Records in 1996. Most recent: inspection, 21 August 1996.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Electrical
Issued 21 August 1996
Resolved
REPAIR ENGINE EXHAUST LEAK AT MANIFOLD IN WAY OF THE SMALL SHIP'S SERVICE GENERATOR.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Documentation
Issued 21 August 1996
Resolved
PROVIDE A VALID COPY OF SHIP'S REGISTRY.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Construction/Loadline
Issued 21 August 1996
Resolved
POST A "DISCHARGE OF OIL PROHIBITED" PLACARD IN THE ENGINE ROOM.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Engineering
Issued 21 August 1996
Resolved
PROVIDE FROM VESSEL'S SURVEYOR, FUEL TANK CAPACITIES.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Lifesaving
Issued 21 August 1996
Resolved
PROVIDE A SURVEYOR'S REPORT PRIOR TO USCG EXAMINATION.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Lifesaving
Issued 21 August 1996
Resolved
COMPLETE A USCG EXAMINATION._x001C_
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Navigation
Issued 21 August 1996
Resolved
PAINT ON HULL, FORE & AFT DRAFT MARKS.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Accommodation/Occupational Safety
Issued 21 August 1996
Resolved
PROVIDE ON BOARD FOR REVIEW, CREW MEDICAL CERTIFICATES FOR ALL HANDS.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Documentation
Issued 21 August 1996
Resolved
PROVIDE ON BOARD PRIOR TO DEPARTURE ONE LICENSED MASTER, & ONE LICENSED MATE. _x001C_ _x001C_ **LICENSES AVAILABLE ON 15AUG96. CHECK AGAIN AT NEXT BOARDING.***
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Construction/Loadline
Issued 21 August 1996
Resolved
INSTALL AN OPERABLE BILGE SYSTEM WITH SUCTION PIPING SERVING ALL WATERTIGHTCOMPARTMENTS. _x001C_ _x001C_ ***VERY UNSAT. CAN'T TAKE SUCTION. MANY LEAKS. NO CHECK VALVE INSTALLED.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Accommodation/Occupational Safety
Issued 21 August 1996
Resolved
PROVIDE A WASTE MANAGEMENT PLAN. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Accommodation/Occupational Safety
Issued 21 August 1996
Resolved
START MAKING ENTRIES IN THE VESSEL GARBAGE LOG TODAY. _x001C_ _x001C_ _x001C_ ***AS OF 15AUG96. STILL NO ENTRIES****
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Navigation
Issued 21 August 1996
Resolved
PRIOR TO RETURNING TO U.S. WATERS, PROVIDE A CURRENT MAGNETIC COMPASS DEVIATION CARD.
Condition: Unknown
Due 9 September 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 August 1996
Resolved
INSTALL ONE ADDITIONAL FIRE STATION WITH HYDRANT, HOSE & NOZZLE.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Construction/Loadline
Issued 21 August 1996
Resolved
MAKE PERMANENT REPAIRS TO WASTED FRAMES IN CARGO HOLD & STEERING COMPARTMENT NO LATER THAN 06 OCTOBER 1996 & PROVIDE A SURVEYOR'S REPORT FORREVIEW.
Condition: Unknown
Due 6 October 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past