MAURY USCG vessel records Sign in
← All vessels

DONNA G

DONNA G is a 1963 passenger vessel (inspected). The Coast Guard has recorded 54 inspections since 1985, most recently in July 2012, along with 152 deficiencies and 1 casualty investigation in 2003.

Records from 1985 to 2012. Most recent: inspection, 10 July 2012.

Built
1963
Last inspected
10 July 2012
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG2290
Flag
UNITED STATES
366905680, 367514180 (licence lapsed)
Maury page id
psix-44461

Inspections, by type

…with no type recorded4
Years with a record 25 calendar years (1985–2012)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)53.0 ft × 16.0 ft × 4.0 ft
Registered tonnagegross 25 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPRICE BOAT YARD · DELTAVILLE, VA, UNITED STATES · built 1963
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOWARD BEACH, NY
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Regulatory (Subpart C or D), Gross Ton
17 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG2296MMSI 367514180 · expired · compulsorily equipped · granted 31 December 2011, cancelled 5 March 2022
WDB5083MMSI 366905680 · expired · compulsorily equipped · granted 22 August 2003, cancelled 9 November 2013
WN2996MMSI not assigned · cancelled · compulsorily equipped · granted 28 October 1998, cancelled 7 November 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 54

10 July 2012 Internal Structural Exam · COI Inspection · Deficiency Check · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4374036
18 March 2010 Deficiency Check · COI Inspection · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3697850
15 November 2007 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3054016
21 June 2006 Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2687263
7 April 2005 MARPOL Annex V Examination · Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2331878
11 May 2004 Deficiency Check · COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2064601
30 September 2003 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1917113
21 August 2003 Internal Structural Exam · Deficiency Check · Annual Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1882875
14 June 2002 Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1630844
30 April 2002 Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1610741
19 June 2001 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1415635
16 May 2001 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1403443
5 April 2001 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1060912
8 May 2000 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 818592
19 April 2000 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1458761
8 June 1999 Damage Survey
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1411893
19 May 1999 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1445520
27 April 1999 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1369140
12 May 1998 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 791077
6 May 1998 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1125912
8 May 1997 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1101272
23 April 1997 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1437239
25 April 1996 Deficiency Check · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1089186
1 April 1996 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 885920
3 May 1995 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1205453
7 November 1994 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 868382
6 July 1994 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1172963
4 May 1994 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1409123
14 December 1993 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1409064
16 June 1993 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 843144
26 May 1993 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1145708
7 May 1993 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1459007
8 January 1993 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1399792
16 July 1992 Damage Survey
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 942986
12 June 1992 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1268297
15 November 1991 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1245836
24 October 1991 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1250946
24 October 1991 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1250948
12 December 1990 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1235217
1 November 1990 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1243383
9 May 1990 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 916500
8 December 1989 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1229909
9 November 1989 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1345344
16 November 1988 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1206125
14 October 1988 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 886879
23 June 1988 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1339365
17 December 1987 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1315414
5 October 1987 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1329724
4 May 1987 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1018290
2 December 1986 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1328917
8 May 1986 Credit Drydock
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1311030
7 May 1986 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 993112
20 May 1985 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1290546
7 March 1985 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1290253

Deficiency record · 152

Construction/Loadline › Hull › Keel
Issued 20 September 2012 Resolved
Vessel has water leaking through repair made to the keelson in the laz. Remove repair and call out CGMI for further inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2012
Resolution: Attended vessel with SPV Branch [name withheld] for further inspection, no water leakage was visible during sea trials, a special note was added to conduct sea trials at every CG inspection and inspect area for water leaks.
Construction/Loadline › Hull › Hull Plating
Issued 20 September 2012 Resolved
Replace planking IWO chine in third compartment frames 2-5 port and stbd.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2012
Resolution: Attended vessel with SPV Branch [name withheld] for further inspection, no water leakage was visible during sea trials, a special note was added to conduct sea trials at every CG inspection and inspect area for water leaks.
Stability › Watertight Integrity › General
Issued 20 September 2012 Resolved
Replace non water tight hatch IWO laz.
Action required: 705 - Other - as specified
Due 11 October 2012
Resolved 25 October 2012
Resolution: Vessel replaced hatch with watertight hatch.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 20 September 2012 Resolved
Remove paint thinners and extension cords from vessel.
Action required: 705 - Other - as specified
Due 27 September 2012
Resolved 27 September 2012
Resolution: Attended vessel, paint thinners and extension cords were removed.
Stability › Watertight Integrity › General
Issued 20 September 2012 Resolved
Make collision bulkhead water tight.
Action required: 705 - Other - as specified
Due 11 October 2012
Resolved 25 October 2012
Resolution: Vessel filled gaps of bulkhead to make watertight.
Electrical › Electric Supply System (service) › Cable
Issued 23 August 2012 Resolved
DK04: Repair electric submersible pump wiring in the 2nd compartment.
Action required: 705 - Other - as specified
Due 20 September 2012
Resolved 20 September 2012
Resolution: Attended vessel, inspected satisfactory repairs.
