Records from 1985 to 2011. Most recent: inspection, 7 January 2011.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 19 August 2008
Resolved
Must provide proof of crew's enrollment in DAPI program prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 August 2008
Resolution: Vessel owner provided proof of crew enrollment in DAPI program with a letter from consortium.
Stability › Unintentional Flooding › General
Issued 2 April 2007
Resolved
Double clamp flexible hose connections as needed throughout the engine compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 April 2007
Resolved
Properly support loose wires in engine compartment as indicated by Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 April 2007
Resolved
Remove household wire nut splices connections in the engine space and replace with crimp type connections.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Engineering › Freshwater System (cylinder head cooling) › Hose
Issued 2 April 2007
Resolved
Replace flexible hose in raw water cooling line on starboard engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 2 April 2007
Resolved
Secure battery box covers port and starboard engine compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 2 April 2007
Resolved
Repair electrical bond wire in way of port fuel fill piping.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Engineering › Steering Gear System › Hydraulic Hose
Issued 2 April 2007
Resolved
Replace worn hydraulic hose in way of steering gear system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 2 April 2007
Resolved
Provide portable lights at operating station and entrance to engine compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Navigation › Piloting/Steering › Marine Charts
Issued 2 April 2007
Resolved
Provide current chart of operating area.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Operations/Management › Passenger Operations › Safety Orientation
Issued 2 April 2007
Resolved
Provide passenger safety orientation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 2 April 2007
Resolved
Replace cracked bridge window.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 April 2007
Resolved
Replace expired first aid kit items as indicated by Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 April 2007
Resolved
Replace lanyard for floating waterlight in way of ring life buoy with 3/8" floating UV resistant line no more than 3-6ft in length or remove.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Resolution: Owner removed floating waterlight. Vessel is restricted to daylight operations only.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 2 April 2007
Resolved
Replace retro-reflective material on lifejackets as indicated by Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 2 April 2007
Resolved
Remove obsolete ground wire from lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Lifesaving › Lifefloat › Painter
Issued 2 April 2007
Resolved
Replace line connecting lifefloats and buoyant apparatus.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Lifesaving › Lifefloat › Lifeline
Issued 2 April 2007
Resolved
Replace grabline in way of 6-person lifefloat.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Lifesaving › Lifefloat › Painter
Issued 2 April 2007
Resolved
Replace painter in way of lifefloats and buoyant appartus.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Lifesaving › Buoyant Apparatus › Serviceable
Issued 2 April 2007
Resolved
Make proper repairs to seperated lip on Bouyant Apparatus.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 2 April 2007
Resolved
Replace and properly splice lifeline to lifering.
Action required: 703 - Prior to bunkering operations
Resolved 24 May 2007
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 2 April 2007
Resolved
Replace (01) child lifejacket. The vessel is restricted to the carriage of 9 persons weighing less than 90lbs. until complete.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Construction/Loadline › Hull › Transverse Frame
Issued 2 April 2007
Resolved
Make proper repairs to cracked frame in lazerette, 1st frame forward of stern, starboard side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Construction/Loadline › Hull › Transverse Frame
Issued 2 April 2007
Resolved
Make repairs to wasted frame in lazerette, 1st frame aft of watertight bulkhead, starboard side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 2 April 2007
Resolved
Replace wasted bit starboard side, aft.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 2 April 2007
Resolved
Replace cotterpin in way of castle nut, port and starboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Construction/Loadline › Hull › Stiffener
Issued 2 April 2007
Resolved
Replace through bolts in way of deck timber, port side tank space, just below forward watertight bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Construction/Loadline › Hull › Strut/Cross Tie
Issued 2 April 2007
Resolved
Remove angel hair from all affected areas of engine compartment overhead and treat.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Construction/Loadline › Hull › Strut/Cross Tie
Issued 2 April 2007
Resolved
