Records from 2008 to 2026. Most recent: inspection, 29 April 2026.
Inspection history · 26
29 April 2026
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8358037
29 January 2026
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8303634
18 March 2025
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8095854
26 November 2024
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8040157
4 October 2024
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8014635
13 March 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7879365
24 January 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7853879
3 October 2023
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7859328
12 April 2023
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7667547
12 April 2023
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7675385
9 May 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7445382
24 February 2022
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7401213
26 January 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7386244
3 May 2021
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7188420
28 May 2020
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6962458
7 May 2020
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6949880
24 January 2020
Drydock Extension · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6890818
10 January 2020
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6886697
25 September 2019
Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6821111
29 April 2019
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6672537
24 April 2018
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6398818
8 January 2018
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6334029
19 April 2017
Plan Review "T" Boat · Simplified Stability Test · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6128215
23 January 2017
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6075697
18 April 2016
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5856593
26 February 2016
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5822546
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 March 2024
Resolved
Operation of transmitters of any ship station must be performed by a person holding a commercial radio operator license or permit. Vessel operator did not have a radio operator permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 April 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 March 2024
Resolved
Every vessel subject to the communications act must have a detailed inspection of the radio installation by an FCC licenses technician in accordance with 47CFR80.59 A vessel must carry a first aid kit approved under approval series 160.041.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 April 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 March 2024
Resolved
Vessels first aid kit did not have ammonia inhalants as required by 46CFR160.041.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 April 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 April 2023
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable 30x30 flame screens made of corrosion resistant wire. 3 of the 4 fuel tank vents flame screens were no longer affixed to the discharge end of the fuel piping.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 April 2023
Resolved
Bilge alarm panel must indicate which bilge pump is operating.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 April 2023
Resolved
All unused wires should be removed or if they are in use, they should be properly terminated.
Several wires were not properly terminated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2023
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 12 April 2023
Resolved
All employees in a safety sensitive position must be enrolled in a drug and alcohol program. Provide proof that deck hand discussed at inspection is enrolled in a drug and alcohol program.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 April 2023
Resolved
As of December 27, 2022 Vessels on a coast-wise or Oceans route must have integrated fire detection installed in accordance with 46 CFR 181.450.
Vessels current fire detection system was not in compliance with 46 CFR 181.450.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2023
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 April 2023
Resolved
ll passenger vessels that have overnight accommodations for passengers must comply with the requirements in 46 CFR 177.500; construction/arrangement and means of escape. Your vessel must make the following corrections to meet the regulations:
1.) Need secondary egress from salon space on main deck that meets 46 CFR 177.500.
You must submit plans for approval to the U.S. Coast Guard Officer in Charge of Marine Inspection (OCMI) at the below email addressing all the listed items. Please allow a minimum of thirty (30) days for plan approval prior to making any alterations to your vessel. All vessels are required to comply with the emergency egress requirements by 27 December 2023.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 January 2026
Resolution: Vessel is approved for IFR
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 May 2021
Resolved
Repair broken junction box in way of ladder in engine room on stbd side.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2021
Resolved 13 May 2021
Resolution: Inspected by attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 May 2021
Resolved
Place properly terminated dead-end wires in steering gear compartment at forward bulkhead on port side in a junction box.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2021
Resolved 13 May 2021
Resolution: Inspected by attending MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 May 2021
Resolved
Vessel failed to complete annual inspection as of 03MAY2021. Vessel is restricted from carrying passengers until completion of annual inspection.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 May 2021
Resolution: Inspection done.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 3 May 2021
Resolved
Make electrical cable penetrations through engine room bulkheads vapor and watertight. 02 on forward bulkhead low near center line on stbd side. 02 on aft bulkhead high on port side.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2021
Resolved 13 May 2021
Resolution: Inspected by attending MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 May 2020
Resolved
