← All vessels
VOYAGER
Passenger (Inspected) · Passenger Ship class · Built 1960s · USCG Southwest District (CGD-SW) · Other hulls named VOYAGER
VOYAGER is a 1963 passenger vessel (inspected). The Coast Guard has recorded 88 inspections since 1984, most recently in April 2026, along with 155 deficiencies, 1 operational control, 1 with no removal date recorded and 2 casualty investigations between 2008 and 2013.
Records from 1984 to 2026. Most recent: inspection, 29 April 2026.
- Built
- 1963
- Last inspected
- 29 April 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 155 recorded · 0 without a recorded resolution
- Controls
- 1 with no removal date recorded
- Casualties
- 2 investigations · 2008–2013
Identity
291511
WDF8052
44473
Flag
UNITED STATES
367490880
Maury page id
psix-44473
Inspections, by type
…with no type recorded9
Years with a record
39 calendar years (1984–2026)
The 88 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)48.7 ft × 15.3 ft × 5.3 ft
Registered tonnagegross 33 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDRAKE CRAFT BOAT CO · WILMINGTON, CA, UNITED STATES · built 1963
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it33 - Regulatory (Subpart C or D), Gross Ton
22 - Regulatory (Subpart C or D), Net Ton
22 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDF8052MMSI 367490880 · active · compulsorily equipped · granted 14 May 2021, expires 17 May 2031
WCG6145MMSI 366802420 · expired · compulsorily equipped · granted 21 April 2004, cancelled 19 July 2014
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 88
29 April 2026
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8358037
29 January 2026
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8303634
18 March 2025
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8095854
26 November 2024
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8040157
4 October 2024
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8014635
13 March 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7879365
24 January 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7853879
3 October 2023
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7859328
12 April 2023
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7667547
12 April 2023
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7675385
9 May 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7445382
24 February 2022
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7401213
26 January 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7386244
3 May 2021
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7188420
28 May 2020
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6962458
7 May 2020
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6949880
24 January 2020
Drydock Extension · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6890818
10 January 2020
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6886697
25 September 2019
Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6821111
29 April 2019
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6672537
24 April 2018
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6398818
8 January 2018
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6334029
19 April 2017
Plan Review "T" Boat · Simplified Stability Test · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6128215
23 January 2017
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6075697
18 April 2016
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5856593
26 February 2016
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5822546
17 August 2014
Type not recorded
No type recorded · USCGC EDISTO (WPB 1313) · USCG Southwest District (CGD-SW) · Activity 4969847
9 May 2014
Annual Inspection · Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4854566
19 January 2012
COI Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4227999
22 February 2010
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3673721
22 April 2009
DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3412853
7 September 2008
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3320185
6 September 2008
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3320327
6 June 2008
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3228931
26 May 2008
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3217913
8 April 2008
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3161732
1 April 2008
Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3159481
21 February 2007
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2869903
15 March 2006
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2591326
8 March 2005
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2290825
8 April 2004
Hull Examination · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2040159
24 March 2004
Deficiency Check · Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2023282
13 March 2003
Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1756548
5 April 2002
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1600623
22 February 2002
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1488508
30 November 2001
Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1417418
6 March 2001
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1384693
1 February 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1459664
3 September 2000
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 93270
14 March 2000
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1448076
9 December 1999
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1393289
9 March 1999
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1408310
15 January 1999
Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 811490
9 December 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 809237
26 March 1998
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1442685
12 February 1998
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1381205
14 September 1997
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 82776
10 May 1997
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 60330
31 March 1997
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1425883
29 November 1996
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1388174
12 March 1996
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1452152
21 March 1995
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1427027
29 November 1994
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1370958
16 March 1994
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1385208
4 May 1993
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1354335
16 March 1993
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1429729
21 May 1992
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1445933
17 December 1991
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1397796
28 March 1991
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1217687
19 March 1991
Re-Inspection · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 903617
4 June 1990
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1246145
16 May 1990
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1229490
15 March 1990
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 932010
12 May 1989
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1194092
