Records from 1996 to 2023. Most recent: inspection, 6 September 2023.
Inspection history · 49
6 September 2023
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7786145
21 November 2022
Hull Examination · In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7598411
20 April 2022
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7435971
2 March 2022
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7405168
3 December 2021
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7361802
14 April 2021
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7170529
15 June 2020
Annual Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6979179
10 February 2020
Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6906412
1 October 2019
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6825928
21 May 2019
DAPI Audit · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6704499
23 October 2018
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6570708
12 June 2018
Annual Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6436918
13 February 2018
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6350493
14 March 2017
Deficiency Check · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6100540
26 January 2017
Administrative Inspection · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6073558
19 April 2016
Administrative Inspection · DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5857125
16 July 2015
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5183157
1 May 2014
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4846435
29 May 2012
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4320475
16 April 2009
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3449663
31 July 2008
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3278754
20 June 2007
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2968143
14 June 2007
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2961211
16 January 2007
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2858577
2 October 2006
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2791900
16 May 2006
Re-Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2651769
4 May 2005
COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2348968
29 March 2005
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2322044
24 August 2004
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2175203
2 June 2004
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2085968
18 June 2003
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1803643
9 April 2003
Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1772044
7 March 2003
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1752637
19 November 2002
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1707736
13 May 2002
Re-Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1616654
8 February 2002
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1485159
16 January 2002
In-Service Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1477165
10 May 2001
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1425148
8 March 2001
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1403306
9 May 2000
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1386981
29 April 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1460414
28 April 2000
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 145765
28 April 2000
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 1516334
11 March 1999
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1384194
2 June 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 792513
2 June 1998
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1454572
24 June 1997
Deficiency Check · Plan Review "T" Boat
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 773285
16 May 1997
Initial Construction-Excluding Oversight · Hull Examination · Initial Certification · Plan Review "T" Boat
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1447723
3 December 1996
Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1097661
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 14 April 2021
Resolved
Port emergency fuel tank shutoff valve inoperative. Prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2021
Resolution: Fuel shutoff valve repaired.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 April 2021
Resolved
Remove all flammable items from galley area.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 April 2021
Resolution: Flammable items removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2021
Resolved
Properly terminate galley lighting electrical connections and dead end cables throughout.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 April 2021
Resolution: Cables removed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 April 2021
Resolved
Provide proof of alcohol testing devices.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 April 2021
Resolution: Testing equip provided.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 14 April 2021
Resolved
Provide proof of FCC Operators permit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 May 2021
Resolution: Operators permit provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2021
Resolved
Remove electrical heater from galley.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 15 April 2021
Resolution: Heater removed.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 14 April 2021
Resolved
EPIRB Hydro is expired; replace.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2021
Resolution: New EPIRB installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 April 2021
Resolved
Provide proof of sailing PMP.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 April 2022
Resolution: Verified PMP was onboard and in use. Review current rigging survey, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 April 2021
Resolved
Reduce passenger count by 4 adult passengers until a proper PFD is available for all passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 May 2021
Resolution: Missing lifejackets provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 April 2021
Resolved
Provide watchman procedures for overnight accommodations.
Action required: 10 - Deficiency Rectified
Resolved 15 April 2021
Resolution: Operator requested removal of overnight accommodations.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 April 2021
Resolved
Life ring light inoperative, provide proof of proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2021
Resolution: New light installed.
