MAURY USCG vessel records Sign in
← All vessels

AVALON

AVALON is a 1963 passenger vessel (inspected). The Coast Guard has recorded 84 inspections since 1984, most recently in January 2026, along with 131 deficiencies, 1 operational control and 2 casualty investigations between 2005 and 2008.

Records from 1984 to 2026. Most recent: inspection, 21 January 2026.

Built
1963
Last inspected
21 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD7440
Flag
UNKNOWN
367186430
Maury page id
psix-44529

Inspections, by type

…with no type recorded7
Years with a record 38 calendar years (1984–2026)
The 84 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.8 ft × 26.9 ft × 7.6 ft
Registered tonnagegross 80 / net 64
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORP · WARREN, RI, UNITED STATES · built 1963
Hull materialSteel
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it80 - Regulatory (Subpart C or D), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD7440MMSI 367186430 · active · compulsorily equipped · granted 22 February 2017, expires 10 May 2027
WCV4791MMSI 366993040 · expired · voluntarily equipped · granted 22 November 1995, cancelled 28 January 2006
WCQ6430MMSI not assigned · expired · voluntarily equipped · granted 5 April 1995, cancelled 11 June 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 84

21 January 2026 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8299257
13 November 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8267822
27 January 2025 Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8070113
30 January 2024 MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7853819
22 January 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7852726
1 November 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7818785
30 May 2023 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7700136
20 January 2023 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7622717
15 October 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7336971
8 October 2021 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7503757
21 October 2020 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7082264
24 October 2019 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6840861
11 October 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6836254
29 October 2018 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6570436
4 October 2018 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6554827
5 September 2017 Internal Structural Exam · Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6260724
10 February 2017 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6085829
1 February 2017 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6081181
27 October 2015 MTSA Verification · Administrative Inspection · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5750711
16 July 2015 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5187030
12 May 2014 Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4856563
3 May 2012 MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4300914
19 January 2012 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4227743
3 February 2009 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3411637
13 July 2008 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3266121
12 July 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3269724
7 April 2008 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3179238
14 March 2007 COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2889059
22 February 2006 MARPOL Annex V Examination · Annual Inspection · Plan Review (Other than "T")
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2591165
26 June 2005 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2403483
26 June 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2478402
23 May 2005 Annual Inspection · MTSA Verification · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2365651
22 February 2005 Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2296784
12 April 2004 MARPOL Annex V Examination · Deficiency Check · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2042140
11 April 2003 MARPOL Annex V Examination · Deficiency Check · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2004217
7 March 2003 Hull Examination · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1755335
14 June 2002 Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1675042
25 April 2002 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1609246
18 April 2002 Deficiency Check · MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1609199
24 July 2001 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1069624
11 April 2001 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1445797
26 February 2001 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1418849
22 March 2000 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1435005
10 May 1999 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 794957
2 April 1999 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1365126
26 March 1999 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1114589
8 March 1999 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1369069
18 February 1999 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1410016
17 April 1998 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1122796
3 April 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1125692
13 June 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1110875
22 January 1997 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1106885
19 September 1996 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1457384
17 April 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1079943
15 June 1995 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 880337
12 June 1995 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 878945
13 December 1994 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1146567
22 June 1994 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1134422
20 May 1993 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 831977
16 March 1993 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1147683
15 June 1992 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 943259
29 May 1992 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 958686
21 October 1991 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 940754
16 September 1991 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1247022
6 September 1991 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1247174
5 September 1991 Drydock Extension
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1251313
21 May 1991 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1229367
1 June 1990 Damage Survey
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 922903
21 May 1990 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 931190
4 April 1990 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1215841
22 January 1990 Examination of Repairs
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 900149
23 May 1989 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1194796
6 October 1988 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1200270
22 September 1988 Drydock Extension
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1352503
17 June 1988 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1203047
30 June 1987 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1317866
26 May 1987 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1334137
24 March 1987 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1017205
23 March 1987 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1017317
23 June 1986 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1303208
22 October 1985 Credit Drydock
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1299766
16 May 1985 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 979967
30 October 1984 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 975475
21 May 1984 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1324854

Deficiency record · 131

10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 January 2025 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules... STBD navigation light was extinguished. 46 CFR 183.420
Action required: 705 - Other - as specified
Resolved 28 January 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 January 2024 Resolved
"Your vessel must undergo an annual inspection w/in 3 months before or after each anniversary date." Vessel missed its 3rd annual inspection for COI. The COI is now invalidated and the vessel will need to submit an application for a new COI. 46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 January 2024
Resolution: COI Renewal complete. Issued New 5 Year COI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2023 Resolved
Descale framing underneath MSD tank, as discussed.
