← All vessels
JONATHAN LEWIS
JONATHAN LEWIS is a 1963 passenger vessel (inspected). The Coast Guard has recorded 74 inspections since 1981, most recently in June 2022, along with 50 deficiencies and 3 casualty investigations between 2007 and 2021.
Records from 1981 to 2022. Most recent: inspection, 2 June 2022.
- Built
- 1963
- Last inspected
- 2 June 2022
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 50 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 3 investigations · 2007–2021
Identity
291370
WDH8487
44463
Flag
UNITED STATES
367380350, 367455460, 367658510 (licence lapsed)
Maury page id
psix-44463
Inspections, by type
…with no type recorded12
Years with a record
39 calendar years (1981–2022)
The 74 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it62 - Simplified, Gross Ton
49 - Simplified, Net Ton
49 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WDH8487MMSI 367658510 · expired · compulsorily equipped · granted 24 February 2015, cancelled 26 April 2025
WDF4754MMSI 367455460 · expired · compulsorily equipped · granted 4 June 2010, cancelled 8 August 2020
WUT2072MMSI 367380350 · cancelled · compulsorily equipped · granted 11 October 2008, cancelled 23 October 2008 · licensed under a name not among this hull’s recorded names (not shown)
WCZ3330MMSI not assigned · expired · compulsorily equipped · granted 14 June 1999, cancelled 15 August 2009 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 74
2 June 2022
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7466091
14 July 2021
Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7257076
14 July 2021
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7257383
7 July 2021
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7248401
12 April 2021
Examination of Repairs · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7162870
16 August 2020
Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7035126
27 May 2020
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6965278
16 March 2020
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6920199
20 June 2019
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6716702
11 April 2019
In-Service Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6660398
14 June 2018
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6443994
25 May 2018
DAPI Audit · COI Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6413943
13 February 2018
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6354028
3 May 2017
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6138145
2 September 2016
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6004952
25 August 2016
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5983055
12 April 2016
Internal Structural Exam · Examination of Repairs · Administrative Inspection · In-Service Inspection · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5847904
24 September 2015
Deficiency Check · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5728384
23 September 2015
Damage Survey · Internal Structural Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5727113
22 September 2015
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5730525
9 October 2014
Annual Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5002342
4 March 2010
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 3689847
30 March 2009
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3443159
19 September 2008
Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3330445
10 May 2008
Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3205728
2 April 2008
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3184612
19 February 2008
Drydock Exam · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3156430
26 July 2007
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3016350
2 April 2007
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2909239
10 August 2006
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 2743107
3 April 2006
Hull Examination · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2613713
21 April 2005
MTSA Verification · Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2339981
21 April 2004
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2055997
11 March 2004
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2023192
28 March 2003
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1765962
19 March 2002
Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1494619
8 July 2001
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 160276
23 March 2001
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1397782
25 October 2000
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1455927
25 August 2000
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 823487
28 January 2000
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 813974
14 December 1999
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1413641
22 January 1999
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1416827
7 January 1999
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 811237
10 December 1998
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1397048
31 March 1998
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1413348
7 June 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 10913
7 February 1997
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1438553
16 February 1996
COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1437130
27 February 1995
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1412759
23 January 1995
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1417686
25 April 1994
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1013933
7 May 1993
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1143181
8 March 1993
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1139660
25 March 1992
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 946925
18 February 1992
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 946923
4 June 1991
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 923252
28 February 1991
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1221225
28 November 1990
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1221592
6 March 1990
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 987767
6 December 1989
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1292346
23 March 1989
Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1031105
20 May 1988
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1042049
24 March 1988
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1299377
30 November 1987
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1000622
23 March 1987
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1331024
18 February 1987
Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1323073
20 March 1986
COI Inspection · Credit Drydock
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1305626
28 March 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 978157
4 March 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 979518
28 March 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 972824
11 March 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1279372
23 March 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 969855
31 March 1981
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1276965
Deficiency record · 50
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 August 2020
Resolved
The OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and equipment are suitable for the service in which they are to be operated. Vessel grounded potentially causing damage to hull. Provided survey report and conduct underway operational test to the satisfaction of attending Marine Inspector prior to carrying passengers.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 March 2020
Resolved
Area of weeping found between garboard plank and second plank on port side approximately 10 feet from stem. Investigate source of weeping and provide objective evidence of watertight integrity.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 March 2020
Resolved
Area of caulking found missing on starboard side at the turn of the bilge. Repair caulking.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 16 March 2020
Resolved
Identified holes in watertight bulkheads in void spaces. Properly seel all watertight bulkheads.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 25 May 2018
Resolved
Renew the reflective material on three PFD's (1 child, 2 adults)
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 August 2016
Resolved
Numerous dead end wires were found throughout the engine room. Either remove or place in a junction box.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 25 August 2016
Resolved
Penetrations in watertight bulkheads were not watertight. Make all penetrations watertight.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 August 2016
Resolved
Extension cords were found on the upper deck for portable lights. Remove extension cord and/or install permanent lighting.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 25 August 2016
Resolved
Anchor was found no properly secured. Secure anchor to not endanger crew and passengers.
