DANIEL WEBSTER CLEMENTS

DANIEL WEBSTER CLEMENTS is a 1996 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in September 2023, along with 43 deficiencies and 1 casualty investigation in 2015.

Records from 2015 to 2023. Most recent: inspection, 6 September 2023.

Built
1996
Last inspected
6 September 2023
Documentation
Case Pending · documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 6 September 2023
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK2077
444591
Flag
UNITED STATES
Maury page id
psix-444591

Documentation record

Registered dimensions (L × B × D)54.0 ft × 17.8 ft × 6.7 ft
Registered tonnagegross 32 / net 28
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderZIRCOTT BOAT YARD, INC. · CODEN, AL, UNITED STATES · built 1996
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32 - Simplified, Gross Ton
28 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

6 September 2023 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7786145
21 November 2022 Hull Examination · In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7598411
20 April 2022 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7435971
2 March 2022 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7405168
3 December 2021 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7361802
14 April 2021 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7170529
15 June 2020 Annual Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6979179
10 February 2020 Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6906412
1 October 2019 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6825928
21 May 2019 DAPI Audit · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6704499
23 October 2018 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6570708
12 June 2018 Annual Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6436918
13 February 2018 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6350493
14 March 2017 Deficiency Check · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6100540
26 January 2017 Administrative Inspection · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6073558
19 April 2016 Administrative Inspection · DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5857125

