MAURY USCG vessel records Sign in
← All vessels

MARY M III

MARY M III is a 1963 passenger vessel (inspected). The Coast Guard has recorded 59 inspections since 1985, most recently in November 2016, along with 115 deficiencies.

Records from 1985 to 2016. Most recent: inspection, 27 November 2016.

Built
1963
Last inspected
27 November 2016
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBN2216
Flag
UNITED STATES
367163150 (licence lapsed)
Maury page id
psix-44465

Inspections, by type

…with no type recorded4
Years with a record 30 calendar years (1985–2016)
The 59 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)45.2 ft × 15.1 ft × 5.4 ft
Registered tonnagegross 26 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDEEBOLD & ADAMS BOAT WRKS · ATLANTIC CITY, NJ, UNITED STATES · built 1963
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPUNTA GORDA, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WBN2216MMSI 367163150 · expired · voluntarily equipped · granted 27 January 2007, cancelled 15 April 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 59

27 November 2016 Type not recorded
No type recorded · Station Ocean City · USCG East District (CGD-E) · Activity 6048156
25 March 2014 Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4839124
21 February 2012 COI Inspection · Administrative Inspection · Internal Structural Exam · DAPI Audit · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4248161
1 December 2011 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4199673
1 February 2010 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3671783
17 March 2009 Hull Examination · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3434234
6 March 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3174361
16 October 2007 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3077527
15 March 2007 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2888230
28 March 2006 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2608763
24 October 2005 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2519441
23 March 2005 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2316799
18 May 2004 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2072757
31 March 2004 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2047713
9 December 2003 Type not recorded
No type recorded · USCGC FINBACK (WPB 87314) · USCG Northeast District (CGD-NE) · Activity 1997303
20 October 2003 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1927826
28 April 2003 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1798095
26 March 2002 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1602085
15 November 2001 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1075779
13 August 2001 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1070217
12 April 2001 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1061936
21 February 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1059070
4 April 2000 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 816746
23 November 1999 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1365471
30 March 1999 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 787207
30 March 1999 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 818661
17 April 1998 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 794438
21 October 1997 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1112888
1 April 1997 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1093822
24 March 1997 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1097696
1 April 1996 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1079045
1 September 1995 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 876899
12 April 1995 Re-Inspection · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 869212
20 October 1994 Hull Examination · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 871735
11 October 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 863434
21 April 1994 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 857214
30 March 1994 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 858908
19 July 1993 Deficiency Check · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 846204
1 April 1993 Deficiency Check · COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 832505
20 July 1992 Deficiency Check · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 947728
2 April 1992 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 944951
22 July 1991 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 936317
3 April 1991 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1238410
23 July 1990 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1230269
5 April 1990 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 914280
12 May 1989 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 890929
9 May 1989 Drydock Extension
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1042292
26 April 1989 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1039164
6 April 1989 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 897830
19 April 1988 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1339806
8 April 1988 Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1210449
14 October 1987 Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1017470
7 April 1987 COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1005848
5 May 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 986434
30 April 1986 Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1309297
15 April 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1309294
3 April 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1306922
12 March 1986 Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1306921
4 April 1985 Deficiency Check · Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1289732

Deficiency record · 115

Stability › Intact Righting Energy › General
Issued 1 December 2011 Resolved
01 DEC 2011: Issued CG-835 with new passenger capacity due to change in AAWPP effective 01 Dec 2011.
Action required: 705 - Other - as specified
Resolved 23 March 2012
Resolution: O/O contacted unit requesting passenger reduction to come into compliance with AAWPP. All sat.
Communications › Radio Communications › EPIRB
Issued 1 February 2010 Resolved
Vessel is restricted to 3 nautical miles off the coast until EPIRB registration is renewed and above deficiencies are corrected.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2010
Resolution: Attended vessel to witness proper registration of EPIRB.
