Records from 1996 to 2012. Most recent: inspection, 30 January 2012.
Inspection history · 22
30 January 2012
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4249682
13 January 2012
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4224454
3 February 2011
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3935217
30 January 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3935853
29 January 2010
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3679301
6 January 2010
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3660792
20 July 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3540968
3 October 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3337974
1 August 2008
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3285824
23 July 2007
In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3006751
17 July 2007
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2991415
10 July 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2990575
26 July 2005
PII Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2439536
16 October 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1929432
10 October 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1945789
8 October 2003
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2005542
14 February 2001
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 286892
14 October 1999
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 433768
13 March 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 426489
27 February 1998
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 413239
8 August 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 394067
7 August 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 393899
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 3 February 2011
Resolved
1499 - Other ( Prop. & Aux. Machinery ) - Each bunker line transfer pipe muse be tested annually and not leak under static liquid pressure at least 1.5 times the maximum allowable working pressure. Vessel conducted test, however, air was used as medium. Vessel is prohibited from conducting bunkering operations in US waters until bunker line is static liquid pressure tested. - 33CFR 155.820.
Action required: 703 - Prior to bunkering operations
Due 3 February 2011
Resolved 18 February 2011
Resolution: Received, reviewed and accepted proper documentation satisfying the requirement.
Navigation › Collision/Grounding Avoidance › Radar
Issued 3 February 2011
Resolved
1530 - Radar - All ships of 300 gt and above shall be fitted with a 9GHz radar to determine and display the range and bearing of radar transponders. Vessel reported an inoperable radar and was granted a Letter of Deviation to transit the Lower Mississippi River. Vessel must submit a technician's report attesting to satisfactory operation prior to departure. - SOLAS 74 am. V/19.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2011
Resolved 6 February 2011
Resolution: Received, reviewed, and accepted proper documentation from Sperry Marine stating the deficiency was rectified. Technician reloaded radar computer and updated software. Radar checks were satistactory and normal operation restored.
Navigation
Issued 14 February 2001
Resolved
INOPERATIVE SECONDARY MARINE RADAR, REPAIRS TO BE MADE PRIOR TO DEPARTURE
Condition: Unknown
Due 14 February 2001
Resolved 15 February 2001
Electrical
Issued 13 March 1999
Resolved
MISSING NON-CONDUCTING MAT OR GRATING IN FRONT OF SWITCHBOARD IN EMERGENCY GENERATOR ROOM. SOLAS74 II-1REG45.2. PROVIDE NON-CONDUCTING MAT OR GRATING IN FRONT OF SWITCHBOARD IN EMERGENCY GENERATOR ROOM; TO BE CORRECTED PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 15 October 1999
Resolved 15 October 1999