17 April 1989
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1353005
30 March 1989
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1201516
23 March 1989
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1343088
28 April 1988
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1039032
11 April 1988
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1038793
29 March 1988
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 996278
28 April 1987
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1322707
20 April 1987
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1011576
30 March 1987
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1327025
29 August 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1003384
23 April 1986
Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1308772
10 April 1986
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 999546
7 February 1986
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1293838
1 November 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 977069
Deficiency record · 155
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 March 2024
Resolved
Operation of transmitters of any ship station must be performed by a person holding a commercial radio operator license or permit. Vessel operator did not have a radio operator permit.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 March 2024
Resolved
Every vessel subject to the communications act must have a detailed inspection of the radio installation by an FCC licenses technician in accordance with 47CFR80.59 A vessel must carry a first aid kit approved under approval series 160.041.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 March 2024
Resolved
Vessels first aid kit did not have ammonia inhalants as required by 46CFR160.041.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 April 2023
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable 30x30 flame screens made of corrosion resistant wire. 3 of the 4 fuel tank vents flame screens were no longer affixed to the discharge end of the fuel piping.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 April 2023
Resolved
Bilge alarm panel must indicate which bilge pump is operating.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 April 2023
Resolved
All unused wires should be removed or if they are in use, they should be properly terminated.
Several wires were not properly terminated.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 12 April 2023
Resolved
All employees in a safety sensitive position must be enrolled in a drug and alcohol program. Provide proof that deck hand discussed at inspection is enrolled in a drug and alcohol program.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 April 2023
Resolved
As of December 27, 2022 Vessels on a coast-wise or Oceans route must have integrated fire detection installed in accordance with 46 CFR 181.450.
Vessels current fire detection system was not in compliance with 46 CFR 181.450.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 April 2023
Resolved
ll passenger vessels that have overnight accommodations for passengers must comply with the requirements in 46 CFR 177.500; construction/arrangement and means of escape. Your vessel must make the following corrections to meet the regulations:
1.) Need secondary egress from salon space on main deck that meets 46 CFR 177.500.
You must submit plans for approval to the U.S. Coast Guard Officer in Charge of Marine Inspection (OCMI) at the below email addressing all the listed items. Please allow a minimum of thirty (30) days for plan approval prior to making any alterations to your vessel. All vessels are required to comply with the emergency egress requirements by 27 December 2023.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 May 2021
Resolved
Repair broken junction box in way of ladder in engine room on stbd side.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 May 2021
Resolved
Place properly terminated dead-end wires in steering gear compartment at forward bulkhead on port side in a junction box.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 May 2021
Resolved
Vessel failed to complete annual inspection as of 03MAY2021. Vessel is restricted from carrying passengers until completion of annual inspection.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 3 May 2021
Resolved
Make electrical cable penetrations through engine room bulkheads vapor and watertight. 02 on forward bulkhead low near center line on stbd side. 02 on aft bulkhead high on port side.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 May 2020
Resolved
Annual inspection not conducted within 3 months before or after anniversary date.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 January 2020
Resolved
Vessels are to undergo a drydock examination and internal structural examination at least once every two years. The vessel's last drydock and internal structural examination took place on 08Jan2018. Vessel is restricted from passenger operations until satisfactory completion of the required drydock and internal structural examination.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2019
Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 25 September 2019
Resolved
Complete but simple instructions for the operation of the fixed gas fire-extinguishing system must be located in a conspicuous place at or near each pull box and stop valve and in the space where the cylinders are stored.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2019
Resolved
Electrical equipment must be installed and maintained to protect passengers, crew and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment and electrical shock. Correct the following: (1) Secure distribution panel cover under seat in salon, (2)Properly replace household wire found in fwd storage area with marine grade boat cable. (3) Replace missing outlet cover in galley.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 September 2019
Resolved
Adequate emergency lighting automatically actuated upon failure of the main lighting system shall be fitted along the escape in vessels having passenger accommodations below the main deck. Install emergency lighting at forward emergency escape from passenger accommodation.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 September 2019
Resolved
Provide additional ladder rungs above main deck on forward emergency escape.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 25 September 2019
Resolved
Suitable covers, guards or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Replace missing guard on exhaust fan in passenger accommodation space. Clean lint from all fans.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 April 2019
Resolved
Provide 03 identified life jackets with new retro-reflective tape.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 29 April 2019
Resolved
Provide lazarette hatch with operable retaining device.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2019
Resolved
Repair main engine exhaust aft support bracket on both main engines.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 April 2019
Resolved
Repair inoperable life-float light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2019
Resolved
Repair exhaust leak in lazarette.