Electrical › Electric Supply System (service) › Cable
Issued 23 August 2012 Resolved
DK05: Install grounding wire on port and stbd fuel tank fill line IWO flexible hose.
Action required: 705 - Other - as specified
Due 20 September 2012
Resolved 20 September 2012
Resolution: Attended vessel, inspected satisfactory repairs.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 23 August 2012 Resolved
DK01: Pre-engineered fixed gas fire extinguishing system must have (1.) Be capable of manual actuation from outside the space. (2.) Automatically shutdown the engines. (3.) Be installed IAW manufacturer's instructions. (4.) A light to indicate discharge. (5.) An audible alarm that sounds upon discharge. (6.) A means to reset / override engine shut down.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2012
Resolution: Attended vessel, inspected and tested pre-engineered fixed gas fire extinguishing system. All satisfactory.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 23 August 2012 Resolved
DK02: Provide DAPI enrollment letter w/ current crew list.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2012
Resolution: The vessel has a current DAPI enrollment letter.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 23 August 2012 Resolved
DK03: Life jackets must be stowed IAW 46 CFR 180.78 (Stowage container must not be capable of being locked.)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2012
Resolution: Attended vessel, inspected satisfactory stowage of life jackets..
Lifesaving › Hand Flares › Storage
Issued 23 August 2012 Resolved
PF07: Vessel must provide portable water tight container for distress signals.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2012
Resolution: Attended vessel, inspected satisfactory stowage of distress signals.
Navigation › Piloting/Steering › Marine Charts
Issued 23 August 2012 Resolved
PF06: Vessel must provide up to date charts for NY area of operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2012
Resolution: Attended vessel, witnessed up to date charts onboard.
Stability › Watertight Integrity › General
Issued 23 August 2012 Resolved
DK08: Remove water from Laz for further inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2012
Resolution: Water was removed and the source of the leak was identified. Owner made unsatisfactory repairs. rewrote def to address leak in the keel in the Laz approx 3 - 4 ft aft of the watertight bulkhead.
Construction/Loadline › Hull › Side Shell
Issued 20 July 2012 Resolved
Conduct satisfactory sea trials in presence of CGMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2012
Resolution: Conducted satisfactory sea trials.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 10 July 2012 Resolved
Replace all plastic sea strainers with metallic type.
Action required: 705 - Other - as specified
Due 31 July 2014
Resolved 29 November 2012
Resolution: New vessel requirement, not required in Old T.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 12 April 2010 Resolved
Provide photographic evidence that both vessel propellers were replaced and properly installed prior to getting under way with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2010
Resolved 13 April 2010
Resolution: Received photographic evidence of installation of twin screws.
Construction/Loadline › Hull › Transverse Frame
Issued 12 April 2010 Resolved
Provide photographic evidence that port and starboard stern tube and strut rubber cutless bearings were replaced and properly installed prior to getting under way with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 October 2010
Resolution: Received letter from [name withheld] stating P/S propeller were reconditioned and cutless bearings replaced. Also vessel was sea trialed and found satisfactory.
Construction/Loadline › Hull › Transverse Frame
Issued 12 April 2010 Resolved
Remove all angel hair down to good wood those areas identified on overhead beams, frames and deck floors as discussed during the dry dock period. Prior to treating the wood, ensure each affected area is as dry as possible.
Action required: 705 - Other - as specified
Resolved 29 October 2010
Construction/Loadline › Hull › Strut/Cross Tie
Issued 12 April 2010 Resolved
Provide photographic evidence that all cutlass bearings on the forward and aft struts were replaced and installed properly prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2010
Resolved 13 April 2010
Resolution: Master provided a signed statement and provided his license number as confirmation that all four cutlass bearings were replaced and installed properly.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 12 April 2010 Resolved
Provide a valid Certificate of Documentation that reflects the new owner, operator and vessel name prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2010
Resolved 13 May 2010
Resolution: A new Certificate of Documentation was provided and posted as directed.
Lifesaving › Lifefloat › Serviceable
Issued 12 April 2010 Resolved
Properly install and outfit two, 22 person life floats n accordance with 46 CFR 180.137 and 46 CFR 180.175 prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2010
Resolved 13 May 2010
Resolution: Both lifefloats were installed, properly outfitted and met all the requirements of 46 CFR 180.137 and 46 CFR 180.175.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 12 April 2010 Resolved
Provide servicing for all portable fire extinguishers and the fixed gas fire extinguishing system prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2010
Resolved 13 May 2010
Resolution: All portable fire extinguishers were serviced in May 2010 by Sea Safety.
Construction/Loadline › Hull › Sheerstrake
Issued 12 April 2010 Resolved
Replace rotten sections of wood along the gunwale on the aft deck, starboard side as marked and discussed with the vessel representative prior to carrying passengers. Both the coaming and cap need to be replaced to prevent the further spread of rot.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2010
Resolved 13 May 2010
Resolution: All repair work along the gunwales was completed and was inspected satisfactory by an attending Coast Guard Marine Inspector.
