MAURY USCG vessel records Sign in
← All vessels

ANNIE A

ANNIE A is a 1963 passenger vessel (inspected). The Coast Guard has recorded 58 inspections since 1985, most recently in February 2022, along with 93 deficiencies — 13 with no resolution recorded — and 2 operational controls, 1 with no removal date recorded.

Records from 1985 to 2022. Most recent: inspection, 26 February 2022.

Built
1963
Last inspected
26 February 2022
Documentation
Expired · documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

WAY9622
Flag
UNITED STATES
367135460 (licence lapsed)
Maury page id
psix-44486

Inspections, by type

…with no type recorded11
…past their stated due date1
Years with a record 27 calendar years (1985–2022)
The 58 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)47.5 ft × 15.5 ft × 4.8 ft
Registered tonnagegross 26 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderZANE E ROCKEY · OCOSTA, WA, UNITED STATES · built 1963
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portEDMONDS, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Gross Ton
21 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WAY9622MMSI 367135460 · expired · compulsorily equipped · granted 18 August 2006, cancelled 29 October 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 58

26 February 2022 Type not recorded
No type recorded · USCGC TERRAPIN (WPB 87366) · USCG Northwest District (CGD-NW) · Activity 7405340
12 November 2015 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5770000
7 December 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4203963
26 September 2011 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4155279
3 November 2010 Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3885708
15 October 2007 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3080334
28 August 2006 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2762512
7 July 2006 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2704995
23 May 2006 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2656863
25 October 2005 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2535100
20 May 2005 Hull Examination · Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2363565
2 June 2004 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2086714
29 August 2003 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1890873
26 August 2003 Internal Structural Exam · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1888616
7 May 2002 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1614438
7 May 2002 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1616765
7 June 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 168032
6 June 2001 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1417301
16 May 2001 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1425112
18 January 2000 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1403025
7 May 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1452569
21 July 1998 Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1465976
28 August 1997 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 784895
17 June 1997 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 146227
17 June 1997 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 213954
17 June 1997 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1450048
22 January 1997 Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1392596
8 July 1996 Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1417979
22 August 1995 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 877613
27 June 1995 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1357210
12 October 1994 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1353656
20 July 1994 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1174441
14 July 1994 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 868518
1 July 1994 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1459884
23 May 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 165275
22 February 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1164312
30 August 1993 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1135059
26 March 1993 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 833870
28 August 1992 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1403552
27 December 1991 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 682393
1 October 1991 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1254018
30 July 1991 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1246304
30 July 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1246306
20 July 1990 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1225099
13 March 1990 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1224047
1 March 1990 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 919376
8 August 1989 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1198653
24 April 1989 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1349141
21 April 1989 Deficiency Check · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1340363
29 July 1988 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1341450
18 May 1988 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1351143
4 January 1988 Deficiency Check · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1007693
31 October 1987 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1328646
12 November 1986 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1014956
22 August 1986 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1296354
23 April 1986 Credit Drydock
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1308798
25 October 1985 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1302484
3 August 1985 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 990558

Deficiency record · 93

Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 May 2016 No resolution recorded
Vessel overdue for annual inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 August 2016 — due date passed with no resolution recorded
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 20 November 2015 No resolution recorded
Remove fuel tanks from vessel to make the hull's internal structure available for inspection. Remove water from the lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Hull › Keel
Issued 20 November 2015 No resolution recorded
Many floors throughout the vessel have lifeted off the keel and planking, indicating that the keel bolts/drifts have failed. Submit repair proposal to inspect and or renew all keel bolts/drifts. Address the removal of garboard seam caulking in this plan.
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Hull › Transverse Frame
Issued 20 November 2015 No resolution recorded
Repair broken frames and refasten proud plank on port side in the engine room. Submit repair proposal for frames. If the plank is to be removed, make area available for USCG inspection before re-installing the plank.
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Hull › Transverse Frame
Issued 20 November 2015 No resolution recorded
Submit repair proposal for cracked/broken floors in engine room and space fwd of engine room, under the accomodation space.
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Hull › Transverse Frame
Issued 20 November 2015 No resolution recorded
Submit repair proposal for 08 broken frames on the port side, 02 broken frames on the starboard side, and 03 rotted frames on the starboard side of the space fwd of engine room under accomodation space.