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 January 2010 Resolved
Prove proper operation of bilge high level alarms (Forepeak and Lazarrette) prior to carrying passengers, to the satisfaction of marine inspector.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2010
Resolution: Attended vessel for satisfactory test of bilge high level alarms.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 28 January 2010 Resolved
Prove accommodation space B-II extinguisher is properly serviced prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 February 2010
Resolution: Proof of service provided by owner.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 17 March 2009 Resolved
Provide 6 year maintenance recipt on B-II extinguisher in accomodation space.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2009
Resolution: Recieved recipt of service on extinguisher.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 17 March 2009 Resolved
Replace hose clamp on starboard main diesel engine exhaust.
Condition: Improper/Lack of Maintenance
Due 20 April 2009
Resolved 21 April 2009
Resolution: Hose clamp installed on exhaust.
Lifesaving › Buoyant Apparatus › Lifeline
Issued 17 March 2009 Resolved
Repair/Replace lifeline on buoyant apparatus and waterlight and properly restowe painter line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 April 2009
Resolution: Lifeline was replaced on buoyant apparatus and waterlight, and painter was properly restowed.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 March 2009 Resolved
Restencil life ring on second deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 April 2009
Resolution: Life ring was properly restenciled.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 17 March 2009 Resolved
Replace three PFD lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 April 2009
Resolution: PFD lights replaced and installed on PFD''s.
Fire Fighting › Fire Bucket › Quantity
Issued 17 March 2009 Resolved
Provide one (1) fire bucket.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 21 April 2009
Resolution: One fire bucket was placed into service.
Fire Fighting › Fire Bucket › Availability
Issued 31 March 2008 Resolved
The vessel has numerous buckets onboard, but only one has the correct lanyard and labeling. Provide two fire buckets prior to 07Apr08.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2008
Resolved 2 April 2008
Resolution: O/O labled two buckets and attached lanyard.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 31 March 2008 Resolved
Re-stencil the ring buoy with the vessel's name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2008
Resolved 2 April 2008
Resolution: O/O re-stenciled ring buoy with vessel''s name.
Operations/Management › Drills/Instruction › Not Conducted
Issued 31 March 2008 Resolved
The vessel has not conducted any drills since October, the vessel must conduct drills prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2008
Resolution: Conducted satisfactory MOB and fire drills.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 31 March 2008 Resolved
Missing donning placard for TYPE I PFD's. The vessel must provide donning placard prior to 07Apr08.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2008
Resolved 2 April 2008
Resolution: O/O placed donning placard onboard.
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 31 March 2008 Resolved
The vessel's light list, Coastal Pilot and charts are out of date. Replace prior to 07Apr08.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2008
Resolved 8 April 2008
Resolution: O/O faxed in receipt of purchased items.
Construction/Loadline › Hull › Hull Plating
Issued 16 October 2007 Resolved
Provide repair proposal and affect permanent repairs to two leaks in chine area in lazarette compartment prior to 31MAR2008.
Due 31 March 2008
Resolved 31 March 2008
Resolution: Verified repairs on 06 Mar 08 and performed check ride on 31Mar08, all sat.
Engineering › Lubricating Oil Service System › Hose
Issued 15 March 2007 Resolved
Replace cracked hydraulic line on port MDE and correct all chaffing on port & stbd MDEs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2007
Resolved 17 May 2007
Resolution: Hydraulic line replaced and chaffing issues corrected.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 15 March 2007 Resolved
Provide 3 lifejacket lights. Vessel restricted to 27 total adults while operating coastwise after sunset.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 March 2007
Resolved 17 May 2007
Resolution: 3 L/J lights provided.
Documentation › Certificates/Documents › FCC SSL
Issued 15 March 2007 Resolved
Provide valid FCC Safety Certificate. Vsl restricted from operating beyond 1000' from shore until corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2007
Resolved 17 May 2007
Resolution: Valid FCC Safety Cert provided.