Action required: 705 - Other - as specified
Resolved 13 November 2023
Resolution: The frames underneath the MSD tank were descaled, frames looked to be in good condition no further action required.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2023 Resolved
Descale the framing aft of the MSD tank as discussed.
Action required: 705 - Other - as specified
Resolved 8 November 2023
Resolution: The operator cropped and renewed the wasted 02 aft support frames under the MSD tank.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 1 November 2023 Resolved
Starboard and Port side engine frame cracked, crop and renew as marked.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 8 November 2023
Resolution: The starboard and port side frames supporting in the engine room have been cropped and renewed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2023 Resolved
Descale the bilge in way of shaft as marked.
Action required: 705 - Other - as specified
Resolved 8 November 2023
Resolution: Bilge in way of shaft was descaled, all bottom platting was in good condition.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2023 Resolved
Descale Starboard side forward to bulkhead in the engine room as marked.
Action required: 705 - Other - as specified
Resolved 8 November 2023
Resolution: The deck in the engine room next to the port side fuel tank has been descaled.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2023 Resolved
Descale in the steering flat as marked in all four bays.
Action required: 705 - Other - as specified
Resolved 8 November 2023
Resolution: All four bays have been descaled, during the decaling processes a pin hole was identified on port side next to port rudder. The plate was cropped and renewed by the operator.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2023 Resolved
Locate and descale the fixed ballast in accordance to with the Stability Letter.
Action required: 705 - Other - as specified
Resolved 8 November 2023
Resolution: The fixed ballast was descaled and found in good condition.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2023 Resolved
Demonstrate function the bilge system.
Action required: 705 - Other - as specified
Resolved 17 November 2023
Resolution: Vessel demonstrated proper operation of the bilge system.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 1 November 2023 Resolved
Demonstrate function of all fire dampeners in the engine room.
Action required: 705 - Other - as specified
Resolved 17 November 2023
Resolution: Inspected fire dampner repairs and ensured closure with no air gaps.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2023 Resolved
Provide description of any modification that have been made to the vessel since the Stability Letter was issued in 1963.
Action required: 705 - Other - as specified
Resolved 30 November 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2023 Resolved
The deck plating in the engine room near the port side fuel tank has to be cropped and renewed.
Action required: 705 - Other - as specified
Resolved 17 November 2023
Resolution: Vessel Cropped and renewed affected area.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 January 2023 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments, under all practical conditions. The vessels bilge system was not operating.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 January 2023
Resolution: Impeller was renewed on the pump. Witnessed operation drawing suction from forepeak and lazarrette.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 January 2023 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in the bilges. The floats for the high level alarms were not in serviceable condition.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 January 2023
Resolution: All bilge high level alarms replaced, operated and visible from the bridge.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 January 2023 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections. The distribution panels on the bridge and in the engine room were not totally enclosed.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 January 2023
Resolution: Closure devices installed on the electrical cabinet in the engine room and on bridge.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 20 January 2023 Resolved
Each officer employed on any vessel subject to this sub chapter must have his or her license or merchant mariner credential on board and available for examination at all times. Crew was not present at Annual inspection
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 January 2023
Resolution: License check completed tot he satisfaction of the attending MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 January 2023 Resolved
The owner, charterer, master or managing owner shall instruct each crew member as to the duties that the crew member is expected to perform in an emergency. MIs were not able to witness crew competency during inspection because no crew was in attendance. MIs must witness adequate drills, training records, and use of bridge equipment during follow up inspection.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 January 2023
Resolution: Underway boat and fire drills conducted to the satisfaction of the attending MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 October 2018 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. You must contact the cognizant OCMI to schedule an inspection at a time and place which he or she approves. No written application is required. Vessel has been operating outside of window for 2nd Annual, and is now due for a third Annual inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 October 2018
Resolution: Vessel had a satisfactory inspection.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 September 2017 Resolved
Complete satisfactory credit drydock and internal structural exams prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2017
Resolution: Completed satisfactory credit DD/ISE.