Replace through bolts in way of deck timber throughout void #2 on both port and starboard sides.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Construction/Loadline › Structures › Transverse Bulkhead
Issued 2 April 2007
Resolved
Make repairs to rotted bulkhead in vicinity of bilge pipes aft compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Construction/Loadline › Structures › Deck Plating
Issued 2 April 2007
Resolved
Make repairs to support beams in vicinity of deck timbers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 2 April 2007
Resolved
Properly ventilate space and remove water from bilges.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Construction/Loadline › Hull › Transverse Frame
Issued 2 April 2007
Resolved
Make proper repairs to transverse web frame forward end of void #2 in vicinity of forward bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Construction/Loadline › Hull › Longitudinal Frame
Issued 2 April 2007
Resolved
Make proper repairs to starboard clamp forward in forepeak.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Construction/Loadline › Structures › Deck Plating
Issued 2 April 2007
Resolved
Make proper repairs to transverse overhead beam forward of engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Construction/Loadline › Hull › Hull Plating
Issued 2 April 2007
Resolved
Conduct underway sea trials to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Construction/Loadline › Hull › Side Shell
Issued 2 April 2007
Resolved
Seal all exposed seams on exterior hull as marked.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Construction/Loadline › Hull › Side Shell
Issued 2 April 2007
Resolved
Remove all epoxy from exterior hull and make ready for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2007
Construction/Loadline › Hull › Side Shell
Issued 2 April 2007
Resolved
Secure water ingress to fuel tank space from first three frames forward of aft bulkhead, port side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2007
Construction/Loadline › Hull › Side Shell
Issued 2 April 2007
Resolved
Renew wasted through bolt on aft bulkhead in fuel tank space, starboard side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Construction/Loadline › Hull › Side Shell
Issued 2 April 2007
Resolved
Secure water ingress to engine room from butt block located between frames 7&8, aft of forward bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2007
Construction/Loadline › Hull › Side Shell
Issued 2 April 2007
Resolved
Secure water ingress to forepeak coming from 3rd frame forward of bulkhead, starboard side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2007
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 21 April 2006
Resolved
Bilge pump not operational. Make inspection ready-prove proper operation to CG Marine inspector.
Condition: Unknown
Due 2 May 2006
Resolved 28 April 2006
Resolution: Viewed operational bilge pump.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 21 April 2006
Resolved
Renew PFDs. Use black Marker to write "Sea Wolf" on both sides of PFD. Those PFDs that require particular attention have been set aside by CGMI. Also renew, as discussed, the retro-reflective tape.
Condition: Damaged By Earlier Event
Due 2 May 2006
Resolved 28 April 2006
Resolution: Viewed updated PFD''s.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 21 April 2006
Resolved
Replace one missing child PFD.
Condition: Improper/Lack of Maintenance
Due 2 May 2006
Resolved 28 April 2006
Resolution: Repalced.
Lifesaving › Embarkation Appliances/Stations › Handholds
Issued 21 April 2006
Resolved
Renew/repair rescue platform as discussed with vessel rep. Points on platform that attach to vessel are rusted through and are no longer serviceable.
Condition: Improper/Lack of Maintenance
Due 2 May 2006
Resolved 28 April 2006
Resolution: Repaired.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 21 April 2006
Resolved
Provide proof of company drug and alcohol program.
Condition: Improper/Lack of Maintenance
Due 2 May 2006
Resolved 28 April 2006
Fire Fighting › Fire Hoses › Condition
Issued 21 April 2006
Resolved
Provide new hoses for fire fighting as discussed with vessel rep.
Condition: Improper/Lack of Maintenance
Due 2 May 2006
Resolved 28 April 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 April 2006
Resolved
Remove old radio wires in pilothouse as discussed.
Condition: Improper/Lack of Maintenance
Due 2 May 2006
Resolved 28 April 2006
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 April 2006
Resolved
Post a copy of COI in passenger cabin as discussed with vessel rep.
Condition: Improper Installation
Due 2 May 2006
Resolved 28 April 2006
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 21 April 2006
Resolved
Remove fuel from aft bilges and properly dispose.
Condition: Improper/Lack of Maintenance
Due 2 May 2006
Resolved 21 April 2006
Construction/Loadline › Hull › Bottom Plating
Issued 21 April 2006
Resolved
C/R deck planking #1 and #9 from King Plank, port side, engine room as discussed.
Condition: Improper/Lack of Maintenance
Due 2 May 2006
Resolved 28 April 2006
Construction/Loadline › Hull › Longitudinal Frame
Issued 21 April 2006
Resolved
Crop and renew 8th plank from covering board in Mezzanine as discussed.