Operations/Management › Drills/Instruction › Not Conducted
Issued 15 March 2007 Resolved
Provide proof of log book entries for drills and lifesaving equipment inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 17 May 2007
Resolution: Log book provided.
Navigation › Piloting/Steering › Marine Charts
Issued 15 March 2007 Resolved
Provide corrected or new chart #12300.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 17 May 2007
Resolution: New chart #12300 provided.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 March 2007 Resolved
Provide aspirin w/ valid dates.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 17 May 2007
Resolution: Valid aspirin provided.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 15 March 2007 Resolved
Correct attachments of lifefloat painter, waterlight lanyard, and lifebuoy. Lifefloat painter not secured around body, waterlight lanyard not secured around body, and lifebuoy line not secured around body.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 17 May 2007
Resolution: Lifefloat painter, waterlight lanyard, and lifebuoy attachments corrected.
Stability › Weathertight Integrity › General
Issued 28 March 2006 Resolved
Broken aft window in pilot house (port side).
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 March 2006
Resolved 30 March 2006
Resolution: Aft window in pilot house replaced.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 28 March 2006 Resolved
Vsl. did not have two operable flashlights.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 March 2006
Resolved 30 March 2006
Resolution: Two operable flashlights provided.
Fire Fighting › Fire Bucket › Availability
Issued 28 March 2006 Resolved
Vsl. did not have (3) 2.5 gal fire buckets.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 March 2006
Resolved 30 March 2006
Resolution: (3) 2.5 gal fire buckets with lanyards provided.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 28 March 2006 Resolved
Wet exhaust leak on port engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 March 2006
Resolved 30 March 2006
Resolution: Wet exhaust pipe on port engine replaced with new copper pipe.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 28 March 2006 Resolved
Rope ladder for emergency embarkation wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 March 2006
Resolved 30 March 2006
Resolution: Rope ladder repaired satisfactorily.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 28 March 2006 Resolved
Bilge alarm panel in bridge not labeled.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 March 2006
Resolved 30 March 2006
Resolution: Bilge alarm panel in bridge properly labeled with spaces served.
Engineering › Bilge Water Management System
Issued 31 March 2004 Resolved
TEST BILGE ALARM IN LAZARETTE. LEGACY COMPONENT DESC: Alarm
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2004
Resolution: WITNESSED SATISFACTORY TESTING.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 31 March 2004 Resolved
SERVICE B-1 AT OPERATING STATION.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2004
Resolution: WITNESSED SERVICED SUBJECT B-1.
Electrical › Mast
Issued 31 March 2004 Resolved
RENEW BURNED OUT LIGHTS ON DECK/CABIN. LEGACY COMPONENT DESC: DECK/CABIN LIGHTING
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 29 April 2004
Resolution: Renewed all deck/cabin lights.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 31 March 2004 Resolved
REPAIR PORT ENGINE RPM GAUGE. LEGACY COMPONENT DESC: PORT ENGINE RPM GAUGE
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 29 April 2004
Resolution: Repaired port engine RPM gauge.
Navigation › Piloting/Steering
Issued 31 March 2004 Resolved
PROVIDE ONE FLASHLIGHT AT OPERATING STATION. LEGACY COMPONENT DESC: FLASHLIGHT
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 29 April 2004
Resolution: Provide one flashlight at operating station.
Lifesaving › Visual Distress Signals (General)
Issued 31 March 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 18 May 2004
Resolution: Recieved copy of invoice for new EPRIB and battery. Cleared sat.
Lifesaving › Buoyant Apparatus
Issued 31 March 2004 Resolved
REPLACE RING BOUY. LEGACY COMPONENT DESC: RING BOUY
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2004
Resolution: WITNESSED SATISFACTORY RING BOUY.
Navigation › Piloting/Steering
Issued 31 March 2004 Resolved
PROVIDE CURRENT LIGHT LIST. LEGACY COMPONENT DESC: Coast Guard Light List
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 29 April 2004
Resolution: Provide current Light List.