Lifesaving › Lifebuoys › Approval
Issued 10 February 2017 Resolved
Provide Q-spec for current ring buoys on board.
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 21 February 2017
Resolution: Received proper documentation attesting to approved lifesaving type.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 February 2017 Resolved
Vessel must complete 1st annual inspection, inspection is overdue.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2017
Resolution: Vessel completed satisfactory 1st annual inspection.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 3 February 2009 Resolved
Provide outlet cover for exposed outlet, 02 deck, as indicated.
Action required: 705 - Other - as specified
Due 9 March 2009
Resolved 10 March 2009
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 February 2009 Resolved
Properly support wiring for air conditioner unit in lazarette.
Action required: 705 - Other - as specified
Due 9 March 2009
Resolved 10 March 2009
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Construction/Loadline › Hull › Bottom Plating
Issued 13 July 2008 Resolved
Conduct dive survey of vessel hull and appurtenances and provide report of the same.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2008
Construction/Loadline › Hull › Bottom Plating
Issued 13 July 2008 Resolved
Make vessel available for internal structural examination by Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2008
Engineering › Steam Boiler (auxiliary/waste heat) › Fuel Oil Burner
Issued 7 April 2008 Resolved
Replace inoperable fuel circuit primary sensor panel on small package heating boiler.
Condition: Improper/Lack of Maintenance
Due 18 April 2008
Resolved 15 April 2008
Construction/Loadline › Hull › Girder
Issued 14 March 2007 Resolved
Replace 02 wasted long support beams in space behind engine room.
Action required: 705 - Other - as specified
Resolved 13 April 2007
Electrical › Lighting (service) › Outlet Box
Issued 22 February 2006 Resolved
There are open wiring splices located in the liquor storage locker and firehose station. Enclose splices in junction box.
Condition: Improper/Lack of Maintenance
Due 21 April 2006
Resolved 3 May 2006
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 22 February 2006 Resolved
Reattach/replace electric bilge pump to PVC overboard discharge line in void #3 (MSD tank space).
Condition: Improper/Lack of Maintenance
Due 21 April 2006
Resolved 3 May 2006
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 22 February 2006 Resolved
Replace cover to GFI outlet on aft bulkhead port side IWO MSD tank.
Condition: Improper/Lack of Maintenance
Due 21 April 2006
Resolved 3 May 2006
Engineering › Fuel Oil Service System › Filter
Issued 26 June 2005 Resolved
Determine nature of loss of propulsion and make proper repairs. Conduct sea trials with CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2005
Resolved 27 June 2005
Resolution: Conducted satisfactory sea trails.
Documentation › Logs/Records › Logbook (official)
Issued 23 May 2005 Resolved
Provide bound log book for the bridge log.
Condition: Improper/Lack of Maintenance
Due 27 May 2005
Resolved 2 June 2005
Resolution: Procured Same.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 23 May 2005 Resolved
Re-name/label child size lifejackets with current vessel name.
Condition: Improper/Lack of Maintenance
Due 27 May 2005
Resolved 2 June 2005
Resolution: Renamed same.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 23 May 2005 Resolved
Provide proper locking device for the overboard sewage line.
Condition: Improper/Lack of Maintenance
Due 27 May 2005
Resolved 2 June 2005
Resolution: Secured Same.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 May 2005 Resolved
Replace waterlight and three foot lanyard for the lifebuoys.
Condition: Improper/Lack of Maintenance
Due 27 May 2005
Resolved 2 June 2005
Resolution: Replaced Same With New.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 23 May 2005 Resolved
Crop and renew patch in the marine sanitation device piping system in the engine room.