Lifesaving › Lifefloat › Netting
Issued 24 April 2018
Resolved
Provide life lifloats for 33 persons IAW vessel's COI and route. 3 of 4 11 person life flats have wasted netting.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 24 April 2018
Resolved
Demonstrate proper operation of the SSB radio.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 24 April 2018
Resolved
Provide lock and maintain MSD OVBD valve closed with 3 miles of shore.
Engineering › Sea-water System (primary cooling) › Piping
Issued 24 April 2018
Resolved
Provide a check valve and strainer to the open R/W piping to the stbd MDE.
Engineering › Fuel Oil Service System › Valve, Control
Issued 24 April 2018
Resolved
Lable emergency F/O shut off valves.
Fire Fighting › Means of Escape › Blocked
Issued 24 April 2018
Resolved
Move trash can blocking emergency escape from berthing area.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 23 January 2017
Resolved
Prove shutdown of ventilation when Pre Engineered system activates
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 23 January 2017
Resolved
Prove proper operation of SSB prior to operating greater than 100nm from shore
Navigation › Piloting/Steering › Coast Guard Light List
Issued 23 January 2017
Resolved
Provide Light List
Electrical › Electric Generation Source (service) › Panelboard
Issued 23 January 2017
Resolved
Provide voltmeter ammeter for generator
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 May 2014
Resolved
Complete annual inspection prior to carrying passengers, vessel not ready for inspection due to maintenance on board.
Communications › Radio Communications › EPIRB
Issued 22 February 2010
Resolved
Renew EPIRB battery and EPIRB Hydrostatic release.
Engineering › Fuel Oil Service System › Valve
Issued 22 February 2010
Resolved
Link at fuel shut off broke when cycled. Properly attach STBD AFT fuel tank valve emergency shut off.
Engineering › Fuel Oil Service System › Piping
Issued 22 February 2010
Resolved
Properly secure fuel piping at port fuel tank. Piping moves when emergency fuel shutoff is cycled.
Engineering › Steering Gear System › Hydraulic Hose
Issued 22 February 2010
Resolved
Repair hydraulic leak from steering ram at the three way connector.
Documentation › Certificates/Documents › FCC SSL
Issued 22 February 2010
Resolved
Provide FCC station license and FCC Safety Certificate.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 22 February 2010
Resolved
Provide DAPI program.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 22 February 2010
Resolved
Properly post COI, All pages visible for passengers.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 22 February 2010
Resolved
Provide Coast Pilot and light list updates.
Lifesaving › Hand Flares › Storage
Issued 22 February 2010
Resolved
Provide watertight container for hand flares and properly mark.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 February 2010
Resolved
Renew all expired first aid kit items
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 February 2010
Resolved
Properly attach lanyard with detachable clip to ring buoy light.
Communications › Radio Communications › EPIRB
Issued 22 February 2010
Resolved
Update emergency contact info for EPIRB. The last O/O is currently listed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 February 2010
Resolved
Properly install guard around pulley to bilge pump on port Main Diesel engine.
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 February 2010
Resolved
Repair E/R high water bilge audible alarm.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 8 April 2008
Resolved
Provide STCW certificate for crew.
Lifesaving › Lifeboat Equipment › Water/Water Receptacles
Issued 8 April 2008
Resolved
Provides three fire buckets.
Engineering › Steering Gear System › Hand Pump
Issued 8 April 2008
Resolved
Provide a manual hand pump
Lifesaving › Rescue Boat › Boarding Ladder
Issued 8 April 2008
Resolved
Restraint ladder to make it sturdier.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 8 April 2008
Resolved
Provide an instruction for lifejacket.