Operations/Management › Drug and Alcohol Testing
Issued 31 March 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 29 April 2004
Resolution: Provide current drug paperwork.
Lifesaving
Issued 31 March 2004 Resolved
RENEW EXPIRED ITEMS (3) IN FIRST AID KIT. LEGACY COMPONENT DESC: FIRST AID KIT
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 29 April 2004
Resolution: Replaced expired items in kit.
Construction/Loadline › Hull
Issued 31 March 2004 Resolved
REPLACE SHEER CLAMP ON STBD SIDE ENGINE ROOM. LEGACY COMPONENT DESC: SHEER CLAMP
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 29 April 2004
Resolution: Replaced sheer clamp on stc side Engine Room.
Construction/Loadline › Hull
Issued 31 March 2004 Resolved
REPLACE "I" BEAM MEMBER FORWARD OF PORT ENGINE. MEMBER NOT STRUCTURAL TO VSL. LEGACY COMPONENT DESC: "I" BEAM
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 29 April 2004
Resolution: Replaced "I" beam.
Construction/Loadline › Hull
Issued 31 March 2004 Resolved
SCRAP & PRESERVE ANGEL HAIR IN ENGINE ROOM. LEGACY COMPONENT DESC: ANGEL HAIR
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 29 April 2004
Resolution: Completed.
Construction/Loadline › Hull
Issued 20 October 2003 Resolved
Prior to carrying passengers. Conduct an underway check ride.
Due 20 October 2003
Resolved 21 October 2003
Resolution: Conducted an underway check ride. Visually inspected all compartments. All sat.
Construction/Loadline › Hull
Issued 20 October 2003 Resolved
Preserve all fasteners located in engine room, bow and steering space.
Due 21 November 2003
Resolved 20 November 2003
Resolution: Inspected all spaces. All fasteners coated and preserved. All sat.
Documentation › Certificates/Documents
Issued 28 April 2003 Resolved
Renew Marine Radio Operator Permit.
Due 16 May 2003
Resolved 16 May 2003
Resolution: Revieved faxed copy of temporary marine radio operator permit.
Documentation
Issued 28 April 2003 Resolved
Post Waste Management Plan.
Due 16 May 2003
Resolved 16 May 2003
Resolution: Posted Waste Management Plan.
Navigation
Issued 28 April 2003 Resolved
Provide current tide tables for area.
Due 16 May 2003
Resolved 16 May 2003
Resolution: Provided tide tables.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 28 April 2003 Resolved
Provide 1 additional adult life jacket. Passenger count limited to 29 passengers.
Due 16 May 2003
Resolved 16 May 2003
Resolution: Purchased new life jacket.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 28 April 2003 Resolved
Service all fire fighting extinguishers and replace B-II in aft cabin. Issued no sail. LEGACY COMPONENT DESC: Condition
Due 28 April 2003
Resolved 29 April 2003
Resolution: Serviced all fire fighting extinguishers. Inspected sat.
Lifesaving
Issued 28 April 2003 Resolved
Replace waterlight line on ring buoy.
Due 28 April 2003
Resolved 29 April 2003
Resolution: Installed new line on water light.
Lifesaving › Buoyant Apparatus
Issued 28 April 2003 Resolved
Provide new retro-tape, grab lines, net lines and stencil life float and oars wtin vessel name.
Due 28 April 2003
Resolved 29 April 2003
Resolution: Corrected all items issued for life float.
Stability › Water on Deck
Issued 28 April 2003 Resolved
Repair leaking butt block on starboard side in # 1 compartment.
Due 28 April 2003
Resolved 29 April 2003
Resolution: Conducted underway check ride. No leaks were observed in # 1 compartment. Re-fastened leaking butt block.
Lifesaving
Issued 28 April 2003 Resolved
Pump out bilge in lower cabin for inspection. Issued no sail
Due 28 April 2003
Resolved 29 April 2003
Resolution: Pumped out bilge. Conducted underway check ride. All sat.