Condition: Improper/Lack of Maintenance
Due 2 May 2006
Resolved 28 April 2006
Construction/Loadline › Hull › Hull Plating
Issued 21 April 2006
Resolved
crop and renew covering board forward of starboard bow as discussed.
Condition: Improper/Lack of Maintenance
Due 2 May 2006
Resolved 28 April 2006
Navigation › Piloting/Steering › Coast Guard Light List
Issued 19 July 2005
Resolved
Provide update Coast Guard Light List.
Due 26 July 2005
Resolved 3 August 2005
Resolution: Viewed updated CG Light List
Navigation › Piloting/Steering › US Coast Pilot
Issued 19 July 2005
Resolved
Provide updated US Coast Pilot.
Due 26 July 2005
Resolved 3 August 2005
Resolution: Viewed update US Coast Pilot.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 19 July 2005
Resolved
Provide new retro - tape for (1) child lifejacket.
Due 26 July 2005
Resolved 3 August 2005
Resolution: Lifejacket fitted with new retro tape.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 19 July 2005
Resolved
Properly secure electrical panel in main cabin.
Due 26 July 2005
Resolved 3 August 2005
Resolution: Electrical panel re - secured to bulkhead in main cabin.
Navigation
Issued 30 July 2003
Resolved
Provided current revision of the International Rules of the Road Publication (2D). LEGACY COMPONENT DESC: International Rules of the Road Pub
Action required: 705 - Other - as specified
Due 13 August 2003
Resolved 15 August 2003
Lifesaving
Issued 30 July 2003
Resolved
Provided and maintain a logs for lifesaving equipment maintenance and EPIRB testing. LEGACY COMPONENT DESC: Lifesaving equip/EPIRB testing log
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 August 2003
Resolved 15 August 2003
Lifesaving
Issued 30 July 2003
Resolved
Install new hydro release or provide proof of expiration date for hydro release currently in use. LEGACY COMPONENT DESC: EPIRB Hydrostatis Release
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 July 2003
Resolved 1 August 2003
Construction/Loadline
Issued 30 July 2003
Resolved
Replace in kind (glass) stbd bridge window. LEGACY COMPONENT DESC: Bridge window
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 August 2003
Resolved 15 August 2003
Lifesaving › Buoyant Apparatus
Issued 30 July 2003
Resolved
Replace retro-reflective tape on both sides to all 3 BA's. LEGACY COMPONENT DESC: Retro tape
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 August 2003
Resolved 15 August 2003
Lifesaving › Visual Distress Signals (General) › Condition
Issued 30 July 2003
Resolved
Replace water light clips on all BA's and lifebuoy with corrosive resistant.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 August 2003
Resolved 1 August 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 30 July 2003
Resolved
Replace first aid kit w/Coast Guard approved or equivalent.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 August 2003
Resolved 15 August 2003
Lifesaving › Lifebuoys
Issued 30 July 2003
Resolved
Replace lifebuoy
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 August 2003
Resolved 15 August 2003
Fire Fighting
Issued 30 July 2003
Resolved
Provide proper operation of heat sensor units in E/R. LEGACY COMPONENT DESC: Heat Sensor
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 August 2003
Resolved 15 August 2003
Engineering
Issued 30 July 2003
Resolved
Secure port E/R vent pipe LEGACY COMPONENT DESC: Vent Pipe
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 August 2003
Resolved 15 August 2003
Engineering
Issued 30 July 2003
Resolved
Secure electric submersible pump through hull fitting in E/R. LEGACY COMPONENT DESC: Through Hull Fitting
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 August 2003
Resolved 15 August 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 30 July 2003
Resolved
Install 2 inch distribution line past fixed fire fighting system orifices in E/R. Retest piping and provide certificate to [name withheld]: Piping
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 August 2003
Resolved 15 August 2003
Electrical › Electrical Distribution System (service)
Issued 30 July 2003
Resolved
Install blank to main distribution panel. LEGACY COMPONENT DESC: Switchboard
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 August 2003
Resolved 15 August 2003
Electrical
Issued 30 July 2003
Resolved
Remove or properly terminate dead end wires in port fwd cabin cable chase. LEGACY COMPONENT DESC: Dead end wires
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 August 2003
Resolved 15 August 2003
Fire Fighting › Fire Main
