Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)130.0 ft × 34.0 ft × 7.0 ft
Registered tonnagegross 259 / net 259
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCONRAD INDUSTRIES INC · MORGAN CITY, LA, UNITED STATES · built 1996
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it259 - Simplified, Gross Ton 259 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 37
1 May 2025COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8128656
24 June 2024Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7941481
23 January 2024Periodic Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7853578
16 November 2022Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7596712
Vessel must undergo a periodic inspection within 3 months before or after the second or third anniversary of the date of the vessel's Certificate of Inspection (COI). The COI anniversary date is 26AUG2023; the vessel's periodic inspection was due no later than 26NOV2023; the vessel completed the periodic inspection on 23JAN2024. 46CFR31.10-17(b)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 23 January 2024
Resolved 23 January 2024
Resolution: Vessel completed periodic inspection on 23JAN2024.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 5 September 2019Resolved
Cargo pump pressure gauge shall be tested at least once a year for accuracy. Installed pressure gauge did not have any supporting documentation or tags indicating it was tested. Test gauge or provide a replacement that has been tested prior to conducting cargo operations. 46 CFR 35.35.70
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2020
Resolution: Corrected at 2020 annual inspection
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 5 September 2019Resolved
Cargo hose carried onboard must meet additional requirements contained in 33 CFR 154.500 which state hose must be labeled with the words "OIL SERVICE" Corrected on the spot.46 CFR 32.50-30, 33 CFR 154.500(e)(2).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2019
Resolution: Hose was stenciled.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 September 2019Resolved
The side lights of vessel of 20 meters or more in length shall be fitted with matt black inboard screens. The horizontal sectors of the nav light screen had worn down to a light colored primer. Corrected on the spot. 33 CFR 84.05(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 September 2019
Resolution: Nav Light screens were all painted matt black.
Engineering › Fuel Oil Service System › Hose
Issued 21 August 2013Resolved
Non-Metallic Flexible hose on Prime mover is greater than 30".
Condition: Improper Installation
Due 28 August 2013
Resolved 19 September 2013
Construction/Loadline › Hull › Side Shell
Issued 19 November 2007Resolved
Inset located on port quarter. Needs to be cropped and renewed to original.
Action required: 705 - Other - as specified
Due 21 January 2008
Resolved 7 January 2008
Resolution: completed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 September 2006Resolved
Vessel over due for drydocking by 12 days. Issued NOV TK:00127144.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 13 September 2006
Resolved 13 September 2006
Stability
Issued 14 August 2003Resolved
Provide on board prior to loading cargo vessel's stability letter.
Action required: 705 - Other - as specified
Due 14 September 2003
Resolved 18 August 2003
Resolution: Provided.
Provide annual hydro static testing of cargo piping.
Action required: 705 - Other - as specified
Due 14 September 2003
Resolved 4 January 2004
Resolution: Cargo piping hydrostatically tested this date.**** Description of deficiency was entered into the incorrect System, when originally entered.****
Deck/Cargo
Issued 21 September 2000Resolved
PROVIDE DOCUMENTATION OF A SATISFACTORY HYDROSTATIC TEST ON THE CARGO TRANSFER PIPING BY 21OCT00.
Condition: Unknown
Due 14 September 2015
Resolved 14 September 2015
Resolution: Legacy deficiency closed.
Deck/Cargo
Issued 3 September 1998Resolved
PROVIDE ONBOARD A CARGO PUMP DISCHARGE GAGE, VISIBLE FROM PUMP CONTROLS.
Condition: Unknown
Due 3 October 1998
Resolved 16 September 1998
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.