Documentation › Certificates/Documents › FCC SSL
Issued 12 April 2010 Resolved
Provide a valid FCC Safety Certificate. Vessel is restricted to operations no more than 1000 feet from shore until the radio equipment is surveyed and a new certificate is issued to the operator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 October 2010
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 April 2010 Resolved
Make repairs to the starboard side running light and demonstrate proper operation to an attending Coast Guard Marine Inspector. Vessel is restricted to daylight operations and periods when the visibility is greater than one mile until corrective action is taken.
Action required: 705 - Other - as specified
Due 12 May 2010
Resolved 13 May 2010
Resolution: Tested starboard navigation light and found it to be burning brightly.
Navigation › Piloting/Steering › Magnetic Compass
Issued 12 April 2010 Resolved
Make repairs to the illumination for the magnetic compass and demonstrate proper operation to an attending Coast Guard Marine Inspector. Vessel is restricted to daylight operations until corrective action is taken.
Action required: 705 - Other - as specified
Due 12 May 2010
Resolved 13 May 2010
Resolution: Tested magnetic compass light and found it burning brightly.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 April 2010 Resolved
Remove all expired medications and replace with current medication for the first aid kit in accordance with 46 CFR 184.710 and ensure the first aid kit has all the required contents in accordance with 46 CFR 160.041.
Action required: 705 - Other - as specified
Due 12 May 2010
Resolved 13 May 2010
Resolution: A new first aid kit approved under 46 CFR 160.041 was placed on board.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 April 2010 Resolved
Provide proof that each wire connector and lug meets UL 486A. If approved, ensure that all twist on lugs are only used in enclosed spaces and the twist on lug is properly connected to prevent loosening by vibration in accordance with 46 CFR 183.340 (i).
Action required: 705 - Other - as specified
Due 12 May 2010
Resolved 13 May 2010
Resolution: All twist type lug nuts were secured with electrical tape to prevent loosening and then placed in a junction box.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 12 April 2010 Resolved
Provide a Waste Management Plan that meets all the requirements in 33 CFR 151.57.
Action required: 705 - Other - as specified
Due 12 May 2010
Resolved 13 April 2010
Resolution: Vessel representative drafted and emailed a copy of his drafted waste management plan.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 12 April 2010 Resolved
Provide evidence that the halocarbon gas fire extinguishing bottle installed in the engine room meets the installation instructions of the manufacturer in accordance with 46 CFR 181.420 (a)(4).
Action required: 705 - Other - as specified
Due 12 May 2010
Resolved 13 May 2010
Resolution: New installation of the fire buoy system was installed in accordance with manufacturers installation instructions.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 12 April 2010 Resolved
Make repairs to the starboard engine RPM indicator gauge located at the operating station and demonstrate proper operation of the same to an attending Coast Guard Marine Inspector while underway.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 October 2010
Electrical › Electrical Distribution System (service) › Junction Box
Issued 12 April 2010 Resolved
Cover electrical outlet in engine room.
Action required: 705 - Other - as specified
Due 12 May 2010
Resolved 13 May 2010
Resolution: A cover was provided for the outlet in the machinery space.
Engineering › Fuel Oil Service System › Filter
Issued 12 April 2010 Resolved
Re-bolt starboard filter to bulkhead.
Action required: 705 - Other - as specified
Due 12 May 2010
Resolved 13 May 2010
Resolution: Engine filter was rebolted and found to be holding strong.
Electrical › Lighting (service) › Lighting Fixture
Issued 12 April 2010 Resolved
Add guard to lighting fixture in engine room.
Action required: 705 - Other - as specified
Due 12 May 2010
Resolved 13 May 2010
Resolution: A guard was provided for the light fixture.
Engineering › Fuel Oil Service System › Tank
Issued 12 April 2010 Resolved
Properly remove and dispose of excessive fuel in tank space.
Action required: 705 - Other - as specified
Due 12 May 2010
Resolved 13 May 2010
Resolution: All excessive fuel was removed and tank space was found to be in a clean condition.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 April 2010 Resolved
Remove stray wire from electrical box on bulkhead behind port fuel tank.
Action required: 705 - Other - as specified
Due 12 May 2010
Resolved 13 May 2010
Resolution: Stray wire was cut off and placed in a junction box.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 12 April 2010 Resolved
Attach captive chains to hatches to void #1 and #2.
Action required: 705 - Other - as specified
Due 12 May 2010
Resolved 13 May 2010
Resolution: Captive chains were provided for both hatches.
Lifesaving › Lifefloat › Serviceable
Issued 12 April 2010 Resolved
Repair life floats with manufacturers approved repair kit prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2010
Resolved 13 May 2010
Resolution: Repairs to life floats were made and observed to be satisfactory.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 12 April 2010 Resolved
Label capacity for adult life preservers in accommodation space.
Action required: 705 - Other - as specified
Due 12 May 2010
Resolved 13 May 2010
Resolution: Lifejacket locker was labelled with the total number of life jackets as directed.