Deficiency record · 43

07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 14 April 2021 Resolved
Port emergency fuel tank shutoff valve inoperative. Prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2021
Resolution: Fuel shutoff valve repaired.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 April 2021 Resolved
Remove all flammable items from galley area.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 April 2021
Resolution: Flammable items removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2021 Resolved
Properly terminate galley lighting electrical connections and dead end cables throughout.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 April 2021
Resolution: Cables removed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 April 2021 Resolved
Provide proof of alcohol testing devices.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 April 2021
Resolution: Testing equip provided.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 14 April 2021 Resolved
Provide proof of FCC Operators permit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 May 2021
Resolution: Operators permit provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2021 Resolved
Remove electrical heater from galley.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 15 April 2021
Resolution: Heater removed.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 14 April 2021 Resolved
EPIRB Hydro is expired; replace.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2021
Resolution: New EPIRB installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 April 2021 Resolved
Provide proof of sailing PMP.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 April 2022
Resolution: Verified PMP was onboard and in use. Review current rigging survey, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 April 2021 Resolved
Reduce passenger count by 4 adult passengers until a proper PFD is available for all passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 May 2021
Resolution: Missing lifejackets provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 April 2021 Resolved
Provide watchman procedures for overnight accommodations.
Action required: 10 - Deficiency Rectified
Resolved 15 April 2021
Resolution: Operator requested removal of overnight accommodations.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 April 2021 Resolved
Life ring light inoperative, provide proof of proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2021
Resolution: New light installed.
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 14 April 2021 Resolved
Provide mattresses in passenger accomadations prior to carring overnight passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 April 2021
Resolution: Removed overnight accomadation from COI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2021 Resolved
Install junction box in capts quarters properly to bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 April 2021
Resolution: Junction box installed.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 14 April 2021 Resolved
Remove or properly install galley range or provide repair proposal.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 May 2021
Resolution: Gallery range removed.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 14 April 2021 Resolved
Properly mouse sail pad eyes throughout.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 April 2021
Resolution: Pad eyes properly secured.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 June 2020 Resolved
Install missing smoke detectors.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 17 July 2020
Resolution: Installed missing smoke detector, tested all sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 June 2020 Resolved
Provide proper operation of emergency lighting.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 17 July 2020
Resolution: Emergency lighting tested, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 June 2020 Resolved
Properly secure main engine jacket water tank.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 17 July 2020
Resolution: Properly secured main engine jacket water tank.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 15 June 2020 Resolved
Replace missing port light dog nuts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 17 July 2020
Resolution: Replaced missing port light dog nuts.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 15 June 2020 Resolved
Properly mount forward berthing fan.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 17 July 2020
Resolution: Properly mounted forward berthing fan.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 June 2020 Resolved
Replace port upper mast turn buckle u-bolt pin.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 17 July 2020
Resolution: Replaced port upper mast turn buckle u-bolt pin.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 15 June 2020 Resolved
Provide proof of valid COD.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 17 July 2020
Resolution: Provided proof of valid COD.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 February 2020 Resolved
In accordance with the vessels stability letter, provide and maintain onboard a copy of the vessel's sail plan, revision 1, dated Dec 7, 1996, bearing USCG Marine Safety Center approval stamp dated Mar 18, 1997.
Due 6 March 2020
Resolved 6 March 2020
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 October 2019 Resolved
Emergency escape hatches must be marked on both sides EMERGENCY ESCAPE-KEEP CLEAR. Vsl shall marked both exits on teh outside. Must be completed before authorized to carry overnight passengers. 46 CFR 185.606
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 October 2019
Resolved 4 October 2019
Resolution: Crew marked emergency exits as required.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 May 2019 Resolved
Replace deadeyes as per Mast/Rigging survey dated 15JUN2018. Follow survey for corrective actions.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2019
Resolved 23 May 2019
Resolution: Operator replaced deadeyes as per the Mast/Rigging survey dated 15JUN2018.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 May 2019 Resolved
Forward bilge high water alarm inoperative.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2019
Resolved 23 May 2019
Resolution: Repaired bilge high water alarm, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 May 2019 Resolved
In forward head, has excessive wires, properly install or remove. Install missing junction box cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2019
Resolved 23 May 2019
Resolution: Wiring under sink cleaned up and junction box cover installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 May 2019 Resolved
Repair mast head light, prior to sailing after sunset to sunrise.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2019
Resolved 23 May 2019
Resolution: Repaired mast head light, tested all sat.
Sail Rigging › Stays/Shrouds › Wires
Issued 12 June 2018 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. The vessel’s operator could not show any records of rigging maintenance or inspection. The vessel operator is required to provide a 3rd party rigging survey.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2018
Resolved 26 June 2018
Resolution: The vessel operator provided a 3rd party rigging survey; all SAT.
Sail Rigging › Stays/Shrouds › Wires
Issued 12 June 2018 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. The vessel’s operator could not show any records of rigging maintenance or inspection. The vessel operator is required to develop a rigging inspection and PMP Plan.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2018
Resolved 26 June 2018
Resolution: vessel opertor provided a PMP plan; all SAT.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 14 March 2017 Resolved
Provide a Certificate of Documentation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 12 June 2018
Communications › Radio Communications › EPIRB
Issued 14 March 2017 Resolved
Provide an EPIRB for the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 12 June 2018
Fire Fighting › Fire Bucket › Quantity
Issued 14 March 2017 Resolved
Provide 3 Fire buckets
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 12 June 2018
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 March 2017 Resolved
Provide a servicable Life Ring Buoy, Line, Tape, and a stencil.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 12 June 2018
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 March 2017 Resolved
Provide a Port Navigational light.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 12 June 2018
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 14 March 2017 Resolved
Provide 9 new Life jackets for the vessel, the vessel may only carry 43 adult total passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 12 June 2018
Construction/Loadline › Structures › Deck Plating
Issued 14 March 2017 Resolved
Port bow wood repair.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 12 June 2018
Construction/Loadline › Hull › Transverse Frame
Issued 26 January 2017 Resolved
Renew the Shaft bearing support block.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 February 2017
Resolved 28 February 2017
Resolution: Witnessed underway
Operations/Management › Vessel Activity › Underway
Issued 26 January 2017 Resolved
Following the corrections vessel is required to conduct a satisfactory underway operational test.
Action required: 705 - Other - as specified
Due 10 February 2017
Resolved 28 February 2017
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 19 April 2016 Resolved
Missing 01 required Fire Extinguisher for vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 6 May 2016
Resolution: Corrected, vessel has appropriate number of FE.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 19 April 2016 Resolved
Life Buoy needs to be stenciled and retro tape replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 6 May 2016
Resolution: Corrected.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 April 2016 Resolved
Provide medical first aid kit.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 6 May 2016
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 19 April 2016 Resolved
Replace 14 life jackets on vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 6 May 2016
Resolution: Corrected.

Casualty record · 1

4 June 2015Routine · role: Involved in a Marine Casualty · activity 5147570
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.