Records from 2008 to 2026. Most recent: inspection, 15 April 2026.
Inspection history · 29
15 April 2026
Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8324761
3 June 2025
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8151341
9 April 2025
Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8116609
11 February 2025
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8057299
11 June 2024
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8014083
23 June 2023
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7804071
9 May 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7684899
31 January 2023
Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7595744
26 July 2022
Examination of Repairs · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7516799
26 April 2022
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7438867
3 May 2021
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7188075
3 February 2021
Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7134975
1 December 2020
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7104486
31 July 2020
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7021200
11 June 2020
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6973352
7 February 2020
In-Service Inspection · Construction Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6910559
24 January 2020
Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6895807
8 October 2019
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6833032
4 June 2019
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6702096
26 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6548942
21 July 2018
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6492263
22 May 2018
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6420382
10 April 2018
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6384210
24 August 2017
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6255643
14 June 2017
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6175628
27 July 2016
Damage Survey · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5957097
13 May 2016
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5876523
9 May 2016
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5872940
29 March 2016
Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5835325
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 15 April 2026
Resolved
Vessel has 02 radios with DSC capabilities. Label radio "EMERGENCY RADIO USE THIS RADIO FOR DISTRESS CALLS" or equivalent wording.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2026
Resolved 11 May 2026
Resolution: Received photo. All SAT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 April 2026
Resolved
Vessel's autopilot hydraulic pump is leaking. Fix leak on pump and notify local OCMI once completed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2026
Resolved 22 April 2026
Resolution: Received photo of repairs to auto pilot DCV. All SAT
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 15 April 2026
Resolved
Engine room is missing CO2 labeling. Label entrance to engine room with “WHEN ALARM SOUNDS-VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED”. Notify local OCMI once completed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2026
Resolved 11 May 2026
Resolution: Received photo. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 May 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Control box for refrigeration system in engine space is open with exposed wiring. Must correct to satisfaction of USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2023
Resolved 25 May 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 January 2023
Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations. Vessel unable to fulfill under way sea trial requirement.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 February 2023
Resolved 15 February 2023
Resolution: Sec San Diego attended vessel. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 July 2022
Resolved
VSL STARBOARD SHAFT SEPARATED AT THE COUPLING.
VSL IS REQUIRED TO HAUL OUT TO MAKE NECESSARY REPAIRS AND EVALUATE RUDDER AND PROPELLER DAMAGE PRIOR TO DEPARTURE/CARRYING PASSENGERS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2022
Resolution: New shaft installed and tested. ALL SAT
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 26 April 2022
Resolved
Abandoned ship, man overboard and fire drills and training shall be logged for review by the USCG upon request. There was a gap in the logs of one year where the drills were not logged. Informed operator that all drills performed by the crew must be logged. Deficiency was corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 26 April 2022
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 April 2022
Resolved
The fire pump outlet shall be fitted with a pressure gauge. Gauge on the fire pump was not operable at time of inspection. Must repair/replace to satisfaction of the USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2022
Resolved 12 May 2022
Resolution: Received picture of newly installed & operational guage.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2021
Resolved
Galley outlet was found worn and discolored at prong entrance. Replace receptacle with in-kind new outlet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2021
Resolved 20 May 2021
Resolution: Owner emailed pictures.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 3 May 2021
Resolved
Vessel's hot water heater was found with line/rope holding it in place. Provide hot water heater with a permanent mounting bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2021
Resolved 10 June 2021
Resolution: Vessel Owner emailed picture of rectified def.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 3 May 2021
Resolved
Fabricate & install guard for exposed rotating machinery on STBD Main Diesel engine Serpentine belt. PORT main engine had guard installed, STBD was missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2021
Resolved 20 May 2021
Resolution: Owner emailed pictures.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 3 May 2021
Resolved
Fire pump pressure guage was found inoperable. Replace broken PSI gauge for Fire Main, prove proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2021
Resolved 20 May 2021
Resolution: Owner emailed pictures.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 3 May 2021
Resolved
STBD generator exhaust was found supported by 2x4 timber, properly secure STBD generator muffler.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2021
Resolved 20 May 2021
Resolution: Owner emailed picture.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 December 2020
Resolved
Complete hull exam and ISE prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2021