Engineering › Fuel Oil Service System › Valve
Issued 12 April 2010 Resolved
Label both fuel cut-off valves.
Action required: 705 - Other - as specified
Due 12 May 2010
Resolved 13 May 2010
Resolution: Both fuel shut off valves were properly labelled.
Stability › Watertight Integrity › General
Issued 21 June 2006 Resolved
Conduct sea trials to the sat of the attending CG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2006
Navigation › Piloting/Steering › US Coast Pilot
Issued 20 June 2006 Resolved
Update navigational publications, US Coast Pilot and CG Light List.
Action required: 705 - Other - as specified
Due 5 July 2006
Resolved 26 June 2006
Communications › Radio Communications › EPIRB
Issued 20 June 2006 Resolved
EPIRB does not properly test and NOAA registration is expired. Have EPIRB serviced and prove proper test capability and registration.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 June 2006 Resolved
Conduct housekeeping on wires port of pilot station console. Properly terminate wires.
Action required: 705 - Other - as specified
Due 5 July 2006
Resolved 29 June 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 June 2006 Resolved
Properly terminate wires for PA system starboard of pilot station console.
Action required: 705 - Other - as specified
Due 5 July 2006
Resolved 29 June 2006
Electrical › Electrical Distribution System (service) › Fuse
Issued 20 June 2006 Resolved
Properly fuse radio at main panel. Radio currently is without any fuse and has improperly terminated wires on the back. Properly terminate wires.
Action required: 705 - Other - as specified
Due 5 July 2006
Resolved 10 July 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 20 June 2006 Resolved
Properly torque bolt for engine start, Engine #2, starboard of pilot console.
Action required: 705 - Other - as specified
Due 5 July 2006
Resolved 29 June 2006
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 20 June 2006 Resolved
Replace retro-reflective tape on PFDs, 09 adult and 01 child rejected by MI.
Action required: 705 - Other - as specified
Due 5 July 2006
Resolved 26 June 2006
Construction/Loadline › Hull › Girder
Issued 20 June 2006 Resolved
Resecure support beam for upper deck in void #2 port side.
Action required: 705 - Other - as specified
Due 5 July 2006
Resolved 26 June 2006
Stability › Watertight Integrity › General
Issued 20 June 2006 Resolved
Vessel is not watertight. Submit repair proposal to address areas of water ingress, or drydock vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2006
Stability › Watertight Integrity › General
Issued 20 June 2006 Resolved
Investigate source of rudderpost leak.
Action required: 705 - Other - as specified
Due 5 July 2006
Resolved 29 June 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 7 April 2005 Resolved
Provide USCG with servicing paperwork for fixed F/Fighting system.
Condition: Unknown
Due 22 April 2005
Resolved 25 April 2005
Resolution: Paperwork provided IAW the fixed F/Fighting system.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 7 April 2005 Resolved
Replace (01) adult lifejacket.
Condition: Placed in Improper Service
Due 22 April 2005
Resolved 25 April 2005
Resolution: Lifejacket replaced with spare.
Communications › Radio Communications › EPIRB
Issued 7 April 2005 Resolved
EPIRB hydrostatic release expired.
Condition: Improper/Lack of Maintenance
Due 22 April 2005
Resolved 25 April 2005
Resolution: Hydrostatic release replaced with RFI.
Personnel › Certificates/Documents/Licenses
Issued 11 May 2004 Resolved
Provide FCC operator permit.
Due 25 May 2004
Resolved 13 May 2004
Operations/Management › Drug and Alcohol Testing
Issued 11 May 2004 Resolved
Provide employer policy for drug and alcohol program.
Due 5 June 2004
Resolved 25 May 2004
Resolution: Found documentation in folder clearing def.
Documentation › Logs/Records
Issued 11 May 2004 Resolved
Properly log all required monthly drills and training. (I.E. Man overboard & fire fighting)
Due 25 May 2004
Resolved 28 May 2004
Resolution: Owner provided log book, documented man overboard and fire drill conducted same date.
Navigation › Piloting/Steering
Issued 11 May 2004 Resolved
Provide current copy of the U. S. Light List publication. LEGACY COMPONENT DESC: Coast Guard Light List
Due 5 June 2004
Resolved 4 June 2004
Resolution: Received fax of receipt for purchase of said item.
Navigation › Piloting/Steering › US Coast Pilot
Issued 11 May 2004 Resolved
Provide current copy of the Coast Pilot publication.
Due 25 May 2004
Resolved 11 May 2004
Navigation › Piloting/Steering
Issued 11 May 2004 Resolved
Provide current copy of Navigational Rules. (COMDTINST M16672.2E) LEGACY COMPONENT DESC: Inland Navigation Rules
Due 5 June 2004
Resolved 4 June 2004
Resolution: Received fax of receipt for purchase of said item.
Accommodation/Occupational Safety › Occupational Safety
Issued 11 May 2004 Resolved
Provide portable lighting at operating station.
