CALIFORNIA is a 1962 industrial vessel. The Coast Guard has recorded 52 inspections since 1987, most recently in April 2017, along with 93 deficiencies and 2 casualty investigations between 2004 and 2013.

Records from 1987 to 2017. Most recent: inspection, 18 April 2017.

Built
1962
Last inspected
18 April 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC6804
Flag
UNITED STATES
366036000, 366872310 (licence lapsed)
Maury page id
psix-44552

Inspections, by type

…with no type recorded11
Years with a record 25 calendar years (1987–2017)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it1109 - Regulatory (Subpart C or D), Gross Ton
1109 - Regulatory (Subpart C or D), Net Ton
570 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDC6804MMSI 366036000 · cancelled · compulsorily equipped · granted 8 August 2015, cancelled 12 February 2018
WO8151MMSI 366872310 · expired · compulsorily equipped · granted 5 July 1995, cancelled 7 January 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 7

Inspection history · 52

18 April 2017 Deficiency Check · Load Line/Change of Employment · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6127328
24 March 2016 Load Line/Change of Employment
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5841409
10 December 2015 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5779305
2 February 2011 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3937714
7 December 2010 Hull Examination · Internal Structural Exam · COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3906404
4 February 2009 Periodic Inspection · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 3403387
27 November 2007 Annual Inspection
Physical examination · Activities Europe · Activity 3105025
22 February 2007 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Activities Europe · Activity 2875520
27 October 2006 COI Inspection
Physical examination · Activities Europe · Activity 2809089
10 January 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2564105
21 November 2005 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2538199
18 November 2005 Annual Inspection
Physical examination · Activities Europe · Activity 2525981
7 April 2005 Internal Structural Exam · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2328426
14 December 2004 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2259358
17 November 2004 Periodic Inspection · MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2242569
11 October 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2309115
8 September 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2190142
13 August 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2165312
6 January 2004 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1973503
30 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979465
7 November 2002 Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1702102
28 February 2002 Hull Examination
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1483975
20 November 2001 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1076751
22 October 2001 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1443272
13 September 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 129084
31 October 2000 Examination of Repairs · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1366008
12 September 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 821926
12 November 1999 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 806484
20 October 1999 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1456744
18 December 1998 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1397056
21 October 1997 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1364421
12 August 1997 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1392748
17 July 1997 Hull Examination · Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1371917
11 October 1995 COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1181255
11 April 1994 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 857530
24 February 1994 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1164300
1 February 1994 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1163202
23 December 1992 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1140746
12 November 1992 Deficiency Check · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1140739
24 February 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 682686
10 February 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 348799
4 April 1991 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 920520
19 June 1990 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 920684
10 May 1990 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1235018
8 November 1989 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1214617
1 May 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1206452
18 April 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1038521
4 April 1989 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1349907
11 April 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1208716
2 March 1988 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1029186
25 February 1988 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1336001
9 April 1987 COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016223

Deficiency record · 93

Construction/Loadline › Penetrations › Gasket
Issued 7 December 2010 Resolved
Replace water tight door gaskets and adjust doors to make water tight in the following spaces: rag room, stbd stern store room, and port fwd room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2011
Electrical › Lighting (emergency) › Lighting Fixture
Issued 7 December 2010 Resolved
Install and or fix emergency lighting in several below deck spaces.
Due 13 February 2011
Resolved 2 February 2011
Documentation › Certificates/Documents › International Load Line Certificate
Issued 7 December 2010 Resolved
Provide valid loadline certificate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2011
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 7 December 2010 Resolved
Update fire control plan to show new location of life jacket stowage.
Due 13 February 2011
Resolved 2 February 2011
Construction/Loadline › Hull › Bottom Plating
Issued 4 February 2009 Resolved
Replace the following frames: Storage p/s compartment all 5 frames from aft, storage for deck department 4th and 7th frame from fwd. Received email from Master stating that CG-835 items 1-5 have been completed. Extended due date to correspond with the next annual inspection.
