Inspection history · 73
12 June 2025
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8157907
13 October 2022
Deficiency Check · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7580285
12 August 2022
Damage Survey
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7535724
1 August 2022
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7523074
1 July 2022
Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7492575
12 June 2022
Deficiency Check · Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7474802
29 April 2022
Administrative Inspection · Periodic Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7442259
20 April 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7435464
4 April 2022
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7424628
25 March 2022
Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7420143
15 March 2022
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7412500
14 February 2022
Security Breach · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7397459
10 February 2022
In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7394967
5 February 2022
Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7391349
22 October 2021
Deficiency Check · Examination of Repairs · Drydock Exam · Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7337696
9 August 2021
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7281723
24 June 2021
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7241863
17 June 2021
Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7228636
14 May 2021
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7197232
26 April 2021
Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7182932
26 April 2021
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7902073
23 April 2021
Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7181609
14 April 2021
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7214032
11 April 2021
Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7172867
4 April 2021
In-Service Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7168309
4 April 2021
Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7168339
26 March 2021
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7163836
26 March 2021
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7164857
15 March 2021
Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7157381
16 October 2020
Drydock Exam · Deficiency Check · MARPOL Annex VI Survey · Examination of Repairs · MTSA/ISPS Verification · MARPOL Annex IV Survey · MARPOL Annex V Examination · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7078766
19 September 2020
Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7061715
15 September 2020
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7060856
10 September 2020
Damage Survey
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7055165
14 August 2020
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7033344
9 August 2020
Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7029253
30 July 2020
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7020099
30 July 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7021180
29 June 2020
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6991532
3 June 2020
Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6967134
1 April 2020
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 6940109
27 February 2020
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6917710
20 February 2020
Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6912443
5 February 2020
Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6921586
25 January 2020
Damage Survey · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6897413
23 January 2020
Damage Survey · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6900553
7 December 2019
Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6869090
5 December 2019
Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6867975
25 November 2019
Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6862554
17 May 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6686516
12 November 2017
Examination of Repairs · COI Inspection · Internal Structural Exam · Deficiency Check · Drydock Exam · Inclining Experiment
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6332656
5 November 2017
Load Line/Change of Employment
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6302035
24 October 2017
Periodic Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6297746
17 October 2017
Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6290462
12 September 2017
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6281215
12 June 2017
Periodic Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6175116
31 March 2017
Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6117162
3 March 2017
Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6099813
12 January 2017
Deficiency Check · COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6069882
19 December 2016
Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6060126
12 December 2016
Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6056582
13 October 2016
Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6024425
3 October 2016
Periodic Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6015628
9 August 2016
Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 5967258
4 August 2016
Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5963482
11 July 2016
Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 5937317
28 June 2016
Periodic Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 5924898
9 May 2016
Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 5872828
3 May 2016
Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 5868274
26 April 2016
Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 5864254
20 April 2016
Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 5858603
31 March 2016
Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5844461
22 February 2016
Hull Examination · MARPOL Annex VI Survey · MARPOL Annex I Examination · MTSA Verification · Internal Structural Exam · Deficiency Check · COI Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 5822867
14 February 2016
Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5816646
11 - Life Saving Appliances › N/A - No Subsystem › Fast Rescue Boats
Issued 17 August 2022
Resolved
Lifeboat and rescue boat release gear must be operationally tested under a load of 1.1 times the total mass of the lifeboat when fully loaded with its full complement of persons and equipment whenever overhauled. The vessel reported significant damage to the port side rescue boat wire. Immediate repairs shall be made to the lifeboat wire. A weight test shall then be conducted IAW 46 CFR 199.190 in the presence of a Marine Inspector prior to the vessel departing Ketchikan.
The port side rescue boat shall not be used other than in an emergency.
46 CFR 199.190(h)(5)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 19 August 2022
Resolution: Witness satisfactory weight test of new wire.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 August 2022
Resolved
Means of escape: Escape routes shall be maintained in a safe condition, clear of obstacles: As currently designed the emergency escape route, leading from the auxiliary machinery space via the enclosed vertical trunk ladder, is obstructed by a large rising stem salt water cooling supply valve. The valve handle and stem protrude into the center of the walkway at a height of Apx 1ft. This protrusion not only imposes a tripping hazard but also an impaling hazard to crewmembers.
