← All vessels
AVALON
Passenger (Inspected) · Passenger Ship class · Built 1960s · USCG Northeast District (CGD-NE) · Other hulls named AVALON
AVALON is a 1963 passenger vessel (inspected). The Coast Guard has recorded 84 inspections since 1984, most recently in January 2026, along with 131 deficiencies, 1 operational control and 2 casualty investigations between 2005 and 2008.
Records from 1984 to 2026. Most recent: inspection, 21 January 2026.
- Built
- 1963
- Last inspected
- 21 January 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 131 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2005–2008
Identity
292461
WDD7440
44529
Flag
UNKNOWN
367186430
Maury page id
psix-44529
Inspections, by type
…with no type recorded7
Years with a record
38 calendar years (1984–2026)
The 84 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)64.8 ft × 26.9 ft × 7.6 ft
Registered tonnagegross 80 / net 64
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORP · WARREN, RI, UNITED STATES · built 1963
Hull materialSteel
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it80 - Regulatory (Subpart C or D), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDD7440MMSI 367186430 · active · compulsorily equipped · granted 22 February 2017, expires 10 May 2027
WCV4791MMSI 366993040 · expired · voluntarily equipped · granted 22 November 1995, cancelled 28 January 2006
WCQ6430MMSI not assigned · expired · voluntarily equipped · granted 5 April 1995, cancelled 11 June 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 84
21 January 2026
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8299257
13 November 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8267822
27 January 2025
Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8070113
30 January 2024
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7853819
22 January 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7852726
1 November 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7818785
30 May 2023
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7700136
20 January 2023
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7622717
15 October 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7336971
8 October 2021
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7503757
21 October 2020
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7082264
24 October 2019
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6840861
11 October 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6836254
29 October 2018
MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6570436
4 October 2018
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6554827
5 September 2017
Internal Structural Exam · Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6260724
10 February 2017
MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6085829
1 February 2017
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6081181
27 October 2015
MTSA Verification · Administrative Inspection · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5750711
16 July 2015
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5187030
12 May 2014
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4856563
3 May 2012
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4300914
19 January 2012
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4227743
3 February 2009
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3411637
13 July 2008
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3266121
12 July 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3269724
7 April 2008
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3179238
14 March 2007
COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2889059
22 February 2006
MARPOL Annex V Examination · Annual Inspection · Plan Review (Other than "T")
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2591165
26 June 2005
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2403483
26 June 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2478402
23 May 2005
Annual Inspection · MTSA Verification · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2365651
22 February 2005
Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2296784
12 April 2004
MARPOL Annex V Examination · Deficiency Check · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2042140
11 April 2003
MARPOL Annex V Examination · Deficiency Check · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2004217
7 March 2003
Hull Examination · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1755335
14 June 2002
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1675042
25 April 2002
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1609246
18 April 2002
Deficiency Check · MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1609199
24 July 2001
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1069624
11 April 2001
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1445797
26 February 2001
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1418849
22 March 2000
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1435005
10 May 1999
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 794957
2 April 1999
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1365126
26 March 1999
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1114589
8 March 1999
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1369069
18 February 1999
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1410016
17 April 1998
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1122796
3 April 1998
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1125692
13 June 1997
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1110875
22 January 1997
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1106885
19 September 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1457384
17 April 1996
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1079943
15 June 1995
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 880337
12 June 1995
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 878945
13 December 1994
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1146567
22 June 1994
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1134422
20 May 1993
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 831977
16 March 1993
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1147683
15 June 1992
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 943259
29 May 1992
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 958686
21 October 1991
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 940754
16 September 1991
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1247022
6 September 1991
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1247174
5 September 1991
Drydock Extension
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1251313
21 May 1991
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1229367
1 June 1990
Damage Survey
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 922903
21 May 1990
COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 931190
4 April 1990
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1215841
22 January 1990
Examination of Repairs
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 900149
23 May 1989
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1194796
6 October 1988
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1200270
22 September 1988
Drydock Extension
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1352503
17 June 1988
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1203047
30 June 1987
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1317866
26 May 1987
COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1334137
24 March 1987
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1017205
23 March 1987
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1017317
23 June 1986
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1303208
22 October 1985
Credit Drydock
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1299766
16 May 1985
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 979967
30 October 1984
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 975475
21 May 1984
COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1324854
Deficiency record · 131
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 January 2025
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules...
STBD navigation light was extinguished.
46 CFR 183.420
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 January 2024
Resolved
"Your vessel must undergo an annual inspection w/in 3 months before or after each anniversary date." Vessel missed its 3rd annual inspection for COI. The COI is now invalidated and the vessel will need to submit an application for a new COI.
