MAURY USCG vessel records Sign in
← All vessels

YUEHAI

YUEHAI is a 1996 freight ship. The Coast Guard has recorded 24 inspections since 1996, most recently in March 2016, along with 13 deficiencies and 2 operational controls.

Records from 1996 to 2016. Most recent: inspection, 7 March 2016.

Built
1996
Last inspected
7 March 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9109926 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
445203
Flag
PANAMA
—
Maury page id
psix-445203

Inspections, by type

…with no type recorded12
Years with a record 12 calendar years (1996–2016)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it26063 - Convention (Subpart B), Gross Ton
14924 - Convention (Subpart B), Net Ton
53181 - Displacement, Metric Ton
45632 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

7 March 2016 Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5828069
22 February 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5813368
25 April 2008 MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3192006
20 October 2006 NPV Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2804421
23 March 2006 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2608012
21 March 2006 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2606097
14 February 2006 Spot Check · PII Safety Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2578653
2 June 2005 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2376559
4 April 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2326371
21 March 2005 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2315174
17 May 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2070732
3 December 2002 Ballast Water Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1713913
9 January 2002 MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1475579
27 December 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1714508
18 December 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1714558
26 July 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 292295
15 May 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 277807
5 November 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 434514
29 June 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 429802
27 June 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 182288
16 March 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 426434
19 August 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 419482
28 April 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 525701
13 August 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 394074

Deficiency record · 13

Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 22 February 2016 Resolved
An administration which recognizes under regulation I/10 shall endorse such certificate to attest to its recognition only after ensuring the authenticity and validity of the certificate. Chief Engineer and 3rd Officer Flag State endorsements did not match National License.
Action required: 705 - Other - as specified
Due 22 March 2016
Resolved 24 February 2016
Resolution: Received proper Flag State endorsements for Chief Engineer and 2nd Officer that properly correlate to their national license.
Navigation › Collision/Grounding Avoidance › Transponder
Issued 2 March 2006 Resolved
Gyro compass input to AIS failed. AIS had no heading data. SOLAS V, Reg. 19.2.5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 March 2006
Resolution: Crew determined that a switch had disconnected the gyro from AIS.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 21 March 2005 Resolved
The Ballast Water Management Plan is not ship-specific.
Due 4 April 2005
Resolved 26 March 2005
Resolution: The Ballast Water Management plan has been made specifically for this vessel under Class supervision.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 21 March 2005 Resolved
The sewage treatment plant is not being maintained properly. The crew is not following the manufacturer's maintenance plan.
Due 4 April 2005
Resolved 26 March 2005
Resolution: Class inspected the unit additional maintenance requirements are now being inspected and recorded by the crew.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 21 March 2005 Resolved
Aft bulkhead in ECR has a hole; it compromises A-0 boundary.
Action required: 705 - Other - as specified
Due 4 April 2005
Resolved 26 March 2005
Resolution: Class has inspected this and found that the hole has been there since building the vessel. It was installed to add extra cooling to the back of the main switchboard.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 21 March 2005 Resolved
The garbage management plan needs to be updated. Paper and gasket material is being incinerated and needs to be added to the plan.
Due 4 April 2005
Resolved 26 March 2005
Resolution: Class inspected this and made corrections to the Garbage Management Plan.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 March 2005 Resolved
Vessel needs to provide documentation that rubber matting in front of electrical panning meets SOLAS II-1/45 requirement.
Due 4 April 2005
Resolved 26 March 2005
Resolution: Inspected by Class. Letter issued stating that vinyl matting meets the specifications of dielectric test of 30,000 volts.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 21 March 2005 Resolved
There are cracks in the bulkhead by the ECR door and window.
Action required: 705 - Other - as specified
Due 4 April 2005
Resolved 26 March 2005
Resolution: Inspected by Class. Vent is from original design.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 21 March 2005 Resolved
There are patches on the first stage of the oily water separator.
Action required: 705 - Other - as specified
Due 4 April 2005
Resolved 26 March 2005
Resolution: Class inspected the oily water separator. Both sections were ground down and inspected. The unit was tested under the supervision of Class and found in good working order.
Documentation
Issued 16 March 1999 Resolved
Provide vessel specific crew familiarization checklist prior to next U.S. Port. STCW 95 Section A-VI/1.
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Lifesaving
Issued 16 March 1999 Resolved
Provide lifeboat launching instructions in chinese at both boat decks priorto next U.S. Port. SOLAS 74 amd III/11.
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999
Lifesaving
Issued 16 March 1999 Resolved
Renew damaged lifeboat falls at port lifeboat and provide class report attesting to proper installation and satisfactory weight test. Complete prior to departure from this port. SOLAS 74 amd III/48.
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999
Documentation
Issued 13 August 1996 Resolved
COMPLETE BUNKER PROCEEDURES TO COMPLY WITH 33 CFR 155.750 PRIOR TO BUNKERING IN U. S. WATERS.
Condition: Unknown
Due 26 April 1997
Resolved 26 April 1997

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.