Lifesaving › Lifefloat › Netting
Issued 8 April 2008
Resolved
Repair inside line and corner strap for the rear top lifefloat.
Communications › Radio Communications › EPIRB
Issued 8 April 2008
Resolved
Provide a hydro release for the EPIRB.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 1 April 2008
Resolved
Repair/install metallic bulkhead connections on laz fwd bhd. Non-metallic hoses are not allowed to penetrate bhd. Must have metallic bhd fittings when hose is used.
Engineering › Steering Gear System › Linkage
Issued 1 April 2008
Resolved
Double nut or install cotter pin on port rudder/steering rod connection.
Engineering › Sea-water System (primary cooling) › Piping
Issued 1 April 2008
Resolved
Ensure all hoses are double hose clamped in E/R where possible/feasible.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 1 April 2008
Resolved
Install flame screens on Stbd fwd fuel tank vent. Ensure screen is at least 30x30 mesh.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 1 April 2008
Resolved
Re-install Fireboy remote pull cable. Correct prior to taking passengers.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 1 April 2008
Resolved
No MSD onboard. Provide written proposal addressing the installation of MSD holding tank for installed toilet. Ensure proposal addresses normal use/capacity for operations w/in 3 miles of shore and the installation of thru hull valve and venting of tank. Ensure head door is locked when vsl is w/in 3 miles of shore until corrected.
Construction/Loadline › Hull › Bottom Plating
Issued 1 April 2008
Resolved
Make vsl available for inspection once back in the water for credit hull inspection.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 11 April 2007
Resolved
Prove current fixed fire system for E/R is correct for that sized space, or install correct system.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 11 April 2007
Resolved
Vessel does not have NAVTEX installed. Vsl restricted to not more than 100 NM from mainland shore until corrected. COI will be ammended to reflect 100 NM from mainland shore route if owner elects not to install.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 28 February 2007
Resolved
Make aft E/R bulkhead watertight.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 21 February 2007
Resolved
Repair/replace (1) waterlight for lifefloat.
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 21 February 2007
Resolved
Replace retro-reflective tape on lifefloats and PFD's as necessary.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 February 2007
Resolved
Replace line for ringbuoy.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 21 February 2007
Resolved
Provide current and original Certificate of Documentation onboard the vessel.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 21 February 2007
Resolved
Provide alcohol test kits.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 21 February 2007
Resolved
Provide (1) additional child PFD.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 21 February 2007
Resolved
Install emergency lighting in accommodation space.
Engineering › Sea-water System (primary cooling) › Piping
Issued 21 February 2007
Resolved
Double hose clamp raw water cooling hoses for both M/E's.
Engineering › Steering Gear System › Pin
Issued 21 February 2007
Resolved
Provide cotter pin or double nut on steering linkage.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 21 February 2007
Resolved
Obtain FCC Marine Radio Operators permit or higher license.
Navigation › Piloting/Steering › US Coast Pilot
Issued 21 February 2007
Resolved
Provide currently corrected Coast Pilot [name withheld], and tidal current tables.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 February 2007
Resolved
Remove or properly wire portable bilge pump in laz.
Fire Fighting › Grease Extraction Hood › General
Issued 21 February 2007
Resolved
Clean grease buildup and install galley grease extraction hood to meet 181.425 and CID Policy Letter #20.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 21 February 2007
Resolved
Ensure emergency fuel shut off valves for (2) fuel tanks in laz are manually operable from outside of the space.
Navigation › Piloting/Steering › Marine Charts
Issued 15 March 2006
Resolved
Replace/purchase new (current) navigational chart of the area/s transited.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 15 March 2006
Resolved
Replace/purchase 2006 edition of the Coast Guard List publication. Current edition is outdated.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 15 March 2006
Resolved
No Tidal Current Table publication o/b. Purchase 2006 edition of the Tidal Current Tables as required.