Annual inspection not conducted within 3 months before or after anniversary date.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2020
Resolution: Annual Inspection Completed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 January 2020
Resolved
Vessels are to undergo a drydock examination and internal structural examination at least once every two years. The vessel's last drydock and internal structural examination took place on 08Jan2018. Vessel is restricted from passenger operations until satisfactory completion of the required drydock and internal structural examination.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 January 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2019
Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Due 25 December 2019
Resolved 28 May 2020
Resolution: Final 1-line diagram verified and stamped by MI.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 25 September 2019
Resolved
Complete but simple instructions for the operation of the fixed gas fire-extinguishing system must be located in a conspicuous place at or near each pull box and stop valve and in the space where the cylinders are stored.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2019
Resolved 11 October 2019
Resolution: Picture received.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2019
Resolved
Electrical equipment must be installed and maintained to protect passengers, crew and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment and electrical shock. Correct the following: (1) Secure distribution panel cover under seat in salon, (2)Properly replace household wire found in fwd storage area with marine grade boat cable. (3) Replace missing outlet cover in galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2019
Resolved 24 January 2020
Resolution: Observed by attending MI.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 September 2019
Resolved
Adequate emergency lighting automatically actuated upon failure of the main lighting system shall be fitted along the escape in vessels having passenger accommodations below the main deck. Install emergency lighting at forward emergency escape from passenger accommodation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2019
Resolved 30 January 2020
Resolution: Emergency lighting tested properly.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 September 2019
Resolved
Provide additional ladder rungs above main deck on forward emergency escape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2019
Resolved 24 January 2020
Resolution: Observed by attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 25 September 2019
Resolved
Suitable covers, guards or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Replace missing guard on exhaust fan in passenger accommodation space. Clean lint from all fans.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2019
Resolved 24 January 2020
Resolution: Observed by attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 April 2019
Resolved
Provide 03 identified life jackets with new retro-reflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2019
Resolved 31 May 2019
Resolution: Life jackets were removed from the vessel and no longer required due to reduced passenger count.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 29 April 2019
Resolved
Provide lazarette hatch with operable retaining device.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2019
Resolved 31 May 2019
Resolution: Laz hatch was provided with retaining line.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2019
Resolved
Repair main engine exhaust aft support bracket on both main engines.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2019
Resolved 31 May 2019
Resolution: Vessel rep removed support bracket, as it was designed for the engines old exhaust system.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 April 2019
Resolved
Repair inoperable life-float light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2019
Resolved 31 May 2019
Resolution: Life floats were removed from the vessel and replaced with life rafts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2019
Resolved
Repair exhaust leak in lazarette.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2019
Resolved 31 May 2019
Resolution: Exhaust leak was repaired.
Lifesaving › Lifefloat › Netting
Issued 24 April 2018
Resolved
Provide life lifloats for 33 persons IAW vessel's COI and route. 3 of 4 11 person life flats have wasted netting.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018
Resolved 9 May 2018
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 24 April 2018
Resolved
Demonstrate proper operation of the SSB radio.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018
Resolved 9 May 2018
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 24 April 2018
Resolved
Provide lock and maintain MSD OVBD valve closed with 3 miles of shore.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018
Resolved 9 May 2018
Resolution: MSD OVBD valve was directed by the attending MI to be closed on the spot.
Engineering › Sea-water System (primary cooling) › Piping
Issued 24 April 2018
Resolved
Provide a check valve and strainer to the open R/W piping to the stbd MDE.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018
Resolved 9 May 2018
Engineering › Fuel Oil Service System › Valve, Control
Issued 24 April 2018
Resolved
Lable emergency F/O shut off valves.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018
Resolved 9 May 2018
Fire Fighting › Means of Escape › Blocked
Issued 24 April 2018
Resolved
Move trash can blocking emergency escape from berthing area.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2018
Resolved 9 May 2018
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 23 January 2017
Resolved
Prove shutdown of ventilation when Pre Engineered system activates
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2017
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 23 January 2017
Resolved
Prove proper operation of SSB prior to operating greater than 100nm from shore
Action required: 705 - Other - as specified
Resolved 31 May 2017
Navigation › Piloting/Steering › Coast Guard Light List
Issued 23 January 2017
Resolved
Provide Light List
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 31 May 2017
Electrical › Electric Generation Source (service) › Panelboard
Issued 23 January 2017
Resolved
Provide voltmeter ammeter for generator
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 31 May 2017