Issued 30 July 2003
Resolved
Make permanent repairs to firemain piping in E/R. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 August 2003
Resolved 15 August 2003
Fire Fighting › Nozzles
Issued 30 July 2003
Resolved
Provide commercial garden hose nozzle of good grade bronze or equivalent metal. LEGACY COMPONENT DESC: Type
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 August 2003
Resolved 15 August 2003
Engineering
Issued 30 July 2003
Resolved
Provide closure devices for E/R ventilation openings located on main deck. LEGACY COMPONENT DESC: Closures
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 13 August 2003
Resolved 15 August 2003
Fire Fighting › Fire Hydrants
Issued 30 July 2003
Resolved
Install handle to fire hydrant valve. LEGACY COMPONENT DESC: Handle
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 July 2003
Resolved 1 August 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 30 July 2003
Resolved
Install a sign on the port fwd cabin cable chase door alerting crew on location of CO2 pull box. LEGACY COMPONENT DESC: CO2 Pull Box Indicator
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 July 2003
Resolved 15 August 2003
Engineering › Bilge Water Management System
Issued 30 July 2003
Resolved
Provide 5 GPM portable bilge pump capable of reaching bottom of all voids. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 August 2003
Resolved 15 August 2003
Engineering › Steering Gear System
Issued 30 July 2003
Resolved
Make permanent repairs to port tiller arm LEGACY COMPONENT DESC: Tiller arm
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2003
Resolved 1 August 2003
Engineering › Steering Gear System
Issued 30 July 2003
Resolved
Secure hydraulic steering ram. LEGACY COMPONENT DESC: Hydraulic steering ram
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2003
Resolved 1 August 2003
Engineering › Bilge Water Management System
Issued 16 May 2002
Resolved
Prove proper operation of mezzanine bilge alarm. LEGACY COMPONENT DESC: Alarm
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 May 2002
Resolved 20 May 2002
Resolution: Witnessed proper operation of bilge alarm.
Engineering › Bilge Water Management System
Issued 16 May 2002
Resolved
Remove water and clean bilges. LEGACY COMPONENT DESC: Bilges
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 June 2002
Resolved 11 June 2002
Resolution: Water removed from bilges for inspection.
Engineering › Bilge Water Management System
Issued 16 May 2002
Resolved
Provide marine grade hose for submersible pump in engine room. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 May 2002
Resolved 24 May 2002
Resolution: Witnessed installation of marine grade hose.
Construction/Loadline › Penetrations
Issued 16 May 2002
Resolved
Make all watertight bulkhead penetrations watertight. (EX: Stbd aft in tank compt.) LEGACY COMPONENT DESC: Watertight Bulkhead
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 May 2002
Resolved 24 May 2002
Resolution: Witnessed repair of bulkhead penetrations.
Construction/Loadline › Penetrations
Issued 16 May 2002
Resolved
Remove "angel hair" from bulkhead penetration on exhaust system in tank compartment and preserve wood. LEGACY COMPONENT DESC: Pipe Flange
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2002
Resolved 24 May 2002
Resolution: Witnessed removal of angel hair and preservation of wood.
Construction/Loadline › Structures
Issued 16 May 2002
Resolved
Remove "angel hair" in engine room and preserve wood. LEGACY COMPONENT DESC: Interior
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2002
Resolved 11 June 2002
Resolution: Witnessed removal of "angel hair" in engine room and treatment with linseed oil.
Electrical
Issued 26 July 2001
Resolved
Repair/replace wire to bilge alarm in lazarette.
Condition: Unknown
Due 2 August 2001
Resolved 30 July 2001
Navigation
Issued 26 July 2001
Resolved
Provide new copy of charts for vessel's route.
Condition: Unknown
Due 2 August 2001
Resolved 14 August 2001
Engineering
Issued 26 July 2001
Resolved
Replace/repair oil(fuel) hose to port engine.
Condition: Unknown
Due 2 August 2001
Resolved 14 August 2001
Electrical
Issued 26 July 2001
Resolved
Service the electrical distribution panel to feed power to anchor windlass circuit breaker w/out drawing off the main circuit breaker.
Condition: Unknown
Due 7 August 2001
Resolved 14 August 2001
Lifesaving
Issued 26 July 2001
Resolved
Replace weaklink to buoyant apparatus(BA) to meet the specified number of persons occupied by them(BA). Must be 21 and over.
