Inspection history · 17
31 October 2025
Administrative Inspection · Internal Structural Exam · Plan Review "T" Boat · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8261464
3 October 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8246067
22 May 2025
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8141236
5 December 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7834127
18 October 2023
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7810555
28 September 2023
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7799264
13 September 2023
Administrative Inspection · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7791008
4 October 2022
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7571398
17 August 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7289390
2 December 2020
Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7104188
2 July 2020
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6978113
6 December 2019
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6868949
2 January 2019
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6604892
15 August 2018
Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6512585
15 August 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6241706
9 December 2016
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6055118
16 May 2016
DAPI Audit · Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5878280
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 October 2025
No resolution recorded
Owner or managing operator shall make a vessel available for dry dock examinations according to this section; a vessel that is exposed to salt water more than three months in any 12 month period since the last exam must undergo a dry dock examination and an internal structural exam at least every two years. Vessel failed to conduct its dry dock exam with the date given on the COI, 30SEP25. Vessel is restricted from carrying passengers until dry dock exam is complete.
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 May 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel had 01 deteriorated life jacket that required replacement. Vessel is restricted to a maximum of 19 total persons onboard.
46 CFR 180.71 (a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 October 2025
Resolution: MI observed new life jacket.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 May 2025
Resolved
Each ring life buoy on a vessel must: Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Life ring buoy onboard was deteriorated and required replacement.
46 CFR 180.70 (b)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2025
Resolved 6 October 2025
Resolution: MI observed new lifebuoy
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 May 2025
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Vessel missing label for number of life jackets in stowage compartments.
46 CFR 185.604 (f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2025
Resolved 6 October 2025
Resolution: MI observed marking for adult life jacket at stowage location.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 May 2025
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Remote fuel shutoff station not labeled.
46 CFR 185.608
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2025
Resolved 6 October 2025
Resolution: MI observed labeling of remote fuel shutoff location.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 May 2025
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. Vessel did not have attached lanyards for fire buckets.
46 CFR 181.610
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2025
Resolved 6 October 2025
Resolution: MI observed adequate lanyards attached to fire buckets.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 May 2025
No resolution recorded
A vessel on a rivers route must carry:
(1) Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and
(2) Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant.
Vessel had 4 total distress signals (day and night approved) and are expiring May 2025.
46 CFR 180.68 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2025 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 September 2023
Resolved
Vessel missed drydock due 31Dec2022. Vessel shall complete credit drydock prior to carrying passengers. 46CFR176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 September 2023
Resolved 18 September 2023
Resolution: Vessel completed credit drydock.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 17 August 2021
Resolved
An emergency instruction placard containing the following information will satisfy the requirements of 185.510. Vessel was missing emergency instruction placard.
46CFR185.512
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2021
Resolved 25 September 2021
Resolution: O/O sent in photo evidence of deficiency rectification.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 17 August 2021
Resolved
The master shall conduct sufficient drills. Vessel did not conduct sufficient drills. (Fire, man overboard and abandon ship.)
46 CFR 185.520(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2021
Resolved 4 October 2022
Resolution: VSL demonstrated drills.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 August 2021
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked. Labeling of child PFDs was faded.
46 CFR 180.78(a)(5)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2021
Resolved 25 September 2021
Resolution: O/O sent in photos of labeled life jackets.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 August 2021
Resolved
A vessel... must have at least three 2.5 gallon fire buckets... The words "FIRE BUCKET" must be stenciled in a contrasting color. One fire bucket was missing stencil.
46 CFR 181.610
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2021
Resolved 25 September 2021
Resolution: O/O sent in photo evidence of deficiency rectification.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 August 2021
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in a conspicuous place. Vessel did not have a PFD donning placard.
46 CFR 185.516(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2021
Resolved 25 September 2021
Resolution: O/O sent in photo evidence of deficiency rectification. Placard is posted.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 December 2019
Resolved
Each certificated vessel must undergo an annual inspection within three months before or after each anniversary date. JOYCE ANN's certification date is 16MAY2016, and thus was required an Annual Inspection no later than 16AUG2019. Vessel may not carry passengers until an Annual Inspection is completed to the satisfaction of the attending Marine Inspector. - 46 CFR 176.500 (b) (1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 2 July 2020
Resolution: Completed renewal inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 January 2019
Resolved
Vessel is not allowed to operate until owner or operator makes vessel available for drydock examination.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 January 2019
Resolution: Vessel was subjected to a drydock inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 August 2018
Resolved
Vessel must pay overdue user fees.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 August 2018
Resolved 17 August 2018
Resolution: Owner made arrangements to pay userfees and forwared them to the attending inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 August 2018
Resolved
Vessel is required to have a total of six hand flares. Four are onboard, the vessel must procure two more hand flares.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 August 2018
Resolved 15 August 2018
Resolution: Owner procured the flares and installed them on the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 August 2018
Resolved
Owner must post the EAP hotline phone number where the crew can see it.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 17 September 2018
Resolution: Received photos from the vessel’s owner displaying that the EAP Hotline phone numbers had been posted on the vessels bulletin board
Operations/Management › Drills/Instruction › Not Conducted
Issued 16 May 2016
Resolved
JE01 Drills were not conducted due to lack of crew. Drills to be evaluated by CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 2 June 2016
Resolution: Satisfactory MOB and fire drills were conducted. Deficiency cleared.
Fire Fighting › Fire Bucket › Quantity
Issued 16 May 2016
Resolved
JE02 Provide correct number of fire buckets. (Vessel only has 2)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 2 June 2016
Resolution: Proper size and number of fire buckets were onboard vessel. Deficiency cleared.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 May 2016
Resolved
JE03 Provide proper first aid kit. (Missing Asprin and Ammonia Inhalents)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 2 June 2016
Resolution: A complete first aid kit was onboard vessel. Deficiency cleared.
Lifesaving › Hand Flares › Quantity
Issued 16 May 2016
Resolved
JE04 Provide correct number and type of hand flares for route. (has only 4 red hand flares)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 2 June 2016
Resolution: Sufficient hand flares for route were onboard vessel. Deficiency cleared.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 16 May 2016
Resolved
JE05 Properly mark PFDs with vessel name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 2 June 2016
Resolution: PFDs were properly marked. Deficiency cleared.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 16 May 2016
Resolved
JE06 Install cover plate on outlet box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 2 June 2016
Resolution: Cover was installed on outlet box. Deficiency cleared.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 16 May 2016
Resolved
JE07 Post Emergency Instructions.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 2 June 2016
Resolution: Emergency instructions including fire situations were posted onboard. Deficiency cleared.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 16 May 2016
Resolved
JE08 Provide vessel log book
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 2 June 2016
Resolution: Vessel log book was provided. Deficiency cleared.
Construction/Loadline › Structures › Superstructure
Issued 16 May 2016
Resolved
JE09 Provide plans of alterations made to vessel. (Modified head, moved helm location, moved seating)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 2 June 2016
Resolution: Sufficent plans were provided showing relocation of helm and seating. Deficiency cleared.