← All vessels
STAVRONISI
STAVRONISI is a 1996 tank ship. The Coast Guard has recorded 41 inspections since 1996, most recently in February 2016, along with 15 deficiencies and 6 operational controls.
Records from 1996 to 2016. Most recent: inspection, 16 February 2016.
- Built
- 1996
- Last inspected
- 16 February 2016
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 15 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9074585 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
SXFT
444635
Flag
GREECE
—
Maury page id
psix-444635
Inspections, by type
…with no type recorded21
Years with a record
18 calendar years (1996–2016)
The 41 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it38667 - Convention (Subpart B), Gross Ton
21281 - Convention (Subpart B), Net Ton
68232 - Dead Weight, Ton
84480 - Displacement, Ton
21281 - Convention (Subpart B), Net Ton
68232 - Dead Weight, Ton
84480 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 41
16 February 2016
COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5815558
12 November 2015
Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5761048
11 October 2014
Deficiency Check · COE-Administrative · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5003108
7 August 2014
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4947262
10 June 2012
COE-Dockside · Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4339338
23 August 2011
Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4124793
21 July 2011
COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4089027
15 January 2011
COE-Dockside
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3927204
21 June 2008
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3245305
20 October 2007
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3084396
19 October 2007
ISPS III Exam · MARPOL Annex I Examination · COC-TVE Annual · MARPOL Annex V Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3084376
7 May 2006
COC-TVE Renew · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2642189
29 January 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2575701
23 May 2005
Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS II Exam · COC-TVE Annual · MARPOL Annex II Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2366247
20 March 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2315106
17 March 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2312996
6 January 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2270225
6 January 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2272577
7 October 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2215803
5 October 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2214347
5 October 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2214356
3 May 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2058313
29 April 2004
Certificate of Compliance · MTSA/ISPS Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2055050
27 June 2003
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1828372
19 April 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1776745
8 August 2002
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1658433
30 April 2002
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1611006
5 April 2002
Certificate of Compliance · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1599729
1 April 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 289185
8 February 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 274573
23 September 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 158572
8 December 1998
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 423333
8 December 1998
Tank Vessel Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 807661
4 March 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 442300
9 January 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 411676
18 September 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 408069
15 September 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 407935
10 September 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 407753
21 August 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 407091
18 March 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 533081
23 August 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 394534
Deficiency record · 15
Lifesaving › Lifeboat Equipment › Food Ration
Issued 21 July 2011
Resolved
All lifeboat equipment shall have food rations kept in airtight packaging, enough to accommodate the lifeboat capacity. Found 34 out of 76 pieces of food rations that were not airtight.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 21 July 2011
Resolved
Each vessel vapor connection flange must have a permanently attached 0.5 inch diam. stud at least 1 inch long projected out from the flange face. The VCS flange faces on both port and stbd manifolds did not have a stud.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 21 July 2011
Resolved
Fire integrity of bulkheads between corridors and galley space must be of A-0 protection. Door from corridors to galley at frame 86 has been repaired with plywood and does not meet A class standards. Provide documentation from Class society attesting to proper repair or replacement of said door.
Deck/Cargo › Crude Oil Washing Systems › Piping
Issued 20 October 2007
Resolved
During cargo transfer, the COW-stripping pipe became pressurized due to a bad valve seat. The pipe burst in an area under the cat-walk, back aft near the superstructure. The burst was in an inaccessible section of pipe, about 4' of which lacked surface preservation. The bad valve was replaced and a blank flange was inserted to prevent temporary use of the pipe until permanent repairs are effected.
Engineering › Generator (propulsion-electric)
Issued 19 April 2003
Resolved
Repair leak in #3 ship service generator salt water cooling pipe. Solas II-1 26.1
Construction/Loadline
Issued 19 April 2003
Resolved
Remove obstructions from emergency generator room vents and replace gasket to make weathertight. ILLC 66 Annex 1/15.
Personnel › Training
Issued 19 April 2003
Resolved
Provide additional training to all ship's crew with cargo operations responsibilities on the use, calibration and testing of tankscopes, O2 meters, LEL meters and MSA toxic detectors IAW STCW 95. Log such training in Training or Ship Log.
Deck/Cargo
Issued 19 April 2003
Resolved
Have a marine chemist certify pumproom as "safe for workers" in order to complete a Coast Guard inspection of pumproom.
Deck/Cargo
Issued 5 April 2002
Resolved
No Marine Chemist Certificate certifying the pumproom to be gas free. Make pumproom available for inspection at next U.S. port. MSM Vol. II Ch. 5.1.
Fire Fighting
Issued 15 September 1997
Resolved
VESSEL FIRE DOORS WOULD NOT SEAL PROPERLY ON DECKS "C" AND "D"; CORRECT PRIOR TO NEXT U.S. PORT.
Deck/Cargo
Issued 10 September 1997
Resolved
CLASS TO ATTEST TO EFFECTIVENESS OF THE CRUDE OIL WASH SYSTEM PRIOR TO 07DEC97. AFTER 07DEC97, THE VESSEL IS NOT TO CARRY AN OIL SUITABLE FOR COWOPERATION IN U.S. WATERS UNLESS THE EFFECTIVENESS HAS BEEN CONFIRMED.
Deck/Cargo
Issued 21 August 1997
Resolved
CLASS TO ATTEST TO EFFECTIVENESS PRIOR TO 7 DEC 97 OR PRIOR TO HER THIRD CARRIAGE OF A CRUDE OIL SUITABLE FOR COW OPERATION. UNTIL THIS IS DONE, VSL IS NOT TO CARRY AN OIL SUITABLE FOR COW OPERATION IN U.S. WATERS.
Deck/Cargo
Issued 21 August 1997
Resolved
INSTALL AND PROVE OPERATION OF AN AUTOMATIC SHUTDOWN DEVICE FOR THE INERT GAS SYSTEM LOSS OF NORMAL WATER SUPPLY TO THE DECK WATER SEAL IAW 46 CFR 32.53-70(b)(3) PRIOR TO THE NEXT U.S. PORT.
Deck/Cargo
Issued 21 August 1997
Resolved
SERVICE AND PROVE OPERATION OF ALL CARGO TANK P/V VALVES PRIOR TO THE NEXT U.S. PORT.
Deck/Cargo
Issued 21 August 1997
Resolved
MAKE PERMANENT REPAIRS TO THE HOLES IN HYDRAULIC LINES 2ND LEVEL CARGO PUMPROOM PRIOR TO THE NEXT U.S. PORT.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.