Condition: Unknown
Due 2 August 2001
Resolved 14 August 2001
Lifesaving
Issued 26 July 2001
Resolved
Replace EPIRB safety key tab.
Condition: Unknown
Due 2 August 2001
Resolved 14 August 2001
Construction/Loadline
Issued 17 April 2001
Resolved
Make watertight bulkhead between engine room and fuel tank compartment water tight.
Condition: Unknown
Due 6 May 2001
Resolved 17 April 2001
Construction/Loadline
Issued 17 April 2001
Resolved
Clean, inspect and replace if needed keel bolts IWO stem (6 bolts)_x001C_
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Fire Fighting
Issued 17 April 2001
Resolved
Provide firefighting cylinder caps for bottles.
Condition: Unknown
Due 30 May 2001
Resolved 14 August 2001
Construction/Loadline
Issued 17 April 2001
Resolved
LAZ - Replace 2 planks at centerline aft
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Construction/Loadline
Issued 17 April 2001
Resolved
fwd compartment - Add sister bolt to stbd side frame # 2.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Construction/Loadline
Issued 17 April 2001
Resolved
Fwd Compartment - Refasten stbd upper longitudinal stringer
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Construction/Loadline
Issued 17 April 2001
Resolved
Compartment 2 - Replace deck planking, stbd side, forward.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Construction/Loadline
Issued 17 April 2001
Resolved
Compartment 2 - Refasten frame at sheer strake (1 Frame fwd of aft bulkhead, stbd side)
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Accommodation/Occupational Safety
Issued 17 April 2001
Resolved
Engine Room - Reconnect PVC piping from sink tank.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Accommodation/Occupational Safety
Issued 17 April 2001
Resolved
Engine Room - Clean seating surfaces and make available for inspection MSD overboard discharge valves, stbd side.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Accommodation/Occupational Safety
Issued 17 April 2001
Resolved
Engine Room - Repair MSD overboard discharge
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Construction/Loadline
Issued 17 April 2001
Resolved
Compartment 4 - Replace deck planking port side at aft bulkhead and sheer.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Construction/Loadline
Issued 17 April 2001
Resolved
Throughout vessel - Scrape out angel hair and add wood preserver.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Engineering
Issued 17 April 2001
Resolved
Renew fuel tanks.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Construction/Loadline
Issued 17 April 2001
Resolved
Make repairs to main deck water tight watches._x001C_ Make forward hatch operable, make repairs to deck - port side of aft hatch.
Condition: Unknown
Due 6 May 2001
Resolved 17 April 2001
Engineering
Issued 17 April 2001
Resolved
Repair port and stbd tail shafts iwo fore and aft cutlass bearings. Repairto satisfaction of attending MI.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Engineering
Issued 17 April 2001
Resolved
Engine Room - Replace engine mount bolts. (2 outboard port side, 1 Inboard port side) (1 outboard stbd side, 1 Inboard stbd side)
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Construction/Loadline
Issued 17 April 2001
Resolved
Reinspect deck beam @ removal of deck planking.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Construction/Loadline
Issued 17 April 2001
Resolved
Fwd compartment- replace port and stbd deck planking (2 planks off CL)
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Engineering
Issued 17 April 2001
Resolved
Compartment 4 - Reconnect bonding wire and electrical wiring support brackets
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Construction/Loadline
Issued 17 April 2001
Resolved
Make repairs to bilge system, renew piping, valves, etc. as necessary.
Condition: Unknown
Due 6 May 2001
Resolved 17 April 2001
Construction/Loadline
Issued 6 May 1999
Resolved
Repair dogs for both fore peak and lazerette watertight hatches.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Deck/Cargo
Issued 6 May 1999
Resolved
Reinstall and prove proper operation of anchor windlass. (Removed during off season to prevent theft)
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Accommodation/Occupational Safety
Issued 6 May 1999
Resolved
Open up and properly vent mezzanine (void aft of collision bulkhead) significant moisture problems due to improperly closing the vents.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Lifesaving
Issued 6 May 1999
Resolved
Provide a rescue boat or suitable alternative; ie: a rescue platform.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Fire Fighting
Issued 22 January 1999
Resolved
Install a fixed fire fighting system in machinery spaces iaw USCG approved plans.
