MSC DON GIOVANNI is a freight ship. The Coast Guard has recorded 23 inspections since 2020, most recently in May 2026, along with 14 deficiencies and 6 operational controls.
Records from 2020 to 2026. Most recent: operational control imposed, 25 May 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it53145 - Displacement, Metric Ton 29181 - Convention (Subpart B), Gross Ton 41583 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 23
25 May 2026Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8380312
6 April 2026Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8343464
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 December 2024Resolved
Main and emergency switchboards shall be so arranged as to give easy access as may be needed to apparatus and equipment, without danger to personnel. PSCO observer transfer line emergenct switch breaker on main switchboardhas been replaced. Size of new breaker does not match original housing and has exposed circuit and needs to be properly protected.
74SOLAS(04)II-1/45.2
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2024
Resolved 31 December 2024
Resolution: Sector VA received Class Report from DNV attesting to repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 December 2024Resolved
Every boiler essential for the safety of the ship and designed to contain water at a specified level shall be provided with at least two means for indication its water level, at least one of which shall be a direct reading gauge glass. PSCO observed a broken upper sight glass slowly leaking due to cracked glass from overtightening.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2025
Resolved 31 December 2024
Resolution: Sector VA received class report from DNV attesting to repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 July 2024Resolved
Means shall be provided whereby normal operation of propulsion machinery can be sustained or restored even though one of the essential auxiliaries become inoperative. Special consideration shall be given to malfuntioning of:
The sources of lubricating oil pressure.
PSCO were informed by master and crew the vessel's #02 lube oil purifier was inoperable due to a crack in the hood. Vessel has already informed company and class, and are awaiting for parts to be delivered. Parts should arrive while vessel is in Canada.
74 SOLAS (04) II-1/26.3.5
74SOLAS(04)II-1/26.3.5
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 September 2024
Resolution: Class report received attesting to repair.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 June 2024Resolved
Except for Ro Ro and vehicle spaces; cargo spaces on ships of 2000 gross tons and upwards shall be protected by a fixed carbon dioxide or inert gas fire-extinguishing system. PSCO observed CO2 lines on the cross deck between cargo holds 6 and 7 with substantial corrosion. Provide class report attesting to integrity of CO2 lines.
74 SOLAS (04) 11-2/10.7.1.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2024
Resolved 17 June 2024
Resolution: Subject lines surface treated, air blow test No6 and No7 cargo holds witnessed by class and tested sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 June 2024Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed multiple light fixtures broken and rewired in the BOSUN locker and bow thruster space.
74 SOLAS (04) 11-1/40.1.3
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2024
Resolved 17 June 2024
Resolution: Class report verified as repaired
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 June 2024Resolved
All electrical apparatus shall be so constructed and so installed as no to cause injury when handled or touches in the normal manner. PSCO observed several electrical switch covers missing in the fuel oil purifier room and on the ballast water system panels.
74 SOLAS (04) II-I 45.1.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2024
Resolved 30 July 2024
Resolution: Vessel crew provided Class report attesting to the repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 June 2024Resolved
Electrical installations shall be such that; the safety of passenger, crew and ship from electrical hazards will be ensured. PSCO observed cut and exposed wires found on the port side BOSUN locker. A modified extension cord was used to power cargo deck lighting through a modified electrical outlet on starboard side of the BOSUN locker.
74 SOLAS (04) II-I 40.1.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2024
Resolved 17 June 2024
Resolution: Class report verified as repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 June 2024Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. PSCO observed broken support brackets and heavily corroded / wasted support brackets on port and starboard cable runs between cargo holds two and three.
74 SOLAS (04) II-I/45.5.5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2024
Resolved 17 June 2024
Resolution: Class report verified as repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 11 June 2024Resolved
A main electric lighting system which shall provide illumination throughout those parts of the ship normally accessible to and used by passenger or crew shall be supplied from the main source of electrical power. PSCO observed multiple light fixtures not working in the forward section of the ship, including the BOSN hole and bow thruster room.
74 SOLAS (04) II-I/41.2.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2024
Resolved 30 July 2024
Resolution: Vessel crew provided Class report attesting to the repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 June 2024Resolved
The fire safety objectives of this chapter are to: prevent the occurrence of fire and explosion. PSCO observed hydraulic oil leak on bow thruster hydraulic pump. Crew fixed leak and cleaned up hydraulic oil.
74 SOLAS (04) II-2/2.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 June 2024
Resolved 11 June 2024
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 11 July 2023Resolved
To assist in casualty investigations, cargo ships, when engaged on international voyages, shall be fitted with a VDR which may be a simplified voyage data recorder (S-VDR) as follows...in the case of cargo ships of 3,000 gross tonnage and upwards constructed before 1 July 2002, at the first scheduled dry docking after 1 July 2006 but not later than 1 July 2009. PSCO was informed by Captain that SVDR was showing a fault and in need of repair by tech.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 11 August 2023
Resolved 23 August 2023
Resolution: Sector Jacksonville PSC went onboard, viewed the repaired S-VDR, and Class report attesting to the repair.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 11 July 2023Resolved
The machinery, boilers and other pressure vessels, associated piping... shall be so installed and protected as to reduce to a minimum any danger to persons on board... hot surfaces and other hazards. PSCO observed a leaking connection from the boiler's main steam line and blowing line.
Action required: 10 - Deficiency Rectified
Due 11 July 2023
Resolved 11 July 2023
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 9 March 2023Resolved
Any required system shall be capable of continuous operation at all times..Sample extraction smoke detection system is non operational.
74SOLAS(97)II/2 13-1.1.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 April 2023
Resolution: Received Class Survey attesting to repairs.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 8 October 2022Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT CONVENTION TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT PRESENTING AN UNREASONABLE THREAT OF HARM TO THE MARINE ENVIRONMENT. ONE ISO SOCKET AT BAY 170982 FOUND CRACKED. VESSEL SHALL NOT USE SOCKET UNTIL REPAIR IS MADE AND IS SATISFACTORY TO CLASS.
SOLAS(20) 1/11
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 October 2022
Resolution: Report received and attached