Resolution: Vessel completed Hull inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 June 2020
Resolved
Provide vessel with valid alcohol test kits.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2020
Resolved 9 July 2020
Resolution: Received photo's of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 June 2020
Resolved
Repair fuel leak from manifold piping to aft port fuel tank.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2020
Resolved 9 July 2020
Resolution: Received photo's of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 June 2020
Resolved
Provide belt cover/guard for stbd generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2020
Resolved 9 July 2020
Resolution: Received photo's of corrected deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 June 2020
Resolved
Provide 02 ring buoys with SOLAS retro tape.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2020
Resolved 9 July 2020
Resolution: Received photo's of corrected deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 June 2020
Resolved
Provide 03 life jackets with SOLAS retro tape.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2020
Resolved 9 July 2020
Resolution: Received photo's of corrected deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 June 2020
Resolved
Provide fire stations with spanner wrenches.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2020
Resolved 9 July 2020
Resolution: Received photo's of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 June 2020
Resolved
Provide stbd main engine with additional hose clamp on exhaust.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2020
Resolved 9 July 2020
Resolution: Received photo's of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 June 2020
Resolved
Make both aft fuel tanks vent lines gradual slope upward.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2020
Resolved 9 July 2020
Resolution: Received photo's of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 June 2020
Resolved
Properly secure forward fuel tank return lines to prevent vibration and piping abrasion.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2020
Resolved 9 July 2020
Resolution: Received photo's of corrected deficiency.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 10 February 2020
Resolved
Repair damaged section around forward mooring cleat on port side of vessel
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2020
Resolved 21 February 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 10 February 2020
Resolved
Repair rotted sections of shear clamp and upper transverse frames on port side of engine space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2020
Resolved 14 February 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 10 February 2020
Resolved
Repair rotted sections of shear clamp and upper transverse frames on starboard side of engine space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2020
Resolved 10 April 2020
Resolution: Completed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 10 February 2020
Resolved
Repair rotted sections around line shaft penetrations of bottom aft transverse block frame in engine space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2020
Resolved 14 February 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 10 February 2020
Resolved
Repair rotted sections on upper and bottom transverse block frames adjacent to the transom
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2020
Resolved 14 February 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 10 February 2020
Resolved
Repair rotted section on #4 transverse block frame, starboard side under fuel tank
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2020
Resolved 12 February 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2019
Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, and over current protection.
Action required: 705 - Other - as specified
Due 8 January 2020
Resolved 31 January 2020
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 October 2019
Resolved
Vessel required to have the appropriate number of independent modular smoke detection and alarm units in accommodation spaces that are in compliance with UL 217. Must install unit in close proximity to the galley to satisfaction of Coast Guard Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2019
Resolved 18 October 2019
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 4 June 2019
Resolved
Install STBD generator pulley Guard
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 June 2019
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 4 June 2019
Resolved
Update radiotelephoney certificat to include the HF radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 26 September 2018
Resolved
CLSN: Vsl is broadcasting Invalid Call Sign,
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 14 July 2020
Resolution: Vessel not in VIVS.
Stability › Watertight Integrity › General
Issued 22 May 2018
Resolved
Prove stbd rudder post leak free
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 May 2018
Fire Fighting › Fire Pumps › Pressure
Issued 14 June 2017
Resolved
Demontrate proper operation of the fire pump gauge
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 July 2017
Resolved 14 July 2017
Resolution: Demontrated proper operation of the fire pump gauge
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 14 June 2017
Resolved
Provide proof of enrollment for new hire/all empolyees
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 July 2017
Resolved 14 July 2017
Resolution: Provided proof of enrollment for new hire/all empolyees
Engineering › Engine Controls (Electric/Electronic) › Actuator
Issued 29 July 2016
Resolved
Provide electrical instalation drawings / plans of electronic control system for recently installed Glendinning system to CG Marine Safety Center.
Condition: Improper/Lack of Maintenance
Due 29 December 2016
Resolved 25 July 2017
Resolution: Plans were submitted
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 13 May 2016
Resolved
Provide third party evaluation of the CO2 system in the engine room.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2016
Resolved 9 June 2016
Resolution: Received proof of proper installation and operation from Sergio of Global Fire Safety.
Operations/Management › Drills/Instruction › Not Conducted
Issued 13 May 2016
Resolved
Provide follow-on inspection for drills.
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 20 June 2016
Resolution: Got the vessel underway and condcuted MOB and Fire drills.
Construction/Loadline › Hull › Hull Plating
Issued 29 March 2016
Resolved
ISSUED WORKLIST FOR DRY DOCK ITEMS MENTIONED IN NARRATIVE
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 30 March 2016
Resolution: WORK LIST ITEMES RESOLVED