Due 25 May 2004
Resolved 11 May 2004
Construction/Loadline › Hull › Transverse Frame
Issued 11 May 2004 Resolved
Remove angel hair on transverse overhead frame IWO ank space. (2nd frame back from port fuel tank)
Due 25 May 2004
Resolved 11 May 2004
Construction/Loadline › Hull › Transverse Frame
Issued 11 May 2004 Resolved
Remove angel hair on transverse overhead frame IWO tank space. (last frame on aft stbd fuel tank)
Due 25 May 2004
Resolved 11 May 2004
Construction/Loadline › Penetrations
Issued 11 May 2004 Resolved
Make void #2 and tank space watertight. (two pipes)
Due 25 May 2004
Resolved 28 May 2004
Resolution: Owner made space watertight.
Engineering › Bilge Water Management System
Issued 11 May 2004 Resolved
Properly connect portable bilge pump wiring and replace cover to junction box.
Due 25 May 2004
Resolved 11 May 2004
Electrical
Issued 11 May 2004 Resolved
Replace cover to the grounding strap (fuel) junction box.
Due 25 May 2004
Resolved 11 May 2004
Electrical › Electric Supply System (service)
Issued 11 May 2004 Resolved
Remove liquid from both port and stbd battery boxes in E/R.
Due 25 May 2004
Resolved 28 May 2004
Resolution: Water removed.
Construction/Loadline › Structures
Issued 11 May 2004 Resolved
Properly remove all angel hair from E/R bulheads. LEGACY COMPONENT DESC: Transverse Bulkhead
Due 25 May 2004
Resolved 28 May 2004
Resolution: [name withheld] removed.
Construction/Loadline › Structures
Issued 11 May 2004 Resolved
Properly remove all angel hair from E/R overhead.
Due 25 May 2004
Resolved 28 May 2004
Resolution: [name withheld] removed.
Pollution Prevention/Response
Issued 11 May 2004 Resolved
Remove spill excess oil from E/R deck.
Due 25 May 2004
Resolved 11 May 2004
Construction/Loadline › Hull
Issued 11 May 2004 Resolved
Remove angel hair from stbd rudder post base board.
Due 25 May 2004
Resolved 28 May 2004
Resolution: [name withheld] removed.
Construction/Loadline › Penetrations
Issued 11 May 2004 Resolved
Make E/R and Lazarette watertight. (bulkhead penetration to the left of port exhaust)
Due 25 May 2004
Resolved 28 May 2004
Resolution: Proper repair completed.
Lifesaving › Buoyant Apparatus
Issued 11 May 2004 Resolved
Vessel only carries (40 persons) 2/ 20 person BAs. Vessel is restricted to carrying 38 passengers until May 31, 2004.
Due 5 June 2004
Resolved 1 June 2004
Resolution: Vsl meets life saving provisions of COI for full complement of passengers as of 01 June 2004 due to warm water in the NY AOR. Vsl COI will be amended to reflect restrict during the cold water season.
Fire Fighting › Fire Pumps
Issued 11 May 2004 Resolved
Prove proper operation of bilge/fire pump. Vessel is restricted from carrying passengers until this requirement is met.
Due 11 May 2004
Resolved 13 May 2004
Operations/Management › Drills/Instruction
Issued 11 May 2004 Resolved
Conduct man overboard and fire fighting drills with attending marine inspector.
Due 11 May 2004
Resolved 28 May 2004
Resolution: Conducted satisfactory man overboard and fire fighting drill.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 11 May 2004 Resolved
Provide guard for forward starboard MDE.
Due 10 June 2004
Resolved 10 June 2004
Resolution: Vsl rep [name withheld] dropped off pictures of guard installed.
Engineering › Bilge Water Management System
Issued 21 August 2003 Resolved
Properly label bilge high level alarms at operating station. LEGACY COMPONENT DESC: High Level Alarm Label
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 August 2003
Resolved 21 August 2003
Lifesaving › Buoyant Apparatus
Issued 21 August 2003 Resolved
Install proper type/length line on all BA waterlights LEGACY COMPONENT DESC: Waterlight line
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 August 2003
Resolved 21 August 2003
Lifesaving › Buoyant Apparatus
Issued 21 August 2003 Resolved
Properly attached all BA's together. LEGACY COMPONENT DESC: painter
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 August 2003
Resolved 25 August 2003
Resolution: BA''s properly attached.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 August 2003 Resolved
Properly install type/length of line on ring life buoy waterlight.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 August 2003
Resolved 21 August 2003
Lifesaving › Buoyant Apparatus
Issued 21 August 2003 Resolved
Properly secure BA waterlight bracket. LEGACY COMPONENT DESC: waterlight bracket
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 August 2003
Resolved 21 August 2003
Engineering › Bilge Water Management System
Issued 21 August 2003 Resolved
Make permanent repairs to lazarette high level alarm. LEGACY COMPONENT DESC: High level alarm
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2003
Resolved 21 August 2003
Electrical › Electric Supply System (service) › Cable
Issued 21 August 2003 Resolved
Install electrical tape around wire screw nuts under operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2003
Resolved 21 August 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 21 August 2003 Resolved
Install grounding strap on fuel fill flex hose. LEGACY COMPONENT DESC: Hose
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2003
Resolved 25 August 2003
Resolution: Grounding straps installed on both P/S fuel tank fill pipes.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 21 August 2003 Resolved
Provide proper type/size of fire extinguishers IAW COI.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 August 2003
Resolved 21 August 2003
Electrical
Issued 21 August 2003 Resolved
Properly dead end electrical wires in tank space. LEGACY COMPONENT DESC: Dead end wires
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2003
Resolved 25 August 2003
Resolution: Wires properly terminated.
