved
PROVIDE MANUFACTURES INFO TAG OR INSTALL A NEW WEAK LINK FOR LIFE FLOATS
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Lifesaving
Issued 18 June 1999
Resolved
MOUNT LIFE FLOAT LIGHTS IN MANUFACTURES BRACKETS. LIGHTS WERE JUST SITTINGIN FLOATS DURING INSPECTION. BRACKETS WERE INSIDE OF PILOT HOUSE TO STORE LIGHTS WHEN NOT IN USE.
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Stability › Watertight Integrity › General
Issued 18 June 1999
Resolved
REPLACE/INSTALL NEW GASKETS IN ALL HATCH COVERS TO VOIDS.
Condition: Unknown
Due 30 July 1999
Resolved 1 November 2004
Resolution: SEE INSPECTION NOTE THIS DATE.
Lifesaving
Issued 18 June 1999
Resolved
REPLACE BULB IN LIFE FLOAT WATER LIGHT. LIGHT BLEW DURING INSPECTION.
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 June 1999
Resolved
MOUNT LIFE RING LIGHT IN A FLOAT FREE BRACKET. LIGHT HAD NO MOUNT DURING INSPECTION.
Condition: Unknown
Due 30 July 1999
Resolved 1 November 2004
Resolution: SEE INSPECTION NOTE THIS DATE.
Fire Fighting › Fixed Fire Detection System › Manually Operated Call Points
Issued 18 June 1999
Resolved
INSTALL ELECTRICAL HEAT DETECTOR/ALARM FOR FIXED FIRE EXTINGUISHING SYSTEM.PARTS ARE ON ORDER
Condition: Unknown
Due 20 July 1999
Resolved 1 November 2004
Resolution: SEE INSPECTION NOTE THIS DATE.
Accommodation/Occupational Safety
Issued 18 June 1999
Resolved
ANCHOR THE UPPER DECK HAND RAIL SUPPORTS AS FOLLOWS: PORT SIDE ANGLES AND STBD AFT ANGLE SUPPORT BARS TO DECK.
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Lifesaving
Issued 18 June 1999
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Lifesaving
Issued 18 June 1999
Resolved
CLEAN 37 SOILED LIFE JACKETS AND RENEW RETRO AS NEEDED. LIFE JACKETS ARE STILL SERVICABLE, BUT SOME OF THE RETRO WAS STARTING TO PEEL OFF.
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Construction/Loadline
Issued 18 June 1999
Resolved
MAKE REPAIRS TO REACH ROD IN FOREPEAK. ATTACH ROD TO VALVE HANDLE USING A U-BOLT. EXISTING U-BOLT IS BROKEN.
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Electrical
Issued 18 June 1999
Resolved
REMOVE DEAD ENDED CABLE IN ENGINE ROOM, LOCATED ON OVERHEAD, FORWARD, ON 4"JUNCTION BOX.
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Navigation
Issued 4 May 1998
Resolved
PROCURE UPDATED CHARTS OF THE AREA WITH NOTICE TO MARINERS.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Construction/Loadline
Issued 4 May 1998
Resolved
MOUNT BILGE PUMP IN E/R.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Lifesaving
Issued 4 May 1998
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Lifesaving
Issued 4 May 1998
Resolved
MOUNT WATER LIGHTS TO BA(S).