Condition: Unknown
Due 7 April 1999
Resolved 8 April 1999
Fire Fighting
Issued 22 January 1999
Resolved
Vessel is not to be operated with passengers for hire after 11Mar99 until the above requirements have been cleared to the satisfaction of an attending USCG marine inspector.
Condition: Unknown
Due 7 April 1999
Resolved 8 April 1999
Fire Fighting
Issued 22 January 1999
Resolved
Submit plans for review and approval for the installation of a fixed fire fighting system in the machinery spaces iaw 46CFR181.115(b) and 46CFR181.400.
Condition: Unknown
Due 7 April 1999
Resolved 8 April 1999
Electrical
Issued 19 May 1998
Resolved
PROCURE GLOBES FOR TWO LIGHT FIXTURES.
Condition: Unknown
Due 19 June 1998
Resolved 25 June 1998
Electrical
Issued 19 May 1998
Resolved
PROVIDE PROPER SUPPORT FOR ELECTRICAL WIRING IN ENGINE ROOM.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Lifesaving
Issued 19 May 1998
Resolved
PLACE NEW RETRO TAPE ON LIFEJACKETS AND BA(S).
Condition: Unknown
Due 19 June 1998
Resolved 25 June 1998
Electrical
Issued 3 June 1997
Resolved
REMOVE ALL EXCESS AND UNCONNECTED WIRING UNDER CONSOLE
Condition: Unknown
Due 6 June 1997
Resolved 26 June 1997
Electrical
Issued 3 June 1997
Resolved
REPAIR AND MAKE WATERTIGHT WINCH WIRING ON BOW
Condition: Unknown
Due 6 June 1997
Resolved 26 June 1997
Electrical
Issued 3 June 1997
Resolved
REPAIR AND MAKE WATERTIGHT BILGE PUMP WIRING AND PROVIDE SUITABLE SUPPORT
Condition: Unknown
Due 6 June 1997
Resolved 26 June 1997
Engineering
Issued 3 June 1997
Resolved
RENEW S/W SUCTION HOSE WITH WIRE REINFORCED HOSE ONB PMDE
Condition: Unknown
Due 17 June 1997
Resolved 26 June 1997
Electrical
Issued 3 June 1997
Resolved
PROVIDE WATERTIGHT OUTLET BOX FOR HORN WIRING ON PILOTHOUSE CABIN TOP
Condition: Unknown
Due 6 June 1997
Resolved 26 June 1997
Electrical
Issued 3 June 1997
Resolved
REMOVE UNCONNECTED WIRING ON CABIN TOP NEXT TO HORN
Condition: Unknown
Due 6 June 1997
Resolved 26 June 1997
Electrical
Issued 3 June 1997
Resolved
REMOVE EXCESS UNCONNECTED WIRING FM UNDER WHEEL STATION ON PILOTHOUSE
Condition: Unknown
Due 6 June 1997
Resolved 26 June 1997
Lifesaving
Issued 3 June 1997
Resolved
REMOVE HEATER AND STOVE PIPE FROM ACCOMODATION SPACE
Condition: Unknown
Due 17 June 1997
Resolved 26 June 1997
Engineering
Issued 3 June 1997
Resolved
DOUBLE NUT PORT AND STBD RED GEAR ENGAGEMENT LEVER CONNECTION
Condition: Unknown
Due 6 June 1997
Resolved 26 June 1997
Electrical
Issued 3 June 1997
Resolved
BRAEKER BOX FOR BOTH MDE'S DOES NOT HAVE WIRE CLAMPS INSTALLED_x001C_ _x001C_ _x001C_ ^
Condition: Unknown
Due 6 June 1997
Resolved 26 June 1997
Accommodation/Occupational Safety
Issued 3 June 1997
Resolved
BOTH MALE/FEMALE HEAD GREY WATER DISCHARGE LINES NOT CONNECTED TO TK.