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 August 2016
Resolved
Vessel does have a bilge high level alarm in the forepeak space. Install a high level alarm in the forepeak.
Construction/Loadline › Hull › Hull Plating
Issued 23 September 2015
Resolved
Vessel must undergo an out of water drydock/hull inspection to be conducted by a CG marine inspector prior to operation with passengers.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 October 2014
Resolved
Prior to carrying passengers, conduct the overdue annual exam. To be completed to the satisfaction of the attending CG Marine Inspector.
Construction/Loadline › Hull › Hull Plating
Issued 9 October 2014
Resolved
Prior to carrying passengers, make available for inspection the port side of the stem where leaking was discovered while underway.
Construction/Loadline › Hull › Stiffener
Issued 9 October 2014
Resolved
Prior to carrying passengers, make available for inspection the starboard side garboard plank in the #2 void where leaking was discovered while underway.
Construction/Loadline › Hull › Hull Plating
Issued 9 October 2014
Resolved
Prior to carrying passengers, make available for inspection the port side butt block in the machinery space where leaking was discovered while underway.
Fire Fighting › Fire Pumps › Pressure
Issued 9 October 2014
Resolved
Replace the broken fire/bilge pump and test the bilge suctions from each compartment.
Construction/Loadline › Structures › Deck Plating
Issued 9 October 2014
Resolved
Complete repairs to the main deck for the lazarette space.
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 9 October 2014
Resolved
Complete installation of the MSD tank.
Construction/Loadline › Hull › Hull Plating
Issued 4 March 2010
Resolved
Prior to operation vessel is to undergo a credit dry-dock. Vessel COI has been revoked until a credit dry-dock has been completed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 30 March 2009
Resolved
Provide machinery shutdowns IWO the engine room fixed fire extinguishing system.
Electrical › Electric Supply System (service) › Battery Installation
Issued 2 April 2008
Resolved
Provide proper battery box for two batteries in port side engine room.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 2 April 2008
Resolved
Replace life jacket placard on port side box on upper deck.
Construction/Loadline › Hull › Transverse Frame
Issued 19 February 2008
Resolved
Peak tank: Cross brace on frame forward of collision bulkhead is fractured- re-bolt
Engineering › Bilge Water Management System › Piping
Issued 19 February 2008
Resolved
Replace PVC bilge piping with correct metal pipe, where PVC pipe has been used for tempory repair.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 19 February 2008
Resolved
Repair/replace sewage tank.
Lifesaving › Lifebuoys › Size
Issued 2 April 2007
Resolved
Replace 20" life ring with 24" lifering.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 2 April 2007
Resolved
Provide crewmember harness for man overboard recovery.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 22 March 2006
Resolved
Crop and renew fwd bulkhead in engine room
Construction/Loadline › Structures › Deck Plating
Issued 22 March 2006
Resolved
02. Insert fractured deck support on port side in fwd storage space.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 22 March 2006
Resolved
Reduced passengers to 100 until 146 PFD's replaced/repaired. 25% of jackets to be replaced with 25 % per Quarter until all jackets have been replaced by next exam.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 22 March 2006
Resolved
Provide Rigid rescue ladder with platform. Platform to be large enough to hold 2 persons.
Construction/Loadline › Hull › Sheerstrake
Issued 22 March 2006
Resolved
Vessel crew to monitor port and stbd chine in way of eng room and lazz for leakage and make repairs if needed by chalking or haul out. Vessel to keep this office informed and advises with repairs prior to 10 Apr 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 28 March 2003
Resolved
SERVICE COMPANY UNABLE TO PERFORM TEST FOR ANNUAL SERVICE.
