Records from 1984 to 2011. Most recent: inspection, 4 January 2011.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 42
4 January 2011
Load Line/Change of Employment · Uninspected Other
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3919460
22 December 2010
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3916565
9 September 1989
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1203417
6 June 1988
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1352398
16 May 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 484625
15 March 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 490651
9 March 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 517851
8 March 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 474191
15 December 1987
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 519893
3 December 1987
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 447191
8 October 1987
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 526659
27 August 1987
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1006703
24 August 1987
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1003422
8 August 1987
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 498982
18 May 1987
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1025462
30 April 1987
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 534408
30 January 1987
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 505395
21 January 1987
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1008709
20 January 1987
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1008027
31 October 1986
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 453330
29 October 1986
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1320057
24 October 1986
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1318340
25 September 1986
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 311632
29 August 1986
Credit Drydock
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1272743
24 July 1986
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 310338
17 July 1986
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 310204
27 May 1986
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1292585
25 May 1986
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 514411
18 May 1986
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 989313
18 May 1986
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 999815
7 May 1986
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 522363
28 February 1986
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1294803
15 January 1986
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 995351
3 January 1986
Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1303038
27 August 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 493877
26 August 1985
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1294965
6 July 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1290567
29 June 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 984412
12 June 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 518859
25 May 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1287678
27 December 1984
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 501931
22 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973580
Electrical
Issued 6 June 1988
Resolved
REPAIR OR REPLACE WIRING FOR PYROMETER ON STBY DSL GEN.
Condition: Unknown
Due 6 June 1988
Resolved 6 June 1988
Lifesaving
Issued 6 June 1988
Resolved
WEIGHT TEST PORT LIFE BOAT FALLS.
Condition: Unknown
Due 6 July 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 6 June 1988
Resolved
PROVIDE SOLAS LIFESAVING TRAINING MANUALS.
Condition: Unknown
Due 6 July 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 6 June 1988
Resolved
MAKE PERMANENT REPAIRS TO DEEP TANK VENTS #6 STBD, #7 PORT.
Condition: Unknown
Due 6 July 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 6 June 1988
Resolved
RENEW 5 RING LIFE BUOY BRACKETS WHERE WASTED. 2-MAIN DECK AFT HOUSE P/S. 2-01 DECK MAIN HOUSE STBD SIDE. 1-MAIN DECK FWD PORTSIDE.
Condition: Unknown
Due 6 July 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 6 June 1988
Resolved
UP DATE FIRE CONTROL PLANS-LOCATION OF EMERGENCY GEAR LOCKERS.
Condition: Unknown
Due 6 July 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 18 May 1987
Resolved
1. CONDUCT OPERATIONAL TEST AND WEIGHT TEST PORT LIFEBOAT AND DAVIT IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 18 May 1987
Resolved 18 May 1987
Engineering
Issued 18 May 1987
Resolved
2. SUBMITT REPAIR PROCEDURE TO REINFORCEMENT BARS ON MAIN CONDENSER.
Condition: Unknown
Due 18 May 1987
Resolved 18 May 1987
Navigation
Issued 25 September 1986
Resolved
33 CFR 164.33 U.S. COAST PILOT NOT CURRENTLY CORRECTED. PENALTY ACTION NOT TO FOLLOW DUE TO GOOD FAITH ATTEMPTS TO COMPLY.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 29 August 1986
Resolved
RENEW FIRST RUBBER EXPANSION JOINTS DOWNSTREAM AS NOTED. PORTSIDE: HIGH SUCTION FOR MAIN CONDENSER, SUCTION FOR DISTILLING PUMP, SANITARY PUMP, ANDFIRE PUMP; STARBOARD: LOW SUCTION FOR DIESEL GENERATOR, LOW SUCTION AND HIGH SUCTION FOR THE AUXILIARY CIRCULATING PUMPS AND SHAFT ALLEY FIRE PUMP.
Condition: Unknown
Due 29 August 1986
Resolved 29 August 1986
Construction/Loadline
Issued 29 August 1986
Resolved
REPAIR OR RENEW VENTILATION CLOSURES AS FOLLOWS: VENTILATION TRUNK FORWARD OF CARGO HATCH 7; PORT VENTILATION TRUNK FORWARD OF CARGO HATCH 6; PORT VENTILATION TRUNK FORWARD OF CARGO HATCH 4; AND STARBOARD VENTILATION TRUNKBETWEEN CARGO HATCHES 1 AND 2.
Condition: Unknown
Due 29 August 1986
Resolved 29 August 1986
Construction/Loadline
Issued 29 August 1986
Resolved
REPLACE MISSING CARGO HATCH DOGS AS FOLLOWS: CARGO HATCH 7, 1 PORTSIDE AND1 STARBOARD; CARGO HATCH 5, 1 PORTSIDE AND 1 STARBOARD; CARGO HATCH 4, 1 PORTSIDE AND 2 STARBOARD; AND CARGO HATCH 1, 1 STARBOARD SIDE.