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Construction/Loadline
Issued 4 May 1998
Resolved
PROVE PROPER OPERATION OF REACH ROD IN FORWARD COMPARTMENT.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Navigation
Issued 4 May 1998
Resolved
PROVE PROPER OPERATION OF LORAN NAVIGATION SYSTEM.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Lifesaving
Issued 4 May 1998
Resolved
CLEAN AND PUT RETRO TAPE ON SOILED LIFEJACKETS.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Lifesaving
Issued 4 May 1998
Resolved
PROVE PROPER OPERATION OF PUBLIC ADDRESS SYSTEM.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Deck/Cargo
Issued 4 May 1998
Resolved
PROVE PROPER OPERATION OF ANCHOR WINDLESS.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Engineering
Issued 4 May 1998
Resolved
PROVE PROPER OPERATION OF BOTH TEMP. AND RPM GAUGES.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Fire Fighting
Issued 4 May 1998
Resolved
MOUNT ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Lifesaving
Issued 1 May 1996
Resolved
PROVIDE VESSEL WITH EMERGENCY BROADCAST PLACARD IAW 184.506
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Lifesaving
Issued 1 May 1996
Resolved
PROVIDE VESSEL WITH 406 EPIRB IAW 180.64
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Lifesaving
Issued 1 May 1996
Resolved
PROVIDE PROPER DOCUMENTATION OF FULLY COMPLIANT CHEMICAL TESTING PROGRAM FOR THE FOLLOWING DEFICIENCIES; NO PROGRAM ESTABLISHED FOR MASTER/CREW. MARINE EMPLOYER NOT AUTHORIZED TO OPERATE AFTER 1 JUN 96 UNLESS THIS REQUIREMENT HAS BEEN MET TO THE SATISFACTION OF ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Lifesaving
Issued 1 May 1996
Resolved
ADD RETROFLECTIVE TAPE TO LIFERING IAW 185.604I.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Accommodation/Occupational Safety
Issued 19 May 1995
Resolved
UPON COMPLETION OF INSTALLATION AND DURING 1ST TWO SAILINGS AFTERMAKE HOURLY VISUAL CHECK WHILE UNDERWAY.
Condition: Unknown
Due 2 June 1995
Resolved 28 March 1996
Accommodation/Occupational Safety
Issued 19 May 1995
Resolved
VESSEL IS RESTRICTED TO NOT MORE THAN 49 PASSENGERS, WHILE ONLY 1 MSD/TOILET FACILITY IS OPERATIONAL.
Condition: Unknown
Due 19 May 1995
Resolved 28 March 1996
Accommodation/Occupational Safety
Issued 19 May 1995
Resolved
PRIOR TO OPERATING IN ACCORDANCE WITH COI PROVE PROPER OPERATION OF BOTH TOILETS, HOLDING TANKS, FLUSH MECHANISMS, VALVES & PIPING.
Condition: Unknown
Due 2 June 1995
Resolved 28 March 1996
Construction/Loadline
Issued 20 July 1993
Resolved
A SIX (6) MONTH DRYDOCK EXTENSION HAS BEEN GRANTED FOR THIS VESSEL. THE VESSEL SHALL BE DRYDOCKED AND WILL BE MADE AVAILABLE FOR EXAMINATION BY A MARINE INSPECTOR FROM THE OFFICE OF THE COGNIZANT [name withheld] 31JAN94._x001C_
Condition: Unknown
Due 20 July 1993
Resolved 20 July 1993
Documentation
Issued 18 March 1992
Resolved
PROVIDE AND POST COPY OF VESSEL STABILITY LETTER.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Fire Fighting
Issued 18 March 1992
Resolved
REHYDRO 3 B-II FIRE EXTINGUISHERS OR PROVE HYDRO DONE FEB 91 WAS AT AN_x001C_ APPROVED FACILITY.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Electrical
Issued 18 March 1992
Resolved
REPLACE GENERATOR WET EXHAUST CONNECTOR WHERE WATER MEETS DRY EXHAUST.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Construction/Loadline
Issued 3 September 1991
Resolved
PROVE PROPER OPERATION OF ENGINE ROOM BILGE PUMP PRIOR TO SAILING. REMOVE OR CLEAN OIL PRIOR TO OPERATING BILGE PUMP.
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Engineering
Issued 3 September 1991
Resolved
PREVENT FUEL RETURN LINE CONNECTED TO STBD FUEL LINE FROM DRIPPING AT FLARED FITTING.