Due 30 January 2010
Resolved 2 February 2011
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 4 February 2009 Resolved
Repair hole in way of bilge near watertight door between the pump room and the storage room. Received email from Master stating that CG-835 items 1-5 have been completed. Extended due date to correspond with the next annual inspection.
Due 30 January 2010
Resolved 2 February 2011
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 4 February 2009 Resolved
Properly secure the heat exchanger for the thrust bearing. Received email from Master stating that CG-835 items 1-5 have been completed. Extended due date to correspond with the next annual inspection.
Due 30 January 2010
Resolved 2 February 2011
Fire Fighting › Portable CO2 Fire Extinguisher › Discharge Hose/Tube
Issued 4 February 2009 Resolved
Provide proper brackets for CO2 bottles so that the horn is properly secured. Received email from Master stating that CG-835 items 1-5 have been completed. Extended due date to correspond with the next annual inspection.
Due 30 January 2010
Resolved 2 February 2011
Engineering › Lubricating Oil Storage/Transfer System › Drain Tank
Issued 4 February 2009 Resolved
Provide a sight glass and remote gauge for the spring bearing holding box so that it can be properly secured. Received email from Master stating that CG-835 items 1-5 have been completed. Extended due date to correspond with the next annual inspection.
Due 30 January 2010
Resolved 2 February 2011
Documentation › Manuals/Policy Documentation › Under-keel Clearance Guidance
Issued 22 February 2007 Resolved
Provide letter from ABS and USCG stating deck plating and supports are no longer needed and do not have to be maintained.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2007
Resolution: Letter provided.
Construction/Loadline › Structures › Deck Plating
Issued 22 February 2007 Resolved
Replace all deck plating throughout vessel where exisiting deck is rotted. This includes but is not limitied to all pump rooms, storage lockers, passageways and engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2007
Construction/Loadline › Structures › Cofferdam
Issued 22 February 2007 Resolved
Make permanant repairs to all items identified on the list of steel repairs complied by ABS and USCG during the internal assesment.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2007
Resolution: Listed inspected and cleared.
Construction/Loadline › Penetrations › Pipe Flange
Issued 22 February 2007 Resolved
Remove all soft patches and doublers patches identified by USCG,
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2007
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 22 February 2007 Resolved
Remove paint from temporary paint locker and relocate to proper locker.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2007
Deck/Cargo › Ballast › Dedicated Clean Ballast Tanks
Issued 22 February 2007 Resolved
Remove all piping assosiated with fiberglass tanks and clean oil from bilge in fwd ballast void spaces.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 February 2007 Resolved
Provide to the Marine Safety Center three copies of plans for the supporting of all machinery currently mounted to the inner deck and frames (pumps, motors, pipe runs, storage selving, etc.), plans for the supporting a safe working walk way/ work area in all areas of the ship where the crew needs access to and plans providing access to the outer bottom. Provide the ABS approved plans detailing the
Due 31 May 2007
Resolved 6 June 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 February 2007 Resolved
Replace deck grating so that crew has a safe walkway and working area.
Due 31 May 2007
Resolved 6 June 2007
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 22 February 2007 Resolved
Clean vessels' engineering spaces removing steel scraps and othe rnot needed item. Secure needed items.
Due 31 May 2007
Resolved 6 June 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 30 October 2006 Resolved
Service all portable fire extinguishers.
Action required: 705 - Other - as specified
Resolved 31 October 2006
Engineering › Bilge Water Management System › Pump
Issued 30 October 2006 Resolved
Demonstrate proper operation of the bilge pump.
Action required: 705 - Other - as specified
Resolved 31 October 2006
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 30 October 2006 Resolved
Demonstrate the proper operation of the engine room dampers.
Action required: 705 - Other - as specified
Resolved 31 October 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 30 October 2006 Resolved
Install explosion proof globe in way of the battery charging station.
Action required: 705 - Other - as specified
Resolved 31 October 2006
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 30 October 2006 Resolved
Remove open (non-UL Marine) outlet in way of the battery charging station.