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Hull › Transverse Frame
Issued 20 November 2015 No resolution recorded
Submit repair proposal for 06 broken frames in the engine room starboard side.
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Hull › Strut/Cross Tie
Issued 20 November 2015 No resolution recorded
Refasten all wasted internal fasteners. Submit specs for fasteners to be used for refastening internal structural members (floors to frames, stringers to frames, deck beams to beam shelf, etc.)
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Hull › Transverse Frame
Issued 20 November 2015 No resolution recorded
Submit repair proposal for broken frame in lazarette, port side.
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Penetrations › Valve Flange
Issued 20 November 2015 No resolution recorded
Renew bedding plate for engine seawater suction sea valve.
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Hull › Keel
Issued 20 November 2015 No resolution recorded
Once floors have been re-fastened to the keel and frames, caulk garboard seam without the use of flashing.
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Hull › Hull Plating
Issued 20 November 2015 No resolution recorded
Re-caulk seams as needed.
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Sea-water System (primary cooling) › Valve
Issued 20 November 2015 No resolution recorded
Make sea valves available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 September 2011 Resolved
BURN CREAM AND EYE WASH EXPIRED, REQUIRE REPLACEMENT.
Due 26 October 2011
Resolved 27 October 2011
Operations/Management › Drills/Instruction › Not Conducted
Issued 26 September 2011 Resolved
NO DECKHAND AVALIABLE FOR DRILLS AT TIME OF INSPECTION. MUST PERFORM DRILLS PRIOR TO NOV 4 2011 WITH USCG INSPECTOR.
Action required: 705 - Other - as specified
Due 4 November 2011
Resolved 30 September 2011
Resolution: PERFORMED SATISFACTORY DRILLS WITH DECKHAND.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 26 September 2011 Resolved
VESSEL DOES NOT HAVE A FCC SAFETY CERTIFICATE.
Action required: 705 - Other - as specified
Due 27 October 2011
Resolved 27 October 2011
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 26 September 2011 Resolved
REVERSE NEUTRAL/HOT LEADS FOR AC RECEPTACLES
Action required: 705 - Other - as specified
Due 27 October 2011
Resolved 27 October 2011
Navigation › Piloting/Steering › Marine Charts
Issued 26 September 2011 Resolved
WORK LIST 1. NEW OR CORRECTED CHARTS 2. NOT ALLOWED WING NUT ON THE BATTERY TERMINAL 3. CABLE SUPPORT FOR WIRES BY THE STBD FUEL TANK
Action required: 705 - Other - as specified
Due 27 October 2011
Resolved 27 October 2011
Engineering › Fuel Oil Service System › Discharge Strainer
Issued 3 November 2010 Resolved
Fuel strainer is missing the required drip pan/flame bowl IAW 46 CFR 182.20-40(b)5.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2011
Resolved 27 January 2011
Resolution: Received photographic evidence that drip pan/flame bowl has been properly installed on the fuel strainer in question. all sat.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 3 November 2010 Resolved
Renew lanyard for floating waterlight on bottom lifefloat prior to carrying passengers at night.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 3 January 2011
Resolution: Received picture of renewed lanyard for floating waterlight on bottom lifefloat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 November 2010 Resolved
Renew floating waterlight lanyard, install required corrosion resistant clip, and renew retroreflective tape on ring lifebuoy.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 3 January 2011
Resolution: Received picture of proper lifebuoy arrangement.
Lifesaving › Lifefloat › Markings
Issued 3 November 2010 Resolved
Mark lifefloats with the vessel's name and capacity.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 3 January 2011
Resolution: Received picture of lifefloats with name and capacity properly marked.
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 3 November 2010 Resolved
Provide evidence of valid marine radio operator's permit.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 3 January 2011
Resolution: Received picture of valid marine operator''s permit.
Construction/Loadline › Hull › Longitudinal Frame
Issued 15 October 2007 Resolved
Rotted frames were found in the transom area and E/R of the vessel. Rotted frames need to be cut out and replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 November 2007
Resolved 30 October 2008
Resolution: Rotten frames renewed.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 23 May 2006 Resolved
Collision bulkhead has a remavable cover approx 1'X2' that is missing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 June 2006
Resolved 22 August 2006
Resolution: Insert reinstalled.
