MAURY USCG vessel records Sign in
← All vessels

MARANATHA

MARANATHA is a 1964 freight ship. The Coast Guard has recorded 1 inspection in 1996, along with 15 deficiencies and 1 operational control.

Records in 1996. Most recent: inspection, 21 August 1996.

Built
1964
Last inspected
21 August 1996
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

445267
Flag
HAITI
—
Maury page id
psix-445267

Inspections, by type

…with no type recorded1
Years with a record 1 calendar year (1996)
The 1 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 30 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it72 - Regulatory (Subpart C or D), Gross Ton
54 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.

Inspection history · 1

21 August 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 394152

Deficiency record · 15

Electrical
Issued 21 August 1996 Resolved
REPAIR ENGINE EXHAUST LEAK AT MANIFOLD IN WAY OF THE SMALL SHIP'S SERVICE GENERATOR.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Documentation
Issued 21 August 1996 Resolved
PROVIDE A VALID COPY OF SHIP'S REGISTRY.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Construction/Loadline
Issued 21 August 1996 Resolved
POST A "DISCHARGE OF OIL PROHIBITED" PLACARD IN THE ENGINE ROOM.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Engineering
Issued 21 August 1996 Resolved
PROVIDE FROM VESSEL'S SURVEYOR, FUEL TANK CAPACITIES.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Lifesaving
Issued 21 August 1996 Resolved
PROVIDE A SURVEYOR'S REPORT PRIOR TO USCG EXAMINATION.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Lifesaving
Issued 21 August 1996 Resolved
COMPLETE A USCG EXAMINATION._x001C_
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Navigation
Issued 21 August 1996 Resolved
PAINT ON HULL, FORE & AFT DRAFT MARKS.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Accommodation/Occupational Safety
Issued 21 August 1996 Resolved
PROVIDE ON BOARD FOR REVIEW, CREW MEDICAL CERTIFICATES FOR ALL HANDS.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Documentation
Issued 21 August 1996 Resolved
PROVIDE ON BOARD PRIOR TO DEPARTURE ONE LICENSED MASTER, & ONE LICENSED MATE. _x001C_ _x001C_ **LICENSES AVAILABLE ON 15AUG96. CHECK AGAIN AT NEXT BOARDING.***
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Construction/Loadline
Issued 21 August 1996 Resolved
INSTALL AN OPERABLE BILGE SYSTEM WITH SUCTION PIPING SERVING ALL WATERTIGHTCOMPARTMENTS. _x001C_ _x001C_ ***VERY UNSAT. CAN'T TAKE SUCTION. MANY LEAKS. NO CHECK VALVE INSTALLED.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Accommodation/Occupational Safety
Issued 21 August 1996 Resolved
PROVIDE A WASTE MANAGEMENT PLAN. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Accommodation/Occupational Safety
Issued 21 August 1996 Resolved
START MAKING ENTRIES IN THE VESSEL GARBAGE LOG TODAY. _x001C_ _x001C_ _x001C_ ***AS OF 15AUG96. STILL NO ENTRIES****
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Navigation
Issued 21 August 1996 Resolved
PRIOR TO RETURNING TO U.S. WATERS, PROVIDE A CURRENT MAGNETIC COMPASS DEVIATION CARD.
Condition: Unknown
Due 9 September 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 August 1996 Resolved
INSTALL ONE ADDITIONAL FIRE STATION WITH HYDRANT, HOSE & NOZZLE.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Construction/Loadline
Issued 21 August 1996 Resolved
MAKE PERMANENT REPAIRS TO WASTED FRAMES IN CARGO HOLD & STEERING COMPARTMENT NO LATER THAN 06 OCTOBER 1996 & PROVIDE A SURVEYOR'S REPORT FORREVIEW.
Condition: Unknown
Due 6 October 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.