46 CFR 176.500(b)(1)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2023
Resolved
Descale framing underneath MSD tank, as discussed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2023
Resolved
Descale the framing aft of the MSD tank as discussed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 1 November 2023
Resolved
Starboard and Port side engine frame cracked, crop and renew as marked.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2023
Resolved
Descale the bilge in way of shaft as marked.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2023
Resolved
Descale Starboard side forward to bulkhead in the engine room as marked.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2023
Resolved
Descale in the steering flat as marked in all four bays.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2023
Resolved
Locate and descale the fixed ballast in accordance to with the Stability Letter.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2023
Resolved
Demonstrate function the bilge system.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 1 November 2023
Resolved
Demonstrate function of all fire dampeners in the engine room.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2023
Resolved
Provide description of any modification that have been made to the vessel since the Stability Letter was issued in 1963.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2023
Resolved
The deck plating in the engine room near the port side fuel tank has to be cropped and renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 January 2023
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments, under all practical conditions.
The vessels bilge system was not operating.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 January 2023
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in the bilges.
The floats for the high level alarms were not in serviceable condition.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 January 2023
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections.
The distribution panels on the bridge and in the engine room were not totally enclosed.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 20 January 2023
Resolved
Each officer employed on any vessel subject to this sub chapter must have his or her license or merchant mariner credential on board and available for examination at all times.
Crew was not present at Annual inspection
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 January 2023
Resolved
The owner, charterer, master or managing owner shall instruct each crew member as to the duties that the crew member is expected to perform in an emergency.
MIs were not able to witness crew competency during inspection because no crew was in attendance. MIs must witness adequate drills, training records, and use of bridge equipment during follow up inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 October 2018
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. You must contact the cognizant OCMI to schedule an inspection at a time and place which he or she approves. No written application is required. Vessel has been operating outside of window for 2nd Annual, and is now due for a third Annual inspection.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 September 2017
Resolved
Complete satisfactory credit drydock and internal structural exams prior to carrying passengers.
Lifesaving › Lifebuoys › Approval
Issued 10 February 2017
Resolved
Provide Q-spec for current ring buoys on board.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 February 2017
Resolved
Vessel must complete 1st annual inspection, inspection is overdue.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 3 February 2009
Resolved
Provide outlet cover for exposed outlet, 02 deck, as indicated.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 February 2009
Resolved
Properly support wiring for air conditioner unit in lazarette.
Construction/Loadline › Hull › Bottom Plating
Issued 13 July 2008
Resolved
Conduct dive survey of vessel hull and appurtenances and provide report of the same.
Construction/Loadline › Hull › Bottom Plating
Issued 13 July 2008
Resolved
Make vessel available for internal structural examination by Marine Inspector.
Engineering › Steam Boiler (auxiliary/waste heat) › Fuel Oil Burner
Issued 7 April 2008
Resolved
Replace inoperable fuel circuit primary sensor panel on small package heating boiler.
Construction/Loadline › Hull › Girder
Issued 14 March 2007
Resolved
Replace 02 wasted long support beams in space behind engine room.
Electrical › Lighting (service) › Outlet Box
Issued 22 February 2006
Resolved
There are open wiring splices located in the liquor storage locker and firehose station. Enclose splices in junction box.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 22 February 2006
Resolved
Reattach/replace electric bilge pump to PVC overboard discharge line in void #3 (MSD tank space).
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 22 February 2006
Resolved
Replace cover to GFI outlet on aft bulkhead port side IWO MSD tank.
Engineering › Fuel Oil Service System › Filter
Issued 26 June 2005
Resolved
Determine nature of loss of propulsion and make proper repairs. Conduct sea trials with CG Marine Inspector.
Documentation › Logs/Records › Logbook (official)
Issued 23 May 2005
Resolved
Provide bound log book for the bridge log.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 23 May 2005
Resolved
Re-name/label child size lifejackets with current vessel name.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 23 May 2005
Resolved
Provide proper locking device for the overboard sewage line.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 May 2005
Resolved
Replace waterlight and three foot lanyard for the lifebuoys.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 23 May 2005
Resolved
Crop and renew patch in the marine sanitation device piping system in the engine room.
Engineering › Bilge Water Management System › Hose
Issued 23 May 2005
Resolved
Provide suitable length hose for portable bilge pump.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 23 May 2005
Resolved
Required vessel to reduce the amount of water coming through the shaft packing gland.
Communications › Visual Communication
Issued 12 April 2004
Resolved
Post donning instructions for all types of life jackets.