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 14 April 2021
Resolved
Provide mattresses in passenger accomadations prior to carring overnight passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 April 2021
Resolution: Removed overnight accomadation from COI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2021
Resolved
Install junction box in capts quarters properly to bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 April 2021
Resolution: Junction box installed.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 14 April 2021
Resolved
Remove or properly install galley range or provide repair proposal.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 May 2021
Resolution: Gallery range removed.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 14 April 2021
Resolved
Properly mouse sail pad eyes throughout.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 April 2021
Resolution: Pad eyes properly secured.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 June 2020
Resolved
Install missing smoke detectors.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 17 July 2020
Resolution: Installed missing smoke detector, tested all sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 June 2020
Resolved
Provide proper operation of emergency lighting.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 17 July 2020
Resolution: Emergency lighting tested, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 June 2020
Resolved
Properly secure main engine jacket water tank.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 17 July 2020
Resolution: Properly secured main engine jacket water tank.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 15 June 2020
Resolved
Replace missing port light dog nuts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 17 July 2020
Resolution: Replaced missing port light dog nuts.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 15 June 2020
Resolved
Properly mount forward berthing fan.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 17 July 2020
Resolution: Properly mounted forward berthing fan.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 June 2020
Resolved
Replace port upper mast turn buckle u-bolt pin.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 17 July 2020
Resolution: Replaced port upper mast turn buckle u-bolt pin.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 15 June 2020
Resolved
Provide proof of valid COD.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 17 July 2020
Resolution: Provided proof of valid COD.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 February 2020
Resolved
In accordance with the vessels stability letter, provide and maintain onboard a copy of the vessel's sail plan, revision 1, dated Dec 7, 1996, bearing USCG Marine Safety Center approval stamp dated Mar 18, 1997.
Due 6 March 2020
Resolved 6 March 2020
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 October 2019
Resolved
Emergency escape hatches must be marked on both sides EMERGENCY ESCAPE-KEEP CLEAR. Vsl shall marked both exits on teh outside. Must be completed before authorized to carry overnight passengers.
46 CFR 185.606
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 October 2019
Resolved 4 October 2019
Resolution: Crew marked emergency exits as required.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 May 2019
Resolved
Replace deadeyes as per Mast/Rigging survey dated 15JUN2018. Follow survey for corrective actions.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2019
Resolved 23 May 2019
Resolution: Operator replaced deadeyes as per the Mast/Rigging survey dated 15JUN2018.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 May 2019
Resolved
Forward bilge high water alarm inoperative.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2019
Resolved 23 May 2019
Resolution: Repaired bilge high water alarm, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 May 2019
Resolved
In forward head, has excessive wires, properly install or remove. Install missing junction box cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2019
Resolved 23 May 2019
Resolution: Wiring under sink cleaned up and junction box cover installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 May 2019
Resolved
Repair mast head light, prior to sailing after sunset to sunrise.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2019
Resolved 23 May 2019
Resolution: Repaired mast head light, tested all sat.
Sail Rigging › Stays/Shrouds › Wires
Issued 12 June 2018
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. The vessel’s operator could not show any records of rigging maintenance or inspection. The vessel operator is required to provide a 3rd party rigging survey.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2018
Resolved 26 June 2018
Resolution: The vessel operator provided a 3rd party rigging survey; all SAT.
Sail Rigging › Stays/Shrouds › Wires
Issued 12 June 2018
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. The vessel’s operator could not show any records of rigging maintenance or inspection. The vessel operator is required to develop a rigging inspection and PMP Plan.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2018
Resolved 26 June 2018
Resolution: vessel opertor provided a PMP plan; all SAT.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 14 March 2017
Resolved
Provide a Certificate of Documentation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 12 June 2018
Communications › Radio Communications › EPIRB
Issued 14 March 2017
Resolved
Provide an EPIRB for the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 12 June 2018
Fire Fighting › Fire Bucket › Quantity
Issued 14 March 2017
Resolved
Provide 3 Fire buckets
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 12 June 2018
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 March 2017
Resolved
Provide a servicable Life Ring Buoy, Line, Tape, and a stencil.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 12 June 2018
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 March 2017
Resolved
Provide a Port Navigational light.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 12 June 2018
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 14 March 2017
Resolved
Provide 9 new Life jackets for the vessel, the vessel may only carry 43 adult total passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 12 June 2018
Construction/Loadline › Structures › Deck Plating
Issued 14 March 2017
Resolved
Port bow wood repair.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 12 June 2018
Construction/Loadline › Hull › Transverse Frame
Issued 26 January 2017
Resolved
Renew the Shaft bearing support block.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 February 2017
Resolved 28 February 2017
Resolution: Witnessed underway
Operations/Management › Vessel Activity › Underway
Issued 26 January 2017
Resolved
Following the corrections vessel is required to conduct a satisfactory underway operational test.