Electrical › Lighting (service)
Issued 21 August 2003 Resolved
Provide light cover for light in tank space. LEGACY COMPONENT DESC: cover
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 August 2003
Resolved 21 August 2003
Electrical › Electric Supply System (service)
Issued 21 August 2003 Resolved
Remove wire nuts on wire splicing or properly install electrical box and place inside. LEGACY COMPONENT DESC: wire
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 August 2003
Resolved 25 August 2003
Resolution: Wires properly terminated inside electrical box.
Electrical › Electrical Distribution System (service)
Issued 21 August 2003 Resolved
Properly label distribution panel in E/R. LEGACY COMPONENT DESC: Distribution Panel
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 August 2003
Resolved 25 August 2003
Resolution: Circuit breaker panel properly labeled.
Fire Fighting › Nozzles › Type
Issued 21 August 2003 Resolved
Provide metal nozzle (non-corrosive) for fire hose.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 August 2003
Resolved 21 August 2003
Fire Fighting › Fire Pumps › Impeller
Issued 21 August 2003 Resolved
Prove proper operation of fire pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2003
Resolved 21 August 2003
Engineering › Bilge Water Management System
Issued 21 August 2003 Resolved
Prove proper operation of installed bilge system.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 August 2003
Resolved 21 August 2003
Engineering
Issued 21 August 2003 Resolved
Provide hose for portable hand pump, long enough to reach over the side from all inside void spaces. LEGACY COMPONENT DESC: Hand Pump
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 August 2003
Resolved 21 August 2003
Electrical › Electric Supply System (service)
Issued 21 August 2003 Resolved
Provide/Install electrical box cover for electrical box in lazzarette. LEGACY COMPONENT DESC: Cover
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2003
Resolved 21 August 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 21 August 2003 Resolved
Mount required portable fire extinguishers IAW COI. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 August 2003
Resolved 25 August 2003
Resolution: B-I fire extingisher mounted at operating station.
Lifesaving
Issued 21 August 2003 Resolved
Conduct MOB and Fire fighting drills in the presence of a Marine Inspector. LEGACY COMPONENT DESC: Drills
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 August 2003
Resolved 25 August 2003
Resolution: Sat MOB and fire drills completed by crew.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 August 2003 Resolved
Install proper (60 ft) line on ring life buoy.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 August 2003
Resolved 21 August 2003
Stability › Watertight Integrity
Issued 21 August 2003 Resolved
Properly make void spaces watertight LEGACY COMPONENT DESC: Void Spaces
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 August 2003
Resolved 15 September 2003
Resolution: Received faxed statement from master that fwd watertight blkd is properly sealed.
Stability › Weathertight Integrity
Issued 21 August 2003 Resolved
Make super structure in engine room bulkhead weathertight.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 August 2003
Resolved 21 August 2003
Stability › Weathertight Integrity
Issued 21 August 2003 Resolved
Make pilot house window weathertight. LEGACY COMPONENT DESC: Window
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 August 2003
Resolved 21 August 2003
Electrical › Electric Supply System (service)
Issued 21 August 2003 Resolved
Remove water from battery boxes located in E/R LEGACY COMPONENT DESC: Battery Boxes
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2003
Resolved 22 August 2003
Documentation › Certificates/Documents
Issued 21 August 2003 Resolved
Provide proof of Drug and Alcohol program for all personnel involved with the vessels operation. LEGACY COMPONENT DESC: DAPI
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 August 2003
Resolved 22 August 2003
Documentation › Certificates/Documents
Issued 21 August 2003 Resolved
Provide prrof of Drug and Alcohol program contract. LEGACY COMPONENT DESC: DAPI Contract
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 August 2003
Resolved 21 August 2003
Documentation › Certificates/Documents
Issued 21 August 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 August 2003
Resolved 25 August 2003
Resolution: FCC Station License provided.
Documentation › Certificates/Documents
Issued 21 August 2003 Resolved
Provide FCC Safety Certificate LEGACY COMPONENT DESC: FCC Safety Certificate
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 August 2003
Resolved 25 August 2003
Resolution: FCC Safety Radio Certificate provided.