Condition: Improper/Lack of Maintenance
Due 31 December 2005
Resolved 2 June 2005
Resolution: Temporarily Repaired Same, Will C/R Prior To Next Annual Insp.
Engineering › Bilge Water Management System › Hose
Issued 23 May 2005 Resolved
Provide suitable length hose for portable bilge pump.
Condition: Improper/Lack of Maintenance
Due 27 May 2005
Resolved 2 June 2005
Resolution: Lengthened Same.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 23 May 2005 Resolved
Required vessel to reduce the amount of water coming through the shaft packing gland.
Condition: Improper/Lack of Maintenance
Due 27 May 2005
Resolved 23 May 2005
Resolution: Vessel adjusted the packing to reduce the amount of water coming in to the vessel.
Communications › Visual Communication
Issued 12 April 2004 Resolved
Post donning instructions for all types of life jackets.
Due 3 May 2004
Resolved 13 April 2004
Electrical › Electrical Distribution System (service)
Issued 12 April 2004 Resolved
Correctly label all circuit breakers in panel box along aft e/r bulkhead. LEGACY COMPONENT DESC: Circuit Breaker
Due 3 May 2004
Resolved 13 April 2004
Resolution: Labeled box
Electrical › Lighting (service)
Issued 12 April 2004 Resolved
Replace missing & burned out overhead lights in e/r. LEGACY COMPONENT DESC: Lighting Fixture
Due 3 May 2004
Resolved 13 April 2004
Resolution: Replaced bulb.
Deck/Cargo › Cargo Stowage
Issued 12 April 2004 Resolved
Remove or secure ice box/floor freezer on main deck.
Due 3 May 2004
Resolved 13 April 2004
Resolution: Secured freezer
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 April 2003 Resolved
Post all pages of COI in area conspicuous to passengers.
Due 1 May 2003
Resolved 14 May 2003
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 11 April 2003 Resolved
Mount 7.9" bell outside in vicinity of operating station.
Due 1 May 2003
Resolved 14 May 2003
Documentation › Logs/Records
Issued 11 April 2003 Resolved
Provide copy of senior deckhand designation letter. Vessel must have a licensed mate aboard when carrying 150 passengers or more until corrected.
Due 1 May 2003
Resolved 10 February 2004
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 11 April 2003 Resolved
Provide 1 child-size life preserver. Vessel may not carry more than 24 children until corrected.
Due 1 May 2003
Resolved 11 April 2003
Navigation › Piloting/Steering › Magnetic Compass
Issued 11 April 2003 Resolved
Renew compass light.
Due 1 May 2003
Resolved 14 May 2003
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 April 2003 Resolved
Install electrical cover to small package boiler.
Due 1 May 2003
Resolved 14 May 2003
Engineering › Steam System (auxiliary) › Valve, Relief
Issued 11 April 2003 Resolved
Renew safety relief valve (rated no more than 30 PSI) to small package boiler. May not use boiler until corrected.
Due 1 May 2003
Resolved 14 May 2003
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 7 March 2003 Resolved
Install circuit breaker panel cover in e/r (converted to a CG-835 during annual inspection/11Apr03/Activity #2004217).
Due 1 May 2003
Resolved 10 February 2004
Resolution: Rcvd digital photograph this date depicting new panel cover installation.
Fire Fighting › Structural Fire Protection - General
Issued 25 April 2002 Resolved
Replace i-core dance floor with approved material. LEGACY COMPONENT DESC: Dance Floor
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2002
Resolved 11 February 2004
Resolution: Received fax from [name withheld] (Marine consultant) who indicated dance floor replaced with non-skid ceramic tile on 20Nov02.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 18 April 2002 Resolved
Replace 1 BII portable fire extinguisher (cracked gauge). LEGACY COMPONENT DESC: Pressure Gauge
Due 3 May 2002
Resolved 26 April 2002
Resolution: Observed new fire extinguisher.
Operations/Management › Drug and Alcohol Testing
Issued 18 April 2002 Resolved
Provide proof of supervisory training in regards to companies drug & alcohol program & U.S. Coast Guard regulations. LEGACY COMPONENT DESC: EAP Training Requirements
Due 3 May 2002
Resolved 31 May 2002
Resolution: Received fax indicating [name withheld] attended Supervisory Training.