Action required: 705 - Other - as specified
Resolved 31 October 2006
Operations/Management › Other Criminal/Civil Violations › Failure to Terminate
Issued 27 October 2006 Resolved
The barge California operated commercially for four days without a valid Certificate of Inspection.
Action required: 705 - Other - as specified
Resolved 30 October 2006
Construction/Loadline › Hull › Longitudinal Frame
Issued 18 November 2005 Resolved
Replace 4' section of longitudal on STBD side forward of frame 44. Report cleared via E-mail dated 12/29/05. Item remains open until cleared by attending Marine Inspector. See Activity 2525981.
Due 22 October 2006
Resolved 30 October 2006
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 18 November 2005 Resolved
Replace fuel vent, spill box and horizontal pipe for fuel overfill on STBD side. Report cleared via E-mail dated 12/15/05. Item remains open until cleared by attending Marine Inspector. See Activity 2525981.
Due 22 October 2006
Resolved 30 October 2006
Electrical › Electrical Distribution System (service) › Cable
Issued 18 November 2005 Resolved
Remove dead end cable form old spot light above operational control room. Report cleared via E-mail dated 12/15/05. Item remains open until cleared by attending Marine Inspector. See Activity 2525981.
Due 22 October 2006
Resolved 30 October 2006
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 17 November 2004 Resolved
Make pressure vessel available for internal examination.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 December 2004
Resolved 7 December 2004
Resolution: Conducted internal inspection, all sat
Lifesaving › Hand Flares › Expired
Issued 17 November 2004 Resolved
Provide correct amount of hand flares for intended rout.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 December 2004
Resolved 7 December 2004
Resolution: Flares were onboard vsl. all sat
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 6 January 2004 Resolved
Perform hydrostatic test of oil transfer piping as required by 33 CFR 156.170 and provide copy of test results to [name withheld] DESC: Piping
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 February 2004
Resolved 17 February 2004
Resolution: Witnessed satisfactory hydro test of f/o transfer piping.
Operations/Management › Pollution
Issued 6 January 2004 Resolved
Submit Shipboard Oil Pollution Emergency Plan (SOPEP) to USCG for approval and provide approval letters to [name withheld]
Due 6 February 2004
Resolved 7 January 2004
Engineering › Bilge Water Management System
Issued 6 January 2004 Resolved
Crop and renew wasted section of main bilge suction piping in dredge pit. LEGACY COMPONENT DESC: Piping
Due 6 February 2004
Resolved 17 February 2004
Resolution: Bilge piping section was cropped and renewed.
Electrical › Electrical Distribution System (service)
Issued 6 January 2004 Resolved
Install blank in Lighting Panel #3, circuit #20. LEGACY COMPONENT DESC: Panelboard
Due 6 February 2004
Resolved 7 January 2004
Personnel › Manning/Qualifications
Issued 6 January 2004 Resolved
Vessel manning level not IAW conditions as stated on USCG Certificate of Inspection (COI) while operating in a manned condition. No certified lifeboatman on board. LEGACY COMPONENT DESC: Minimum Safe Manning
Action required: 705 - Other - as specified
Due 7 January 2004
Resolved 7 January 2004
Documentation › Certificates/Documents
Issued 7 November 2002 Resolved
Make application for and provide for inspection a current Certificate of Financial Responsibility. LEGACY COMPONENT DESC: Certificate of Financial Responsibility
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 November 2002
Resolved 7 November 2002
Resolution: COFR was applied for and approved this date.
Accommodation/Occupational Safety
Issued 22 October 2001 Resolved
REPLACE/REPAIR TYPE II MSD VENT PIPE
Condition: Unknown
Due 22 October 2001
Resolved 21 November 2001
Resolution: Received fax stating repair conducted (See MI01033980 deficiency report)
Engineering
Issued 22 October 2001 Resolved
REPLACE/REPAIR #7 STBD FUEL OIL VENT CONTAINMENT. ITEM IS WASTED.
Condition: Unknown
Due 22 October 2001
Resolved 22 October 2001
Navigation
Issued 20 October 1999 Resolved
Prove proper operation of the installed radar.