Documentation › Certificates/Documents
Issued 21 August 2003 Resolved
Provide FCC marine radio operators permit LEGACY COMPONENT DESC: Radio Operators Permit
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 August 2003
Resolved 21 August 2003
Documentation › Markings/Placards
Issued 21 August 2003 Resolved
Post hotline number for Drug and Alcohol program. LEGACY COMPONENT DESC: DAPI Hotline Number
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 August 2003
Resolved 21 August 2003
Documentation › Logs/Records
Issued 21 August 2003 Resolved
Provide and use required log's LEGACY COMPONENT DESC: Logs
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 August 2003
Resolved 22 August 2003
Documentation › Markings/Placards
Issued 21 August 2003 Resolved
Post emergency instructions. LEGACY COMPONENT DESC: Emergency Instructions
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 August 2003
Resolved 25 August 2003
Resolution: Emergency instructions posted.
Navigation
Issued 21 August 2003 Resolved
Provide, up to date, all required navigational publications.. LEGACY COMPONENT DESC: Publications
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 August 2003
Resolved 25 August 2003
Resolution: All nav pubs onboard.
Electrical › Lighting (service)
Issued 21 August 2003 Resolved
Prove proper operation of top mast light (red). LEGACY COMPONENT DESC: Red Light
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2003
Resolved 21 August 2003
Electrical
Issued 21 August 2003 Resolved
Prove proper operation of compass light LEGACY COMPONENT DESC: Compass light
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2003
Resolved 15 September 2003
Resolution: Received faxed receipt for new illuminated compass
Lifesaving
Issued 21 August 2003 Resolved
Provide and mount EPIRB w/hydrostatic release. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2003
Resolved 25 August 2003
Resolution: EPIRB prperly mounted w/hydrostatic release.
Documentation › Certificates/Documents
Issued 21 August 2003 Resolved
Provide EPIRB NOAA registration. LEGACY COMPONENT DESC: NOAA registration
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 August 2003
Resolved 21 August 2003
Electrical › Electrical Distribution System (emergency)
Issued 21 August 2003 Resolved
Provide portable lighting for the E/R and control station. LEGACY COMPONENT DESC: Portable lighting
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 August 2003
Resolved 21 August 2003
Lifesaving
Issued 21 August 2003 Resolved
Conduct MOB and Fire Fighting Drill to the satisfaction of attending Marine Inspector. LEGACY COMPONENT DESC: Drills
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 August 2003
Resolved 25 August 2003
Resolution: Completed (repeated def)
Navigation › Collision/Grounding Avoidance
Issued 29 April 2002 Resolved
REPAIR OR REPLACE MAST HEADLIGHT. LEGACY COMPONENT DESC: Navigation Lights
Action required: 705 - Other - as specified
Due 14 May 2002
Resolved 13 June 2002
Resolution: Corrected
Operations/Management › Drills/Instruction
Issued 29 April 2002 Resolved
CONDUCT MAN OVERBOARD AND FIRE DRILLS. LEGACY COMPONENT DESC: Man Overboard Recovery
Action required: 705 - Other - as specified
Due 30 May 2002
Resolved 13 June 2002
Resolution: Corrected
Communications › Alarms/Indicators
Issued 29 April 2002 Resolved
REPAIR BILGE ALARMS IN THE STEERING AND ENGINE ROOM COMPARTMENTS. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2002
Resolved 14 June 2002
Resolution: Corrected
Lifesaving
Issued 19 June 2001 Resolved
REPLACE EPIRB HYDROSTATIC RELEASE.
Condition: Unknown
Due 19 June 2001
Resolved 29 June 2001
Construction/Loadline
Issued 6 May 1998 Resolved
Properly replace the shear plank and the plank immediately below it port side amidships and the shear plank amidships stbd side above the third scupper and below the forward cabin door.
Condition: Unknown
Due 6 May 1998
Resolved 6 May 1998
Construction/Loadline
Issued 6 May 1998 Resolved
Properly replace the #1 plank on the stbd side forward from the stem aft.
Condition: Unknown
Due 6 May 1998
Resolved 6 May 1998
Construction/Loadline
Issued 23 April 1997 Resolved
Properly attach leashes to all deck hatches to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Navigation
Issued 25 April 1996 Resolved
SECURE BRACKET FOR STEERING HYDRAULIC RAM SUPPORT.
Condition: Unknown
Due 19 August 1996
Resolved 19 August 1996
Construction/Loadline
Issued 25 April 1996 Resolved
RENEW/REPAIR FOREPEAK BILGE VALVE.
Condition: Unknown
Due 19 August 1996
Resolved 19 August 1996
Navigation
Issued 25 April 1996 Resolved
REPLACE RUNNING LIGHTS.
Condition: Unknown
Due 19 August 1996
Resolved 19 August 1996
Navigation
Issued 25 April 1996 Resolved
PROVIDE HYANNIS INNER HARBOR CHART.
Condition: Unknown
Due 19 August 1996
Resolved 19 August 1996
Navigation
Issued 25 April 1996 Resolved
PROVIDE RADIO INSTRUCTION PLACARD, 46 CFR 184.510.
Condition: Unknown
Due 19 August 1996
Resolved 19 August 1996
Lifesaving
Issued 25 April 1996 Resolved
CONDUCT UNDERWAY DRILLS.