Rectify hazard to the satisfaction of attending CG Marine inspector prior to next credit dry dock. SOLAS 14 II-2/13-1.2
Action required: 705 - Other - as specified
Resolved 1 November 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 July 2022
Resolved
Automatic propulsion systems, automated electric power management systems, and all associated subsystems and equipment must be capable of meeting load demands from standby to full system rated load, under steady state and maneuvering conditions, without need for manual adjustment or manipulation. The vessel reported the #3 SSDG shutdown and the ship lost power while moored in Ketchikan. Provide repair plan and prove proper operation to the satisfaction of the attending MI prior to completion of next scheduled drydock. Should additional similar failures occur, the Master must immediately notify the cognizant Officer in Charge of Marine Inspections.
46 CFR 62.35-1(b)
Action required: 705 - Other - as specified
Resolved 12 September 2022
Resolution: Witnessed operation of #3 SSDG paralleled on the bus.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 July 2022
Resolved
Repair reported issue of #2 SSDG generator excitation failure. Provide technician report and prove proper operation to the satisfaction of the attending Marine Inspector prior to completion of next scheduled dry-dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 June 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 June 2022
Resolved
#3 generator cooling water pump died, and left the #3 generator inoperable. Fix #3 generator cooling water pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 June 2022
Resolution: Found Loose keeper bolt on #3 Gen impeller. retorqued, ops check good.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 29 April 2022
Resolved
Each lifesaving appliance must be in working order and ready for immediate use. Make immediate repairs as necessary and in accordance with the Captain and [name withheld] report of both Lifeboats.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2022
Resolved 1 July 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 April 2022
Resolved
Automatic propulsion systems, automated electric power management systems, and all associated subsystems and equipment must be capable of meeting load demands from standby to full system rated load, under steady state and maneuvering conditions, without need for manual adjustment or manipulation. The STBD M/E would not meet bridge commands under combinator mode. Vessel shall operate the STBD M/E in full RPM mode during all restricted maneuvering operations. Should additional similar failures occur, the Master must immediately notify the cognizant Officer in Charge of Marine Inspections. Provide a tech report and demonstrate proper operation of the STBD M/E from the bridge to the satisfaction of the attending MI.
46 CFR 62.35-1(b)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 14 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 April 2022
Resolved
Automatic propulsion systems, automated electric power management systems, and all associated subsystems and equipment must be capable of meeting load demands from standby to full system rated load, under steady state and maneuvering conditions, without need for manual adjustment or manipulation. The STBD controllable pitch propeller failed and went full astern while maneuvering to the dock. Vessel shall ensure the standby electric hydraulic pump is on during all restricted maneuvering operations. The vessel shall also provide extra manning to monitor the CPP system while the vessel is in restricted maneuvering. Should additional similar failures occur, the Master must immediately notify the cognizant Officer in Charge of Marine Inspections.
46 CFR 62.35-1(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2022
Resolved 14 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 March 2022
Resolved
Machinery vital to the main propulsion system must be provided in duplicate unless the system served is provided in independent duplicate, or otherwise provides continued or restored propulsion capability in the event of a failure or malfunction of any single auxiliary component. The vessel reported the STBD M/E unable to maintain steady RPM and then shutting down during transit. Demonstrate proper operation of the STBD M/E.