Condition: Unknown
Due 20 October 1999
Resolved 20 October 1999
Construction/Loadline
Issued 21 October 1997 Resolved
MAKE PERMANENT REPAIRS OR RENEW LEVER ROOM DOORS TO MAKE WEATHER TIGHT.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Electrical
Issued 21 October 1997 Resolved
MAKE PERMANENT REPAIRS OR RENEW SHORE TIE BOX TO MAKE WATERTIGHT.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Construction/Loadline
Issued 21 October 1997 Resolved
MAKE PERMANENT REPAIRS OR RENEW MAIN DECK EXTERIOR DOORS TO MAKE WEATHER TIGHT.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Fire Fighting
Issued 21 October 1997 Resolved
INSTALL PROPER FIRE EXTINGUISHER BRACKETS THROUGHOUT VESSEL AS NEEDED.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Electrical
Issued 21 October 1997 Resolved
MAKE PERMANENT REPAIRS TO RESCUE BOAT LAUNCHING DEVICE ELECTRICAL PANELS ASNEEDED.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Documentation
Issued 21 October 1997 Resolved
PROVIDE CURRENT ELECTRICAL DRAWINGS TO COGNIZANT OCMI OR MSC FOR APPROVAL. IF EMERGENCY GENERATOR IS RENEWED, INCLUDE IN UPDATED PLANS.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Documentation
Issued 21 October 1997 Resolved
SUBMIT UPDATED FIRE AND EMERGENCY PLAN TO COGNIZANT OCMI FOR APPROVAL AND PROPERLY POST ONBOARD THE VESSEL.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Engineering
Issued 21 October 1997 Resolved
REPAIR OR RENEW EMERGENCY GENERATOR FUEL OIL TANK, INCLUDING INSTALLATION OF PROPER SIGHTGLASS.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Engineering
Issued 21 October 1997 Resolved
PROVIDE FOR RELIABLE OVERSPEED TRIP ON EMERGENCY GENERATOR PRIME MOVER OR RENEW WITH GENERATOR SET FOR WHICH PARTS ARE READILY AVAILABLE. MAKE PERMANENT REPAIRS TO FUEL OIL SUPPLY AND RETURN SYSTEM AS NEEDED WHEN GENERATOR IS REPAIRED OR RENEWED.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Accommodation/Occupational Safety
Issued 21 October 1997 Resolved
PROPERLY INSTALL VENTILATION FAN AND DUCTING TO COMPARTMENT ELEVEN.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Electrical
Issued 21 October 1997 Resolved
PROVIDE PERMANENT PROPER MEANS OF CONNECTING ELECTRICALLY TO WALKING SPUD BARGE OR REMOVE SYSTEM COMPLETELY.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Documentation
Issued 21 October 1997 Resolved
PROVIDE CURRENT COPIES OF THE FOLLOWING PUBLICATIONS: 46 CFR SUBCHAPTERS A,F, I, AND W, 33 CFR PARTS 125 THROUGH 199, AND NAVIGATION RULES OF THE ROAD.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Deck/Cargo
Issued 12 August 1997 Resolved
RENEW EXPANDED METAL SPUD WIRE GUARDS ON TOP DECK.
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997
Electrical
Issued 12 August 1997 Resolved
PROVE PROPER OPERATION OF SSG OVERSPEED TRIP.
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997
Electrical
Issued 17 July 1997 Resolved
Permanently fasten all electrical cables in accordance with IEEE section 20.5.
Condition: Unknown
Due 17 July 1997
Resolved 17 July 1997
Construction/Loadline
Issued 17 July 1997 Resolved
Chalk test all internal watertight doors.
Condition: Unknown
Due 17 July 1997
Resolved 17 July 1997
Electrical
Issued 17 July 1997 Resolved
Install guard around electrical connection (7000 volt) for main motor.
Condition: Unknown
Due 17 July 1997
Resolved 17 July 1997
Accommodation/Occupational Safety
Issued 17 July 1997 Resolved
Remove container (accommodations) on upper deck or provide all plans and stability calculations.