Electrical › Electrical Distribution System (service)
Issued 12 April 2004
Resolved
Correctly label all circuit breakers in panel box along aft e/r bulkhead. LEGACY COMPONENT DESC: Circuit Breaker
Electrical › Lighting (service)
Issued 12 April 2004
Resolved
Replace missing & burned out overhead lights in e/r. LEGACY COMPONENT DESC: Lighting Fixture
Deck/Cargo › Cargo Stowage
Issued 12 April 2004
Resolved
Remove or secure ice box/floor freezer on main deck.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 April 2003
Resolved
Post all pages of COI in area conspicuous to passengers.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 11 April 2003
Resolved
Mount 7.9" bell outside in vicinity of operating station.
Documentation › Logs/Records
Issued 11 April 2003
Resolved
Provide copy of senior deckhand designation letter. Vessel must have a licensed mate aboard when carrying 150 passengers or more until corrected.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 11 April 2003
Resolved
Provide 1 child-size life preserver. Vessel may not carry more than 24 children until corrected.
Navigation › Piloting/Steering › Magnetic Compass
Issued 11 April 2003
Resolved
Renew compass light.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 April 2003
Resolved
Install electrical cover to small package boiler.
Engineering › Steam System (auxiliary) › Valve, Relief
Issued 11 April 2003
Resolved
Renew safety relief valve (rated no more than 30 PSI) to small package boiler. May not use boiler until corrected.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 7 March 2003
Resolved
Install circuit breaker panel cover in e/r (converted to a CG-835 during annual inspection/11Apr03/Activity #2004217).
Fire Fighting › Structural Fire Protection - General
Issued 25 April 2002
Resolved
Replace i-core dance floor with approved material. LEGACY COMPONENT DESC: Dance Floor
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 18 April 2002
Resolved
Replace 1 BII portable fire extinguisher (cracked gauge). LEGACY COMPONENT DESC: Pressure Gauge
Operations/Management › Drug and Alcohol Testing
Issued 18 April 2002
Resolved
Provide proof of supervisory training in regards to companies drug & alcohol program & U.S. Coast Guard regulations. LEGACY COMPONENT DESC: EAP Training Requirements
Lifesaving › Visual Distress Signals (General) › Storage
Issued 18 April 2002
Resolved
Provide watertight container for distress signals. Container shall be brightly colored & marked in 1/2" letters, "Distress Signals."
Accommodation/Occupational Safety › Medical/First Aid
Issued 18 April 2002
Resolved
Provide first aid kit approved under 46CFR160.041 or a kit with equivalent contents & instructions. LEGACY COMPONENT DESC: Medicine Chest
Navigation › Piloting/Steering › Marine Charts
Issued 18 April 2002
Resolved
Provide current charts & navigation publications.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 18 April 2002
Resolved
Remove improperly installed outlet on stbd side of operating station.
Accommodation/Occupational Safety › Occupational Safety
Issued 18 April 2002
Resolved
Remove deadended wire in wheelhouse. LEGACY COMPONENT DESC: Wiring
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 18 April 2002
Resolved
Install approved portable fire extinguisher brackets.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 April 2002
Resolved
Make 2nd deck stbd floodlight watertight.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 April 2002
Resolved
Remove romex cable from beneath wheelhouse. Must be at least no. 14 AWG or larger boat cable.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 18 April 2002
Resolved
Remove power strips from wheelhouse, linen closet & engine room.
Stability › Watertight Integrity
Issued 18 April 2002
Resolved
Make bulkhead penetrations watertight in all compartments.
Accommodation/Occupational Safety › Occupational Safety
Issued 18 April 2002
Resolved
Secure drink service bottles in compartment #2. LEGACY COMPONENT DESC: Drink Service Bottles
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 April 2002
Resolved
Make proper wire connections above power distribution panel at bottom of engine room ladder.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 18 April 2002
Resolved
Remove extension chords from freezers and provide suitable recepticle.
Communications › Alarms/Indicators › High Water Alarm
Issued 18 April 2002
Resolved
Permanently attach bilge high level alarm in lazarette.
Engineering › Bilge Water Management System
Issued 18 April 2002
Resolved
Prove proper operation of fixed bilge system.
Fire Fighting › Combustible Materials
Issued 18 April 2002
Resolved
Prove main deck chairs meet UL1056 or 46CFR72.05-55. LEGACY COMPONENT DESC: Furniture/Furnishings
Fire Fighting › Structural Fire Protection - General
Issued 18 April 2002
Resolved
Provide plans to NYCMI detailing modifications to main deck interior to include, but not limited to floor, bulkhead & overhead coverings, wall board, dance floor & window/frames. LEGACY COMPONENT DESC: Accommodation Space Protection
Electrical › Electrical Distribution System (service)
Issued 18 April 2002
Resolved
Provide electrical load analysis for 2nd deck entertainment fixtures to NYCMI. Current extension chords & power box not approved. Modified to include entire vessel.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 18 April 2002
Resolved
Conduct satisfactory U/W man overboard drill in Coast Guard presence.