Lifesaving › Visual Distress Signals (General) › Storage
Issued 18 April 2002 Resolved
Provide watertight container for distress signals. Container shall be brightly colored & marked in 1/2" letters, "Distress Signals."
Due 3 May 2002
Resolved 26 April 2002
Resolution: Observed proper storage.
Accommodation/Occupational Safety › Medical/First Aid
Issued 18 April 2002 Resolved
Provide first aid kit approved under 46CFR160.041 or a kit with equivalent contents & instructions. LEGACY COMPONENT DESC: Medicine Chest
Due 3 May 2002
Resolved 26 April 2002
Resolution: Observed satisfactory first aid kit.
Navigation › Piloting/Steering › Marine Charts
Issued 18 April 2002 Resolved
Provide current charts & navigation publications.
Due 3 May 2002
Resolved 26 April 2002
Resolution: Observed new charts, light list, coast pilot, tide tables and tidal currents.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 18 April 2002 Resolved
Remove improperly installed outlet on stbd side of operating station.
Due 3 May 2002
Resolved 26 April 2002
Resolution: Outlet removed.
Accommodation/Occupational Safety › Occupational Safety
Issued 18 April 2002 Resolved
Remove deadended wire in wheelhouse. LEGACY COMPONENT DESC: Wiring
Due 3 May 2002
Resolved 26 April 2002
Resolution: Wire removed.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 18 April 2002 Resolved
Install approved portable fire extinguisher brackets.
Due 3 May 2002
Resolved 26 April 2002
Resolution: Observed newly installed brackets throughout vessel.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 April 2002 Resolved
Make 2nd deck stbd floodlight watertight.
Due 3 May 2002
Resolved 26 April 2002
Resolution: Floodlight watertight.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 April 2002 Resolved
Remove romex cable from beneath wheelhouse. Must be at least no. 14 AWG or larger boat cable.
Due 3 May 2002
Resolved 26 April 2002
Resolution: Romex removed and proper wire installed.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 18 April 2002 Resolved
Remove power strips from wheelhouse, linen closet & engine room.
Due 3 May 2002
Resolved 26 April 2002
Resolution: Power strips removed.
Stability › Watertight Integrity
Issued 18 April 2002 Resolved
Make bulkhead penetrations watertight in all compartments.
Due 3 May 2002
Resolved 26 April 2002
Resolution: Penetrations plugged.
Accommodation/Occupational Safety › Occupational Safety
Issued 18 April 2002 Resolved
Secure drink service bottles in compartment #2. LEGACY COMPONENT DESC: Drink Service Bottles
Due 3 May 2002
Resolved 26 April 2002
Resolution: Bottles secured.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 April 2002 Resolved
Make proper wire connections above power distribution panel at bottom of engine room ladder.
Due 3 May 2002
Resolved 26 April 2002
Resolution: Pressure connector installed and taped.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 18 April 2002 Resolved
Remove extension chords from freezers and provide suitable recepticle.
Due 3 May 2002
Resolved 26 April 2002
Resolution: Chord removed and plugged into closer recepticle.
Communications › Alarms/Indicators › High Water Alarm
Issued 18 April 2002 Resolved
Permanently attach bilge high level alarm in lazarette.
Due 3 May 2002
Resolved 26 April 2002
Resolution: Alarm permanently attached.
Engineering › Bilge Water Management System
Issued 18 April 2002 Resolved
Prove proper operation of fixed bilge system.
Due 18 April 2002
Resolved 26 April 2002
Resolution: Observed sat operation of bilge system.
Fire Fighting › Combustible Materials
Issued 18 April 2002 Resolved
Prove main deck chairs meet UL1056 or 46CFR72.05-55. LEGACY COMPONENT DESC: Furniture/Furnishings
Due 10 May 2002
Resolved 30 July 2002
Resolution: Chair frames are steel welded.