Condition: Unknown
Due 17 July 1997
Resolved 17 July 1997
Electrical
Issued 17 July 1997 Resolved
Replace two kick pipes, aft, house and two starboard side upper deck.
Condition: Unknown
Due 17 July 1997
Resolved 17 July 1997
Electrical
Issued 17 July 1997 Resolved
Prove proper operation of 24 volt emergency lighting system.
Condition: Unknown
Due 17 July 1997
Resolved 17 July 1997
Lifesaving
Issued 17 July 1997 Resolved
Reduce amount of Compound H on original bottom to a film.
Condition: Unknown
Due 17 July 1997
Resolved 17 July 1997
Electrical
Issued 17 July 1997 Resolved
Reinstall lighting fixture or properly dead end electrical cable, midship, starboard, upper deck.
Condition: Unknown
Due 17 July 1997
Resolved 17 July 1997
Electrical
Issued 17 July 1997 Resolved
Replace retaining device for electrical cable, overhead blower, upper deck.
Condition: Unknown
Due 17 July 1997
Resolved 17 July 1997
Lifesaving
Issued 17 July 1997 Resolved
Provide two adult life preservers. Vessel is restricted to 18 adults untilin compliance.
Condition: Unknown
Due 17 July 1997
Resolved 17 July 1997
Accommodation/Occupational Safety
Issued 17 July 1997 Resolved
Install as needed life lines, maindeck.
Condition: Unknown
Due 17 July 1997
Resolved 17 July 1997
Electrical
Issued 17 July 1997 Resolved
Remount light fixture, aft, port, upper deck.
Condition: Unknown
Due 17 July 1997
Resolved 17 July 1997
Electrical
Issued 17 July 1997 Resolved
Remount electrical outlet, aft, port, upper deck.
Condition: Unknown
Due 17 July 1997
Resolved 17 July 1997
Engineering
Issued 17 July 1997 Resolved
Install correct racor filter and bowl.
Condition: Unknown
Due 17 July 1997
Resolved 17 July 1997
Accommodation/Occupational Safety
Issued 17 July 1997 Resolved
Make port upper deck guard rail removable in way of life raft.
Condition: Unknown
Due 17 July 1997
Resolved 17 July 1997
Construction/Loadline
Issued 1 February 1994 Resolved
MAKE PERMANENT REPAIRS TO SALT WATER PIPE TO EDUCTOR IN FIRE PUMP SPACE FWD.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Fire Fighting
Issued 1 February 1994 Resolved
MAKE PERMANENT REPAIRS OR REMOVE 6 INCH RECIRC PIPE BETWEEN BOTH FIRE PUMPS
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Accommodation/Occupational Safety
Issued 1 February 1994 Resolved
MAKE PERMANENT REPAIRS OR RENEW WASTED MSD.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Accommodation/Occupational Safety
Issued 1 February 1994 Resolved
PROVIDE POWER SUPPLY TO THE GENERAL ALARM AS PER 46 CFR 113.25-7.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Navigation
Issued 1 February 1994 Resolved
MAKE OPERABLE THE AUDIBLE AND VISUAL ALARMS TO NAVIGATION LIGHT PANEL.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Electrical
Issued 1 February 1994 Resolved
REMOVE UNPROTECTED, PORTABLE LIGHT FROM LUBE LOCKER STBD MAIN DECK.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Lifesaving
Issued 1 February 1994 Resolved
PROPERLY MARK PFD STOWAGE AND AMOUNT OF PFDS INSIDE WITH 2 INCH LETTERS.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Electrical
Issued 1 February 1994 Resolved
REMOVE SO CABLE AND PERMANENTLY WIRE DENSITY EQUIPMENT, PORT SIDE FWD MACHINERY SPACE.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Electrical
Issued 12 November 1992 Resolved
REPLACE TACHOMETER ON DIESEL GENERATOR.
Condition: Unknown
Due 15 December 1992
Resolved 15 December 1992
Fire Fighting
Issued 12 November 1992 Resolved
PROVEDE [name withheld] OF CURRENT CO2 BOTTLE HYDRO TEST DATES.