46 CFR 58.01-35
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 March 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 February 2022
Resolved
A two-way communications means between the elevator car and a location staffed by authorized personnel shall be provided. Marine Inspector found the two-way communication in the passenger elevator is not operational. Repair communication system and provide local OCMI with mitigation strategy as to how equivalent level of safety will be achieved until system is repaired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2022
Resolved 15 March 2022
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 22 October 2021
Resolved
Identified wasted steel on the Officer’s Mess deck above passenger cabin. Provide gauging report of the deck and crop and renew to good steel in accordance with the UT results, and to the satisfaction of attending CG Marine Inspector. 46 CFR 72.01-15
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 October 2021
Resolved
Safety vavles on the waste heate boilers must be stamped in accordance with section I of ASME Boiler and Pressure Vessel Code and stamped with (V) not (UV). Replace safety valves In accordance with 46 CFR 52.01-120, prior to using the waste heat boilers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 20 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 March 2021
Resolved
Vessel's starboard controllable pitch propeller has a low pressure alarm on the manual pump. Prove proper operation of the controllable pitch propeller system to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2021
Resolved 17 March 2021
Resolution: Identified low pressure alarm's parameters were set too high causing alarm to function while still within normal operating pressure. Adjusted parameters, ops check good.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 16 October 2020
Resolved
Temporary lighting is required in passenger & crew quarters, other spaces in accordance with 46 CFR 112.15-1. Identified 83 temporary lighting not working in crew & passenger cabins. Provide 02 additional watchman IAW 46 CFR 78.30-15 (and flashlights for occupied cabins), to assist passengers/crew in an emergency, until the lights have been repaired. Demonstrate to attending CG Marine Inspector. 74 SOLA Amended II-1/41.6 & 46 CFR 112.15-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2021
Resolved 25 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 October 2020
Resolved
The test procedure (PSTP) for 9.6 Power Failure Alarms are not written properly re-write and demonstrate to attending CG Marine Inspector. (30 days)
Action required: 705 - Other - as specified
Due 18 March 2021
Resolved 14 April 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 October 2020
Resolved
A steam condensate system of adequate cooling capacity shall be installed to ensure that the installed waste heat boilers can be maintained within the parameters established by the manufacturer at all engine loads.
Action required: 705 - Other - as specified
Due 15 April 2021
Resolved 25 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 October 2020
Resolved
Provide Kongsberg technicians report after his inspection of the reduction gear system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2021
Resolved 5 March 2021
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 19 September 2020
Resolved
The main steering gear must be operable from the pilot house by mechanical, hydraulic, electrical, or other means . This gear and components must give full follow up control of the rudder. Currently the the STBD steering gear control system is not operating as designed and system is not correctly answering commands from pilot house. Vessel must correct problem and demonstrate proper operation of steering system to the satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 21 September 2020
Resolved 27 September 2020
Resolution: See attached service technician report.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 10 September 2020
Resolved
To assist in casualty investigations, ships, when engaged on international voyages, subject to the provisions of reg 1.4, shall be fitted with a Voyage Data Recorder (VDR). The VDR installed is not operating properly. Make permanent repairs and provide a technician report to MSD Ketchikan.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 October 2020
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 14 August 2020
Resolved
The vessels structure in the number 8 starboard ballast water tank is no longer in compliance with the ABS SVR. Vessel conducted weld repairs to two holes on the tank, one 1/2 inch, one 1/8 inch, where water was leaking when the tank was full. Temporary repairs in effect until next scheduled dry dock for month of October.