Engineering › Lubricating Oil Service System › Filter
Issued 23 May 2006 Resolved
Oil line running to oil filter has a leak approx 1 drip per second.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2006
Resolved 22 August 2006
Resolution: Leak repaired.
Engineering › Fuel Oil Service System › Filter
Issued 23 May 2006 Resolved
Fuel line running to the fuel filter is seeping, wrapped in an absorbant rag.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2006
Resolved 31 August 2006
Resolution: Fuel oil leak has been repaired.
Navigation › Piloting/Steering › Magnetic Compass
Issued 23 May 2006 Resolved
Light for magnetic compass not operting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2006
Resolved 31 August 2006
Resolution: Light provided for compass.
Fire Fighting › Fire Pumps › Impeller
Issued 23 May 2006 Resolved
Fire pump/bilge pump not producing water pressure.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2006
Resolved 22 August 2006
Resolution: Vessel has 3 fire buckets onboard.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 23 May 2006 Resolved
No proof of enrollment in a random drug and alchol program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2006
Resolved 22 August 2006
Resolution: Entered into random drug/alchol program.
Engineering › Bilge Water Management System
Issued 2 June 2004 Resolved
Vessel rep. unable to demonstrate proper operation of bilge high level alarms. LEGACY COMPONENT DESC: High level alarms
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2004
Fire Fighting › Fixed Fire Detection System
Issued 2 June 2004 Resolved
Vessel rep. unable to demonstrate proper operation of engine room fire/smoke detection alarms. LEGACY COMPONENT DESC: Flame Detectors
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2004
Resolved 3 June 2004
Navigation › Piloting/Steering
Issued 2 June 2004 Resolved
Operating station lacks an independent rudder angle indicator. LEGACY COMPONENT DESC: Rudder angle indicator
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2004
Engineering › Bilge Water Management System › Not Operational
Issued 2 June 2004 Resolved
All bilge high level alarms inoperable LEGACY COMPONENT DESC: High level alarm sensor
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 July 2004
Resolved 18 June 2004
Resolution: Witnessed satisfactory test of bilge high level alarm (audible & visual).
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 2 June 2004 Resolved
Operator unable to demonstrate smoke & fire detection alarm testing. LEGACY COMPONENT DESC: Smoke Detectors
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 July 2004
Resolved 18 June 2004
Resolution: Witnessed satisfactory test of smoke alarm.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 2 June 2004 Resolved
Vessel did not have a rudder angle indicator at operating station. LEGACY COMPONENT DESC: Rudder angle indicator
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 July 2004
Resolved 18 June 2004
Resolution: Vessel not required to have rudder angle indicator. Steering system not power operated.
Engineering › Steering Gear System
Issued 29 August 2003 Resolved
Demonstrate proper operation of vessel's steering gear system. LEGACY COMPONENT DESC: Ram
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 August 2003
Resolution: Bled hydraulic line removing air bubble. All Sat.
Lifesaving › Rigid Liferafts
Issued 29 August 2003 Resolved
Install CG Approved weak link on vessel's Lifefloat arrangement. LEGACY COMPONENT DESC: Weak Link
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 August 2003
Resolution: CG approved weak link installed.
Lifesaving › Lifebuoys
Issued 29 August 2003 Resolved
Properly mark lifebouy with vessel name. LEGACY COMPONENT DESC: Markings (ship name/port)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 August 2003
Resolution: Lifebouy properly marked with vessel name.
Lifesaving › Rigid Liferafts
Issued 29 August 2003 Resolved
Properly mark lifefloats with vessel name. LEGACY COMPONENT DESC: Markings
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 August 2003
Resolution: Lifeboats properly marked with vessel name.
Deck/Cargo › Mooring/Anchoring
Issued 29 August 2003 Resolved
Provide & retain on board vessel proper anchor & ground tackle. LEGACY COMPONENT DESC: Anchor
Action required: 705 - Other - as specified
Resolved 29 October 2003
Resolution: Anchor placed on board vessel.
Documentation › Certificates/Documents
Issued 7 May 2002 Resolved
MAKE VESSEL AVAILABLE FOR ANNUAL REINSPECTION BY AN ATTENDING COAST GUARD MARINE INSPECTOR PRIOR TO CARRYING PASSENGER. LEGACY COMPONENT DESC: Certificate of Inspection
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 7 May 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 7 May 2002 Resolved
Engine room fixed CO2 flooding system past due for annual service. Have system serviced prior to carrying passengers for hire.