Condition: Unknown
Due 15 December 1992
Resolved 15 December 1992
Documentation
Issued 12 November 1992 Resolved
RENEW LOADLINE CERTIFICATE PRIOR TO COASTWISE VOYAGE.
Condition: Unknown
Due 15 December 1992
Resolved 15 December 1992
Documentation
Issued 10 February 1992 Resolved
33 CFR 151.59(b) THE MASTER OR PERSON IN CHARGE OF THE VESSEL DID NOT ENSURE THAT ONE MARPOL ANNEX V PLACARD WAS DISPLAYED ON THE VESSEL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 February 1992
Resolved 11 February 1992
Accommodation/Occupational Safety
Issued 10 February 1992 Resolved
33 CFR 151.66 NO PERSON ON BOARD VESSEL MAY DISCHARGE GARBAGE INTO THE NAVIGABLE WATERS OF THE UNITED STATES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 February 1992
Resolved 11 February 1992
Accommodation/Occupational Safety
Issued 10 February 1992 Resolved
33 CFR 151.63(a) THE MASTER OR PERSON IN CHARGE OF THE VESSEL DID NOT ENSURE THAT ALL GARBAGE WAS DISCHARGED ASHORE IN THAT A 5 GALLON DRUM OF CLEANING AGENT FROM THE VESSEL WAS FOUND IN THE WATER._x001C_ _x001C_
Condition: Unknown
Due 11 February 1992
Resolved 11 February 1992
Lifesaving
Issued 10 May 1990 Resolved
SERVICE THE 20 MAN LIFERAFT AND THE HYDRAULIC RELEASE.
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Fire Fighting
Issued 10 May 1990 Resolved
ARRANGE AND STATION ALL FIRE EXTINGUISHERS AS REQUIRED BY THE COI.
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Fire Fighting
Issued 10 May 1990 Resolved
RENEW HOLED DISCHARGE LINE ON THE PORT FIRE PUMP, SUBJECT PIPE MUST BE REPLACED COMPLETELY BETWEEN BOTH FLANGES.
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Lifesaving
Issued 10 May 1990 Resolved
STENCIL STARBOARD SIDE BRIDGE WING RING BUOY.
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Unknown
Issued 18 April 1989 Resolved
PROVIDE OIL TRANSFER PROCEDURES AND PERSONS-IN-CHARGE LIST.
Condition: Unknown
Due 18 April 1989
Resolved 18 April 1989
Engineering
Issued 4 April 1989 Resolved
CROP AND RENEW FUEL RETURN PIPE TO DAY TANK IN WAY OF PIN HOLE APPROXIMATE-LY ONE FOOT UP FROM FUEL CONTAINMENT.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Electrical
Issued 4 April 1989 Resolved
PROVIDE SAFETY GUARD FOR BELT DRIVE ASSEMBLY TO POSITIVE VENTILATION FAN.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Fire Fighting
Issued 4 April 1989 Resolved
REPAIR HOSE REEL CONNECTION TO FIXED CO2 SYSTEM AT HOSE ASSEMBLY HANDLE.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Lifesaving
Issued 4 April 1989 Resolved
INSTALL HYDRO RELEASE DEVICE TO INFLATABLE LIFE RAFT.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Lifesaving
Issued 25 February 1988 Resolved
REPAIR FLOAT LIGHT TO LIFE RING STBD AFT CORNER OF MAIN DECK.
Condition: Unknown
Due 25 February 1988
Resolved 25 February 1988
Navigation
Issued 25 February 1988 Resolved
PROPERLY POSITION PORT AND STBD RUNNING LIGHTS SCREENS.
Condition: Unknown
Due 25 February 1988
Resolved 25 February 1988
Lifesaving
Issued 25 February 1988 Resolved
PROVIDE TWO (02) ADDITIOAL RING BUOYS AND ONE (01) FLOAT LIGHT.
Condition: Unknown
Due 25 February 1988
Resolved 25 February 1988

Casualty record · 2

11 October 2004Routine · role: Involved in a Marine Casualty · activity 2309115
24 October 2013Routine · role: Involved in a Marine Casualty · activity 4741037
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.