Fire Fighting › Structural Fire Protection - General
Issued 18 April 2002 Resolved
Provide plans to NYCMI detailing modifications to main deck interior to include, but not limited to floor, bulkhead & overhead coverings, wall board, dance floor & window/frames. LEGACY COMPONENT DESC: Accommodation Space Protection
Due 27 May 2002
Resolved 14 June 2002
Electrical › Electrical Distribution System (service)
Issued 18 April 2002 Resolved
Provide electrical load analysis for 2nd deck entertainment fixtures to NYCMI. Current extension chords & power box not approved. Modified to include entire vessel.
Due 10 May 2002
Resolved 14 June 2002
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 18 April 2002 Resolved
Conduct satisfactory U/W man overboard drill in Coast Guard presence.
Due 3 May 2002
Resolved 26 April 2002
Resolution: Witnessed satisfactory recover of man overboard with 1 master, 3 deckhands and rescue platform (not required for this vessel).
Lifesaving
Issued 11 April 2001 Resolved
Replace expired aspirin in first aid kit.
Condition: Unknown
Due 11 April 2001
Resolved 11 April 2001
Engineering
Issued 11 April 2001 Resolved
Mark direction of operation of fuel shut off valve reach rods.
Condition: Unknown
Due 11 May 2001
Resolved 20 April 2001
Engineering
Issued 11 April 2001 Resolved
Replace fuel vent flame screens.
Condition: Unknown
Due 11 April 2001
Resolved 11 April 2001
Documentation
Issued 11 April 2001 Resolved
Make a passenger count available on shoreside for each voyage.
Condition: Unknown
Due 11 April 2001
Resolved 11 April 2001
Lifesaving
Issued 11 April 2001 Resolved
Conduct passenger safety orientations in accordance with 46 CFR 122.506.
Condition: Unknown
Due 11 April 2001
Resolved 11 April 2001
Lifesaving
Issued 11 April 2001 Resolved
Provide 3 red / 3 orange or 6 red flares that are current.
Condition: Unknown
Due 16 April 2001
Resolved 20 April 2001
Construction/Loadline
Issued 11 April 2001 Resolved
Blank off through-hull fittings above waterline starboard side of #2 and sewage compartments.
Condition: Unknown
Due 16 April 2001
Resolved 20 April 2001
Construction/Loadline
Issued 11 April 2001 Resolved
Repair bilge high level alarms for forepeak and #2 compartment.
Condition: Unknown
Due 16 April 2001
Resolved 20 April 2001
Construction/Loadline
Issued 11 April 2001 Resolved
Repair/ replace portable bilge pump.
Condition: Unknown
Due 11 April 2001
Resolved 11 April 2001
Construction/Loadline
Issued 11 April 2001 Resolved
Make bilge alarms audible.
Condition: Unknown
Due 11 April 2001
Resolved 11 April 2001
Construction/Loadline
Issued 26 February 2001 Resolved
Properly install either keel coolers valves or make integral to hull IAW 46CFR182.422.
Condition: Unknown
Due 27 February 2001
Resolved 27 February 2001
Construction/Loadline
Issued 26 February 2001 Resolved
C/R deteriorated steel IWO entrance to upper deck aft.
Condition: Unknown
Due 26 February 2001
Resolved 26 February 2001
Electrical
Issued 26 February 2001 Resolved
Mount wires properly in to breaker boxes IWO latter at entrance to engine room and also breaker box IWO latter for emergency escape aft port side.
Condition: Unknown
Due 26 February 2001
Resolved 26 February 2001
Navigation
Issued 26 February 2001 Resolved
Install proper safety glass into bridge windows and properly seal area.
Condition: Unknown
Due 26 February 2001
Resolved 26 February 2001
Electrical
Issued 26 February 2001 Resolved
Replace light fixtures on upper deck IWO stack port side.
Condition: Unknown
Due 26 February 2001
Resolved 26 February 2001
Construction/Loadline
Issued 26 February 2001 Resolved
Attach bilge alarms in aft steering space and fwd storage space
Condition: Unknown
Due 26 February 2001
Resolved 26 February 2001
Electrical
Issued 26 February 2001 Resolved
Remove deadened wire IWO sewage tank and overhead in tank space.