Condition: Improper/Lack of Maintenance
Due 7 June 2002
Resolved 10 May 2002
Lifesaving › Liferaft Equipment › Paddle
Issued 7 May 2002 Resolved
Two paddles for one lifefloat are missing. Provide two paddles for second lifefloat prior to carrying passengers.
Due 7 June 2002
Resolved 10 May 2002
Lifesaving › Lifebuoys
Issued 7 May 2002 Resolved
Lifering buoy in disrepair. Provide lifering buoy in appropriate condition prior to carrying passengers.
Due 7 June 2002
Resolved 10 May 2002
Navigation › Collision/Grounding Avoidance
Issued 7 May 2002 Resolved
Ship's whistle inoperable. Repair and demonstrate sat operational test of ship's whistle prior to carrying passengers.
Action required: 705 - Other - as specified
Due 7 June 2002
Resolved 17 May 2002
Lifesaving › Liferaft Equipment › Electric Torch
Issued 7 May 2002 Resolved
Lifefloat light is inoperable. Replace battery/repair and demonstrate sat operational test of light.
Due 7 June 2002
Resolved 10 May 2002
Construction/Loadline
Issued 6 June 2001 Resolved
VESSEL NAME AND HAILING PORT LABELING PLATES REMOVED FOR PAINTING OF THE HULL IN DRYDOCK. REINSTALL PLATES.
Condition: Unknown
Due 14 June 2001
Resolved 7 May 2002
Lifesaving
Issued 6 June 2001 Resolved
VESSEL LIFE FLOAT IS STENCILED WITH OTHER VESSEL NAME. PAINT OVER/REMOVE OTHER NAME AND REPLACE WITH PROPER STENCILING OF VESSEL NAME.
Condition: Unknown
Due 14 June 2001
Resolved 7 May 2002
Lifesaving
Issued 6 June 2001 Resolved
LIFE FLOAT, FLOAT FREE LINK MISSING APPROVAL TAG. INSTALL APPROVED FLOAT FREE LINK.
Condition: Unknown
Due 14 July 2001
Resolved 7 May 2002
Engineering
Issued 6 June 2001 Resolved
MAIN ENGINE COOLING SYSTEM FLEXIBLE PIPING MISSING DOUBLE HOSE CLAMPS. INSTALL DOUBLE HOSE CLAMPS ON PIPING SYSTEM.
Condition: Unknown
Due 14 July 2001
Resolved 7 May 2002
Navigation
Issued 6 June 2001 Resolved
VESSEL MISSING COPY OF CG LIGHT LIST. PROVIDE COPY OF CG LIGHT LIST.
Condition: Unknown
Due 14 July 2001
Resolved 7 May 2002
Lifesaving
Issued 17 June 1997 Resolved
RELOCATE LIFE RING TO A READILY ACCESSIBLE LOCATION.
Condition: Unknown
Due 2 July 1997
Resolved 7 August 1997
Electrical
Issued 17 June 1997 Resolved
REMOVE DEAD END WIRES IN ENGINE ROOM.
Condition: Unknown
Due 2 July 1997
Resolved 28 August 1997
Construction/Loadline
Issued 17 June 1997 Resolved
REPLACE CRACKED BUTT BLOCK, STBD SIDE BOW, MINOR WEEP.
Condition: Unknown
Due 17 June 1997
Resolved 17 June 1997
Engineering
Issued 17 June 1997 Resolved
LABEL EMERGENCY FUEL SHUT OFFS.
Condition: Unknown
Due 2 July 1997
Resolved 7 August 1997
Engineering
Issued 17 June 1997 Resolved
INCREASE FUEL TANK VENT SIZE FROM 3/8" TO 5/8" FROM TANK_x001C_ TO THRU HULL FITTING.
Condition: Unknown
Due 2 July 1997
Resolved 28 August 1997
Lifesaving
Issued 17 June 1997 Resolved
MOUNT BRACKET FOR WATER LIGHT FOR LIFE FLOAT. CURRENTLY LINE FOR LIGHT IS SPLICED AROUND FLOAT, AND LINE IS TIED TO RAIL. SET IN FLOAT FREE ARRANGEMENT.