46 CFR 72.01-15/ABS SVR Part 3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2020
Resolved 5 January 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 August 2020
Resolved
Primary automatic control systems for propulsion is required to be stable over the entire range of normal operation, without the need for manual adjustment or manipulation. As reported by Master, Matanuska port propulsion control system disconnects randomly. 46 CFR 62.35-1(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 August 2020
Resolved 8 October 2020
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 29 June 2020
Resolved
On board electronic stability computers may be used as an adjunct to the required booklet, but the required booklet must contain all necessary information to allow for the evaluation of the stability of any intact condition that can be evaluated by use of the computer. The computer program was not updated appropriately after the last vessel incline. Update the program or use the T&S book and calculate everything by hand. 46 CFR 170.110 (f)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2020
Resolved 30 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 January 2020
Resolved
Provide the port reduction gear lubrication system for inspection to verify successfully, measures have been taken to eliminate oil/water emulsifcation caused by the heat exchange failure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 January 2020
Resolved 23 January 2020
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 December 2019
Resolved
06. The fire detection system is showing trouble in the galley stores dry sprinkler system (Supervisory L3-005 Low Pressure E126P). Make permanent repairs to the fire detection system and provided technician report. 46 CFR 76.05
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2020
Resolved 27 February 2020
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 7 December 2019
Resolved
Make permanent repairs to the Anchor Windlass VFD and provide technicians report.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2020
Resolved 27 February 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 December 2019
Resolved
The exhaust gas temperatures produced by the propulsion engines appear to be higher than the design temperatures indicated on drawings for this waste heat boiler installation. Provide documentation that the source of heat to your waste heat boilers does not exceed the maximum design temperature of the boiler components exposed to the exhaust gas. This temperature must be verified by testing or by the manufacturer of the engine or other equipment producing the exhaust gas. 46 CFR 52.25-20
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2020
Resolved 14 July 2020
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 November 2019
Resolved
Make temporary repair to the stbd side cafeteria exit door, muster station C (kick plate). In addition, replace the stbd side sprinkler zones door, the old video game room door and the cafeteria door at the next dry-docking of the vessel with approved doors.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 December 2020
Resolved 16 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 November 2019
Resolved
Make the Auxiliary boiler mountings ready for inspection in accordance with 46 CFR 61.05-10. Last date inspected was 19 June 2009 the interval permits 10 years, an inspection is required.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 December 2019
Resolved 2 December 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 November 2019
Resolved
Make the old video game room door weather-tight. If the door is considered an emergency escape in accordance with vessel plans make the door operable and accessible to passengers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 December 2019
Resolved 6 December 2019
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 25 November 2019
Resolved
The call back emergency comunication system is not operable at all stations. Repair the installed call back system as required by SOLAS 74 (2017 Amend.) III/6.4 and 46 CFR 113.30-3
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2020
Resolved 13 December 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 November 2019
Resolved
Vessel must provide an approved Periodic Safety Test Procedures (PSTP) for use on board the vessel. The final approval of the PSTP will be conducted by the Coast Guard's MSC upon the receipt of all verified test procedures, as submitted per the contract between Vigor Shipyard and Alaska Marine Highway System (AMHS).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2019
Resolved 20 February 2020
Resolution: Received MSC Letter E2-2000491, dated 18FEB20, approving the Periodic Safety Test Procedures for the vessel. Added an electronic copy of this letter to the Documents tab in MISLE.
Construction/Loadline › Hull › Bottom Plating
Issued 2 February 2018
Resolved
Submit repair proposal for items identified during hull walk including holes in the vicinity of the bottom plating around the rudders, pitting on rudders, localized pitting on port/starboard bottom shell plating as detailed in the call out sheet, bow thruster pitting, and gauging on the side shell plating on the boot top forward of the car deck doors both port and starboard.
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 23 October 2019
Resolution: All items during the hull walk were satisfactorily addressed during this dry-dock period.
Fire Fighting › Fire Main › Condition
Issued 11 January 2018
Resolved
Repair all soft patches as identified in the soft patch log (currently 15 items)
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 23 October 2019
Resolution: Vessel's fire main system was subjected to a hydrostatic test; all sat. All remaining soft patches from the vessel's soft patch log have been properly addressed to the satisfaction of the attending marine inspector.
Construction/Loadline › Structures › Deck Plating
Issued 11 January 2018
Resolved
Gauge metal thickness and crop and renew deck plating as required in way of the port side boat deck public female head.
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 23 October 2019
Resolution: Deck IWO the female bathroom on the boat desk was renewed with new plating.
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 24 October 2017
Resolved
Gauge the metal thickness in way of the #6 Fuel Oil STBD Wing tank near frame 85-86 below the MSD OVBD valve. Crop and renew as needed.