Electrical
Issued 10 December 1998
Resolved
Tighten shore tie cable strain relief connector as required by 46 CFR 120.340.
Construction/Loadline
Issued 10 December 1998
Resolved
Refasten deck stiffners in fuel tank compartment as required by 46 CFR 116.100.
Electrical
Issued 10 December 1998
Resolved
Provide cover for fuse panel on aft bulkhead of engine room as required by 46 CFR 120.330.
Electrical
Issued 10 December 1998
Resolved
Properly wire connections in engine room aft bulkhead starboard side as required by 46 CFR 120.340.
Lifesaving
Issued 10 December 1998
Resolved
Repair fuel leak on port fuel system as required by 46 CFR 116.100.
Lifesaving
Issued 10 December 1998
Resolved
Remove oil from bilges as required by 46 CFR 116.800.
Construction/Loadline
Issued 31 March 1998
Resolved
PROPERLY REPAIR FRACTURED FRAME STARBOARD SIDE AFT IN FORWARD COMPASRTMENT.NVIC 7-95.
Construction/Loadline
Issued 31 March 1998
Resolved
RPOPERLY REPAIR LEAKING BUTT BLOCK STARBOARD SIDE AFT IN FORWARD COMPARTMENT. NVIC 7-95
Construction/Loadline
Issued 23 January 1995
Resolved
HULL PLANKING AND FRAMING RENEWED. ALL PLANKING REPLACED WITH CENTRAL AMERICAN MAHOGANY. APPROX 80% OF FRAMING RENEWED, UTILIZING C.A. MAHOGANY._x001C_PLANKING REFASTENED WITH 20 PENNY RING GROOVE BOAT NAILS. _x001C_ SEE VESSELS FILE FOR DETAILS AND LOCATIONS/DIMENSIONS OF REPAIRS.
Lifesaving
Issued 23 March 1987
Resolved
REDISTRIBUTE AND PROPERLY STOW LIFEJACKETS LOCATED ON UPPERDECK.
Construction/Loadline
Issued 23 March 1987
Resolved
AT NEXT CREDIT DRYDOCKING REPAIR OR RENEW PORT & STBD MAIN ENGINE MOUNT GIRDERS WHERE ROTTEN.
Electrical
Issued 23 March 1987
Resolved
PROVIDE ON BOARD REQUIRED AMPMETER FOR GENERATOR.
Construction/Loadline
Issued 23 March 1987
Resolved
PRIOR TO NEXT CREDIT DRYDOCK (DUE 30SEP87) CONDUCT SEA TRIALS FOR A MARINE INSPECTOR CHECK: CHINE SEAM, PORT SIDE IN ENGINE ROOM AND LAZARETTE AND CRACKED PLANK IN FUEL TANK COMPARTMENT PORT SIDE. REMOVE SIDE FRAME CIELINGS AS NECESSARY.
Construction/Loadline
Issued 23 March 1987
Resolved
AT NEXT DRYDOCKING REPLACE ABOVE CRACKED PLANK.
Construction/Loadline
Issued 18 February 1987
Resolved
REMOVE SHORT PLANK (27") PORT SIDE, APPROX (30') FROM BOW, IN 4TH STROKE UPFROM KEEL, AND REPLACE WITH ONE EXTENDING AT LEAST 6 FRAME SPACES.
Engineering
Issued 28 March 1984
Resolved
CG-835 ITEM 2: PROVIDE ONE LINE DIAGRAM OF MODIFIED VENT SYSTEM TO [name withheld], AL. TWO COPIES REQUIRED.
Engineering
Issued 28 March 1984
Resolved
CG-835 ITEM 1: MODIFY FUEL OIL TANK VENTS SO THAT THEY TERMINATE OUTSIDE OFANY ACCOMODATION OR SERVICE SPACE.
Casualty record · 3
26 July 2007Routine · role: Involved in a Marine Casualty · activity 3016350
22 September 2015Routine · role: Involved in a Marine Casualty · activity 5730525
14 July 2021Routine · role: Involved in a Marine Casualty · activity 7257383
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
DIAMOND CITY (2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.