Engineering
Issued 28 April 2003 Resolved
Repair leak on port side wet exhaust. Issued no sail.
Due 28 April 2003
Resolved 29 April 2003
Resolution: Leak repaired. Conducted underway check ride. All sat.
Engineering
Issued 28 April 2003 Resolved
Replace MDE wet exhaust bracket on starboard side.
Due 28 April 2003
Resolved 16 May 2003
Resolution: Installed new brackets. Inspected sat.
Documentation
Issued 28 April 2003 Resolved
Provide proof of user fee.
Due 28 April 2003
Resolved 16 May 2003
Resolution: All Sat.
Engineering
Issued 28 April 2003 Resolved
Repair/Replace starboard engine water temp and port engine RPM gauges
Due 28 April 2003
Resolved 16 May 2003
Resolution: Provided receipt of purchase for 2 new gauges.
Personnel
Issued 28 April 2003 Resolved
Install mail box on pier for passenger count.
Due 28 April 2003
Resolved 16 May 2003
Resolution: Installed mail box on pier.
Lifesaving
Issued 28 April 2003 Resolved
Proof operation of # 3 bilge alarm. Issued no sail.
Due 28 April 2003
Resolved 29 April 2003
Resolution: Tested # 3 bilge alarm. All sat.
Engineering › Freshwater System (jacketwater cooling) › Fitting
Issued 26 March 2002 Resolved
Install double hose clamps on exhaust hoses.
Condition: Unknown
Due 28 March 2002
Resolved 28 March 2002
Resolution: Installed hose clamps on hoses.
Accommodation/Occupational Safety
Issued 26 March 2002 Resolved
Install lanyard on aft hatch.
Condition: Unknown
Due 28 March 2002
Resolved 28 March 2002
Resolution: Installed lanyard on aft hatch.
Accommodation/Occupational Safety
Issued 26 March 2002 Resolved
Stencil pilothose ladder with "no passengers permitted".
Condition: Unknown
Due 28 March 2002
Resolved 28 March 2002
Resolution: Posted placard.
Engineering › Fuel Oil Service System › Valve
Issued 26 March 2002 Resolved
Label emergency fuel shut-off open/closed postion.
Condition: Unknown
Due 28 March 2002
Resolved 28 March 2002
Resolution: Labeld emergency fuel shut-offs.
Electrical
Issued 26 March 2002 Resolved
Replace bilge alarm light for aft compartment on bilge alarm panel.
Due 26 March 2002
Resolved 28 March 2002
Resolution: Installed new light.
Lifesaving
Issued 26 March 2002 Resolved
Stencil life jacket stowage locker with number of lifejackets.
Due 28 March 2002
Resolved 28 March 2002
Resolution: Stenciled life jacket locker with correct number of life jackets.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 26 March 2002 Resolved
Install 3 lights on life jackets.
Condition: Unknown
Due 28 March 2002
Resolved 28 March 2002
Resolution: Installed 3 new lights on life jackets.
Accommodation/Occupational Safety
Issued 26 March 2002 Resolved
Post COI in pilot house.
Due 28 March 2002
Resolved 28 March 2002
Resolution: Posted COI.
Lifesaving
Issued 26 March 2002 Resolved
Provide passenger count for all trips.
Due 28 March 2002
Resolved 28 March 2002
Resolution: Installed mail box on pier.
Engineering
Issued 26 March 2002 Resolved
Provide operation of bilge system.
Due 28 March 2002
Resolved 28 March 2002
Resolution: Performed operation of bilge system.
Lifesaving
Issued 12 April 2001 Resolved
REPLACE RETRO-REFLECTIVE TAPE ON ONE LIFE JACKET & STENCIL VESSEL NAME ON SAME.