Navigation › Piloting/Steering › US Coast Pilot
Issued 15 March 2006
Resolved
Replace/purchase 2006 edition of the U.S. Coast Pilot publication. Current edition is outdated.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 15 March 2006
Resolved
Repair/replace faulty electrical shortage on the bilge alarm panel. Troubleshoot the cause and make operational for retest.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 March 2005
Resolved
Replace expired items in First aid kit.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 8 March 2005
Resolved
Procure cover for junction box in engine room.
Fire Fighting › Remote Fuel Shutoff › General
Issued 8 March 2005
Resolved
Label fuel shut off valves.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 March 2005
Resolved
Procure light cover for light in galley.
Stability › Watertight Integrity › General
Issued 8 March 2005
Resolved
Plug and seal bulkhead penetrations above wire run in engine room.
Lifesaving › Lifejacket/PFD (Type IV) › Condition
Issued 8 March 2005
Resolved
Replace life ring.
Communications › Radio Communications
Issued 24 March 2004
Resolved
Provide operable EPIRB. EPIRB self activated and owner was unable to turn unit off. Unit is in the repair facility. Owner will provide operable EPIRB during April 04 dry dock exam
LEGACY COMPONENT DESC: EPIRB
Lifesaving › Lifejacket/PFD (General)
Issued 13 March 2003
Resolved
Ensure all retro tape on PFD's is adequate IAW 46 CFR 185.604. LEGACY COMPONENT DESC: Retroreflective Material
Lifesaving › Lifejacket/PFD (General)
Issued 13 March 2003
Resolved
Install physical separator for child and adult PFD's IAW 46 CFR 180.78. LEGACY COMPONENT DESC: Storage
Accommodation/Occupational Safety › Medical/First Aid
Issued 13 March 2003
Resolved
Replace expired/missing first aid kit items IAW 46 CFR 184.710. LEGACY COMPONENT DESC: Medicine Chest
Stability › Watertight Integrity
Issued 13 March 2003
Resolved
Seal exhaust pipe penetrations in engineroom IAW 46 CFR 176.802, 179.310, and 179.320.
Construction/Loadline › Penetrations
Issued 5 April 2002
Resolved
Clean/lubricate all thru hull fittings & show proper operation prior to installation. LEGACY COMPONENT DESC: Pipe Flange
Engineering › Shafting/Propeller Arrangements
Issued 5 April 2002
Resolved
Replace starboard aft cutlass bearing. LEGACY COMPONENT DESC: Bearing
Construction/Loadline › Penetrations
Issued 5 April 2002
Resolved
Clean MSD valve/pipe connection & remove all excess waste material from within pipe. LEGACY COMPONENT DESC: Pipe Flange
Electrical › Electric Supply System (service)
Issued 22 February 2002
Resolved
Terminate wires to blowers in laz. in a junction box. LEGACY COMPONENT DESC: Cable
Lifesaving › Lifejacket/PFD (Type I)
Issued 22 February 2002
Resolved
Provide three adult type one PFD's. LEGACY COMPONENT DESC: Condition
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 22 February 2002
Resolved
Provide proof of operable fixed system for engine room. System was accidentally discharged by service company on day of COI inspection. LEGACY COMPONENT DESC: Quantity of CO2
Engineering › Fuel Oil Service System
Issued 22 February 2002
Resolved
Secure fuel oil manifold to deck. LEGACY COMPONENT DESC: Piping
Engineering › Diesel Engine (propulsion-direct drive)
Issued 22 February 2002
Resolved
Replace hose on exhaust for starb. MDE. LEGACY COMPONENT DESC: Piping (exhaust)
Accommodation/Occupational Safety › Medical/First Aid
Issued 22 February 2002
Resolved
Replace expired items in first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Operations/Management › FireFighting
Issued 22 February 2002
Resolved
Replace inoperable smoke detector in berthing space. LEGACY COMPONENT DESC: Patrol System (Special Category Spaces)
Engineering › Bilge Water Management System
Issued 22 February 2002
Resolved
Install skin valve on forward bilge pump overboard discharge line. LEGACY COMPONENT DESC: Valve
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 22 February 2002
Resolved
Install insulation on ship service generator exhaust piping. LEGACY COMPONENT DESC: Piping (exhaust)
Deck/Cargo › Mooring/Anchoring
Issued 22 February 2002
Resolved
Tie down spare anchor in laz. LEGACY COMPONENT DESC: Anchor Chain (general)
Construction/Loadline
Issued 30 November 2001
Resolved
Repair wood rot/damaged zinc plating through hull bolts on transom port side during next hull inspection on or prior to 09APR02.