Condition: Unknown
Due 16 June 1997
Resolved 26 June 1997
Electrical
Issued 3 June 1997
Resolved
REMOVE EXTENSION CORD WIRING FM VSL
Condition: Unknown
Due 6 June 1997
Resolved 26 June 1997
Electrical
Issued 3 June 1997
Resolved
PROVIDE WATERTIGHT OUTLET BOXES FOR WIRING ON PILOTHOUSE CABIN TOP
Condition: Unknown
Due 6 June 1997
Resolved 26 June 1997
Lifesaving
Issued 3 June 1997
Resolved
LIFERING HAD NYLON ROPE IN LIEU OF POLYPROPELENE
Condition: Unknown
Due 6 June 1997
Resolved 26 June 1997
Navigation
Issued 3 June 1997
Resolved
RENEW CORRODED HYD RAM BRACKET FOR STEERING RAM, ADDITIONALLYY THE HOLE FORTHE BOLT WAS BADLY ELONGATED
Condition: Unknown
Due 6 June 1997
Resolved 26 June 1997
Lifesaving
Issued 3 June 1997
Resolved
INSTALL LIFERAIL AROUND BA'S ON PILOTHOUSE CABIN TOP
Condition: Unknown
Due 17 July 1997
Resolved 26 June 1997
Engineering
Issued 3 June 1997
Resolved
RENEW PORT SHAFT PACKING IN ITS ENTIRETY
Condition: Unknown
Due 6 June 1997
Resolved 26 June 1997
Navigation
Issued 3 June 1997
Resolved
PROVIDE EPIRB CERTIFCATE OF REGISTRY
Condition: Unknown
Due 17 June 1997
Resolved 26 June 1997
Navigation
Issued 3 June 1997
Resolved
PROVIDE GPS AND DEPTH SOUNDER FOR RIN, EQUIPMENT NOT REQ'D BY REGS BUT IS INSTALLED.
Condition: Unknown
Due 6 June 1997
Resolved 26 June 1997
Unknown
Issued 3 June 1997
Resolved
PROVIDE BULLHORN FOR INTERNAL COMMS
Condition: Unknown
Due 17 June 1997
Resolved 26 June 1997
Fire Fighting
Issued 3 June 1997
Resolved
PROVIDE NEW B-II FIRE EXTINGUISHER ON BRIDGE
Condition: Unknown
Due 6 June 1997
Resolved 26 June 1997
Documentation
Issued 3 June 1997
Resolved
POST DAPI HOTLINE AND EMPLOYEE POLICY STATEMENT
Condition: Unknown
Due 26 June 1997
Resolved 26 June 1997
Lifesaving
Issued 3 June 1997
Resolved
STENCIL VESSEL NAME ON LIFE JACKET
Condition: Unknown
Due 17 June 1997
Resolved 26 June 1997
Lifesaving
Issued 3 June 1997
Resolved
PROVIDE NEW WEAK LINK FOR BA ON PILOTHOUSE
Condition: Unknown
Due 6 June 1997
Resolved 26 June 1997
Lifesaving
Issued 3 June 1997
Resolved
REFASTEN STBD LIFERAIL TO DECK
Condition: Unknown
Due 17 June 1997
Resolved 26 June 1997
Engineering
Issued 1 May 1996
Resolved
REMOVE HEATER IN PASSENGER SPACE
Condition: Unknown
Due 28 May 1996
Resolved 28 May 1996
Lifesaving
Issued 1 May 1996
Resolved
PROVIDE NINE ADDITIONAL PFD'S AND VSL MAY NOT CARRY MORE THEN 89 PASSENGERSUNTILL REQUIREMENT IS MET.
Condition: Unknown
Due 28 May 1996
Resolved 28 May 1996
Lifesaving
Issued 1 May 1996
Resolved
PROVIDE WATERTIGHT CONTAINER FOR DISTRESS SIGNALS, MARKED AND COLORED
Condition: Unknown
Due 28 May 1996
Resolved 28 May 1996
Lifesaving
Issued 1 May 1996
Resolved
PROVIDE EMERGENCY BROADCAST PLACARD
Condition: Unknown
Due 28 May 1996
Resolved 28 May 1996
Lifesaving
Issued 1 May 1996
Resolved
PROVIDE PERSONAL FLOATATION DEVICE DONNING INSTRUCTIONS FOR EACH TYPE OF PFD ONBOARD.
Condition: Unknown
Due 28 May 1996
Resolved 28 May 1996
Engineering
Issued 26 April 1995
Resolved
REPLACE FLEX HOSE ON EACH FUEL FILL LINE, AND PROPERLY BAND NEW HOSE.