Condition: Unknown
Due 26 February 2001
Resolved 26 February 2001
Electrical
Issued 26 February 2001 Resolved
Properly support wires for vent in sewage space
Condition: Unknown
Due 26 February 2001
Resolved 26 February 2001
Construction/Loadline
Issued 26 February 2001 Resolved
C/R rub rail on starboard side as marked, also V/W top weld @ start of replacement plate to amidships.
Condition: Unknown
Due 26 February 2001
Resolved 26 February 2001
Navigation
Issued 22 March 2000 Resolved
PROVIDE CURRENT COPIES OF LIGHT LIST, COAST PILOT, AND CHARTS ON BOARD VESSEL.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Engineering
Issued 22 March 2000 Resolved
PROPERLY LABLE FUEL SHUT-OFF.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Lifesaving
Issued 22 March 2000 Resolved
PROPERLY LABLE PFD'S WITH VESSELS NAME.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Lifesaving
Issued 22 March 2000 Resolved
PROPERLY LABLE LOCATION AND NUMBER OF PFD'S.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Construction/Loadline
Issued 22 March 2000 Resolved
PROVE PROPER OPERATION OF MSD OVERBOARD VALVE.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Construction/Loadline
Issued 18 February 1999 Resolved
CROP AND RENEW STEEL IN VOID #2 PORTSIDE, AFT MOST BAY #5 IWO SIDESHELL #1 FROM THE OVERHEAD.
Condition: Unknown
Due 18 February 1999
Resolved 18 February 1999
Electrical
Issued 18 February 1999 Resolved
REPLACE MISSING FUSES IN THE 32 VOLTS ELECTRICAL PANEL AND LIGHT GLOBES IN THE ENGINE ROOM.
Condition: Unknown
Due 18 February 1999
Resolved 18 February 1999
Engineering
Issued 18 February 1999 Resolved
PROVIDE VESSELS PROPELLER TO A CG MARINE INSPECTOR FOR INSPECTION.
Condition: Unknown
Due 18 February 1999
Resolved 18 February 1999
Engineering
Issued 18 February 1999 Resolved
REPLACE BEARINGS BOTH TOP AND BOTTOM OF THE RUDDER.
Condition: Unknown
Due 18 February 1999
Resolved 18 February 1999
Accommodation/Occupational Safety
Issued 18 February 1999 Resolved
REPLACE 1 STARBOARD AND 2 PORTSIDE BROKEN WINDOWS IN THE ACCOM SPACE PRIOR TO EMBARKING OF PASSENGERS.
Condition: Unknown
Due 18 February 1999
Resolved 18 February 1999
Fire Fighting
Issued 18 February 1999 Resolved
PROVIDE TO A CG MARINE INSPECTOR BOTH THE FIREPUMP 2" AND GENERATOR 1.5" BUTTERFLY VALVES. UPON COMPLETION OF BEING RE-WORKED.
Condition: Unknown
Due 18 February 1999
Resolved 18 February 1999
Construction/Loadline
Issued 18 February 1999 Resolved
CROP AND RENEW STEEL IN VOID #3 PORTSIDE IWO #3 CROSS BEAM.
Condition: Unknown
Due 18 February 1999
Resolved 18 February 1999
Lifesaving
Issued 3 April 1998 Resolved
POST EMERGENCY INSTRUCTIONS IN CONSPICUOUS PLACE
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Lifesaving
Issued 3 April 1998 Resolved
POST LIFE JACKET DONNING INSTRUCTIONS IN ACCOM SPACES
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Documentation
Issued 3 April 1998 Resolved
PROVIDE A WASTE MANAGEMENT PLAN FOR CREW MEMBERS
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Navigation
Issued 3 April 1998 Resolved
PROVIDE ANCHOR BALL DAY SHAPES
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Lifesaving
Issued 3 April 1998 Resolved
PROVIDE A COMPLETE AND APPROVED FIRST AID KIT
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Lifesaving
Issued 3 April 1998 Resolved
REMOVE ALL FLAMMABLE LIQUIDS FROM BELOW DECK COMPARTMENTS
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Electrical
Issued 3 April 1998 Resolved
PROVIDE BACK PANEL FOR ELECTRICAL SWITCHBOARD
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Electrical
Issued 3 April 1998 Resolved
PROPERLY SECURE BATTERY BOX TO PREVENT MOVEMENT
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Lifesaving
Issued 3 April 1998 Resolved
PROVIDE SEPERATE OR DISTINCT STOWAGE OF CHILDREN'S PFD
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Lifesaving
Issued 3 April 1998 Resolved
PROVE PROPER OPERATION OF PUBLIC ADDRESS SYSTEM.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Construction/Loadline
Issued 13 December 1994 Resolved
RENEW APPROX. 2 SQ. FT. OF SIDEHELL PLATING, MIDSHIPS PORT SIDE. THIN PLATE DUE TO EXCESSIVE CONDENSATION IN E/R VENT.