Lifesaving
Issued 11 April 2001
Resolved
Replace expired aspirin in first aid kit.
Engineering
Issued 11 April 2001
Resolved
Mark direction of operation of fuel shut off valve reach rods.
Engineering
Issued 11 April 2001
Resolved
Replace fuel vent flame screens.
Documentation
Issued 11 April 2001
Resolved
Make a passenger count available on shoreside for each voyage.
Lifesaving
Issued 11 April 2001
Resolved
Conduct passenger safety orientations in accordance with 46 CFR 122.506.
Lifesaving
Issued 11 April 2001
Resolved
Provide 3 red / 3 orange or 6 red flares that are current.
Construction/Loadline
Issued 11 April 2001
Resolved
Blank off through-hull fittings above waterline starboard side of #2 and sewage compartments.
Construction/Loadline
Issued 11 April 2001
Resolved
Repair bilge high level alarms for forepeak and #2 compartment.
Construction/Loadline
Issued 11 April 2001
Resolved
Repair/ replace portable bilge pump.
Construction/Loadline
Issued 11 April 2001
Resolved
Make bilge alarms audible.
Construction/Loadline
Issued 26 February 2001
Resolved
Properly install either keel coolers valves or make integral to hull IAW 46CFR182.422.
Construction/Loadline
Issued 26 February 2001
Resolved
C/R deteriorated steel IWO entrance to upper deck aft.
Electrical
Issued 26 February 2001
Resolved
Mount wires properly in to breaker boxes IWO latter at entrance to engine room and also breaker box IWO latter for emergency escape aft port side.
Navigation
Issued 26 February 2001
Resolved
Install proper safety glass into bridge windows and properly seal area.
Electrical
Issued 26 February 2001
Resolved
Replace light fixtures on upper deck IWO stack port side.
Construction/Loadline
Issued 26 February 2001
Resolved
Attach bilge alarms in aft steering space and fwd storage space
Electrical
Issued 26 February 2001
Resolved
Remove deadened wire IWO sewage tank and overhead in tank space.
Electrical
Issued 26 February 2001
Resolved
Properly support wires for vent in sewage space
Construction/Loadline
Issued 26 February 2001
Resolved
C/R rub rail on starboard side as marked, also V/W top weld @ start of replacement plate to amidships.
Navigation
Issued 22 March 2000
Resolved
PROVIDE CURRENT COPIES OF LIGHT LIST, COAST PILOT, AND CHARTS ON BOARD VESSEL.
Engineering
Issued 22 March 2000
Resolved
PROPERLY LABLE FUEL SHUT-OFF.
Lifesaving
Issued 22 March 2000
Resolved
PROPERLY LABLE PFD'S WITH VESSELS NAME.
Lifesaving
Issued 22 March 2000
Resolved
PROPERLY LABLE LOCATION AND NUMBER OF PFD'S.
Construction/Loadline
Issued 22 March 2000
Resolved
PROVE PROPER OPERATION OF MSD OVERBOARD VALVE.
Construction/Loadline
Issued 18 February 1999
Resolved
CROP AND RENEW STEEL IN VOID #2 PORTSIDE, AFT MOST BAY #5 IWO SIDESHELL #1 FROM THE OVERHEAD.
Electrical
Issued 18 February 1999
Resolved
REPLACE MISSING FUSES IN THE 32 VOLTS ELECTRICAL PANEL AND LIGHT GLOBES IN THE ENGINE ROOM.
Engineering
Issued 18 February 1999
Resolved
PROVIDE VESSELS PROPELLER TO A CG MARINE INSPECTOR FOR INSPECTION.
Engineering
Issued 18 February 1999
Resolved
REPLACE BEARINGS BOTH TOP AND BOTTOM OF THE RUDDER.
Accommodation/Occupational Safety
Issued 18 February 1999
Resolved
REPLACE 1 STARBOARD AND 2 PORTSIDE BROKEN WINDOWS IN THE ACCOM SPACE PRIOR TO EMBARKING OF PASSENGERS.
Fire Fighting
Issued 18 February 1999
Resolved
PROVIDE TO A CG MARINE INSPECTOR BOTH THE FIREPUMP 2" AND GENERATOR 1.5" BUTTERFLY VALVES. UPON COMPLETION OF BEING RE-WORKED.