Condition: Unknown
Due 10 May 1995
Resolved 10 May 1995
Construction/Loadline
Issued 26 April 1995
Resolved
CLEAN OR REPLACE SCREENS FOR INSTALLED BILGE SUCTIONS IN EACH COMPT.
Condition: Unknown
Due 10 May 1995
Resolved 10 May 1995
Engineering
Issued 26 April 1995
Resolved
PROPERLY SECURE FUEL VENT PIPING AND REPLACE PORT FUEL VENT FLEX HOSE.
Condition: Unknown
Due 10 May 1995
Resolved 10 May 1995
Fire Fighting
Issued 18 May 1994
Resolved
PROVIDE EITHER EVIDENCE OF 6 YEARS SEVICING FOR B-1 EXTINGUISHER OR NEW B-1EXTINGUISHER. THIS REQUIREMENT MAY BE SATISFIED WITH A FAX OF PROPER DOCUMENTATION TO THE MARINE INSPECTION OFFICE.
Condition: Unknown
Due 26 October 1994
Resolved 26 October 1994
Accommodation/Occupational Safety
Issued 23 April 1993
Resolved
PROVE PROPER OPERATION OF BOTH MALE AND FEMALE BASINS. REPAIR AS ORIGINAL OR SUBMIT PLANS TO NYCMI-MIO FOR APPROVAL.
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Documentation
Issued 23 April 1993
Resolved
PROVIDE PROOF OF PARTICIPATION IN APPROVED CHEMICAL TESTING PROGRAM.
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Lifesaving
Issued 6 May 1991
Resolved
PROVIDE 23 USCG APPROVED ADULT PFD'S. PASSENGERS CARRY IS RESTRICTED TO 63PERSONS, UNTIL 23 PFD'S ARE PLACED OBOARD.
Condition: Unknown
Due 6 May 1991
Resolved 6 May 1991
Lifesaving
Issued 6 May 1991
Resolved
TO COMPLETE THE REQUIREMENTS OF THE REINSPECTION AN UNDERWAY EXAM IS NECESSARY.
Condition: Unknown
Due 6 May 1991
Resolved 6 May 1991
Deck/Cargo
Issued 1 May 1990
Resolved
REPAIR REACH ROD TO FOREPEAKE BILGE SUCTION VALVE.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Lifesaving
Issued 1 May 1990
Resolved
PLACE PROPER AMOUNT OF REFLECTIVE TAPE ON BOTH 20 MAN BUOYANT APPARATUS ANDRING BUOY.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Engineering
Issued 1 May 1990
Resolved
PROPERLY MARK BILGE MANIFOLD.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Engineering
Issued 1 May 1990
Resolved
PROVIDE FLAME GUARDS FOR RACOR FUEL FILTERS.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Engineering
Issued 1 May 1990
Resolved
PROPERLY MARK FUEL SHUT OFF VALVES.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Navigation
Issued 1 May 1990
Resolved
PROVIDE EMERGENCY CHECK OFF LIST.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Construction/Loadline
Issued 1 May 1990
Resolved
INSTALL CHAIN ON FOREPEAKE HATCH COVER.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Construction/Loadline
Issued 3 March 1989
Resolved
MAKE WATERTIGHT THE BULKHEAD BETWEEN FUEL TANK SPACE AND AFTER PEAK.
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Construction/Loadline
Issued 3 March 1989
Resolved
REPLACE THE WASTED FUEL TANK GROUNDING WIRE.
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Construction/Loadline
Issued 3 March 1989
Resolved
REPLACE THE TWO OUTBOARD DECK PLANKS ON STARBOARD QUARTER BETWEEN TRANSOM AND SAMPSON POST.
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Accommodation/Occupational Safety
Issued 7 October 1987
Resolved
INSTALL SECOND COURSE OF RAILING IN WAY OF PORT BOW.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Construction/Loadline
Issued 7 October 1987
Resolved
PROPERLY MARK VESSEL'S NAME AND HAILING PORT ON STERN.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Accommodation/Occupational Safety
Issued 15 May 1987
Resolved
PROVE PROPER OPERATION OF BOTH WASH BASINS AND THE TOILET IN THE MALE HEAD.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987