Fire Fighting
Issued 9 March 1999
Resolved
Install stainless steel protective covering around galley grill to prevent spred of fire.
Construction/Loadline
Issued 9 March 1999
Resolved
Install high level bilge alarm in fwd compartment as per 46CFR182.530.
Fire Fighting
Issued 9 March 1999
Resolved
Install smoke dector in overnight accommodation space as per 46 CFR 181.410.
Lifesaving
Issued 12 March 1996
Resolved
Provide on board 2 additional adult and 1 children's life preservers. Vessel is restricted to carrying not more than 44 adults until life preservers are placed on board.
Documentation
Issued 12 March 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving
Issued 21 May 1992
Resolved
Provide vessel with 10 additional adult P.F.D.'s. Vessel may only carry thirty-six (36) total persons on limited coastwise route.
Lifesaving
Issued 19 March 1991
Resolved
RENEW TWO LIFE FLOAT PADDLES AND PROPERLY TIE OFF ONE END OF EACH OF TWO CARBIDE WATER LIGHTS TO THE VESSEL SO AS TO ACTIVATE IF THEY FLOAT FREE.
Documentation
Issued 19 March 1991
Resolved
MARK PROPER OFFICIAL NUMBER ON MAIN BEAM.
Fire Fighting
Issued 19 March 1991
Resolved
RECHARGE 3 B-II FIRE EXTINGUISHERS AND SERVICE ALL EXTINGUISHERS ABOARD PRIOR TO OPERATION OF VESSEL.
Construction/Loadline
Issued 19 March 1991
Resolved
CAULK AND MAKE WATERTIGHT AND FUME TIGHT FORWARD ENGINE COMPARTMENT BULKHEAD PRIOR TO CARRIAGE OF PASSENGERS.
Engineering
Issued 19 March 1991
Resolved
REPLACE FLEXIBLE HOSES AT: PORT AND STBD MAIN ENGINE RAW WATER INTAKE_x001C_ GENERATOR RAW WATER INTAKE_x001C_ GENERATOR WATER RECIRCULATING HOSE._x001C_ DOUBLE HOSE CLAMP ALL OF THE ABOVE.
Documentation
Issued 19 March 1991
Resolved
PROVIDE VALID FCC STATION LICENSE.
Engineering
Issued 19 March 1991
Resolved
REPAIR STBD AFT FUEL TANK EMERGENCY FUEL SHUT OFF.
Lifesaving
Issued 19 March 1991
Resolved
REPLACE BATTERIES IN ALL LIFE JACKET LIGHTS AND TWO ELECTRIC WATERLIGHTS.
Lifesaving
Issued 19 March 1991
Resolved
REPAIR OR REPLACE ONE CHILD LIFE JACKET PRIOR TO CARRIAGE OF OVER 40 PEOPLE
Electrical
Issued 16 May 1990
Resolved
RENEW TWO FRACTURED GENERATOR SUPPORT CROSSBEAMS.
Accommodation/Occupational Safety
Issued 15 March 1990
Resolved
PROVIDE EMERGENCY ESCAPES FOR PASSENGER BERTHING.
Lifesaving
Issued 15 March 1990
Resolved
PROVIDE 15 ADULT AND 1 CHILDREN'S PFD'S. VESSEL IS PERMITTED TO CARRY A TOTAL OF 31 PERSONS ON BOARD UNTIL REQUIREMENT IS SATISFIED.
Electrical
Issued 15 March 1990
Resolved
PROPERLY SUPPORT ELECTRICAL WIRING THROUGHOUT VESSEL IN ACCORDANCE WITH IEEE-45.