Due 31 May 2018
Resolved 7 November 2018
Resolution: Repairs complete
Engineering › Diesel Engine (propulsion-reduction gear) › Charge Air Cooling
Issued 17 October 2017
Resolved
Coolant hose failed causing engine to over heat.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 18 October 2017
Resolved 17 October 2017
Resolution: Chief Engineer replaced coolant line. Engine tested all sat.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 31 March 2017
Resolved
WATERTIGHT DOOR AUTOMATIC OPERATION INOPERABLE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 12 September 2017
Lifesaving › Lifeboat › Propulsion Starting System
Issued 3 March 2017
Resolved
Bad starter identified during weekly lifeboat run tests.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 9 March 2017
Resolution: Starter Repaired. All Sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Liner
Issued 12 December 2016
Resolved
Make permanent repairs to the STBD Main Engine prior to departure from Ketchikan, AK. Demonstrate operation of the engine to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2016
Resolved 13 December 2016
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 13 October 2016
Resolved
Fire door holdback system failed causing fire doors to remain closed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 October 2016
Resolved 13 October 2016
Resolution: Vessel crew identified a malfunctioning AC/DC rectifier causing the system to fail closed. Component was renewed with a spare carried aboard. System tested - all sat.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 3 October 2016
Resolved
Repair watertight Door #1,Electric opening on both sides ASTM F-1197 class III Controls are required to operate the door from all times other than passing through. Provide manufactures technical report, as to why this door keeps breaking. IAW 46 CFR 171
the bridge and both sides. Keep door closed at
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2016
Resolved 13 December 2016
Engineering › Steam System (auxiliary) › Lagging/Insulation
Issued 9 August 2016
Resolved
Make repairs to the Auxiliary boiler in accordance with manufacturers recommendations. at next overhaul period. To the satisfaction attending CG Marine Inspector Or ABS surveyor.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 10 February 2017
Accommodation/Occupational Safety › Ventilation › General
Issued 9 August 2016
Resolved
Auxiliary boiler may be run, as long as air quality is monitored in the Auxiliary room once per watch and logged. NIOSH,limit 35 PPM an 8 HR TWA, and 200 PPM ceiling. If exceeded than secure boiler and provide temporary services until repaired.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 10 February 2017
Lifesaving › Launching Appliances › Winch
Issued 4 August 2016
Resolved
Replace davit control box variable frequency drive to FRB davit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 October 2016
Resolved 17 February 2017
Navigation › Voyage Data Recorder › Voyage Data Recorder (VDR)
Issued 11 July 2016
Resolved
Repair the VDR and provide technician report. SOLAS/ CHAPTER v Reg, 20
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 July 2016
Resolved 25 July 2016
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 31 March 2016
Resolved
Make permanent repairs to the pin hole leak S.W. pipe shaft bearing cooling located aft STBD lower level main tranverse bulkhead engineroom.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 26 April 2016
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 22 February 2016
Resolved
Repair watertight Door #1,Electric controls are required to operate from the Bridge. ASTM F-1197 class III. 46 CFR 171
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2016
Resolved 26 August 2016
Documentation › Logs/Records › Record Book of Engine Parameters
Issued 22 February 2016
Resolved
Submit Periodic Safety Test Procedures to the CG Marine Safety Center (MSC) 46 CFR 61.40
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 June 2016
Resolved 20 April 2016
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 22 February 2016
Resolved
Submit test procedures for the auxiliary boiler to the CG Marine Safety Center (MSC) 46 CFR 63.10
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 June 2016
Resolved 20 April 2016
Deck/Cargo › Cargo Stowage › General
Issued 22 February 2016
Resolved
Repair car deck CO Monitor A ch 16, 17 and 18. 46 CFR 78.83
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 June 2016
Resolved 26 April 2016
Deck/Cargo › Cargo Stowage › General
Issued 22 February 2016
Resolved
Repair car deck CO Monitor B ch 12, 16, 17 and 18. 46 CFR 78.83
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 June 2016
Resolved 3 May 2016
Engineering › Generator (propulsion-electric) › Wiring
Issued 14 February 2016
Resolved
Generator lead is overheating.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 15 March 2016