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Engineering
Issued 3 September 1991
Resolved
PROVE PROPER OPERATION OF PORT ENGINE IN THE PRESENSE OF MARINE INSPECTOR. THIS REQUIREMENT MUST BE COMPLETED NO LATER THAN 30AUG91 OR DURING DRYDOCK.
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Accommodation/Occupational Safety
Issued 3 September 1991
Resolved
REMOVE CRACKED LIGHT GLOBE ON STBD/AFT/EXTERIOR.
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Engineering
Issued 3 September 1991
Resolved
PROVE PROPER OPERATION OF PORT ENGINE. VESSEL IS RESTRICTED TO LAKES, BAYSAND SOUNDS UNTIL THIS REQUIREMENT IS MET.
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Construction/Loadline
Issued 3 September 1991
Resolved
PROVIDE CABLE FOR FORE PEAK MANHOLE COVER,.
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Navigation
Issued 3 April 1990
Resolved
PROVIDE TIDE AND CURRENT TABLES.
Condition: Unknown
Due 3 April 1990
Resolved 3 April 1990
Lifesaving
Issued 3 April 1990
Resolved
PROVIDE 14 ADULT AND 2 CHILDREN APPROVED LIFE PRESERVERS. TOTAL PERSONS ONBOARD LIMITED TO 59 PERSONS UNTIL PROVIDED.
Condition: Unknown
Due 3 April 1990
Resolved 3 April 1990
Construction/Loadline
Issued 14 February 1990
Resolved
REMOVE ANGEL HAIR FROM ENGINE ROOM OVERHEAD AND IN WAY OF FOREPEAK HATCH.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Engineering
Issued 14 February 1990
Resolved
INSTALL 30 X 30 MESH FLAME SCREENS BOTH FUEL TANK VENTS.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Engineering
Issued 14 February 1990
Resolved
SECURE REACH ROD TO FOR PEAK BILGE SUCTION VALVE.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Construction/Loadline
Issued 14 February 1990
Resolved
REPAIR VERTICAL MEMBERS PORT AND STARBOARD FRAME 3 FROM AFT BULKHEAD IN COMPARTMENT 2.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Engineering
Issued 14 February 1990
Resolved
PROVIDE TWO HOSE CLAMPS AT OVERBOARD FOR ENGINE ROOM AUTO, BILGE PUMP, AND IN COMPARTMENT 5 ON AFTER PORT/STARBOARD EXHAUST TUBES AND AT AUTO BILGE PUMP DISCHARGE.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Navigation
Issued 2 June 1988
Resolved
PROVIDE A MASTHEAD LIGHT WITH 3 MILE VISIBILITY.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Electrical
Issued 15 April 1988
Resolved
PROVIDE GUARDS FOR LIGHTS IN ENGINE ROOM AND ON DECK.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Navigation
Issued 15 April 1988
Resolved
RAISE MASTHEAD LIGHT TO CONFORM WITH ANNEX I OF COLREGS.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Engineering
Issued 2 April 1987
Resolved
PROVIDE AND INSTALL REACH ROD TO OPERATE BILGE SUCTION VALVE IN THE FORE PEAK SPACE.
Condition: Unknown
Due 2 April 1987
Resolved 2 April 1987
Engineering
Issued 2 April 1987
Resolved
PROVIDE FLAME SHIELDS FOR THE TWO RACOR FUEL FILTERS.
Condition: Unknown
Due 2 April 1987
Resolved 2 April 1987
Engineering
Issued 25 March 1986
Resolved
RENEW ALL NON USCG APPROVED FIRE AND BILGE PIPING WITH USCG APPROVED PIPING(BRONZE OR GALVINIZED STEEL). THIS REQUIREMENT TO BE COMPLETED TO THE SATISFACTION OF A USCG MARINE INSPECTOR PRIOR TO CERTIFICATION.
Condition: Unknown
Due 25 March 1986
Resolved 25 March 1986