Condition: Unknown
Due 13 December 1994
Resolved 13 December 1994
Navigation
Issued 13 December 1994 Resolved
RENEW WORN UPPER RUDDER BEARING.
Condition: Unknown
Due 13 December 1994
Resolved 13 December 1994
Engineering
Issued 22 June 1994 Resolved
PEEP SIGHT GLASS BROKE NEEDS REPLACEMENT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 June 1994
Resolved 22 June 1994
Engineering
Issued 22 June 1994 Resolved
OIL LINE TO AIR COMPRESSOR ON ENGINE REQUIRES CHAFE MATERIAL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 September 1994
Resolved 29 June 1994
Fire Fighting
Issued 22 June 1994 Resolved
SPRINKLER SYSTEM HEAD NOT FUNCTIONING CORRECTLY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 September 1994
Resolved 29 June 1994
Lifesaving
Issued 22 June 1994 Resolved
VESSEL NEEDS 8 MORE ADULT PFD'S AS REQUIRED BY COI._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 June 1994
Resolved 29 June 1994
Electrical
Issued 20 May 1993 Resolved
REPAIR SHORE TIE CABLE SHORE PULLED FROM PLUG END.
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Electrical
Issued 20 May 1993 Resolved
MAKE WATER TIGHT THE WIRING PENETRATION TO STBD DECK LIGHT.
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Accommodation/Occupational Safety
Issued 20 May 1993 Resolved
PROVIDE WATER TO WASH BASINS IN BOTH HEADS.
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Fire Fighting
Issued 20 May 1993 Resolved
REPAIR/REPLACE LEAKING FIRE HOSE NOZZLE.
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Lifesaving
Issued 20 May 1993 Resolved
PROVIDE SIXTEEN(16) ADULT LIFE PRESERVERS.
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Lifesaving
Issued 20 May 1993 Resolved
PROVIDE TWO(02) CHILD PFD'S.
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Fire Fighting
Issued 20 May 1993 Resolved
PROPERLY MARK FIRE STATION.
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Lifesaving
Issued 20 May 1993 Resolved
PROVIDE NEW RING BOUY WITH LIGHT AND LINE.
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Lifesaving
Issued 29 May 1992 Resolved
PROVIDE 11 ADDITIONAL TYPE I LIFEJACKETS PRIOR TO CARRYING GREATER THAN 252PASSENGERS.
Condition: Unknown
Due 29 May 1992
Resolved 29 May 1992
Engineering
Issued 21 May 1990 Resolved
CLEAN ENGINE ROOM BILGES OF OIL AND WATER.
Condition: Unknown
Due 21 May 1990
Resolved 21 May 1990
Lifesaving
Issued 21 May 1990 Resolved
PROVIDE NINE (09) ADULT LIFE RESERVERS, VESSEL LIMITED TO TWO-HUNDRED AND FIFTY-FOUR (254) PERSONS UNTIL LIFE PRESERVERS ARE PROVIDED.
Condition: Unknown
Due 21 May 1990
Resolved 21 May 1990

Casualty record · 2

26 June 2005Routine · role: Involved in a Marine Casualty · activity 2478402
12 July 2008Routine · role: Involved in a Marine Casualty · activity 3269724
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

HALF MOON (2005–2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.