Condition: Unknown
Due 11 August 1997
Resolved 28 August 1997
Lifesaving
Issued 17 June 1997 Resolved
MOUNT WATER LIGHT FOR LIFE RING. BRACKET IS CURRENTLY TIED TO RAIL, NOT READY FOR QUICK RELEASE.
Condition: Unknown
Due 11 August 1997
Resolved 28 August 1997
Engineering
Issued 8 July 1996 Resolved
REMOVE FUEL TANK FOR HEATER & PROVIDE PLANS FOR NEW INSTALLATION. TO BE COMPLETED PRIOR TO TAKING PSGRS.
Condition: Unknown
Due 12 July 1996
Resolved 11 July 1996
Construction/Loadline
Issued 8 July 1996 Resolved
PROVIDE PROPER HOSE FOR BILGE/FIRE HAND PUMP. TO BE COMPLETED PRIOR TO TAKING PSGRS.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Construction/Loadline
Issued 8 July 1996 Resolved
REPAIR DAMAGE DONE BY ELECTROLYSIS ON VERTICAL BEAMS OF TRANSOM. TO BE COMPLETED PRIOR TO TAKING PSGRS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 July 1996
Resolved 8 July 1996
Lifesaving
Issued 8 July 1996 Resolved
PROVIDE LIFEJACKET DONNING INST. TO BE COMPLETED PRIOR TO TAKING PSGRS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 July 1996
Resolved 11 July 1996
Construction/Loadline
Issued 8 July 1996 Resolved
DRY DOCK VSL PRIOR TO TAKING PSGRS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 July 1996
Resolved 8 July 1996
Construction/Loadline
Issued 27 June 1995 Resolved
MARK BILGE MANIFOLD
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Construction/Loadline
Issued 27 June 1995 Resolved
SECURE HATCH COVER WITH CABLE OR CHAIN ATTACHMENT
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Navigation
Issued 27 June 1995 Resolved
INSTALL ANCHOR LIGHT AND DEMONSTRATE OPERATION OF SAME.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Accommodation/Occupational Safety
Issued 27 June 1995 Resolved
SECURE UPPER DECK RAILING.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Accommodation/Occupational Safety
Issued 27 June 1995 Resolved
SECURE LADDER TO UPPER DECK AT BOTTOM AND UPPER DECK.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Lifesaving
Issued 27 June 1995 Resolved
MARK AND ATTACH PADDLES TO LIFE FLOAT.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Construction/Loadline
Issued 27 June 1995 Resolved
SECURE AND MAKE WATERPROOF ACCESS PANEL FOR COLLISION BULKHEAD.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Construction/Loadline
Issued 27 June 1995 Resolved
PLACE TWO HOSE CLAMPS ON SEA VAVES BELOW THE WATERLINE AND VITAL SYSTEMS.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Engineering
Issued 27 June 1995 Resolved
INSTALL AND VENT DIESEL FUEL TANK FOR HEATER I.A.W. REGULATIONS.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Accommodation/Occupational Safety
Issued 27 June 1995 Resolved
PROVIDE MSD OVERFILL ALARM.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Electrical
Issued 27 June 1995 Resolved
REMOVE DEAD END WIRE IN ENGINE ROOM.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Lifesaving
Issued 1 July 1994 Resolved
MOUNT PLACARD INDICATING LOCATION OF CHILDREN'S LIFE JACKETS.
Condition: Unknown
Due 14 July 1994
Resolved 15 July 1994
Lifesaving
Issued 1 July 1994 Resolved
PROVIDE PADDLES FOR LIFEFLOAT. VESSEL RESTRICTED TO NO MORE THAN ONE MILE FROM SHORE UNTIL PADDLES ARE PROVIDED.
Condition: Unknown
Due 14 July 1994
Resolved 15 July 1994
Electrical
Issued 1 July 1994 Resolved
REMOVE OR END IN JUNCTION BOX DEAD-ENDED WIRES. STARBOARD ENGINE ROOM.
Condition: Unknown
Due 14 July 1994
Resolved 15 July 1994
Engineering
Issued 1 July 1994 Resolved
PROVIDE PLUG FOR STARBOARD SEA VALVE, AFT IN ENGINE ROOM.
Condition: Unknown
Due 14 July 1994
Resolved 15 July 1994
Engineering
Issued 1 July 1994 Resolved
RENEW AS ORIGINAL ALL FLAME SCREENS FOR FUEL TANK VENT PIPING.
