Records from 2016 to 2026. Most recent: inspection, 18 May 2026.
Documentation record
Registered dimensions (L × B × D)76.5 ft × 25.0 ft × 5.0 ft
Registered tonnagegross 82 / net 56
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTUCKER MARINE CONST CO · CINCINNATI, OH, UNITED STATES · built 1963
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSTILLWATER, MN
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 26 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it82 - Regulatory (Subpart C or D), Gross Ton
56 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 14
18 May 2026
Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 8373796
9 April 2025
COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 8090941
20 June 2024
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7939007
20 May 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7903418
17 May 2023
In-Service Inspection · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7675502
7 July 2022
Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7503400
27 October 2021
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7341154
13 May 2021
Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7199020
17 March 2020
COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6927896
13 June 2019
Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6713121
10 July 2018
Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6475372
24 July 2017
Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6177917
25 October 2016
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6029259
6 April 2016
Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 5849155
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 April 2025
Resolved
Each ring life buoy must be of an approved type, constructed IAW subpart 160.050 of this chapter, except a ring life buoy that was approved under former subpart 160.009 of this chapter may be used if it is in good and serviceable condition. Ring life buoy on 2nd deck was not of an approved type
46CFR180.30-1 (Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 April 2025
Resolution: O/O submitted objective evidence of new lifering
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 May 2024
Resolved
The sidelights of vessels of 20 meters or more in length shall be fitted with matt black inboard screens and meet the requirements of § 84.15. Vessel side lights not fitted with screens.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2024
Resolved 20 June 2024
Resolution: mate black screens installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 May 2024
Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Report of system servicing not provided for review on day of inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2024
Resolved 20 June 2024
Resolution: System report provided via email.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 July 2022
Resolved
Transmission fuel line is worn.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 July 2022
Resolution: Fuel line replaced.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 7 July 2022
Resolved
Watertight bulkhead aft engine room is corroded and the bottom, to the point there is a penetration through the hull.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 July 2022
Resolution: Temporary weld repairs have been completed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 July 2022
Resolved
PVC piping that is a through hull penetration needs to be metallic, and capped.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 July 2022
Resolution: A metal cap has been placed on the thru hull, plastic piping removed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 27 October 2021
Resolved
Replace existing starboard aft corner plate with in kind plate as several areas of deep pitting have occurred.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 November 2021
Resolution: new plate installed.
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 8 April 2020
Resolved
self reported one watertight door alarm inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2020
Resolved 10 April 2020
Resolution: alarm repaired
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 April 2020
Resolved
self reported one high bilge alarm inoperable
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2020
Resolved 10 April 2020
Resolution: alarm repaired
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 July 2017
Resolved
Extension cords were being used for the bilge system in the E/R. Replace with proper fixed source of power.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 2 August 2017
Construction/Loadline › Penetrations › Weld
Issued 6 April 2016
Resolved
Severe wastage, with through bulkhead penetration of approximately quarter sized, was noted on starboard side quarter superstructure bulkhead forward of the access door. Additionally, a fractured weld approximately 1.5" long and associated plate wastage was noted aft of the same door.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 8 April 2016
Resolution: Plates have been renewed.