Condition: Unknown
Due 19 August 1996
Resolved 19 August 1996
Construction/Loadline
Issued 25 April 1996 Resolved
FREE-UP FOREPEAK VALVE.
Condition: Unknown
Due 19 August 1996
Resolved 19 August 1996
Navigation
Issued 25 April 1996 Resolved
ADJUST OR REPACK STBD RUDDER PACKING GLAND TO ELIMINATE EXCESSIVE LEAKAGE.
Condition: Unknown
Due 19 August 1996
Resolved 19 August 1996
Electrical
Issued 25 April 1996 Resolved
PROVIDE SEPARTE CIRCUIT FOR RADIO PHONE INSTALLATION._x001C_
Condition: Unknown
Due 19 August 1996
Resolved 19 August 1996
Accommodation/Occupational Safety
Issued 7 November 1994 Resolved
PRIOR TO CARRYING PASSENGERS, REFASTEN THE FORWARD STARBOARD MAIN DECK RAIL. TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR BUT NO LATER THAN 15 APR 95.
Condition: Unknown
Due 7 November 1994
Resolved 7 November 1994
Lifesaving
Issued 4 May 1994 Resolved
BOUYANT APPARATUS STOWAGE MUST BE FLOAT FREE. SECURING STRAPS MUST BE EASILY AND QUICKLY RELEASED IF INSTALLED.
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Lifesaving
Issued 4 May 1994 Resolved
MARK STOWAGE OF CHILD LIFE PRESERVER STOWAGE.
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Navigation
Issued 4 May 1994 Resolved
RENEW STERN LIGHT WITH ONE WHICH COMPLIES WITH COLREGS AND RELOCATE STERN LIGHT TO AFTMOST POSITION OF VESSEL PRACTIBLE.
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Lifesaving
Issued 4 May 1994 Resolved
PROVIDE WATERTIGHT CONTAINER FOR STOWAGE OR DISTRESS FLARES.
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Lifesaving
Issued 4 May 1994 Resolved
CONDUCT DRILLS IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Construction/Loadline
Issued 7 May 1993 Resolved
ATTACH CHAIN/CABLE TO AFT SCUTTLE COVER
Condition: Unknown
Due 7 May 1993
Resolved 7 May 1993
Lifesaving
Issued 7 May 1993 Resolved
RELOCATE RING BUOY FOR ACCESS FROM PILOTHOUSE STATION.
Condition: Unknown
Due 7 May 1993
Resolved 7 May 1993
Lifesaving
Issued 7 May 1993 Resolved
CONDUCT UNDERWAY DRILLS IN THE PRESENCE OF A CG INSPECTOR.
Condition: Unknown
Due 7 May 1993
Resolved 7 May 1993
Fire Fighting
Issued 24 October 1991 Resolved
Conduct a fire and boat drill in the presence of a C.G. Marine Inspector prior to carrying passengers.
Condition: Unknown
Due 24 October 1991
Resolved 24 October 1991
Navigation
Issued 9 November 1989 Resolved
REPAIR/MAKE OPERATIONAL VHF-FM RADIO.
Condition: Unknown
Due 9 November 1989
Resolved 9 November 1989
Construction/Loadline
Issued 5 October 1987 Resolved
REPLACE WASTED 1" BILGE SUCTION LINE TO FRWD FORPEAK.
Condition: Unknown
Due 5 October 1987
Resolved 5 October 1987
Electrical
Issued 7 March 1985 Resolved
REPLACE BOTH BATTERY BANKS FOR SHIPS ELECTRICAL SERVICE.
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Engineering
Issued 7 March 1985 Resolved
WRAP ENGINE EXHAUSTS ON BOTH PORT AND STARBOARD ENGINES.
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Navigation
Issued 7 March 1985 Resolved
REPLACE RETAINING PIN ON LINK TO PORT SIDE SHAFT TO STEERING QUADRANT.
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Construction/Loadline
Issued 7 March 1985 Resolved
SEAL GASKET ON AFT ACCESS HATCH TO STEERAGE COMPARTMENT.
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Construction/Loadline
Issued 7 March 1985 Resolved
RE-ATTACH METAL FRAMING AROUND ACCESS HATCH TO FOWARD SECTION OF STEERAGE COMPARTMENTS.
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Electrical
Issued 7 March 1985 Resolved
PLACE METAL GUARDS AROUND LIGHTING FIXTURES IN BOTH HEADS AND IN PASSENGER CABIN.
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Construction/Loadline
Issued 7 March 1985 Resolved
REPLACE MOST FORWARD BRACE TO STARBOARD SIDE SEATING.
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Engineering
Issued 7 March 1985 Resolved
REPLACE CUTLASS BEARING ON PORT AND STARBOARD PROPELLOR SHAFTS.
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985

Casualty record · 1

30 September 2003Routine · role: Involved in a Marine Casualty · 1 injured · activity 1917113
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

BABY BULLET (2003). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record