Action required: 705 - Other - as specified
Due 10 February 2017
Resolved 28 February 2017
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 19 April 2016
Resolved
Missing 01 required Fire Extinguisher for vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 6 May 2016
Resolution: Corrected, vessel has appropriate number of FE.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 19 April 2016
Resolved
Life Buoy needs to be stenciled and retro tape replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 6 May 2016
Resolution: Corrected.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 April 2016
Resolved
Provide medical first aid kit.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 6 May 2016
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 19 April 2016
Resolved
Replace 14 life jackets on vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 6 May 2016
Resolution: Corrected.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 1 May 2014
Resolved
Provide EPRIB hydrostatic release. Vessel is restricted to no more than 3NM
Action required: 705 - Other - as specified
Due 7 May 2014
Resolved 7 May 2014
Resolution: Vessel replaced hydro release.
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 1 May 2014
Resolved
Provide current deviation card
Action required: 705 - Other - as specified
Due 1 June 2014
Resolved 2 June 2014
Resolution: Vessel provided deviation card.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 31 July 2008
Resolved
Provide documentation for abandon ship drill.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2008
Documentation › Certificates/Documents › FCC SSL
Issued 31 July 2008
Resolved
Provide documentation for radiotelephony safety certificate.
Due 31 August 2008
Resolved 11 September 2008
Resolution: Commercial company was unable to issue certificate until this date.
Fire Fighting
Issued 10 May 2001
Resolved
PRIOR TO CARRYING PASSEGERS FOR HIRE INSTALL PORTABLE/FIXED FIREFIGHTING SYSTEM IN ENGINE ROOM. PROVIDE SERVICE REPORT FOR RECHARGE OF EXISTING DISCHARGED SYSTEM._x001C_ _x001C_
Condition: Unknown
Due 10 June 2001
Resolved 21 June 2001
Accommodation/Occupational Safety
Issued 29 April 2000
Resolved
Prior to the carriage of passengers, complete necessary repairs to port side deck railing and life lines damaged in collision. Contact CG Panama City to inspect vessel reapirs to hand rails and life line anchor plates.
Condition: Unknown
Due 11 May 2000
Resolved 10 May 2000
Navigation
Issued 16 May 1997
Resolved
Provide day shapes IAW 72 Colregs M16672.2 Rule 25, 27, & 30.
Condition: Unknown
Due 16 June 1997
Resolved 9 July 1997
Navigation
Issued 16 May 1997
Resolved
Provide and prove proper operation of the vessel's Public address system. Install speakers in each accommodation area and the main deck. IAW 46 CFR 184.610
Condition: Unknown
Due 16 June 1997
Resolved 9 July 1997
Electrical
Issued 16 May 1997
Resolved
Each nonmetallic mast and top mast must have a lightning ground conductor_x001C_ IAW 46 CFR 1830.370(c).
Condition: Unknown
Due 16 June 1997
Resolved 9 July 1997
Navigation
Issued 16 May 1997
Resolved
Provide and install a power horn IAW 72 Colregs M16672.2 AnnexIII 1.
Condition: Unknown
Due 16 June 1997
Resolved 9 July 1997
Electrical
Issued 16 May 1997
Resolved
Provide for review and approval accurate electrical drawings IAW 46 CFR 177.202(4), 183.340 and table 183.340(p).
Condition: Unknown
Due 16 June 1997
Resolved 9 July 1997
Documentation
Issued 16 May 1997
Resolved
Provide a valid FCC Safety Certificate IAW 47 CFR 80.903
Condition: Unknown
Due 16 June 1997
Resolved 9 July 1997
Lifesaving
Issued 16 May 1997
Resolved
Provide a Coast Guard approved First Aid kit or order all items required by46 CFR 160.041 IAW 46 CFR 184.710.
Condition: Unknown
Due 16 June 1997
Resolved 9 July 1997
Engineering
Issued 16 May 1997
Resolved
Provide and install a stop valve in the engine end of the fuel line IAW 46 CFR 182.455 (b)(4)
Condition: Unknown
Due 16 June 1997
Resolved 9 July 1997