Condition: Unknown
Due 12 April 2001
Resolved 13 August 2001
Lifesaving
Issued 12 April 2001 Resolved
REPLACE RETRO-REFLECTIVE TAPE ON LIFE RING
Condition: Unknown
Due 12 April 2001
Resolved 13 August 2001
Lifesaving
Issued 12 April 2001 Resolved
PROVE PROPER OPERATION OF LIFE FLOAT LIGHT.
Condition: Unknown
Due 12 April 2001
Resolved 13 August 2001
Engineering
Issued 12 April 2001 Resolved
REPAIR LEAKING OIL PUMP GASKET
Condition: Unknown
Due 12 April 2001
Resolved 13 August 2001
Electrical
Issued 12 April 2001 Resolved
PROPERLY SECURE ALL LOOSE WIRING CURRENTLY LYING IN E/R BILGE.
Condition: Unknown
Due 12 April 2001
Resolved 6 September 2001
Construction/Loadline
Issued 12 April 2001 Resolved
PROVE PROPER OPERATION OF BILGE ALARMS
Condition: Unknown
Due 12 April 2001
Resolved 13 August 2001
Lifesaving
Issued 21 February 2001 Resolved
Effective 11 March 2001; This vessel may not proceed more than 3 miles fromshore with passengers for hire between 01 November and 31 May.
Condition: Unknown
Due 12 April 2001
Resolved 1 May 2001
Unknown
Issued 4 April 2000 Resolved
PRESENT VESSEL FOR OPERATIONAL TEST OF FIRE/BILGE PUMP PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 18 April 2000
Resolved 11 May 2000
Unknown
Issued 4 April 2000 Resolved
REPAIR BILGE ALARM PANEL AND PRESENT FOR FULL FUNCTIONAL TEST.
Condition: Unknown
Due 18 April 2000
Resolved 11 May 2000
Engineering
Issued 23 November 1999 Resolved
RENEW METAL ENGINE BRACKETS (STBD SIDE #4 FROM FWD & PORT #1 FROM FWD)
Condition: Unknown
Due 23 November 1999
Resolved 23 November 1999
Construction/Loadline
Issued 23 November 1999 Resolved
REPLACE WASTED BOLT IN ENGINE ROOM KNEE, PORT SIDE #7 FROM FORWARD.
Condition: Unknown
Due 23 November 1999
Resolved 23 November 1999
Engineering
Issued 23 November 1999 Resolved
REPLACE PORT SIDE SHAFT CUTLASS BEARING
Condition: Unknown
Due 23 November 1999
Resolved 23 November 1999
Navigation
Issued 23 November 1999 Resolved
RENEW RUDDER ASSEMBLY "L" BRACKET PORT SIDE.
Condition: Unknown
Due 23 November 1999
Resolved 23 November 1999
Construction/Loadline
Issued 23 November 1999 Resolved
EXAMINE ALL PORT SIDE KNEE BOLTS & RENEW WASTED BOLTS/NUTS
Condition: Unknown
Due 23 November 1999
Resolved 23 November 1999
Documentation
Issued 1 April 1996 Resolved
PROVIDE DOCUMENTATION THAT THE DRUG TESTING REPORT FOR 1995 HAS BEEN FORWARDED TO COAST GUARD HEADQUARTERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 May 1996
Resolved 5 April 1996
Construction/Loadline
Issued 12 April 1995 Resolved
REPAIR LEAK IN BILGE PIPING SYSTEM LOCATED IN MACHINERY COMPARTMENT.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Lifesaving
Issued 12 April 1995 Resolved
RENEW RETRO-REFLECTIVE TAPE ON BOTH LIFEFLOATS.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Lifesaving
Issued 12 April 1995 Resolved
RENEW GRABLINE ON RING BUOY.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Fire Fighting
Issued 12 April 1995 Resolved
PROVIDE ONE B-I TYPE PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Engineering
Issued 12 April 1995 Resolved
RENEW FUEL TANK VENT SCREEN (30 X 30 MESH).