Condition: Unknown
Due 1 July 1994
Resolved 1 July 1994
Navigation
Issued 1 July 1994 Resolved
REPAIR INOPERATIVE STERN LIGHT. VESSEL RESTRICTED TO DAYLIGHT OPERATIONS UNTIL REPAIRS ARE MADE.
Condition: Unknown
Due 14 July 1994
Resolved 15 July 1994
Documentation
Issued 30 August 1993 Resolved
CONDUCT SIMPLIFIED STABILITY TEST TO THE SATISFACTION OF THE ATTENDING U.S.COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 30 August 1993
Resolved 30 August 1993
Construction/Loadline
Issued 1 March 1990 Resolved
VOID FWD OF ENGINE COMPARTMENT UNDER DECK FLOOR LONG NO.6, 3FT TO STBD OF CENTER LINE IS FRACTURED.
Condition: Unknown
Due 1 March 1990
Resolved 1 March 1990
Construction/Loadline
Issued 1 March 1990 Resolved
UNDER DECK SUPPORT IN VOID FWD OF ENGINE COMPARTMENT BETWEEN FLOOR LONG NO.6 & NO.7 AT CENTER LINE HAS SHIFTED.
Condition: Unknown
Due 1 March 1990
Resolved 1 March 1990
Construction/Loadline
Issued 24 April 1989 Resolved
MAKE REPAIRS TO SISTERED FRAMES IN ACCORDANCE WITH NAVIGATION AND INSPEC- TION CIRCULAR 1-63 PRIOR TO 1 OCT 1989 TO THE SATISFACTION OF THE ATTENDINGC.G. MARINE INSPECTOR.
Condition: Unknown
Due 24 April 1989
Resolved 24 April 1989
Electrical
Issued 4 January 1988 Resolved
PROVIDE AS BUILT DRAWINGS OF ELECTRICAL INSTALLATIONS ABOARD THIS VESSEL. WIRING AND ASSOCIATED EQUIPMENT TO BE IN ACCORDANCE WITH 46 CFR 183.05. THIS REQUIREMENT TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI AND PRIOR TO 05FEB88.
Condition: Unknown
Due 4 January 1988
Resolved 4 January 1988
Construction/Loadline
Issued 31 October 1987 Resolved
PRESENT VESSEL FOR INTERNAL HULL EXAM, ESPECIALLY IN WAY OF GARBOARD TO KEEL SEAM PRIOR TO 01MAY88.
Condition: Unknown
Due 31 October 1987
Resolved 31 October 1987
Documentation
Issued 31 October 1987 Resolved
PRIOR TO CARRYING PASSENGERS, COMPLETE SATISFACTORY REINSPECTION.
Condition: Unknown
Due 31 October 1987
Resolved 31 October 1987
Unknown
Issued 22 August 1986 Resolved
REMOVE OR PROPERLY ATTACH RIGHT HAND UPPER LADDER RAIL ATTACHMENT, ON TOP DECK.
Condition: Unknown
Due 22 August 1986
Resolved 22 August 1986
Navigation
Issued 22 August 1986 Resolved
REPLACE OR PERMANENTLY REPAIR BROKEN PORT RADIO ANTENNAE. (DEMONSTRATE RADIO TRANSMISSION)
Condition: Unknown
Due 22 August 1986
Resolved 22 August 1986
Accommodation/Occupational Safety
Issued 22 August 1986 Resolved
INSTALL METALLIC VENT (VICE PVC PIPING) AND FLAME SCREEN ON FUEL TANK FOR GALLEY STOVE LOCATED ON UPPER DECK.
Condition: Unknown
Due 22 August 1986
Resolved 22 August 1986
Engineering
Issued 22 August 1986 Resolved
PROPERLY INSTALL EXISTING FLAME SCREENS ON PORT AND STARBOARD FUEL TANK VENTS.
Condition: Unknown
Due 22 August 1986
Resolved 22 August 1986
Unknown
Issued 3 August 1985 Resolved
INCREASE RAIL HEIGHT TO 42 INCHES IN ACCORDANCE WITH 46 CFR 177.35-1(B) AND(C). THIS DEFICIENCY WAS TO HAVE BEEN CORRECTED BY 23 AUGUST 1985.
Condition: Unknown
Due 3 August 1985
Resolved 3 August 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.