Electrical
Issued 15 March 1990
Resolved
PROPERLY SUPPORT WIRING AS IT ENTERS ALL CIRCUIT BREAKER BOXES (USING STUFFING BOXES).
Deck/Cargo
Issued 15 March 1990
Resolved
USE USCG APPROVED, FIRE-RETARDANT, FLEXIBLE HOSE FOR ALL FUEL TANK VENTS.
Engineering
Issued 15 March 1990
Resolved
PROPERLY BOND ALL FUEL TANK FILLS.
Accommodation/Occupational Safety
Issued 15 March 1990
Resolved
PROVIDE EMERGENCY LIGHTING FOR PASSENGER BERTHING, IAW 46 CFR 184.30-5.
Engineering
Issued 23 March 1989
Resolved
RENEW BELLOW STYLE EXHAUST ON STARBOARD MAIN ENGINE, OUTBOARD.
Engineering
Issued 23 March 1989
Resolved
EXAMINE/REPAIR EPOXY ON FORWARD STARBOARD FUEL TANK ON AFT INBOARD CORNER.
Engineering
Issued 23 March 1989
Resolved
REPLACE WASTED FUEL LINE AND SUPPORT OTHERS IN WAY OF PORT SHAFT.
Engineering
Issued 23 March 1989
Resolved
MAKE AVAILABLE FOR EXAMINATION INBOARD, AFT CORNER OF PORT FORWARD FUEL OILTANK.
Engineering
Issued 23 March 1989
Resolved
REMOVE AND REPLACE RUBBER HOSE COUPLERS ON FUEL OIL REMOTE SHUTOFF REACH RODS.
Construction/Loadline
Issued 28 April 1988
Resolved
REPLACE ABOUT 6 FEET OF ROTTED SHEER CLAMP IN AREA OF PORT SIDE OF COLLISION BULKHEAD PRIOR TO CARRIAGE OF PASSENGERS.
Lifesaving
Issued 29 March 1988
Resolved
REPLACE OLD BATTERY FOR THE RING BUOY WATER LIGHT PRIOR TO NIGHT OPS.
Accommodation/Occupational Safety
Issued 29 March 1988
Resolved
LABEL HEAD TANK DISCHARGE WITH PLACARD WARNING
Lifesaving
Issued 29 March 1988
Resolved
REPLACE PFD LIGHT BATTERIES WITH DATED BATTERIES.
Lifesaving
Issued 29 March 1988
Resolved
PROVIDE 4 ADULT AND 1 CHILD PFD IN ADDITION TO THOSE STAMPED PRIOR TO CARRIAGE OF MORE THAN 40 TOTAL PERSONS.
Lifesaving
Issued 29 March 1988
Resolved
REPLACE 6 OUTDATED ORANGE SMOKE FLARES.
Lifesaving
Issued 29 March 1988
Resolved
REPLACE ONE MISSING PADDLE ON PORT LIFEFLOAT.
Lifesaving
Issued 29 March 1988
Resolved
REPAIR OR REPLACE ONE LIFE FLOAT WHERE STOVE IN.
Lifesaving
Issued 29 March 1988
Resolved
REPLACE ONE WATERLIGHT ON LOWER LIFE FLOAT PRIOR TO NIGHT OPS.
Deck/Cargo
Issued 7 February 1986
Resolved
SUPPLY COVER FOR ANCHOR CHAIN HOWSE PIPE
Engineering
Issued 7 February 1986
Resolved
LABLE ALL (6) EMERGENCY FUEL SHUTOFF'S
Electrical
Issued 7 February 1986
Resolved
FURNISH GUARD FOR GENERATOR FAN BELT
Electrical
Issued 7 February 1986
Resolved
SECURE MOUNTS TO GENERATOR.
Engineering
Issued 7 February 1986
Resolved
FURNISH INSULATION OF STBD MAIN ENGINE EXHAUST PIPE
Lifesaving
Issued 7 February 1986
Resolved
STENCIL LIFE PRESERVER STOWAGE
Casualty record · 2
6 September 2008Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3320327
18 September 2013Routine · role: Involved in a Marine Casualty · activity 4719578
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.