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Lifesaving
Issued 12 April 1995 Resolved
VESSEL RESTRICTED TO 28 TOTAL PERSONS UNTIL 2 ADULT LIFEJACKETS ARE PROVIDED.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Navigation
Issued 12 April 1995 Resolved
PROVIDE WRITTEN GARBAGE WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Navigation
Issued 12 April 1995 Resolved
CENTER BULB IN PORT NAVIGATION LIGHT.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Navigation
Issued 12 April 1995 Resolved
PROVIDE FCC CODE OF FEDERAL REGULATIONS (47 CFR 80).
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Construction/Loadline
Issued 11 October 1994 Resolved
CHECK ALL FASTENERS IN WAY OF THE ENGINE COMPARTMENT FLOOR KNEES AT THE CHINES AND IN THE STERN COMPARTMENT IN WAY OF THE DECK FRAME SUPPORTS. RENEW FRAME FASTENERS WHERE WASTED.
Condition: Unknown
Due 11 October 1994
Resolved 11 October 1994
Construction/Loadline
Issued 11 October 1994 Resolved
REMOVE TEMPORARY PLUGGED THRU HULL FITTINGS (3 PORT, 2 STBD) APPROX 1 FOOT_x001C_ABOVE THE WATERLINE IN THE ENGINEROOM AND PERMANENTLY CLOSE WITH WOODEN PLUG, SEALANT AND WOODEN BACKING BLOCK.
Condition: Unknown
Due 11 October 1994
Resolved 11 October 1994
Construction/Loadline
Issued 11 October 1994 Resolved
PRIOR TO CARRYING PASSENGERS AFTER 31 JANUARY 1995, MAKE THE VESSEL AVAILABLE FOR AN UNDERWAY RIDE IN THE PRESENCE OF A USCG MARINE INSPECTOR (TO COMPLETE CREDIT HULL EXAM STARTED ON 11 OCTOBER 1994, WITH A HULL EXAM CREDIT DATE OF 11 OCTOBER 1994).
Condition: Unknown
Due 11 October 1994
Resolved 11 October 1994
Construction/Loadline
Issued 11 October 1994 Resolved
PROPERLY INSTALL WOODEN PLUG, SEALANT AND WOODEN BACKING BLOCK WHERE EXISTING PLUG HAS BEEN DRIVEN IN THE BOTTOM PLANKING PORT FORWARD OF THE KEEL IN THE FIRST BAY, ENGINE ROOM.
Condition: Unknown
Due 11 October 1994
Resolved 11 October 1994
Navigation
Issued 30 March 1994 Resolved
PROVIDE A CURRENT MAGNETIC COMPASS DEVIATION TABLE.
Condition: Unknown
Due 30 March 1994
Resolved 30 March 1994
Lifesaving
Issued 30 March 1994 Resolved
PRIOR TO CARRYING MORE THAN 26 ADULT PASSENGERS, PROVIDE TWO (2) ADDITIONALUSCG APPROVED (TYPE I) LIFEJACKETS.
Condition: Unknown
Due 30 March 1994
Resolved 30 March 1994
Lifesaving
Issued 1 April 1993 Resolved
NUMBER OF PASSENGERS RESTRICTED TO SIXTEEN (16) ADULTS, UNTIL TWELVE(12) ADDITIONAL ADULT USCG APPROVED TYPE I LIFEJACKETS PROVIDED.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Construction/Loadline
Issued 1 April 1993 Resolved
RENEW FORWARD PORT & STARBOARD STRUT SUPPORT BLOCKS.