Construction/Loadline
Issued 18 February 1999
Resolved
CROP AND RENEW STEEL IN VOID #3 PORTSIDE IWO #3 CROSS BEAM.
Lifesaving
Issued 3 April 1998
Resolved
POST EMERGENCY INSTRUCTIONS IN CONSPICUOUS PLACE
Lifesaving
Issued 3 April 1998
Resolved
POST LIFE JACKET DONNING INSTRUCTIONS IN ACCOM SPACES
Documentation
Issued 3 April 1998
Resolved
PROVIDE A WASTE MANAGEMENT PLAN FOR CREW MEMBERS
Navigation
Issued 3 April 1998
Resolved
PROVIDE ANCHOR BALL DAY SHAPES
Lifesaving
Issued 3 April 1998
Resolved
PROVIDE A COMPLETE AND APPROVED FIRST AID KIT
Lifesaving
Issued 3 April 1998
Resolved
REMOVE ALL FLAMMABLE LIQUIDS FROM BELOW DECK COMPARTMENTS
Electrical
Issued 3 April 1998
Resolved
PROVIDE BACK PANEL FOR ELECTRICAL SWITCHBOARD
Electrical
Issued 3 April 1998
Resolved
PROPERLY SECURE BATTERY BOX TO PREVENT MOVEMENT
Lifesaving
Issued 3 April 1998
Resolved
PROVIDE SEPERATE OR DISTINCT STOWAGE OF CHILDREN'S PFD
Lifesaving
Issued 3 April 1998
Resolved
PROVE PROPER OPERATION OF PUBLIC ADDRESS SYSTEM.
Construction/Loadline
Issued 13 December 1994
Resolved
RENEW APPROX. 2 SQ. FT. OF SIDEHELL PLATING, MIDSHIPS PORT SIDE. THIN PLATE DUE TO EXCESSIVE CONDENSATION IN E/R VENT.
Navigation
Issued 13 December 1994
Resolved
RENEW WORN UPPER RUDDER BEARING.
Engineering
Issued 22 June 1994
Resolved
PEEP SIGHT GLASS BROKE NEEDS REPLACEMENT._x001C_ _x001C_ _x001C_ _x001C_
Engineering
Issued 22 June 1994
Resolved
OIL LINE TO AIR COMPRESSOR ON ENGINE REQUIRES CHAFE MATERIAL._x001C_ _x001C_ _x001C_ _x001C_
Fire Fighting
Issued 22 June 1994
Resolved
SPRINKLER SYSTEM HEAD NOT FUNCTIONING CORRECTLY._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 22 June 1994
Resolved
VESSEL NEEDS 8 MORE ADULT PFD'S AS REQUIRED BY COI._x001C_ _x001C_ _x001C_ _x001C_
Electrical
Issued 20 May 1993
Resolved
REPAIR SHORE TIE CABLE SHORE PULLED FROM PLUG END.
Electrical
Issued 20 May 1993
Resolved
MAKE WATER TIGHT THE WIRING PENETRATION TO STBD DECK LIGHT.
Accommodation/Occupational Safety
Issued 20 May 1993
Resolved
PROVIDE WATER TO WASH BASINS IN BOTH HEADS.
Fire Fighting
Issued 20 May 1993
Resolved
REPAIR/REPLACE LEAKING FIRE HOSE NOZZLE.
Lifesaving
Issued 20 May 1993
Resolved
PROVIDE SIXTEEN(16) ADULT LIFE PRESERVERS.
Lifesaving
Issued 20 May 1993
Resolved
PROVIDE TWO(02) CHILD PFD'S.
Fire Fighting
Issued 20 May 1993
Resolved
PROPERLY MARK FIRE STATION.
Lifesaving
Issued 20 May 1993
Resolved
PROVIDE NEW RING BOUY WITH LIGHT AND LINE.
Lifesaving
Issued 29 May 1992
Resolved
PROVIDE 11 ADDITIONAL TYPE I LIFEJACKETS PRIOR TO CARRYING GREATER THAN 252PASSENGERS.
Engineering
Issued 21 May 1990
Resolved
CLEAN ENGINE ROOM BILGES OF OIL AND WATER.
Lifesaving
Issued 21 May 1990
Resolved
PROVIDE NINE (09) ADULT LIFE RESERVERS, VESSEL LIMITED TO TWO-HUNDRED AND FIFTY-FOUR (254) PERSONS UNTIL LIFE PRESERVERS ARE PROVIDED.
Casualty record · 2
26 June 2005Routine · role: Involved in a Marine Casualty · activity 2478402
12 July 2008Routine · role: Involved in a Marine Casualty · activity 3269724
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
HALF MOON (2005–2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.