Condition: Unknown
Due 29 August 1986
Resolved 29 August 1986
Construction/Loadline
Issued 29 August 1986
Resolved
REPAIR OR RENEW WASTED FOUNDATION FOR AFT PORT HINGE ON CARGO HATCH 6.
Condition: Unknown
Due 29 August 1986
Resolved 29 August 1986
Construction/Loadline
Issued 29 August 1986
Resolved
RENEW ENGINE ROOM BILGE INJECTION VALVE STRAINER.
Condition: Unknown
Due 29 August 1986
Resolved 29 August 1986
Construction/Loadline
Issued 29 August 1986
Resolved
RENEW HATCH COVER FOR ACCESS TO THE STORES AREA FORWARD OF THE STEERING FLAT.
Condition: Unknown
Due 29 August 1986
Resolved 29 August 1986
Construction/Loadline
Issued 3 January 1986
Resolved
REPAIR PORT WATERTIGHT SIDE DOOR. THIS DEFICIENCY WAS TO HAVE BEEN CORRECTED BY 15 JANUARY 1986.
Condition: Unknown
Due 3 January 1986
Resolved 3 January 1986
Construction/Loadline
Issued 29 June 1985
Resolved
MAKE NECESSARY REPAIRS TO HATCH SEALS AND DOGGING DEVICES TO ASSURE A WEATHERTIGHT SEAL CAN BE OBTAINED. UNTIL SUCH REPAIRS ARE MADE ALL HATCHES TO BE TEMPORARILY SEALED PRIOR TO DEPARTING FROM PORT. FINAL REPAIRS AND INSPECTION TO BE COMPLETED PRIOR TO 30 AUGUST 1985.
Condition: Unknown
Due 29 June 1985
Resolved 29 June 1985
Fire Fighting
Issued 25 May 1985
Resolved
PROVIDE AN EXTRA COPY OF THE APPROVED US COAST GUARD FIRE CONTROL PLAN IN AN ACCEPTABLE WEATHERTIGHT CANNISTER.
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Engineering
Issued 25 May 1985
Resolved
OPEN UP FIRE AND WATER SIDES OF STARBOARD BOILER FOR EXAMINATION
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Engineering
Issued 25 May 1985
Resolved
TEST REMOTE SHUTDOWNS (FUEL OIL SOLENOID AND FORCED DRAFT FAN) FOR STAR- BOARD BOILER.
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Engineering
Issued 25 May 1985
Resolved
TEST HIGH AND LOW WATER ALARMS ON PORT BOILER
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Engineering
Issued 25 May 1985
Resolved
REPAIR HIGH WATER ALARM (AUDIBLE) ON STARBOARD BOILER
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Engineering
Issued 25 May 1985
Resolved
INSTALL SPRAY GUARDS ON FUEL OIL FEED LINES TO BURNERS.
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Engineering
Issued 25 May 1985
Resolved
CLAIBRATE REMOTE WATER LEVEL GAUGE FOR STARBOARD BOILER.
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Unknown
Issued 25 May 1985
Resolved
INSTALL HANDLE ON RELIEF VALVE FOR CONTROL AIR RECEIVER
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Electrical
Issued 25 May 1985
Resolved
INSTALL COVERS ON HIGH AND LOW PRESSURE CUTOFFS ON #1 AND #2 REFERS (ELECTRICAL BOX)
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Construction/Loadline
Issued 25 May 1985
Resolved
REPAIR SOFT PATCH ON BILGE AND BALLAST PUMP PIPING STARBOARD SIDE LOWER LEVEL ENGINE ROOM.
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Construction/Loadline
Issued 25 May 1985
Resolved
PROVE WEATHERTIGHT INTEGRITY OF HATCH COVERS.
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Deck/Cargo
Issued 25 May 1985
Resolved
REPLACE FLAME SCREENS (7) PER WORKLIST.
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Deck/Cargo
Issued 25 May 1985
Resolved
RESTENCIL OR TAG ALL FUEL VENTS.
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Lifesaving
Issued 25 May 1985
Resolved
WEIGHT TEST STBD LIFEBOAT.
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Deck/Cargo
Issued 25 May 1985
Resolved
ACQUIRE BELT GUARD FOR AC SYSTEM FAN (FAN ROOM) 01-141-3.
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985
Lifesaving
Issued 25 May 1985
Resolved
ACQUIRE 12 SURVIVAL SUITS.
Condition: Unknown
Due 25 May 1985
Resolved 25 May 1985