Condition: Unknown
Due 1 April 1993
Resolved 1 April 1993
Documentation
Issued 1 April 1993 Resolved
PROVIDE DOCUMENTATION TO SHOW COMPLIANCE WITH DRUG PROGRAM; INCULDING TRAINING, MEDICAL REVIEW OFFICER DESIGNATED, TESTING, AND PROOF OF MEMBERSHIP WITH CONSORTIUM.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Navigation
Issued 2 April 1992 Resolved
PROVIDE UPDATED NAVIGATION RULES (1990)
Condition: Unknown
Due 2 May 1992
Resolved 20 July 1992
Construction/Loadline
Issued 2 April 1992 Resolved
AT NEXT HULL EXAM (DRYDOCKING) OPEN THREE ACCESSES IN THE SECOND COMPTARTMENT'S SIDE CEILING TO ALLOW FOR AN EXAM OF A THREE (03) FRAME AREAON EITHER THE PORT OR STBD SIDE. TWO ACCESS OPENINGS ARE REQUIRED UNDER THE BENCH SEATING AND ONE ACCESS IN THE CABINET ABOVE THE SEATING.
Condition: Unknown
Due 2 May 1992
Resolved 20 July 1992
Navigation
Issued 2 April 1992 Resolved
PROVIDE A CLASS "A" EPIRB MANUFACTURED AFTER 01 OCTOBER 1988. VESSELS ROUTE RESTRICTED TO COASTWISE NOT MORE THAN 20 NAUTICAL MILES FROM A HARBOROF SAFE REFUGE UNTIL ABOVE EPIRB PROVIDED AND ACCEPTED.
Condition: Unknown
Due 8 May 1992
Resolved 20 July 1992
Navigation
Issued 22 July 1991 Resolved
RPLACE THE STARBOARD RUDDER SUPPORT BLOCKS WHERE FRACTURED.
Condition: Unknown
Due 30 July 1991
Resolved 30 July 1991
Construction/Loadline
Issued 22 July 1991 Resolved
REPLACE THE MISSING WOODEN SCARF JOINT IN KEEL AFT END.
Condition: Unknown
Due 30 July 1991
Resolved 30 July 1991
Engineering
Issued 22 July 1991 Resolved
REPLACE THE PORT AND STARBOARD RUBBER CUTLESS BEARINGS,WHERE WORN BEYOND_x001C_ FIFTY PERCENT.
Condition: Unknown
Due 30 July 1991
Resolved 30 July 1991
Lifesaving
Issued 3 April 1991 Resolved
REPAIR OR REPLACE THE REQUIRED HAND OPERATED FIRE/BILGE PUMP PRESENTLY IN-_x001C_OPERABLE.
Condition: Unknown
Due 3 April 1991
Resolved 3 April 1991
Lifesaving
Issued 6 April 1989 Resolved
PROVIDE TWENTY-FOUR (24) PFD LIGHTS WHERE MISSING ON ADULT LIFE JACKETS.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Engineering
Issued 6 April 1989 Resolved
REPLACE ALL NON CG APPROVED FLEXIBLE FUEL LINES ON MAIN DIESEL ENGINES WITHCG APPROVED TYPE.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Lifesaving
Issued 8 April 1988 Resolved
PROVIDE ONE ADDITIONAL LIFEJACKET. VESSEL RESTRICTED TO 50 PERSONS WHILE ON A COASTWISE VOYAGE.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Engineering
Issued 7 April 1987 Resolved
PROVIDE FUEL TANK DIAGRAM SHOWING CONSTRUCTION DETAILS, BAFFLES, ETC. AS REQUIRED BY 46 CFR 182.20-25, AND INSTALLATION DETAILS OF THE TANK AND ANY NEW FUEL PIPING. PREVIOUS INSPECTION BOOKS SHOW VESSEL HAD 650 GALLON TANK. 1987 BOOK SHOW 300 GALLON TANK.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Construction/Loadline
Issued 30 April 1986 Resolved
DETERMINE CAUSE AND EFFECT CORRECTION TO REASON FOR HAVING OIL IN BILGE IN FORWARD COMPARTMENT.
Condition: Unknown
Due 30 April 1986
Resolved 30 April 1986
Documentation
Issued 12 March 1986 Resolved
OBTAIN VALID FCC OPERATOR'S LICENSE PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 12 March 1986
Resolved 12 March 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.